873 resultados para Beam complexity


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Three experiments investigated the effect of complexity on children's understanding of a beam balance. In nonconflict problems, weights or distances varied, while the other was held constant. In conflict items, both weight and distance varied, and items were of three kinds: weight dominant, distance dominant, or balance (in which neither was dominant). In Experiment 1, 2-year-old children succeeded on nonconflict-weight and nonconflict-distance problems. This result was replicated in Experiment 2, but performance on conflict items did not exceed chance. In Experiment 3, 3- and 4-year-olds succeeded on all except conflict balance problems, while 5- and 6-year-olds succeeded on all problem types. The results were interpreted in terms of relational complexity theory. Children aged 2 to 4 years succeeded on problems that entailed binary relations, but 5- and 6-year-olds also succeeded on problems that entailed ternary relations. Ternary relations tasks from other domains-transitivity and class inclusion-accounted for 93% of the age-related variance in balance scale scores. (C) 2002 Elsevier Science (USA).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Real structures can be thought as an assembly of components, as for instances plates, shells and beams. This later type of component is very commonly found in structures like frames which can involve a significant degree of complexity or as a reinforcement element of plates or shells. To obtain the desired mechanical behavior of these components or to improve their operating conditions when rehabilitating structures, one of the eventual parameters to consider for that purpose, when possible, is the location of the supports. In the present work, a beam-type structure is considered, and for a set of cases concerning different number and types of supports, as well as different load cases, the authors optimize the location of the supports in order to obtain minimum values of the maximum transverse deflection. The optimization processes are carried out using genetic algorithms. The results obtained, clearly show a good performance of the approach proposed. © 2014 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The problem of assigning cells to switches in a cellular mobile network is an NP-hard optimization problem. So, real size mobile networks could not be solved by using exact methods. The alternative is the use of the heuristic methods, because they allow us to find a good quality solution in a quite satisfactory computational time. This paper proposes a Beam Search method to solve the problem of assignment cell in cellular mobile networks. Some modifications in this algorithm are also presented, which allows its parallel application. Computational results obtained from several tests confirm the effectiveness of this approach to provide good solutions for medium- and large-sized cellular mobile network.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Intensity modulated radiation therapy (IMRT) is a technique that delivers a highly conformal dose distribution to a target volume while attempting to maximally spare the surrounding normal tissues. IMRT is a common treatment modality used for treating head and neck (H&N) cancers, and the presence of many critical structures in this region requires accurate treatment delivery. The Radiological Physics Center (RPC) acts as both a remote and on-site quality assurance agency that credentials institutions participating in clinical trials. To date, about 30% of all IMRT participants have failed the RPC’s remote audit using the IMRT H&N phantom. The purpose of this project is to evaluate possible causes of H&N IMRT delivery errors observed by the RPC, specifically IMRT treatment plan complexity and the use of improper dosimetry data from machines that were thought to be matched but in reality were not. Eight H&N IMRT plans with a range of complexity defined by total MU (1460-3466), number of segments (54-225), and modulation complexity scores (MCS) (0.181-0.609) were created in Pinnacle v.8m. These plans were delivered to the RPC’s H&N phantom on a single Varian Clinac. One of the IMRT plans (1851 MU, 88 segments, and MCS=0.469) was equivalent to the median H&N plan from 130 previous RPC H&N phantom irradiations. This average IMRT plan was also delivered on four matched Varian Clinac machines and the dose distribution calculated using a different 6MV beam model. Radiochromic film and TLD within the phantom were used to analyze the dose profiles and absolute doses, respectively. The measured and calculated were compared to evaluate the dosimetric accuracy. All deliveries met the RPC acceptance criteria of ±7% absolute dose difference and 4 mm distance-to-agreement (DTA). Additionally, gamma index analysis was performed for all deliveries using a ±7%/4mm and ±5%/3mm criteria. Increasing the treatment plan complexity by varying the MU, number of segments, or varying the MCS resulted in no clear trend toward an increase in dosimetric error determined by the absolute dose difference, DTA, or gamma index. Varying the delivery machines as well as the beam model (use of a Clinac 6EX 6MV beam model vs. Clinac 21EX 6MV model), also did not show any clear trend towards an increased dosimetric error using the same criteria indicated above.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Radiation therapy has been used as an effective treatment for malignancies in pediatric patients. However, in many cases, the side effects of radiation diminish these patients’ quality of life. In order to develop strategies to minimize radiogenic complications, one must first quantitatively estimate pediatric patients’ relative risk for radiogenic late effects, which has not become feasible till recently because of the calculational complexity. The goals of this work were to calculate the dose delivered to tissues and organs in pediatric patients during contemporary photon and proton radiotherapies; to estimate the corresponding risk of radiogenic second cancer and cardiac toxicity based on the calculated doses and on dose-risk models from the literature; to test for the statistical significance of the difference between predicted risks after photon versus proton radiotherapies; and to provide a prototype of an evidence-based approach to selecting treatment modalities for pediatric patients, taking second cancer and cardiac toxicity into account. The results showed that proton therapy confers a lower predicted risk of radiogenic second cancer, and lower risks of radiogenic cardiac toxicities, compared to photon therapy. An uncertainty analysis revealed that the qualitative findings of this study are insensitive to changes in a wide variety of host and treatment related factors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

La presente tesis doctoral con título "Contribution to Active Multi-Beam Reconfigurable Antennas for L and S Bands" ha sido desarrollada por el investigador ingeniero de telecomunicación estudiante de doctorado Javier García-Gasco Trujillo en el Grupo de Radiación del Departamento de Señales, Sistemas y Radiocomunicaciones de la ETSI de Telecomunicación de la Universidad Politécnica de Madrid bajo la dirección de los doctores Manuel Sierra Pérez y José Manuel Fernández González. Durante décadas, el desarrollo de antenas de apuntamiento electrónico ha estado limitado al área militar. Su alto coste y su gran complejidad eran los mayores obstáculos que frenaban la introducción de esta tecnología en aplicaciones comerciales de gran escala. La reciente aparición de componentes de estado sólido prácticos, fiables, y de bajo coste ha roto la barrera del coste y ha reducido la complejidad, haciendo que las antenas reconfigurables de apuntamiento electrónico sean una opción viable en un futuro cercano. De esta manera, las antenas phased array podrían llegar a ser la joya de la corona que permitan alcanzar los futuros retos presentes en los sistemas de comunicaciones tanto civiles como militares. Así pues, ahora es el momento de investigar en el desarrollo de antenas de apuntamiento electrónico de bajo coste, donde los nuevos componentes de estado sólido comerciales forman el núcleo duro de la arquitectura. De esta forma, el estudio e implementación de estos arrays de antenas activas de apuntamiento electrónico capaces de controlar la fase y amplitud de las distintas señales implicadas es uno de los grandes retos de nuestro tiempo. Esta tesis se enfrenta a este desafío, proponiendo novedosas redes de apuntamiento electrónico e innovadores módulos de transmisión/recepción (T/R) utilizando componentes de estado sólido de bajo coste, que podrán integrar asequibles antenas activas reconfigurables multihaz en bandas L y S. En la primera parte de la tesis se realiza una descripción del estado del arte de las antenas phased array, incluyendo su base teórica y sus ventajas competitivas. Debido a que las contribuciones obtenidas en la presente tesis han sido realizadas dentro de distintos proyectos de investigación, donde se han manejada antenas de simple/doble polarización circular y simple/doble banda de trabajo, se describen detenidamente los dos proyectos más relevantes de la investigación: el radar de basura espacial de la Agencia Espacial Europea (ESA), Space Situational Awareness (SSA); y la estación base de seguimiento y control de satélites de órbita baja, GEOdesic Dome Array (GEODA). Sin lugar a dudas, los dispositivos desfasadores son uno de los componentes clave en el diseño de antenas phased arrays. Recientemente se ha observado una gran variación en el precio final de estos dispositivos, llegando en ocasiones a límites inasequibles. Así pues, se han propuesto distintas técnicas de conformación de haz alternativas a la utilización de componentes desfasadores comerciales: el desfasador de líneas conmutadas, la red de haz conmutado, y una novedosa red desfasadora divisora/combinadora de potencia. Para mostrar un uso práctico de las mismas, se ha propuesto el uso de las tres alternativas para el caso práctico del subarray de cinco elementos de la celda GEODA-SARAS. Tras dicho estudio se obtiene que la novedosa red desfasadora divisora/combinadora de potencia propuesta es la que mejor relación comportamiento/coste presenta. Para verificar su correcto funcionamiento se construye y mide los dos bloques principales de los que está compuesta la red total, comprobando que en efecto la red responde según lo esperado. La estructura más simple que permite realizar un barrido plano es el array triangular de tres elementos. Se ha realizado el diseño de una nueva red multihaz que es capaz de proporcionar tres haces ortogonales en un ángulo de elevación _0 y un haz adicional en la dirección broadside utilizando el mencionado array triangular de tres elementos como antena. En primer lugar se realizar una breve introducción al estado del arte de las redes clásicas multihaz. Así mismo se comentan innovadores diseños de redes multihaz sin pérdidas. El estudio da paso a las redes disipativas, de tal forma que se analiza su base matemática y se muestran distintas aplicaciones en arrays triangulares de tres elementos. Finalmente, la novedosa red básica propuesta se presenta, mostrando simulaciones y medidas de la misma para el caso prácticoo de GEODA. También se ha diseñado, construido y medido una red compuesta por dos redes básicas complementarias capaz de proporcionar seis haces cuasi-ortogonales en una dirección _0 con dos haces superpuestos en broadside. La red propuesta queda totalmente validada con la fabricación y medida de estos con prototipos. Las cadenas de RF de los módulos T/R de la nueva antena GEODA-SARAS no son algo trivial. Con el fin de mostrar el desarrollo de una cadena compleja con una gran densidad de componentes de estado sólido, se presenta una descripción detallada de los distintos componentes que integran las cadenas de RF tanto en transmisión como en recepción de la nueva antena GEODA-SARAS. Tras presentar las especificaciones de la antena GEODA-SARA y su diagrama de bloques esquemático se describen los dos bloques principales de las cadenas de RF: la celda de cinco elementos, y el módulo de conversión de panel. De la misma manera también se presentará el módulo de calibración integrado dentro de los dos bloques principales. Para comprobar que el funcionamiento esperado de la placa es el adecuado, se realizará un análisis que tratará entre otros datos: la potencia máxima en la entrada del transmisor (comprobando la saturación de la cadena), señal de recepción mínima y máxima (verificando el rango de sensibilidad requerido), y el factor G/T (cumpliendo la especificación necesaria). Así mismo se mostrará un breve estudio del efecto de la cuantificación de la fase en el conformado de haz de RF. Los estudios muestran que la composición de las cadenas de RF permite el cumplimiento de las especificaciones necesarias. Finalmente la tesis muestra las conclusiones globales del trabajo realizado y las líneas futuras a seguir para continuar con esta línea de investigación. ABSTRACT This PhD thesis named "Contribution to Active Multi-Beam Reconfigurable Antennas for L and S Bands", has been written by the Electrical Engineer MSc. researcher Javier García-Gasco Trujillo in the Grupo de Radiación of the Departamento de Señales, Sistemas y Radiocomunicaciones from the ETSI de Telecomunicación of the Universidad Politécnica de Madrid. For decades, the implementation of electronically steerable phased array antennas was confined to the military area. Their high cost and complexity were the major obstacles to introduce this technology in large scale commercial applications. The recent emergence of new practical, low-cost, and highly reliable solid state devices; breaks the barrier of cost and reduces the complexity, making active phased arrays a viable future option. Thus, phased array antennas could be the crown jewel that allow to meet the future challenges in military and civilian communication systems. Now is time to deploy low-cost phased array antennas, where newly commercial components form the core of the architecture. Therefore, the study and implementation of these novel low-cost and highly efficient solid state phased array blocks capable of controlling signal phase/amplitude accurately is one of the great challenges of our time. This thesis faces this challenge, proposing innovative electronic beam steering networks and transmitter/ receiver (T/R) modules using affordable solid state components, which could integrate fair reconfigurable phased array antennas working in L and S bands. In the first part of the thesis, a description of the state of art of phased array antennas, including their fundamentals and their competitive advantages, is presented. Since thesis contributions have been carried out for different research projects, where antennas with single/double circular polarization and single/double working frequency bands have been examined, frameworks of the two more important projects are detailed: the Space Situational Awareness (SSA) programme from the European Space Agency (ESA), and the GEOdesic Dome Array (GEODA) project from ISDEFE-INSA and the ESA. Undoubtedly, phase shifter devices are one of the key components of phased array antennas. Recent years have witnessed wide fluctuations in commercial phase shifter prices, which sometimes led to unaffordable limit. Several RF steering technique alternatives to the commercial phase shifters are proposed, summarized, and compared: the switched line phase shifter, the switched-beam network, and the novel phase shifter power splitter/combiner network. In order to show a practical use of the three different techniques, the five element GEODA-SARAS subarray is proposed as a real case of study. Finally, a practical study of a newly phase shifter power splitter/combiner network for a subarray of five radiating elements with triangular distribution is shown. Measurements of the two different phase shifter power splitter/combiner prototypes integrating the whole network are also depicted, demonstrating their proper performance. A triangular cell of three radiating elements is the simplest way to obtain a planar scanner. A new multibeam network configuration that provides three orthogonal beams in a desired _0 elevation angle and an extra one in the broadside steering direction for a triangular array of three radiating elements is introduced. Firstly, a short introduction to the state of art of classical multi-beam networks is presented. Lossless network analysis, including original lossless network designs, are also commented. General dissipative network theory as well as applications for array antennas of three radiating elements are depicted. The proposed final basic multi-beam network are simulated, built and measured to the GEODA cell practical case. A combined network that provides six orthogonal beams in a desired _0 elevation angle and a double seventh one in the broadside direction by using two complementary proposed basic networks will be shown. Measurements of the whole system will be also depicted, verifying the expected behavior. GEODA-SARAS T/R module RF chains are not a trivial design. A thorough description of all the components compounding GEODA-SARAS T/R module RF chains is presented. After presenting the general specifications of the GEODA-SARAS antenna and its block diagrams; two main blocks of the RF chains, the five element cell and the panel conversion module, are depicted and analyzed. Calibration module integrated within the two main blocks are also depicted. Signal flow throw the system analyzing critical situations such as maximum transmitted power (testing the chain unsaturation), minimum and maximum receiving signal (verifying sensitivity range), maximum receiver interference signals (assuring a proper reception), and G/T factor (fulfilling the technical specification) are evaluated. Phase quantization error effects are also listed. Finally, the manuscript contains the conclusions drawn of the present research and the future work.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We study a multiuser multicarrier downlink communication system in which the base station (BS) employs a large number of antennas. By assuming frequency-division duplex operation, we provide a beam domain channel model as the number of BS antennas grows asymptotically large. With this model, we first derive a closed-form upper bound on the achievable ergodic sum-rate before developing necessary conditions to asymptotically maximize the upper bound, with only statistical channel state information at the BS. Inspired by these conditions, we propose a beam division multiple access (BDMA) transmission scheme, where the BS communicates with users via different beams. For BDMA transmission, we design user scheduling to select users within non-overlapping beams, work out an optimal pilot design under a minimum mean square error criterion, and provide optimal pilot sequences by utilizing the Zadoff-Chu sequences. The proposed BDMA scheme reduces significantly the pilot overhead, as well as, the processing complexity at transceivers. Simulations demonstrate the high spectral efficiency of BDMA transmission and the advantages in the bit error rate performance of the proposed pilot sequences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapidity-odd directed flow (v1) measurements for charged pions, protons, and antiprotons near midrapidity (y=0) are reported in sNN=7.7, 11.5, 19.6, 27, 39, 62.4, and 200 GeV Au+Au collisions as recorded by the STAR detector at the Relativistic Heavy Ion Collider. At intermediate impact parameters, the proton and net-proton slope parameter dv1/dy|y=0 shows a minimum between 11.5 and 19.6 GeV. In addition, the net-proton dv1/dy|y=0 changes sign twice between 7.7 and 39 GeV. The proton and net-proton results qualitatively resemble predictions of a hydrodynamic model with a first-order phase transition from hadronic matter to deconfined matter, and differ from hadronic transport calculations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Local parity-odd domains are theorized to form inside a quark-gluon plasma which has been produced in high-energy heavy-ion collisions. The local parity-odd domains manifest themselves as charge separation along the magnetic field axis via the chiral magnetic effect. The experimental observation of charge separation has previously been reported for heavy-ion collisions at the top RHIC energies. In this Letter, we present the results of the beam-energy dependence of the charge correlations in Au+Au collisions at midrapidity for center-of-mass energies of 7.7, 11.5, 19.6, 27, 39, and 62.4 GeV from the STAR experiment. After background subtraction, the signal gradually reduces with decreased beam energy and tends to vanish by 7.7 GeV. This implies the dominance of hadronic interactions over partonic ones at lower collision energies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the first measurements of the moments--mean (M), variance (σ(2)), skewness (S), and kurtosis (κ)--of the net-charge multiplicity distributions at midrapidity in Au+Au collisions at seven energies, ranging from sqrt[sNN]=7.7 to 200 GeV, as a part of the Beam Energy Scan program at RHIC. The moments are related to the thermodynamic susceptibilities of net charge, and are sensitive to the location of the QCD critical point. We compare the products of the moments, σ(2)/M, Sσ, and κσ(2), with the expectations from Poisson and negative binomial distributions (NBDs). The Sσ values deviate from the Poisson baseline and are close to the NBD baseline, while the κσ(2) values tend to lie between the two. Within the present uncertainties, our data do not show nonmonotonic behavior as a function of collision energy. These measurements provide a valuable tool to extract the freeze-out parameters in heavy-ion collisions by comparing with theoretical models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article aimed at comparing the accuracy of linear measurement tools of different commercial software packages. Eight fully edentulous dry mandibles were selected for this study. Incisor, canine, premolar, first molar and second molar regions were selected. Cone beam computed tomography (CBCT) images were obtained with i-CAT Next Generation. Linear bone measurements were performed by one observer on the cross-sectional images using three different software packages: XoranCat®, OnDemand3D® and KDIS3D®, all able to assess DICOM images. In addition, 25% of the sample was reevaluated for the purpose of reproducibility. The mandibles were sectioned to obtain the gold standard for each region. Intraclass coefficients (ICC) were calculated to examine the agreement between the two periods of evaluation; the one-way analysis of variance performed with the post-hoc Dunnett test was used to compare each of the software-derived measurements with the gold standard. The ICC values were excellent for all software packages. The least difference between the software-derived measurements and the gold standard was obtained with the OnDemand3D and KDIS3D (-0.11 and -0.14 mm, respectively), and the greatest, with the XoranCAT (+0.25 mm). However, there was no statistical significant difference between the measurements obtained with the different software packages and the gold standard (p> 0.05). In conclusion, linear bone measurements were not influenced by the software package used to reconstruct the image from CBCT DICOM data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUÇÃO: quanto menor a dimensão do voxel, maior a nitidez da imagem de tomografia computadorizada Cone-Beam (TCCB), porém, maior a dose de radiação emitida. OBJETIVOS: avaliar e comparar a reprodutibilidade da mensuração da espessura das tábuas ósseas vestibular e lingual em imagens de TCCB, utilizando diferentes protocolos de aquisição de imagem com variação da dimensão do voxel. MÉTODOS: exames de TCCB foram tomados de 12 mandíbulas humanas secas, com dimensão do voxel de 0,2; 0,3 e 0,4mm, no aparelho i-CAT Cone-Beam 3-D Dental Imaging System. No software i-CAT Viewer, foi mensurada a espessura das tábuas ósseas vestibular e lingual, em um corte axial passando 12mm acima do forame mentoniano do lado direito. A reprodutibilidade intraexaminador foi avaliada por meio da aplicação do teste t pareado. Para a comparação interexaminadores, foi utilizado o teste t independente. Os resultados foram considerados com o nível de significância de 5%. RESULTADOS: observou-se uma excelente reprodutibilidade interexaminadores para os três protocolos avaliados. A reprodutibilidade intraexaminadores foi muito boa, com exceção de algumas regiões dos dentes anteriores, que mostraram diferenças estatisticamente significativas, independentemente da dimensão do voxel. CONCLUSÃO: a mensuração da espessura das tábuas ósseas vestibular e lingual em imagens de TCCB mostrou boa precisão para exames obtidos com voxel de 0,2; 0,3 ou 0,4mm. A reprodutibilidade das mensurações na região anterior da mandíbula foi mais crítica do que na região posterior.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUÇÃO: a espessura das tábuas ósseas que recobrem os dentes por vestibular e lingual constitui um dos fatores limitantes da movimentação dentária. O avanço tecnológico em Imaginologia permitiu avaliar detalhadamente essas regiões anatômicas por meio da utilização da tomografia computadorizada de feixe cônico (TCFC). OBJETIVO: descrever e padronizar, pormenorizadamente, um método para mensuração das tábuas ósseas vestibular e lingual dos maxilares nas imagens de tomografia computadorizada de feixe cônico. METODOLOGIA: a padronização digital da posição da imagem da face deve constituir o primeiro passo antes da seleção dos cortes de TCFC. Dois cortes axiais de cada maxilar foram empregados para a mensuração da espessura do osso alveolar vestibular e lingual. Utilizou-se como referência a junção cemento-esmalte dos primeiros molares permanentes, tanto na arcada superior quanto na inferior. RESULTADOS: cortes axiais paralelos ao plano palatino foram indicados para avaliação quantitativa do osso alveolar na maxila. Na arcada inferior, os cortes axiais devem ser paralelos ao plano oclusal funcional. CONCLUSÃO: o método descrito apresenta reprodutibilidade para utilização em pesquisas, assim como para a avaliação clínica das repercussões periodontais da movimentação dentária, ao permitir a comparação de imagens pré e pós-tratamento.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The determination of the success of endodontic treatment has been often discussed based on outcome obtained by periapical radiography. The aim of this study was to verify the influence of intracanal post on apical periodontitis detected by cone-beam computed tomography (CBCT). A consecutive sample of 1020 images (periapical radiographs and CBCT scans) taken from 619 patients (245 men; mean age, 50.1 years) between February 2008 and September 2009 were used in this study. Presence and intracanal post length (short, medium and long) were associated with apical periodontitis (AP). Chi-square test was used for statistical analyses. Significance level was set at p<0.01. The kappa value was used to assess examiner variability. From a total of 591 intracanal posts, AP was observed in 15.06%, 18.78% and 7.95% using periapical radiographs, into the different lengths, short, medium and long, respectively (p=0.466). Considering the same posts length it was verified AP in 24.20%, 26.40% and 11.84% observed by CBCT scans, respectively (p=0.154). From a total of 1,020 teeth used in this study, AP was detected in 397 (38.92%) by periapical radiography and in 614 (60.19%) by CBCT scans (p<0.001). The distribution of intracanal posts in different dental groups showed higher prevalence in maxillary anterior teeth (54.79%). Intracanal posts lengths did not influenced AP. AP was detected more frequently when CBCT method was used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article describes and discusses a method to determine root curvature radius by using cone-beam computed tomography (CBCT). The severity of root canal curvature is essential to select instrument and instrumentation technique. The diagnosis and planning of root canal treatment have traditionally been made based on periapical radiography. However, the higher accuracy of CBCT images to identify anatomic and pathologic alterations compared to panoramic and periapical radiographs has been shown to reduce the incidence of false-negative results. In high-resolution images, the measurement of root curvature radius can be obtained by circumcenter. Based on 3 mathematical points determined with the working tools of Planimp® software, it is possible to calculate root curvature radius in both apical and coronal directions. The CBCT-aided method for determination of root curvature radius presented in this article is easy to perform, reproducible and allows a more reliable and predictable endodontic planning, which reflects directly on a more efficacious preparation of curved root canals.