1000 resultados para Baroreceptor sensitivity


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We conducted a study to investigate whether patients with somatization disorders (ICD-10, F45.0) show abnormal values in autonomic testing.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Nhlh1 is a basic helix-loop-helix transcription factor whose expression is restricted to the nervous system and which may play a role in neuronal differentiation. To directly study Nhlh1 function, we generated null mice. Homozygous mutant mice were predisposed to premature, adult-onset, unexpected death. Electrocardiograms revealed decreased total heart rate variability, stress-induced arrhythmia, and impaired baroreceptor sensitivity. This predisposition to arrhythmia is a likely cause of the observed death in the mutant mice. Heterozygosity for the closely related transcription factor Nhlh2 increased the severity of the Nhlh1-null phenotype. No signs of primary cardiac structural or conduction abnormalities could be detected upon necropsy of the null mice. The pattern of altered heart rhythm observed in basal and experimental conditions (stress and pharmacologically induced) suggests that a deficient parasympathetic tone may contribute to the arrhythmia in the Nhlh1-null mouse. The expression of Nhlh1 in the developing brain stem and in the vagal nuclei in the wild-type mouse further supports this hypothesis. The Nhlh1 mutant mouse may thus provide a model to investigate the contribution of the autonomic nervous system to arrhythmogenesis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The ability of the cardiovascular system to quickly and efficiently adapt to an orthostatic stress is vital for the human body to function on earth. The way in which the various aspects of the cardiovascular system work together to counteract an orthostatic stress has been previously quantified in the adult population. However, there are still many unknowns surrounding the topic of how the cardiovascular system functions to cope with this same stress in children. The purpose of this study was to describe the cardiovascular hemodynamic adaptations to various levels of orthostatic stress induced using a lower body negative pressure (LBNP) chamber in pre-pubertal boys. A secondary purpose was to determine indices of baroreceptor sensitivity (BRS) at both rest and during low levels of LBNP in this same pediatric sample. Finally, this study aimed to compare the relative responses to LBNP between the children and adults. To complete the study 20 healthy pre-pubertal boys and adult males (9.3 ± 1.1 and 23 ± 1.8 years of age respectively) were recruited and randomly exposed to three levels of LBNP (15, 20 and 25 mmHg). At rest and during the application of the LBNP heart rate (HR), manual and bcat-by-beat systolic (SBP), diastolic (DBP) and mean arterial blood pressure (MAP) were monitored continuously. Aortic diameter was measured at rest and peak aortic blood velocity (PV) was recorded continuously for at least I minute during each baseline and LBNP condition. From the raw data HR, stroke volume (SV), cardiac output (Q), total peripheral resistance (TPR), low frequency baroreceptor sensitivity (LF BRS), high frequency baroreceptor sensitivity (HF BRS) and LFIIIF ratio were calculated. At rest, llR wa'i higher and SBP, SV, Q and LF/HF ratio were lower in the children compared to the adult males (pgJ.05). In response to the increasing LEN!> IIR and TPR increased, and LF BRS. SV and Q decreased in the adult group (pSf).05). while the same levels of LBNP caused an increase in TPR and a decrease in SBP, SV and Q in the children (pSf).05). Although not significant, the LF/HF ratio in the adult group showed an increasing trend in response to increased negative pressure (p=O.088). As for resting BRS, there were no significant differences in LF or HF BRS between the children and the adults despite a tendency for both measures to be 18% lower in the children. Also the LF/HF ratio was almost significantly greater in the adults compared to the children (p=O.057). In addition, a comparison between the relative adult and child responses to LBNP yielded no significant group by level interactions. This result should be taken with caution though, as the low sample size and high measurement variability generated very low statistical power for this analysis. In conclusion, the results of this study suggest that the hemodynamic adaptations to an orthostatic stress were less pronounced in the prepubertal males, most likely due to an underdeveloped autonomic system. These results need to be strengthened by further research before any implications can be derived for health care purposes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

L’analyse spectrale de la fréquence cardiaque, de la pression artérielle systolique, de la pression artérielle diastolique ainsi que de la respiration par la transformée de Fourier rapide, est considérée comme une technique non invasive pour la détermination de l’activité du système nerveux autonome (SNA). Dans une population de sujets normaux volontaires, nous avons obtenu à l’état basal, des oscillations de basses fréquences (0,05-0,15Hz) reliées au système nerveux sympathique autonome et des oscillations de hautes fréquences (0,2Hz) représentant sur les intervalles entre chaque ondes R de l’électrocardiogramme (RR), l’arythmie sinusale respiratoire correspondant à une activité vagale. Nous avons comparé les tests de stimulation du système nerveux sympathique autonome déclenché par le passage de la position de repos (en décubitus dorsal), à la position orthostatique volontaire et le passage de la position de repos à la position orthostatique avec la table basculante à 60o. Nous avons également comparé un groupe normotendu à un groupe hypertendu qui a été soumis au passage du repos à l’orthostation volontaire et pour lesquels nous avons évalué la sensibilité du baroréflexe et la réponse sympathique par la mesure des catécholamines circulantes. Dans un groupe de sujets ayant une hypertension artérielle essentielle, nous avons évalué l’effet de la thérapie hypotensive, par le Trandolapril qui est un Inhibiteur de l’enzyme de conversion (IEC) de l`angiotensine. Dans ce groupe hypertendu, nous avons procédé, en plus de la stimulation sympathique par l’orthostation volontaire, à un exercice isométrique de trois minutes à 30 % de la force maximale. Nous avons également complété notre évaluation par la mesure de la densité de récepteurs ß2 adrénergiques sur lymphocytes et par la mesure des indices de contractilité à l’aide de l’échocardiographie en M mode. Les résultats ont montré, dans les groupes normaux volontaires, dans les deux types de stimulation du système nerveux sympathique par la position orthostatique, une augmentation significative des catécholamines plasmatiques avec une augmentation de la fréquence cardiaque et des basses fréquences de RR, confirmant ainsi que l’on est en état de stimulation sympathique. On observe en même temps une diminution significative des hautes fréquences de RR, suggérant un retrait vagal lors de cette stimulation. On a observé au test de la table basculante six cas d’hypotension orthostatique. On a comparé la position orthostatique volontaire entre le groupe de sujets normaux et le groupe de sujets hypertendus. L’analyse spectrale croisée de RR et de la pression artérielle systolique a permis d’évaluer dans l’hypertension artérielle (HTA), essentielle une sensibilité du baroréflexe atténuée, accompagnée d’une réactivité vagale réduite en présence d’une activité et d’une réactivité sympathique augmentées suggérant une altération sympathovagale dans l’HTA. Dans le groupe de sujets hypertendus traités (Trandolapril 2mg/jour), nous avons identifié un groupe de répondeurs au traitement par le Trandolapril et un groupe de non répondeurs à ce type de thérapie anti-hypertensive. Le groupe répondeur avait un profil hyper-adrénergique avec une hyper-réactivité sympathique, une fréquence cardiaque et des pressions artérielles diastolique et systolique plus élevées au repos. Dans le groupe total traité au Trandolapril, la densité des récepteurs ß2 adrénergiques a doublé, après thérapie, alors que la réactivité des basses fréquences obtenues à l’analyse spectrale a augmenté. Nous avons montré dans notre étude qu’un IECA a pu inhiber le mécanisme facilitateur de l’angII sur les terminaisons nerveuses sympathiques et a permis ainsi de réduire l’hyperactivité sympathique et le mécanisme de « down regulation » des récepteurs ß2 adrénergiques rendant ainsi l’expression de l’influence du SNA post synaptique plus efficace. Dans l’ensemble de nos protocoles cliniques, par l’utilisation de l’analyse spectrale des signaux RR, de la pression artérielle systolique,de la pression artérielle diastolique et de la respiration, nous avons montré que cette technique non invasive permet de décrire et de mieux comprendre les mécanismes physiologiques, physiopathologiques et pharmacologiques reliés au système nerveux autonome et à l’hypertension artérielle essentielle.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

AIM: We conducted a study to investigate whether patients with somatization disorder show abnormal values in autonomic testing, especially in the central baroreceptor sensitivity. PATIENTS AND METHODS: Seventy-one patients were included. All had a diagnosis of somatization disorder (ICD-10, F45.0). Psychometric testing was performed by means of validated questionnaires (STAI, STAXI, FPI, GBB, ADS, SOMS, SCL-90-R). Autonomic regulation was analyzed by international standards using frequency spectral calculation by fast Fourier transformation. Thereby 3 different groups were detected: 12 patients with a baroreceptor sensitivity (BRS) of less than 3.0 ms/mm Hg, 20 patients with normal BRS (> 9.0 ms/mm Hg), and an in-between group (n = 39) with intermediate BRS. Controlling for age, a covariance analysis was calculated. RESULTS: The two extreme groups showed no difference in psychometric testing. However, significant differences were discernible in spectral values of mid-frequency-band (p < 0.05) in a covariance analysis with age as covariate. Equally the 24 h blood pressure determination showed significantly higher values for the group with BRS < 3.0 ms/mm Hg (p < 0.05 to 0.001). CONCLUSIONS: In a high percentage (17 %) of patients diagnosed to have somatization disorder autonomic dysregulation becomes apparent and is accompanied by increased blood pressure. Therefore it doesn't seem accurate to overlook concomitant organic lesions in somatization disorders despite patients lacking overtly clinical signs but suffering from various unspecific symptoms.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: The objective of this study was to analyze the autonomic functions of patients with erythrophobia. METHODS: Forty patients with a diagnosis of erythrophobia (female/male ratio 18/22) without any other organic lesions and 20 healthy volunteers (female/male ratio 10/10) were assessed. Clinical evaluation was performed using a modified version of semistructured interviews. Autonomic testing was performed by means of spectral analysis of heart rate and continuous blood pressure by sparse discrete Fourier transformation at rest and under mental stress. RESULTS: There were no significant difference between the two samples in age, sex distribution, BMI, resting systolic, or diastolic blood pressure, nor was there a difference in autonomic baseline functioning between the 40 patients with erythrophobia and the control subjects. On the other hand, patients with erythrophobia consistently showed higher pulse rates (88 +/- 20 vs. 78 +/- 9 bpm, p <.05), higher total heart rate power values (8.40 +/- 0.63 vs. 8.07 +/- 1.02 p <.05), higher midfrequency spectral values (7.38 +/- 0.66 vs. 7.02 +/- 1.18, p <.01), higher high-frequency spectral values (6.89 +/- 0.86 vs. 6.48 +/- 1.44, p <.05), and lower baroreceptor sensitivity (8.62 +/- 8.16 vs. 11.65 +/- 4.42, p <.005) than the healthy subjects. ANOVA showed a significant group interaction (p <.0001) between the samples. CONCLUSIONS: This study provides evidence for abnormal autonomic functioning in patients with erythrophobia when under mental stress.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study the baroreflex sensitivity of conscious, juvenile, spontaneously hypertensive rats (SHRs) was compared. The study population consisted of 19 eight-week-old male SHRs. The baroreflex sensitivity was quantified as the derivative of the variation in heart rate (HR) and the variation of mean arterial pressure (baroreflex sensitivity = Delta HR/Delta MAP). MAP was manipulated with sodium nitroprusside (SNP) and phenylephrine (PHE), administered via an inserted cannula in the right femoral vein. The SHRs were divided into four groups: (1) low bradycardic baroreflex (LB) where the baroreflex gain (BG) was between 0 and 1 bpm/mmHg with PHE; (2) high bradycardic baroreflex (HB), where the BG was < -1 bpm/mmHg with PHE; (3) low tachycardic baroreflex (LT) where the BC was between 0 and 3 bpm/mmHg with SNP; (4) high tachycardic baroreflex (HT) where the BG was > 3 bpm/mmHg with SNP. We noted that 36.8% of the rats presented with an increased bradycardic reflex, while 27.8% demonstrated an attenuated tachycardic reflex. No significant alterations were noted regarding the basal MAP and HR. There were significant differences in the baroreflex sensitivity between SHRs in the same laboratory. One should be careful when interpreting studies employing the SHR as a research model.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A number of mechanisms have been proposed to explain the pleiotropic effect of statin therapy to reduce sympathetic outflow in cardiovascular disease. We tested the hypothesis that statin treatment could improve baroreflex gain-sensitivity triggered by morphological adaptations in the mechanoreceptor site, thus reducing sympathetic activity, regardless of arterial pressure (AP) level reduction. Male spontaneously hypertensive rats (SHR) were divided into control (SHR, n = 8) and SHR-simvastatin (5 mg/kg/day, for 7 days) (SHR-S, n = 8). After treatment, AP, baroreflex sensitivity (BRS) in response to AP-induced changes, aortic depressor nerve activity, and spectral analyses of pulse interval (PI) and AP variabilities were performed. Internal and external carotids were prepared for morphoquantitative evaluation. Although AP was similar between groups, sympathetic modulation, represented by the low frequency band of PI (SHR: 6.84 ± 3.19 vs. SHR-S: 2.41 ± 0.96 msec2) and from systolic AP variability (SHR: 3.95 ± 0.36 vs. SHR-S: 2.86 ± 0.18 mmHg2), were reduced in treated animals. In parallel, simvastatin induced an increase of 26% and 21% in the number of elastic lamellae as well as a decrease of 9% and 25% in the carotid thickness in both, external and internal carotid, respectively. Moreover, improved baroreceptor function (SHR: 0.78 ± 0.03 vs. SHR-S: 1.06 ± 0.04% mv/mmHg) was observed in addition to a 115% increase in aortic depressor nerve activity in SHR-S rats. Therefore, our data suggest that the reduction of sympathetic outflow in hypertension by simvastatin treatment may be triggered by structural changes in the carotid arteries and increased BRS in response to an improvement of the baroreceptors discharge and consequently of the afferent pathway of the baroreflex arch.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To explore the effects of glaucoma and aging on low-spatial-frequency contrast sensitivity by using tests designed to assess performance of either the magnocellular (M) or parvocellular (P) visual pathways. METHODS: Contrast sensitivity was measured for spatial frequencies of 0.25 to 2 cyc/deg by using a published steady- and pulsed-pedestal approach. Sixteen patients with glaucoma and 16 approximately age-matched control subjects participated. Patients with glaucoma were tested foveally and at two midperipheral locations: (1) an area of early visual field loss, and (2) an area of normal visual field. Control subjects were assessed in matched locations. An additional group of 12 younger control subjects (aged 20-35 years) were also tested. RESULTS: Older control subjects demonstrated reduced sensitivity relative to the younger group for the steady (presumed M)- and pulsed (presumed P)-pedestal conditions. Sensitivity was reduced foveally and in the midperiphery across the spatial frequency range. In the area of early visual field loss, the glaucoma group demonstrated further sensitivity reduction relative to older control subjects across the spatial frequency range for both the steady- and pulsed-pedestal tasks. Sensitivity was also reduced in the midperipheral location of "normal" visual field for the pulsed condition. CONCLUSIONS: Normal aging results in a reduction of contrast sensitivity for the low-spatial-frequency-sensitive components of both the M and P pathways. Glaucoma results in a further reduction of sensitivity that is not selective for M or P function. The low-spatial-frequency-sensitive channels of both pathways, which are presumably mediated by cells with larger receptive fields, are approximately equivalently impaired in early glaucoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For the last two decades heart disease has been the highest single cause of death for the human population. With an alarming number of patients requiring heart transplant, and donations not able to satisfy the demand, treatment looks to mechanical alternatives. Rotary Ventricular Assist Devices, VADs, are miniature pumps which can be implanted alongside the heart to assist its pumping function. These constant flow devices are smaller, more efficient and promise a longer operational life than more traditional pulsatile VADs. The development of rotary VADs has focused on single pumps assisting the left ventricle only to supply blood for the body. In many patients however, failure of both ventricles demands that an additional pulsatile device be used to support the failing right ventricle. This condition renders them hospital bound while they wait for an unlikely heart donation. Reported attempts to use two rotary pumps to support both ventricles concurrently have warned of inherent haemodynamic instability. Poor balancing of the pumps’ flow rates quickly leads to vascular congestion increasing the risk of oedema and ventricular ‘suckdown’ occluding the inlet to the pump. This thesis introduces a novel Bi-Ventricular Assist Device (BiVAD) configuration where the pump outputs are passively balanced by vascular pressure. The BiVAD consists of two rotary pumps straddling the mechanical passive controller. Fluctuations in vascular pressure induce small deflections within both pumps adjusting their outputs allowing them to maintain arterial pressure. To optimise the passive controller’s interaction with the circulation, the controller’s dynamic response is optimised with a spring, mass, damper arrangement. This two part study presents a comprehensive assessment of the prototype’s ‘viability’ as a support device. Its ‘viability’ was considered based on its sensitivity to pathogenic haemodynamics and the ability of the passive response to maintain healthy circulation. The first part of the study is an experimental investigation where a prototype device was designed and built, and then tested in a pulsatile mock circulation loop. The BiVAD was subjected to a range of haemodynamic imbalances as well as a dynamic analysis to assess the functionality of the mechanical damper. The second part introduces the development of a numerical program to simulate human circulation supported by the passively controlled BiVAD. Both investigations showed that the prototype was able to mimic the native baroreceptor response. Simulating hypertension, poor flow balancing and subsequent ventricular failure during BiVAD support allowed the passive controller’s response to be assessed. Triggered by the resulting pressure imbalance, the controller responded by passively adjusting the VAD outputs in order to maintain healthy arterial pressures. This baroreceptor-like response demonstrated the inherent stability of the auto regulating BiVAD prototype. Simulating pulmonary hypertension in the more observable numerical model, however, revealed a serious issue with the passive response. The subsequent decrease in venous return into the left heart went unnoticed by the passive controller. Meanwhile the coupled nature of the passive response not only decreased RVAD output to reduce pulmonary arterial pressure, but it also increased LVAD output. Consequently, the LVAD increased fluid evacuation from the left ventricle, LV, and so actually accelerated the onset of LV collapse. It was concluded that despite the inherently stable baroreceptor-like response of the passive controller, its lack of sensitivity to venous return made it unviable in its present configuration. The study revealed a number of other important findings. Perhaps the most significant was that the reduced pulse experienced during constant flow support unbalanced the ratio of effective resistances of both vascular circuits. Even during steady rotary support therefore, the resulting ventricle volume imbalance increased the likelihood of suckdown. Additionally, mechanical damping of the passive controller’s response successfully filtered out pressure fluctuations from residual ventricular function. Finally, the importance of recognising inertial contributions to blood flow in the atria and ventricles in a numerical simulation were highlighted. This thesis documents the first attempt to create a fully auto regulated rotary cardiac assist device. Initial results encourage development of an inlet configuration sensitive to low flow such as collapsible inlet cannulae. Combining this with the existing baroreceptor-like response of the passive controller will render a highly stable passively controlled BiVAD configuration. The prototype controller’s passive interaction with the vasculature is a significant step towards a highly stable new generation of artificial heart.