984 resultados para B-mode Ultrasound


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to analyze the thickness of the intima-media complex (IMC) using a noninvasive method. The carotid and femoral common arteries were evaluated by noninvasive B-mode ultrasound in 63 normotensive and in 52 hypertensive subjects and the thickness of the IMC was tested for correlation with blood pressure, cardiac structures and several clinical and biological parameters. The IMC was thicker in hypertensive than in normotensive subjects (0.67 ± 0.13 and 0.62 ± 0.16 vs 0.54 ± 0.09 and 0.52 ± 0.11 mm, respectively, P<0.0001). In normotensive patients, the simple linear regression showed significant correlations between IMC and age, body mass index and 24-h systolic blood pressure for both the carotid and femoral arteries. In hypertensives the carotid IMC was correlated with age and 24-h systolic blood pressure while femoral IMC was correlated only with 24-h diastolic blood pressure. Forward stepwise regression showed that age, body mass index and 24-h systolic blood pressure influenced the carotid IMC relationship (r2 = 0.39) in normotensives. On the other hand, the femoral IMC relationship was influenced by 24-h systolic blood pressure and age (r2 = 0.40). In hypertensives, age and 24-h systolic blood pressure were the most important determinants of carotid IMC (r2 = 0.37), while femoral IMC was influenced only by 24-h diastolic blood pressure (r2 = 0.10). There was an association between carotid IMC and echocardiographic findings in normotensives, while in hypertensives only the left posterior wall and interventricular septum were associated with femoral IMC. We conclude that age and blood pressure influence the intima-media thickness, while echocardiographic changes are associated with the IMC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O objetivo deste estudo foi estabelecer o tempo de prenhez da paca por meio de ultra-sonografia. Nove pacas prenhes foram periodicamente acompanhadas com um transdutor eletrônico setorial bi-frequencial de 5,0 e 7,5 MHz, em modo B, desde a detecção ultra-sonográfica da vesícula embrionária ou do feto até o nascimento dos filhotes. Os animais foram colocados em uma gaiola de ferro de prensagem lateral e permaneceram em posição quadrupedal durante as sessões. Um pano escuro foi usado para cobrir a gaiola e frutas foram oferecidas durante o exame ultra-sonográfico para evitar reações agressivas. Quanto mais precocemente ocorreu a detecção de prenhez, maior foi o período de acompanhamento ultra-sonográfico até o nascimento dos filhotes. Apenas um filhote nasceu por parto, com 796,5 ± 74,36 gramas (valor médio ± desvio padrão da amostra) e 33,46 ± 0,60 centímetros (valor médio ± desvio padrão da amostra) de comprimento (entre a borda rostral do focinho e a extremidade distal da cauda). O período de prenhez da paca abrange 135 a 139 dias.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Gynecological and obstetrical ultrasonography has become an indispensable tool in the routine management, health evaluation and research on captive non-human primates.Methods Ultrasound was used to evaluate the uterus and estimate the gestation of owl monkeys. Twelve couples were selected, where five were primiparous and seven multiparous females from the National Primate Center reproductive colony, Ananindeua-PA, Brazil. The procedures were carried out using the GE (R) Logiq 100 MP, equipped with a 7.5 MHz linear probe.Results the females showed a simple uterus, of elongated shape, regular outline and homogeneous echogenic texture. In the uterine measurements craniocaudal diameter, dorsoventral diameter and uterine volume (UV), significant differences were identified (P < 0.05) between ultrasound examinations of primiparous and multiparous females. The UV showed a positive correlation with the number of births. The gestational sac and the embryonic echo were visible between 28 and 38 days after mating. Between 48 and 68 days after mating, embryonic death was identified in all the gestations.Conclusions the chemical (use of tranquilizers) and husbandry factors (capture stress) may be related to the prenatal death. The establishing methods of conditioning the female to the ultrasonographic exam may offer a solution to this problem.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lower gastrointestinal tract neoplasms are rare in domestic animals, representing 3% of all biopsies and necropsies. Our objective is to describe the histopathological and B-mode ultrasound findings in a case of duodenal adenocarcinoma in a dog, since it commonly occurs in the large intestine. On ultrasound examination, there was transmural wall thickening in the duodenum with loss of layer structure, focal peritonitis and adenopathy. Histopathological examination of the intestinal mass revealed a malignant epithelial neoplasm, densely cellular and infiltrative, extending through the lamina propria, submucosa, muscle and hypodermis, characterizing a duodenal adenocarcinoma. We conclude that adenocarcinomas may be included in the differential diagnosis of transmural lesions in the duodenum in B-mode ultrasound examinations, but a laparotomy and biopsy are required for definitive diagnosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ultrasound (B-mode) was used to analyze follicular events in 12 trained female owl monkeys (Aotus azarai infulatus). The animals were examined every 48 hours for over 90days to measure and map follicular growth in both ovaries and to measure (using Doppler velocimetry) local hemodynamic changes during the peri-ovulatory stage. There were 44 follicular growth events, each with two or three follicular waves, and a mean ± SEM interval between events of 17 ± 1.13 days. There were various hemodynamic changes during follicular growth; both vascular resistance index and pulsatility index decreased during the time when the follicle diameter peaked. Thus, both B-mode and Doppler ultrasound were useful for monitoring ovarian follicular events in owl monkeys. © 2013 Elsevier Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study characterized the normal musculoskeletal anatomy of the cervical segment of the spine of dogs by means of B-mode ultrasonography. The objective was to establish the role of B-mode ultrasonography for the anatomical evaluation of the cervical spine segment in dogs, by comparing the ultrasonographic findings with images by computed tomography and magnetic resonance imaging. The ultrasound examination, in transverse and median sagittal sections, allowed to identify a part of the epaxial cervical musculature, the bone surface of the cervical vertebrae and parts of the spinal cord through restricted areas with natural acoustic windows, such as between the atlanto-occipital joint, axis and atlas, and axis and the third cervical vertebra. The images, on transverse and sagittal planes, by low-field magnetic resonance imaging, were superior for the anatomical identification of the structures, due to higher contrast between the different tissues in this modality. Computed tomography showed superiority for bone detailing when compared with ultrasonography. As for magnetic resonance imaging, in addition to the muscles and cervical vertebrae, it is possible to identify the cerebrospinal fluid and differentiate between the nucleus pulposus and annulus fibrosus of the intervertebral discs. Although not the scope of this study, with knowledge of the ultrasonographic anatomy of this region, it is believed that some lesions can be identified, yet in a limited manner, when compared with the information obtained mainly with magnetic resonance imaging. The ultrasound examination presented lower morphology diagnostic value compared with the other modalities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PurposeUltrasonographic evaluation of the eye is a relatively recent addition to routine ophthalmic diagnostics in small animal ophthalmology. Some parameters for ophthalmic biometry have been established. There are few studies in clinical avian ophthalmology that describe ultrasound images of eye in some nocturnal avian species and in other birds that do not belong to the Brazilian fauna, but the psittacine family is not represented. The purpose of this study was to describe the following measurements: the distances between cornea and anterior lens capsule (D1) between the anterior and posterior lens capsule (D2), between posterior lens capsule and optic papilla (D3) and the axial length.MethodSixty four transpalpebral ocular ultrasound examinations were performed on 32 Blue fronted Amazon parrots (Amazona aestiva) with no history of previous ophthalmic disease.Result and DiscussionThe measurements were taken in sagital planes using a 10 MHz linear probe without a standoff pad. The mean values for the left eye were; D1 0.17 +/- 0.03 cm, D2 0.35 +/- 0.02 cm, D3 0.73 +/- 0.04 cm and the axial length 1.26 +/- 0.06 cm. In the right eye D1 0.17 +/- 0.02 cm, D2 0.34 +/- 0.02 cm, D3 0.74 +/- 0.03 cm and the axial length 1.25 +/- 0.05 cm. No significant statistical difference was observed among the birds or between the left and right eye. The description of these parameters will allow the veterinary practitioner to evaluate the structural changes that specific diseases may cause in these animals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sound speed as a diagnostic marker for various diseases of human tissue has been of interest for a while. Up to now, mostly transmission ultrasound computed tomography (UCT) was able to detect spatially resolved sound speed, and its promise as a diagnostic tool has been demonstrated. However, UCT is limited to acoustically transparent samples such as the breast. We present a novel technique where spatially resolved detection of sound speed can be achieved using conventional pulse-echo equipment in reflection mode. For this purpose, pulse-echo images are acquired under various transmit beam directions and a two-dimensional map of the sound speed is reconstructed from the changing phase of local echoes using a direct reconstruction method. Phantom results demonstrate that a high spatial resolution (1 mm) and contrast (0.5 % of average sound speed) can be achieved suitable for diagnostic purposes. In comparison to previous reflection-mode based methods, CUTE works also in a situation with only diffuse echoes, and its direct reconstruction algorithm enables real-time application. This makes it suitable as an addition to conventional clinical ultrasound where it has the potential to benefit diagnosis in a multimodal approach. In addition, knowledge of the spatial distribution of sound speed allows full aberration correction and thus improved spatial resolution and contrast of conventional B-mode ultrasound. © (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Computed ultrasound tomography in echo-mode (CUTE) allows imaging the speed of sound inside tissue using hand-held pulse-echo ultrasound. This technique is based on measuring the changing local phase of beamformed echoes when changing the transmit beam steering angle. Phantom results have shown a spatial resolution and contrast that could qualify CUTE as a promising novel diagnostic modality in combination with B-mode ultrasound. Unfortunately, the large intensity range of several tens of dB that is encountered in clinical images poses difficulties to echo phase tracking and results in severe artefacts. In this paper we propose a modification to the original technique by which more robust echo tracking can be achieved, and we demonstrate in phantom experiments that dynamic range artefacts are largely eliminated. Dynamic range artefact reduction also allowed for the first time a clinical implementation of CUTE with sufficient contrast to reproducibly distinguish the different speed of sound in different tissue layers of the abdominal wall and the neck.