995 resultados para B ultrasound


Relevância:

80.00% 80.00%

Publicador:

Resumo:

AIM: To evaluate the host response of the gel and porous polyethylene implants in anophthalmic cavities using the B scan ultrasound.METHODS: Thirty-six white rabbits underwent unilateral enucleation with placement of gel or porous polyethylene spheres implants. The animals were submitted to clinical examination weekly and to ultrasound evaluation on 30, 60 and 90 days after surgery.RESULTS: All rabbits with gel polyethylene spheres, except one, showed implant extrusion probably because the gel spheres have hydrated and increased in volume. The B ultrasound of the gel polyethylene implant did not show vessels inside during the following period. Five animals (27.8%) with porous polyethylene spheres presented implant extrusion after 30 days of surgery. According to B ultrasound, the porous polyethylene implant showed irregular and heterogeneous architecture and reflective peaks similar to vascularized tissues.CONCLUSION: More studies are required to determine the ideal volume of gel polyethylene implant necessary to correct the diminished orbital content in the anophthalmic cavity. The B ultrasound effectiveness showed in this study for anophthalmic socket implants evaluation provides useful information for further in vivo studies and might substitute expensive methods of implants vascularization evaluation,

Relevância:

60.00% 60.00%

Publicador:

Resumo:

: Los métodos imagenológicos para evaluar los nódulos tiroideos han sido motivo de estudio en las últimas décadas, especialmente la ecografía sobresale sobre las otras modalidades diagnósticas por su accesibilidad, portabilidad, y seguridad. A pesar de ello, las características ecográficas de cada nódulo han sido objeto de controversia en cuanto a su potencial detección de malignidad o benignidad. Se presenta un estudio de concordancia entre el estudio citopatológico y la ecografía para la caracterización nódulos tiroideos de naturaleza maligna y benigna, y su análisis de pruebas diagnósticas. Metodología: Se realizó un estudio descriptivo de concordancia con estudio de pruebas diagnósticas anidado. Se escogieron todos los pacientes con nódulos tiroideos a quienes se les realizó ecografía y estudio citopatológico de la lesión y se estudiaron los hallazgos ecográficos para evaluar su potencial diagnóstico para malignidad. Se incluyeron un total de 100 pacientes con nódulos tiroideos potencialmente malignos. La concordancia entre la ecografía en modo B y el estudio citopatológico fue moderada (índice kappa 0.55). La característica con mayor potencial para detectar malignidad fue la presencia de Microcalcificaciones (sensibilidad 75%, especificidad 92%).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to analyze the thickness of the intima-media complex (IMC) using a noninvasive method. The carotid and femoral common arteries were evaluated by noninvasive B-mode ultrasound in 63 normotensive and in 52 hypertensive subjects and the thickness of the IMC was tested for correlation with blood pressure, cardiac structures and several clinical and biological parameters. The IMC was thicker in hypertensive than in normotensive subjects (0.67 ± 0.13 and 0.62 ± 0.16 vs 0.54 ± 0.09 and 0.52 ± 0.11 mm, respectively, P<0.0001). In normotensive patients, the simple linear regression showed significant correlations between IMC and age, body mass index and 24-h systolic blood pressure for both the carotid and femoral arteries. In hypertensives the carotid IMC was correlated with age and 24-h systolic blood pressure while femoral IMC was correlated only with 24-h diastolic blood pressure. Forward stepwise regression showed that age, body mass index and 24-h systolic blood pressure influenced the carotid IMC relationship (r2 = 0.39) in normotensives. On the other hand, the femoral IMC relationship was influenced by 24-h systolic blood pressure and age (r2 = 0.40). In hypertensives, age and 24-h systolic blood pressure were the most important determinants of carotid IMC (r2 = 0.37), while femoral IMC was influenced only by 24-h diastolic blood pressure (r2 = 0.10). There was an association between carotid IMC and echocardiographic findings in normotensives, while in hypertensives only the left posterior wall and interventricular septum were associated with femoral IMC. We conclude that age and blood pressure influence the intima-media thickness, while echocardiographic changes are associated with the IMC.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

O objetivo deste estudo foi estabelecer o tempo de prenhez da paca por meio de ultra-sonografia. Nove pacas prenhes foram periodicamente acompanhadas com um transdutor eletrônico setorial bi-frequencial de 5,0 e 7,5 MHz, em modo B, desde a detecção ultra-sonográfica da vesícula embrionária ou do feto até o nascimento dos filhotes. Os animais foram colocados em uma gaiola de ferro de prensagem lateral e permaneceram em posição quadrupedal durante as sessões. Um pano escuro foi usado para cobrir a gaiola e frutas foram oferecidas durante o exame ultra-sonográfico para evitar reações agressivas. Quanto mais precocemente ocorreu a detecção de prenhez, maior foi o período de acompanhamento ultra-sonográfico até o nascimento dos filhotes. Apenas um filhote nasceu por parto, com 796,5 ± 74,36 gramas (valor médio ± desvio padrão da amostra) e 33,46 ± 0,60 centímetros (valor médio ± desvio padrão da amostra) de comprimento (entre a borda rostral do focinho e a extremidade distal da cauda). O período de prenhez da paca abrange 135 a 139 dias.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background Gynecological and obstetrical ultrasonography has become an indispensable tool in the routine management, health evaluation and research on captive non-human primates.Methods Ultrasound was used to evaluate the uterus and estimate the gestation of owl monkeys. Twelve couples were selected, where five were primiparous and seven multiparous females from the National Primate Center reproductive colony, Ananindeua-PA, Brazil. The procedures were carried out using the GE (R) Logiq 100 MP, equipped with a 7.5 MHz linear probe.Results the females showed a simple uterus, of elongated shape, regular outline and homogeneous echogenic texture. In the uterine measurements craniocaudal diameter, dorsoventral diameter and uterine volume (UV), significant differences were identified (P < 0.05) between ultrasound examinations of primiparous and multiparous females. The UV showed a positive correlation with the number of births. The gestational sac and the embryonic echo were visible between 28 and 38 days after mating. Between 48 and 68 days after mating, embryonic death was identified in all the gestations.Conclusions the chemical (use of tranquilizers) and husbandry factors (capture stress) may be related to the prenatal death. The establishing methods of conditioning the female to the ultrasonographic exam may offer a solution to this problem.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Ultrasound (B-mode) was used to analyze follicular events in 12 trained female owl monkeys (Aotus azarai infulatus). The animals were examined every 48 hours for over 90days to measure and map follicular growth in both ovaries and to measure (using Doppler velocimetry) local hemodynamic changes during the peri-ovulatory stage. There were 44 follicular growth events, each with two or three follicular waves, and a mean ± SEM interval between events of 17 ± 1.13 days. There were various hemodynamic changes during follicular growth; both vascular resistance index and pulsatility index decreased during the time when the follicle diameter peaked. Thus, both B-mode and Doppler ultrasound were useful for monitoring ovarian follicular events in owl monkeys. © 2013 Elsevier Inc.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Lower gastrointestinal tract neoplasms are rare in domestic animals, representing 3% of all biopsies and necropsies. Our objective is to describe the histopathological and B-mode ultrasound findings in a case of duodenal adenocarcinoma in a dog, since it commonly occurs in the large intestine. On ultrasound examination, there was transmural wall thickening in the duodenum with loss of layer structure, focal peritonitis and adenopathy. Histopathological examination of the intestinal mass revealed a malignant epithelial neoplasm, densely cellular and infiltrative, extending through the lamina propria, submucosa, muscle and hypodermis, characterizing a duodenal adenocarcinoma. We conclude that adenocarcinomas may be included in the differential diagnosis of transmural lesions in the duodenum in B-mode ultrasound examinations, but a laparotomy and biopsy are required for definitive diagnosis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study sought to investigate quantitative and homogeneity differential echogenicity changes of the ABSORB scaffold (1.1) during the first year after implantation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study sought to investigate in vivo the vascular response at the proximal and distal edges of the second-generation ABSORB everolimus-eluting bioresorbable vascular scaffold (BVS).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Extracts from malagueta pepper (Capsicum frutescens L.) were obtained using supercritical fluid extraction (SFE) assisted by ultrasound, with carbon dioxide as solvent at 15MPa and 40°C. The SFE global yield increased up to 77% when ultrasound waves were applied, and the best condition of ultrasound-assisted extraction was ultrasound power of 360W applied during 60min. Four capsaicinoids were identified in the extracts and quantified by high performance liquid chromatography. The use of ultrasonic waves did not influence significantly the capsaicinoid profiles and the phenolic content of the extracts. However, ultrasound has enhanced the SFE rate. A model based on the broken and intact cell concept was adequate to represent the extraction kinetics and estimate the mass transfer coefficients, which were increased with ultrasound. Images obtained by field emission scanning electron microscopy showed that the action of ultrasonic waves did not cause cracks on the cell wall surface. On the other hand, ultrasound promoted disturbances in the vegetable matrix, leading to the release of extractable material on the solid surface. The effects of ultrasound were more significant on SFE from larger solid particles.