989 resultados para Ball-bearings


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The friction torque and the operating temperatures in a thrust ball bearing were measured for seven different types of greases, including three biodegradable greases having low toxicity. These friction torque tests were performed using a modified Four-Ball machine. Rheological evaluations of the lubricating greases were made using a rheometer. Bleed oils were extracted from the greases and the dynamic viscosities were measured. In order to compare the performance of the lubricant greases in terms of friction, the grease characteristics were related to experimental results, showing that the interaction between thickener and base oil have strong influences in the bearing friction torque.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thrust ball bearings lubricated with several different types of grease, including three biodegradable low-toxicity greases, were tested in a modified four-ball machine in order to evaluate the bearing friction torque. At the end of each test, grease samples were obtained and analysed through ferrography, allowing the quantification and evaluation of the bearing wear. In order to compare the grease performance in terms of friction and wear, a correlation between the grease characteristics (base oil, bleed oil, thickener structure, and rheological parameters) and the experimental results was established.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thrust ball bearings lubricated with several different greases were tested on a modified Four-Ball Machine, where the Four-Ball arrangement was replaced by a bearing assembly. The friction torque and operating temperatures in a thrust ball bearing were measured during the tests. At the end of each test a grease sample was analyzed through ferrographic techniques in order to quantify and evaluate bearing wear. A rolling bearing friction torque model was used and the coefficient of friction in full film lubrication was determined for each grease, depending on the operating conditions. The experimental results obtained showed that grease formulation had a very significant influence on friction torque and operating temperature. The friction torque depends on the viscosity of the grease base oil, on its nature (mineral, ester, PAO, etc.), on the coefficient of friction in full film conditions, but also on the interaction between grease thickener and base oil, which affected contact replenishment and contact starvation, and thus influenced the friction torque.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"'Principles of ball bearings' ... an abstract of a paper by Mr. Henry Hess".

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Despite use of the best in current design practices, high-speed shaft (HSS) bearings, in a wind-turbine gearbox, continue to exhibit a high rate of premature failure. As HSS bearings operate under low loads and high speeds, these bearings are prone to skidding. However, most of the existing methods for analyzing skidding are quasi-static in nature and cannot be used to study dynamic operating conditions. This paper proposes a dynamic model, which includes gyroscopic and centrifugal effects, to study the skidding characteristics of angular-contact ball-bearings. Traction forces between rolling-elements and raceways are obtained using elastohydrodynamic (EHD) lubrication theory. Underlying gross-sliding mechanisms for pure axial loads, and combined radial and axial loads are also studied. The proposed model will enable engineers to improve bearing reliability at the design stage, by estimating the amount of skidding. © 2011 Published under licence by IOP Publishing Ltd.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The design of bearings, by F.E. Cardullo -- Causes of hot bearings, by E. Kistinger -- Alloys for bearings -- Ball bearings -- Friction of roller bearings, by C.H. Benjamin.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

"Propulsion Laboratory, Contract no. AF 33(600)-22860, Task 3066-30233."

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In order to overcome the interference of the model mounting system with the external aerodynamics of the body during shock tunnel testing, a new free floating internally mountable balance system that ensures unrestrained model motion during testing has been designed, fabricated and tested. Minimal friction ball bearings are used for ensuring the free floating condition of the model during tunnel testing. The drag force acting on a blunt leading edge flat plate at hypersonic Mach number has been measured using the new balance system. Finite element model (FEM) and CFD are exhaustively used in the design as well as for calibrating the new balance system. The experimentally measured drag force on the blunt leading edge flat plate at stagnation enthalpy of 0.7 and 1.2 MJ/kg and nominal Mach number of 5.75 matches well with FEM results. The concept can also be extended for measuring all the three fundamental aerodynamic forces in short duration test facilities like free piston driven shock tunnels.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background

]In modern radiotherapy, it is crucial to monitor the performance of all linac components including gantry, collimation system and electronic portal imaging device (EPID) during arc deliveries. In this study, a simple EPID-based measurement method has been introduced in conjunction with an algorithm to investigate the stability of these systems during arc treatments with the aim of ensuring the accuracy of linac mechanical performance.


Methods

The Varian EPID sag, gantry sag, changes in source-to-detector distance (SDD), EPID and collimator skewness, EPID tilt, and the sag in MLC carriages as a result of linac rotation were separately investigated by acquisition of EPID images of a simple phantom comprised of 5 ball-bearings during arc delivery. A fast and robust software package was developed for automated analysis of image data. Twelve Varian linacs of different models were investigated.


Results

The average EPID sag was within 1 mm for all tested linacs. All machines showed less than 1 mm gantry sag. Changes in SDD values were within 1.7 mm except for three linacs of one centre which were within 9 mm. Values of EPID skewness and tilt were negligible in all tested linacs. The maximum sag in MLC leaf bank assemblies was around 1 mm. The EPID sag showed a considerable improvement in TrueBeam linacs.


Conclusion

The methodology and software developed in this study provide a simple tool for effective investigation of the behaviour of linac components with gantry rotation. It is reproducible and accurate and can be easily performed as a routine test in clinics.




Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study compared pressure and thermal thresholds after administration of three opioids in eight cats. Pressure stimulation was performed via a bracelet taped around the forearm. Three ball-bearings were advanced against the forearm by inflation of a modified blood pressure bladder. Pressure in the cuff was recorded at the end point (leg shake and head turn). Thermal threshold was tested as previously reported using a heated probe held against the thorax [Dixon et al. (2002) Research in Veterinary Science, 72, 205]. After baseline recordings, each cat received subcutaneous methadone 0.2 mg/kg, morphine 0.2 mg/kg, buprenorphine 0.02 mg/kg or saline 0.3 mL in a four period cross-over study. Measurements were made at 15, 30, 45 min and 1, 2, 3, 4, 8, 12 and 24 h after the injection. Data were analysed by ANOVA (P < 0.05). There were no significant changes in thresholds after saline. Thermal threshold increased at 45 min after buprenorphine (maximum 2.8 +/- 3 degrees C), 1-3 h after methadone (maximum 3.4 +/- 1.9 degrees C) and 45 min to 1 h (maximum 3.4 +/- 2 degrees C) after morphine. Pressure threshold increased 30-45 min (maximum 238 +/- 206 mmHg) after buprenorphine, 45-60 min after methadone (maximum 255 +/- 232 mmHg) and 45-60 min and 3-6 h (maximum 255 +/- 232 mmHg) after morphine. Morphine provided the best analgesia, and methadone appears a promising alternative. Buprenorphines limited effect was probably related to the subcutaneous route of administration. Previously, buprenorphine has produced much greater effects when given by other routes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To evaluate a prototype pressure stimulus device for use in the cat and to compare with a known thermal threshold device.Eight healthy adult cats weighing between 3.0 and 4.9 kg.Pressure stimulation was given via a plastic bracelet taped around the forearm. Three 2.4 mm diameter ball bearings, in a 10-mm triangle, were advanced against the craniolateral surface of the antebrachium by manual inflation of a modified blood pressure bladder. Pressure in the cuff was recorded at the end point (leg shake and head turn). Thermal threshold was also tested. Stimuli were stopped if they reached 55 degrees C or 450 mmHg without response. After four pressure and thermal threshold baselines, each cat received SC buprenorphine 0.01 mg kg(-1), carprofen 4 mg kg(-1) or saline 0.3 mL in a three period cross-over study with a 1-week interval. The investigator was blinded to the treatment. Measurements were made at 0.25. 0.5, 0.75, 1, 2, 3, 4, 6, 8, and 24 hours after injection. Data were analyzed by using ANOVA.There were no significant changes in thermal or pressure threshold after administration of saline or carprofen, but thermal threshold increased from 60 minutes until 8 hours after administration of buprenorphine (p < 0.05). The maximum increase in threshold from baseline (Delta T-max) was 3.5 +/- 3.1 degrees C at 2 hours. Pressure threshold increased 2 hours after administration of buprenorphine (p < 0.05) when the increase in threshold above baseline (Delta P-max) was 162 +/- 189 mmHg.This pressure device resulted in thresholds that were affected by analgesic treatment in a similar manner but to a lesser degree than the thermal method. Pressure stimulation may be a useful additional method for analgesic studies in cats.