998 resultados para BREATHING PATTERNS


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents an evaluation of microwave Doppler radar used for capturing different types of breathing patterns in addition to the respiration rate. Finding therespiration rate is equally important as identifying abnormal breathing patterns which it could be used to gain a better insight into respiratory disorders. Various known breathing disorders were role played and captured using a non-contactmicrowave Doppler radar which further supports the feasibility of Doppler radar in obtaining an accurate detection of different types of breathing patterns. The results obtained for all the experiments were compared with a standard measurementapparatus, respiration strap, yielding a good correlations with the Doppler radar signals. In a nutshell, Doppler radar can be potentially used as an alternative approach, not only for finding the respiration rates, but also for identifying respiration patterns replacing the conventional contact methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To assess the response of healthy infants to airway hypoxia (15% oxygen in nitrogen).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study investigated the effect of sleep position on breathing patterns of normal full term infants during quiet and active behavioral sleep states. Tidal volume, percent contribution of rib cage to tidal volume, and respiration rate were measured via respiratory inductive plethysmography (RIP) and pneumotachograph (PNT) in ten infants sleeping in supine versus right side-lying. Data was collected immediately following two consecutive feedings. Paired t tests and ANOVA comparisons showed no significant differences between the two postures (p $<$.05) in mean tidal volume (supine, M = 19.16, right side, M = 22.45), percent contribution of rib cage to tidal volume (supine, M = 30.55, right side M = 33.20), or respiration rate (supine, M = 49.13, right side, M = 49.37) during quiet sleep. Comparisons also showed no significant differences between the two postures (p $<$.05) in mean tidal volume (supine, M = 18.89, right side, M = 20.12), percent contribution of rib cage to tidal volume (supine, M = 6.43, right side, M = 6.97) or respiration rate (supine, M = 62.18, right side, M = 61.04) during active sleep. Therefore, no differences were found in the three respiratory variables measured between the supine and right side-lying positions. These findings suggest that infants may be positioned in either sleep position without detriment to respiratory function. This information may benefit occupational therapists and other health professionals involved in the education of parents on infant positioning and their respective advantages. ^

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper reports on the analysis of tidal breathing patterns measured during noninvasive forced oscillation lung function tests in six individual groups. The three adult groups were healthy, with prediagnosed chronic obstructive pulmonary disease, and with prediagnosed kyphoscoliosis, respectively. The three children groups were healthy, with prediagnosed asthma, and with prediagnosed cystic fibrosis, respectively. The analysis is applied to the pressure–volume curves and the pseudophaseplane loop by means of the box-counting method, which gives a measure of the area within each loop. The objective was to verify if there exists a link between the area of the loops, power-law patterns, and alterations in the respiratory structure with disease. We obtained statistically significant variations between the data sets corresponding to the six groups of patients, showing also the existence of power-law patterns. Our findings support the idea that the respiratory system changes with disease in terms of airway geometry and tissue parameters, leading, in turn, to variations in the fractal dimension of the respiratory tree and its dynamics.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper reports on the analysis of tidal breathing patterns measured during noninvasive forced oscillation lung function tests in six individual groups. The three adult groups were healthy, with prediagnosed chronic obstructive pulmonary disease, and with prediagnosed kyphoscoliosis, respectively. The three children groups were healthy, with prediagnosed asthma, and with prediagnosed cystic fibrosis, respectively. The analysis is applied to the pressure-volume curves and the pseudophase-plane loop by means of the box-counting method, which gives a measure of the area within each loop. The objective was to verify if there exists a link between the area of the loops, power-law patterns, and alterations in the respiratory structure with disease. We obtained statistically significant variations between the data sets corresponding to the six groups of patients, showing also the existence of power-law patterns. Our findings support the idea that the respiratory system changes with disease in terms of airway geometry and tissue parameters, leading, in turn, to variations in the fractal dimension of the respiratory tree and its dynamics.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

 Noncontact detection characteristic of Doppler radar provides an unobtrusive means of respiration detection and monitoring. This avoids additional preparations, such as physical sensor attachment or special clothing, which can be useful for certain healthcare applications. Furthermore, robustness of Doppler radar against environmental factors, such as light, ambient temperature, interference from other signals occupying the same bandwidth, fading effects, reduce environmental constraints and strengthens the possibility of employing Doppler radar in long-term respiration detection, and monitoring applications such as sleep studies. This paper presents an evaluation in the of use of microwave Doppler radar for capturing different dynamics of breathing patterns in addition to the respiration rate. Although finding the respiration rate is essential, identifying abnormal breathing patterns in real-time could be used to gain further insights into respiratory disorders and refine diagnostic procedures. Several known breathing disorders were professionally role played and captured in a real-time laboratory environment using a noncontact Doppler radar to evaluate the feasibility of this noncontact form of measurement in capturing breathing patterns under different conditions associated with certain breathing disorders. In addition to that, inhalation and exhalation flow patterns under different breathing scenarios were investigated to further support the feasibility of Doppler radar to accurately estimate the tidal volume. The results obtained for both experiments were compared with the gold standard measurement schemes, such as respiration belt and spirometry readings, yielding significant correlations with the Doppler radar-based information. In summary, Doppler radar is highlighted as an alternative approach not only for determining respiration rates, but also for identifying breathing patterns and tidal volumes as a preferred nonwearable alternative to the conventional - ontact sensing methods.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The primary role of the respiratory system is to ensure adequate tissue oxygenation, eliminate carbon dioxide and help to regulate acid-base status. To maintain this homeostasis, amphibians possess an array of receptors located at peripheral and central chemoreceptive sites that sense respiration-related variables in both internal and external environments. As in mammals, input from these receptors is integrated at central rhythmogenic and pattern-forming elements in the medulla in a manner that meets the demands determined by the environment within the constraints of the behavior and breathing pattern of the animal. Also as in mammals, while outputs from areas in the midbrain may modulate respiration directly, they do not play a significant role in the production of the normal respiratory rhythm. However, despite these similarities, the breathing patterns of the two classes are different: mammals maintain homeostasis of arterial blood gases through rhythmic and continuous breathing, whereas amphibians display an intermittent pattern of aerial respiration. While the latter is also often rhythmic, it allows a degree of fluctuation in key respiratory variables that has led some to suggest that control is not as tight in these animals. In this review we will focus specifically on recent advances in studies of the control of ventilation in anuran amphibians. This is the group of amphibians that has attracted the most recent attention from respiratory physiologists. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This work investigates the performance of cardiorespiratory analysis detecting periodic breathing (PB) in chest wall recordings in mountaineers climbing to extreme altitude. The breathing patterns of 34 mountaineers were monitored unobtrusively by inductance plethysmography, ECG and pulse oximetry using a portable recorder during climbs at altitudes between 4497 and 7546 m on Mt. Muztagh Ata. The minute ventilation (VE) and heart rate (HR) signals were studied, to identify visually scored PB, applying time-varying spectral, coherence and entropy analysis. In 411 climbing periods, 30-120 min in duration, high values of mean power (MP(VE)) and slope (MSlope(VE)) of the modulation frequency band of VE, accurately identified PB, with an area under the ROC curve of 88 and 89%, respectively. Prolonged stay at altitude was associated with an increase in PB. During PB episodes, higher peak power of ventilatory (MP(VE)) and cardiac (MP(LF)(HR) ) oscillations and cardiorespiratory coherence (MP(LF)(Coher)), but reduced ventilation entropy (SampEn(VE)), was observed. Therefore, the characterization of cardiorespiratory dynamics by the analysis of VE and HR signals accurately identifies PB and effects of altitude acclimatization, providing promising tools for investigating physiologic effects of environmental exposures and diseases.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Aerosol production during normal breathing is often attributed to turbulence in the respiratory tract. That mechanism is not consistent with a high degree of asymmetry between aerosol production during inhalation and exhalation. The objective was to investigate production symmetry during breathing. Methods: The aerosol size distribution in exhaled breath was examined for different breathing patterns including normal breathing, varied breath holding periods and contrasting inhalation and exhalation rates. The aerosol droplet size distribution measured in the exhaled breath was examined in real time using an aerodynamic particle sizer. Results and Conclusions: The dependence of the particle concentration decay rate on diameter during breath holding was consistent with gravitational settling in the alveolar spaces. Also, deep exhalation resulted in a 4 to 6 fold increase in concentration and rapid inhalation produced a further 2 to 3 fold increase in concentration. In contrast rapid exhalation had little effect on the measured concentration. A positive correlation of the breath aerosol concentration with subject age was observed. The results were consistent with the breath aerosol being produced through fluid film rupture in the respiratory bronchioles in the early stages of inhalation and the resulting aerosol being drawn into the alveoli and held before exhalation. The observed asymmetry of production in the breathing cycle with very little aerosol being produced during exhalation, is inconsistent with the widely assumed turbulence induced aerosolization mechanism.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Abstract—The role of cardiopulmonary signals in the dynamics of wavefront aberrations in the eye has been examined. Synchronous measurement of the eye’s wavefront aberrations, cardiac function, blood pulse, and respiration signals were taken for a group of young, healthy subjects. Two focusing stimuli, three breathing patterns, as well as natural and cycloplegic eye conditions were examined. A set of tools, including time–frequency coherence and its metrics, has been proposed to acquire a detailed picture of the interactions of the cardiopulmonary system with the eye’s wavefront aberrations. The results showed that the coherence of the blood pulse and its harmonics with the eye’s aberrations was, on average, weak (0.4 ± 0.15), while the coherence of the respiration signal with eye’s aberrations was, on average, moderate (0.53 ± 0.14). It was also revealed that there were significant intervals during which high coherence occurred. On average, the coherence was high (>0.75) during 16% of the recorded time, for the blood pulse, and 34% of the time for the respiration signal. A statistically significant decrease in average coherence was noted for the eye’s aberrations with respiration in the case of fast controlled breathing (0.5 Hz). The coherence between the blood pulse and the defocus was significantly larger for the far target than for the near target condition. After cycloplegia, the coherence of defocus with the blood pulse significantly decreased, while this was not the case for the other aberrations. There was also a noticeable, but not statistically significant, increase in the coherence of the comatic term and respiration in that case. By using nonstationary measures of signal coherence, a more detailed picture of interactions between the cardiopulmonary signals and eye’s wavefront aberrations has emerged.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper, the design and development of a novel low-cost, non-invasive type sensor suitable for human breath sensing is reported. It can be used to detect respiratory disorders like bronchial asthma by analyzing the recorded breathing pattern. Though there are devices like spirometer to diagnose asthma, they are very inconvenient for patient's use because patients are made to exhale air through mouth forcefully. Presently developed sensor will overcome this limitation and is helpful in the diagnosis of respiratory related abnormalities. Polyvinylidene fluoride (PVDF) film in cantilever configuration is used as a sensing element to form the breath sensor. Two identical sensors are mounted on a spectacle frame, such that the tidal flow of inhaled and exhale air will impinge on sensor, for sensing the breathing patterns. These patterns are recorded, filtered, analyzed and displayed using CRO. Further the sensor is calibrated using a U-tube water manometer. The added advantage of piezoelectric type sensing element is that it is self powered without the need of any external power source.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Bien que la douleur soit une expérience subjective universelle, la façon de la percevoir et de l’interpréter est modulée par une multitude de facteurs. Plusieurs interventions cognitives se sont montrées efficaces pour réduire la douleur dans des conditions cliniques et expérimentales. Cette thèse s’intéressera particulièrement aux mécanismes psychophysiologiques impliqués dans les stratégies de modulation volontaire de la douleur. Ces stratégies sont intéressantes puisqu’elles encouragent une prise en charge par l’individu, lui permettant de jouer un rôle actif dans la régulation de sa douleur. La première étude s’intéresse à l’efficacité du biofeedback comme moyen de modulation volontaire de la douleur. Il s’agissait de déterminer si le fait de présenter une rétroaction de l’amplitude du réflex RIII (évoqué par une stimulation électrique du nerf sural) au cours d’un entraînement de plusieurs essais permettrait au participant d’adopter des stratégies de modulation de la douleur et d’activer volontairement des mécanismes de contrôle descendant de la douleur. De façon à évaluer spécifiquement les changements induits par le biofeedback, la modulation du réflexe RIII et de la douleur était comparée dans trois groupes (biofeedback valide, faux biofeedback et groupe contrôle sans rétroaction). Dans les trois groupes, il était suggéré aux participants d’utiliser des stratégies cognitives de modulation de la douleur (attention, modulation de la respiration, réévaluation cognitive et imagerie mentale) afin d’augmenter ou de diminuer leur réflexe RIII comparativement à leur niveau de base. Les résultats de notre étude indiquent que les participants des 3 groupes ont réussi à moduler leur réflexe RIII (p<0,001) ainsi que leurs évaluations de douleur (p<0,001) (intensité et désagrément). Les résultats de notre étude montrent que l’entraînement au biofeedback n’était pas nécessaire pour obtenir une modulation du réflexe RIII et de la douleur, ce qui suggère que l’utilisation de stratégies cognitives pourrait être suffisante pour déclencher des mécanismes de contrôle de la douleur. La deuxième étude découle de la première et s’intéressait à l’influence de la fréquence et de la phase respiratoire sur la nociception spinale, l’activité cérébrale et la perception de douleur. Le contrôle volontaire de la respiration est un moyen commun de régulation des émotions et est fréquemment utilisé en combinaison avec d’autres techniques (ex. : relaxation, méditation) dans le but de réguler la douleur. Les participants étaient invités à synchroniser leur respiration à des indices sonores indiquant le moment de l’inspiration et de l’expiration. Trois patrons de respiration étaient proposés (respiration à 0,1Hz avec une inspiration de 4 secondes, respiration à 0,1Hz avec une inspiration de 2 secondes et respiration à 0,2Hz avec une inspiration de 2 secondes. La moitié des stimulations étaient données durant l’inspiration et l’autre moitié durant l’expiration. Afin d’évaluer l’effet de ces manipulations, l’amplitude du RIII, l’évaluation subjective d’intensité de la douleur et de l’anxiété suscitée par le choc en plus des potentiels évoqués étaient mesurés. Les résultats de cette étude démontrent que les évaluations d’intensité de la douleur n’étaient pas affectées par le patron respiratoire (p=0,3), mais étaient statistiquement plus basses durant l’inspiration comparativement à l’expiration (p=0,02). Un effet de phase (p=0,03) était également observé sur les potentiels évoqués durant la condition de respiration à 0,1hHz avec une inspiration de 2 secondes comparativement au patron de respiration de 0,2Hz. Paradoxalement, l’amplitude du réflexe RIII était augmenté durant l’inspiration (p=0,02) comparativement à l’expiration. Ces résultats montrent que la manipulation de la fréquence et de la phase respiratoires (par une synchronisation imposée) a un effet marginal sur les évaluations de douleur et sur l’activité cérébrale et spinale évoquée par une stimulation électrique (douleur aigüe). Cela suggère que d’autres mécanismes contribuent aux effets analgésiques observés dans la relaxation et la méditation. Plus largement, nos résultats font état de la nécessité d’études plus approfondies avec une méthodologie plus rigoureuse afin de contrôler les effets non spécifiques aux traitements évalués. Une meilleure connaissance des mécanismes sous-tendant chaque stratégie permettrait de mieux cibler les clientèles susceptibles d’y répondre et de mieux considérer le ratio coût bénéfice de chaque traitement.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper further investigates the use of Doppler radar for detecting and identifying certain human respiratory characteristics from observed frequency and phase modulations. Specifically, we show how breathing frequencies can be determined from the demodulated signal leading to identifying abnormalities of breathing patterns using signal derivatives, optimal filtering and standard statistical measures. Specifically, we report results on a robust method for distinguishing cessation of the normal breathing cycle. The proposed approach can have potential application in the management of sudden infant death syndrome(SIDS) and sleep apnea.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents the preliminary results of our work in detecting respiration using Doppler Radar in the 2.7 GHz operating band. We demonstrate the capability of Doppler Radar in capturing breathing patterns under various breathing forms such as normal breathing, fast breathing, as well as different rate of inhale and exhale. From the captured signals, respiration rate was obtained using Fast Fourier Transform and validated. The proposed approach could potentially be used in number of applications involving breathing rate and breathing pattern analysis via non-contact methods.