999 resultados para BEATING HEART
Resumo:
OBJECTIVES: Residual mitral regurgitation after valve repair worsens patients' clinical outcome. Postimplant adjustable mitral rings potentially address this issue, allowing the reshaping of the annulus on the beating heart under echocardiography control. We developed an original mitral ring allowing valve geometry remodelling after the implantation and designed an animal study to assess device effectiveness in correcting residual mitral regurgitation. METHODS: The device consists of two concentric rings: one internal and flexible, sutured to the mitral annulus and a second external and rigid. A third conic element slides between the two rings, modifying the shape of the flexible ring. This sliding element is remotely activated with a rotating tool. Animal model: in adult swine, under cardio pulmonary bypass and cardiac arrest, we shortened the primary chordae of P2 segment to reproduce Type III regurgitation and implanted the active ring. We used intracardiac ultrasound to assess mitral regurgitation and the efficacy of the active ring to correct it. RESULTS: Severe mitral regurgitation (3+ and 4+) was induced in eight animals, 54 ± 6 kg in weight. Vena contracta width decreased from 0.8 ± 0.2 to 0.1 cm; proximal isovelocity surface area radius decreased from 0.8 ± 0.2 to 0.1 cm and effective regurgitant orifice area decreased from 0.50 ± 0.1 to 0.1 ± 0.1 cm(2). Six animals had a reversal of systolic pulmonary flow that normalized following the activation of the device. All corrections were reversible. CONCLUSIONS: Postimplant adjustable mitral ring corrects severe mitral regurgitation through the reversible modification of the annulus geometry on the beating heart. It addresses the frequent and morbid issue of recurrent mitral valve regurgitation.
Resumo:
BACKGROUND: Cardiopulmonary bypass (CPB) with aortic cross-clamping and cardioplegic arrest remains the method of choice for patients requiring standard myocardial revascularization. Therefore, very high-risk patients presenting with acute coronary syndrome, unstable angina, onset of cardiac decompensation and requiring emergency multiple myocardial revascularization, can have a poor outcome. The on-pump beating heart technique can reduce the mortality and the morbidity in such a selected group of patients and this report describes our clinical experience. METHODS: Out of 290 patients operated for CABG from January 2005 to January 2006, 25 (8.6%) selected high-risk patients suffering from life threatening coronary syndrome (mean age 69 +/- 7 years) and requiring emergency multiple myocardial revascularization, underwent on-pump beating heart surgery. The mean pre-operative left ventricle ejection fraction (LVEF) was 27 +/- 8%. The majority of them (88%) suffered of tri-vessel coronary disease and 6 (24%) had a left main stump disease. Nine patients (35%) were on severe cardiac failure and seven among them (28%) received a pre-operative intra-aortic balloon pump. The pre-operative EuroScore rate was equal or above 8 in 18 patients (73%). RESULTS: All patients underwent on-pump-beating heart coronary revascularization. The mean number of graft/patient was 2.9 +/- 0.6 and the internal mammary artery was used in 23 patients (92%). The mean CPB time was 84 +/- 19 minutes. Two patients died during the recovery stay in the intensive care unit, and there were no postoperative myocardial infarctions between the survivors. Eight patients suffered of transitorily renal failure and 1 patient developed a sternal wound infection. The mean hospital stay was 12 +/- 7 days. The follow-up was complete for all 23 patients survived at surgery and the mean follow-up time was 14 +/- 5 months. One patient died during the follow-up for cardiac arrest and 2 patients required an implantable cardiac defibrillator. One year after surgery they all had a standard trans-thoracic echocardiogram showing a mean LVEF rate of 36 +/- 11.8%. CONCLUSION: Standard on-pump arrested heart coronary surgery has higher mortality and morbidity in emergencies. The on-pump beating heart myocardial revascularization seems to be a valid alternative for the restricted and selected cohort of patients suffering from life threatening coronary syndrome and requiring multiple emergency CABG.
Resumo:
Gene therapy may represent a promising alternative strategy for cardiac muscle regeneration. In vivo electroporation, a physical method of gene transfer, has recently evolved as an efficient method for gene transfer. In the current study, we investigated the efficiency and safety of a protocol involving in vivo electroporation for gene transfer to the beating heart. Adult male rats were anesthetised and the heart exposed through a left thoracotomy. Naked plasmid DNA was injected retrograde into the transiently occluded coronary sinus before the electric pulses were applied. Animals were sacrificed at specific time points and gene expression was detected. Results were compared to the group of animals where no electric pulses were applied. No post-procedure arrhythmia was observed. Left ventricular function was temporarily altered only in the group were high pulses were applied; CK-MB (Creatine kinase) and TNT (Troponin T) were also altered only in this group. Histology showed no signs of toxicity. Gene expression was highest at day one. Our results provide evidence that in vivo electroporation with an optimized protocol is a safe and effective tool for nonviral gene delivery to the beating heart. This method may be promising for clinical settings especially for perioperative gene delivery.
Resumo:
Gene therapy of the heart has been attempted in a number of clinical trials with the injection of naked DNA, although quantitative information on myocellular transfection rates is not available. The present study aimed to quantify the efficacy of electropulsing protocols that differ in pulse duration and number to stimulate transfection of cardiomyocytes and to determine the impact on myocardial integrity.
Resumo:
Energy-harvesting devices attract wide interest as power supplies of today's medical implants. Their long lifetime will spare patients from repeated surgical interventions. They also offer the opportunity to further miniaturize existing implants such as pacemakers, defibrillators or recorders of bio signals. A mass imbalance oscillation generator, which consists of a clockwork from a commercially available automatic wrist watch, was used as energy harvesting device to convert the kinetic energy from the cardiac wall motion to electrical energy. An MRI-based motion analysis of the left ventricle revealed basal regions to be energetically most favorable for the rotating unbalance of our harvester. A mathematical model was developed as a tool for optimizing the device's configuration. The model was validated by an in vitro experiment where an arm robot accelerated the harvesting device by reproducing the cardiac motion. Furthermore, in an in vivo experiment, the device was affixed onto a sheep heart for 1 h. The generated power in both experiments-in vitro (30 μW) and in vivo (16.7 μW)-is sufficient to power modern pacemakers.
Resumo:
Gene therapy may represent a promising alternative strategy for cardiac muscle regeneration. In vivo electroporation, a physical method of gene transfer, has recently evolved as an efficient method for gene transfer. Here, we describe two protocols involving in vivo electroporation for gene transfer to the beating heart.
Resumo:
In an atmosphere of crisis, distrust and fragmentation, policy-makers in Brussels are mostly focused on fighting fire without having an ambitious vision for the future – in effect, muddling through, as has been the characteristic response in recent years. However, by remaining in crisis response mode, the European Union (EU) is failing to provide the basis for the compromise politics that can get the European system out of the current impasse: the EU needs to be engaged in a positive sum game to ensure that countries see an incentive for making deals.
Resumo:
Oxygen-derived free radicals are important agents of tissue injury during ischemia and reperfusion. The aim of this study was to investigate changes in protein and lipid oxidation and antioxidant status in beating heart coronary artery surgery and conventional bypass and to compare oxidative stress parameters between the two bypass methods. Serum lipid hydroperoxide, nitric oxide, protein carbonyl, nitrotyrosine, vitamin E, and β-carotene levels and total antioxidant capacity were measured in blood of 30 patients undergoing beating heart coronary artery surgery (OPCAB, off-pump coronary artery bypass grafting) and 12 patients undergoing conventional bypass (CABG, on-pump coronary artery bypass grafting). In the OPCAB group, nitric oxide and nitrotyrosine levels decreased after reperfusion. Similarly, β-carotene level and total antioxidant capacity also decreased after anesthesia and reperfusion. In the CABG group, nitric oxide and nitrotyrosine levels decreased after ischemia and reperfusion. However, protein carbonyl levels elevated after ischemia and reperfusion. Vitamin E, β-carotene, and total antioxidant capacity decreased after ischemia and reperfusion. Significantly decreased nitration and impaired antioxidant status were seen after reperfusion in both groups. Moreover, elevated protein carbonyls were found in the CABG group. The off-pump procedure is associated with lower degree of oxidative stress than on-pump coronary surgery. © 2011 Pleiades Publishing, Ltd.
Resumo:
We previously established that exogenous adenosine (ADO) induces transient arrhythmias in the developing heart via the adenosine A1 receptor (A1AR) and downstream activation of NADPH oxidase/ERK and PLC/PKC pathways. Here, we investigated the mechanisms by which accumulation of endogenous ADO and its derived compound inosine (INO) in the interstitial compartment induce rhythm and conduction troubles. The validated model of the spontaneously beating heart obtained from 4-day-old chick embryos was used. Quantitative RT-PCR showed that enzymes involved in ADO and INO metabolism (CD39, CD73 and eADA) as well as equilibrative (ENT1, -3, -4) and concentrative (CNT3) nucleoside transporters were differentially expressed in atria, ventricle and outflow tract. Inactivation of ENTs by dipyridamole, 1) increased myocardial ADO level, 2) provoked atrial arrhythmias and atrio-ventricular blocks (AVB) in 70% of the hearts, 3) prolonged P wave and QT interval without altering contractility, and 4) increased ERK2 phosphorylation. Blockade of CD73-mediated phosphohydrolysis of AMP to ADO, MEK/ERK pathway inhibition or A1AR inhibition prevented these arrhythmias. Exposure to exogenous INO also caused atrial ectopy associated with AVB and ERK2 phosphorylation which were prevented by A1AR or A2AAR antagonists exclusively or by MEK/ERK inhibitor. Inhibition of ADA-mediated conversion of ADO to INO increased myocardial ADO and decreased INO as expected, but slightly augmented heart rate variability without provoking AVB. Thus, during cardiogenesis, disturbances of nucleosides metabolism and transport, can lead to interstitial accumulation of ADO and INO and provoke arrhythmias in an autocrine/paracrine manner through A1AR and A2AAR stimulation and ERK2 activation.
Resumo:
Background and objectives: Cardiac positioning and stabilization during myocardial revascularization without extracorporeal circulation (ECC) may cause hemodynamic changes dependent to the surgical site. The objective of this study was to evaluate these changes during distal coronary anastomosis. Methods: Twenty adult patients undergoing myocardial revascularization without ECC were monitored by pulmonary artery catheter and transesophageal Echo Doppler. Hemodynamic data were collected at the following times before removing the stabilizer wall: (1) after volume adjustments, (2) at the beginning of distal anastomosis, and (3) after 5 minutes. Treated coronary arteries were grouped according to their location in the lateral, anterior, or posterior wall. Two-way ANOVA with repetition and Newman-Keuls post-test were used in the analysis. A p value < 0.05 was considered statically significant. Results: During myocardial revascularization without ECC, pulmonary artery wedge pressure showed elevation from 17.7 +/- 6.1 to 19.2 +/- 6.5 (p < 0.001) and 19.4 +/- 5.9 mmHg (p < 0.001), while the central venous pressure went from 13.9 +/- 5.4 to 14.9 +/- 5.9 mmHg (p = 0.007) and 15.1 +/- 6.0 mmHg (p = 0.006). Intermittent cardiac output was reduced from 4.70 +/- 1.43 to 4.23 +/- 1.22 (p < 0.001) and 4.26 +/- 1.25 L.min(-1) (p < 0.001). According to transesophageal Doppler, a significant group-time interaction was observed in cardiac output, which was reduced in the lateral group from 4.08 +/- 1.99 to 2.84 +/- 1.82 (p = 0.02) and 2.86 +/- 1.73 L.min(-1) (p = 0.02), and aortic blood flow, which went from 2.85 +/- 1.39 to 1.99 +/- 1.26 (p = 0.02) and 2.00 +/- 1.21 L.min(-1) (p = 0.02). Other hemodynamic changes were not observed during anastomoses. Conclusions: A significant hemodynamic deterioration was observed during myocardial revascularization without ECC. Transesophageal Doppler detected a decrease in cardiac output only in the lateral group.
Resumo:
The MASS III Trial is a large project from a single institution, The Heart Institute of the University of Sao Paulo, Brazil (InCor), enrolling patients with coronary artery disease and preserved ventricular function. The aim of the MASS III Trial is to compare medical effectiveness, cerebral injury, quality of life, and the cost-effectiveness of coronary surgery with and without of cardiopulmonary bypass in patients with multivessel coronary disease referred for both strategies. The primary endpoint should be a composite of cardiovascular mortality, cerebrovascular accident, nonfatal myocardial infarction, and refractory angina requiring revascularization. The secondary end points in this trial include noncardiac mortality, presence and severity of angina, quality of life based on the SF-36 Questionnaire, and cost-effectiveness at discharge and at 5-year follow-up. In this scenario, we will analyze the cost of the initial procedure, hospital length of stay, resource utilization, repeat hospitalization, and repeat revascularization events during the follow-up. Exercise capacity will be assessed at 6-months, 12-months, and the end of follow-up. A neurocognitive evaluation will be assessed in a subset of subjects using the Brain Resource Center computerized neurocognitive battery. Furthermore, magnetic resonance imaging will be made to detect any cerebral injury before and after procedures in patients who undergo coronary artery surgery with and without cardiopulmonary bypass.
Resumo:
A crucial method for investigating patients with coronary artery disease (CAD) is the calculation of the left ventricular ejection fraction (LVEF). It is, consequently, imperative to precisely estimate the value of LVEF--a process that can be done with myocardial perfusion scintigraphy. Therefore, the present study aimed to establish and compare the estimation performance of the quantitative parameters of the reconstruction methods filtered backprojection (FBP) and ordered-subset expectation maximization (OSEM). Methods: A beating-heart phantom with known values of end-diastolic volume, end-systolic volume, and LVEF was used. Quantitative gated SPECT/quantitative perfusion SPECT software was used to obtain these quantitative parameters in a semiautomatic mode. The Butterworth filter was used in FBP, with the cutoff frequencies between 0.2 and 0.8 cycles per pixel combined with the orders of 5, 10, 15, and 20. Sixty-three reconstructions were performed using 2, 4, 6, 8, 10, 12, and 16 OSEM subsets, combined with several iterations: 2, 4, 6, 8, 10, 12, 16, 32, and 64. Results: With FBP, the values of end-diastolic, end-systolic, and the stroke volumes rise as the cutoff frequency increases, whereas the value of LVEF diminishes. This same pattern is verified with the OSEM reconstruction. However, with OSEM there is a more precise estimation of the quantitative parameters, especially with the combinations 2 iterations × 10 subsets and 2 iterations × 12 subsets. Conclusion: The OSEM reconstruction presents better estimations of the quantitative parameters than does FBP. This study recommends the use of 2 iterations with 10 or 12 subsets for OSEM and a cutoff frequency of 0.5 cycles per pixel with the orders 5, 10, or 15 for FBP as the best estimations for the left ventricular volumes and ejection fraction quantification in myocardial perfusion scintigraphy.
Resumo:
OBJECTIVE: This study evaluated the effects of a new method of mitral valve replacement on left ventricular (LV) remodeling and heart failure functional class. METHODS: Eight patients (6 men) with severe mitral regurgitation from end-stage dilated cardiomyopathy underwent surgery. Five patients were in functional class (FC) IV, 2 were in FC III and 1 was in FC III/IV. Age ranged from 33 to 63 years. Both the anterior and posterior leaflets of the mitral valve were divided into hemileaflets. The resultant 4 pedicles were displaced under traction toward the left atrium and anchored between the mitral annulus and an implanted valvular prosthesis. The beating heart facilitated ideal chordae tendineae positioning. RESULTS: All patients survived and were discharged from the hospital. After a mean follow-up period of 6.5 months (1-12 m), 5 patients were in FC I; 2 in FC I/II; and 1 in FC II. The preoperative ejection fraction ranged from 19% to 30% (mean: 25.7±3.4 %), and the postoperative ejection fraction ranged from 21% to 40% (mean: 31.1± 5.8%). Doppler echocardiography showed evidence of LV remodeling in 4 patients, including lateral wall changes and a tendency of the LV cavity to return to its elliptical shape. CONCLUSION: This technique of mitral valve replacement, involving new positioning of the chordae tendineae, allowed LV remodeling and improvement in FC during this brief follow-up period.
Resumo:
Image quality in magnetic resonance imaging (MRI) is considerably affected by motion. Therefore, motion is one of the most common sources of artifacts in contemporary cardiovascular MRI. Such artifacts in turn may easily lead to misinterpretations in the images and a subsequent loss in diagnostic quality. Hence, there is considerable research interest in strategies that help to overcome these limitations at minimal cost in time, spatial resolution, temporal resolution, and signal-to-noise ratio. This review summarizes and discusses the three principal sources of motion: the beating heart, the breathing lungs, and bulk patient movement. This is followed by a comprehensive overview of commonly used compensation strategies for these different types of motion. Finally, a summary and an outlook are provided.