933 resultados para Automatic checkout equipment


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thesis (M.S.)--University of Illinois at Urbana-Champaign.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thesis (M.Sc.)--University of Illinois at Urbana-Champaign.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this report a new automated optical test for next generation of photonic integrated circuits (PICs) is provided by the test-bed design and assessment. After a briefly analysis of critical problems of actual optical tests, the main test features are defined: automation and flexibility, relaxed alignment procedure, speed up of entire test and data reliability. After studying varied solutions, the test-bed components are defined to be lens array, photo-detector array, and software controller. Each device is studied and calibrated, the spatial resolution, and reliability against interference at the photo-detector array are studied. The software is programmed in order to manage both PIC input, and photo-detector array output as well as data analysis. The test is validated by analysing state-of-art 16 ports PIC: the waveguide location, current versus power, and time-spatial power distribution are measured as well as the optical continuity of an entire path of PIC. Complexity, alignment tolerance, time of measurement are also discussed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

En este proyecto fin de carrera se ha diseñado y construido un equipo de medida automático que permite realizar la medida de la constante de Planck utilizando los principios de Funcionamiento de los diodos LED. El equipo de medida es totalmente automático gracias a la utilización de una placa controladora Arduino MEGA 2560, que se encarga de realizar la iluminación secuencial de cada LED, medir sus tensiones de funcionamiento, y de realizar los cálculos necesarios para hallar la constante de Planck. Todos los datos se muestran por una pantalla LCD de 16 caracteres por 2 lineas. Para comprender el funcionamiento del sistema de medida automático se ha realizado un estudio detallado de cada uno de los sistemas que componen el equipo de medida. Se ha explicado el funcionamiento teórico de los diodos LED y el funcionamiento de los semiconductores. Se ha explicando los diversos tipos de semiconductores que se utilizan para los LED y las modificaciones que se les aplica para mejorar su eficiencia. Para poder comprender en qué consiste la constante de Planck se ha explicado los principios teóricos en que se basa, y se ha realizado una pequeña demostración de su cálculo. Una vez visto todos los principios teóricos se ha pasado a realizar la explicación de cada uno de los grandes bloques que componen el sistema de medida automático. Estos bloques son la placa controladora Arduino, el sistema de iluminación LED, el sistema de control mecánico de LEDs, la pantalla LCD, el sistema de interrupciones y el sistema de alimentación. Para poder observar el espectro de emisión de cada uno de los LED se ha utilizado un analizador de espectros óptico (OSA), el cual ha sido explicado con detenimiento. El código de programación de Arduino ha sido explicado en forma de diagrama de flujo para una mayor facilidad de comprensión. Se ha desarrollado un manual de usuario para facilitar el uso del sistema a cualquier usuario, en el que se ha introducido un ejemplo completo de funcionamiento. ABSTRACT. In this final Project has designed and built an automatic measuring equipment which is able to measure the Planck`s constant using the operation principles of the LEDs. The measuring equipment is fully automated thanks to the use of an Arduino Mega 2560 controller board, which is responsible for conducting sequential illumination of each LED, measure their operating voltages, and perform the necessary calculations of find the Planck constant. All data is displayed by a LCD screen 16 character by 2 lines. To understand the operation of the automatic measuring system has been made a detailed study of each of the systems that make the measurement equipment. It develops the theoretical performance of the LED and the operation of semiconductors. It explains the different types of semiconductors that are used for LEDs and the changes applied to improve efficiency. In order to understand what is the Planck constant has been explained the theoretical principles in which it is based, and a small demonstration of its calculation has been performed. After seeing all the theoretical principles has been made the explanation of each of the main blocks that compose the automatic measuring system. These blocks are the Arduino controller board, LED lighting system, the mechanical control system LEDs, LCD screen, the interrupt system and feeding system. To observe the emission spectrum of each of the LED has been used optical spectrum analyzer (OSA), which has been explained in detail. The Arduino programming code has been explained in flowchart form for an easy understanding. It has developed a manual to facilitate the use of system to any user, which has introduced a complete example of operation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In cataract surgery, the eye’s natural lens is removed because it has gone opaque and doesn’t allow clear vision any longer. To maintain the eye’s optical power, a new artificial lens must be inserted. Called Intraocular Lens (IOL), it needs to be modelled in order to have the correct refractive power to substitute the natural lens. Calculating the refractive power of this substitution lens requires precise anterior eye chamber measurements. An interferometry equipment, the AC Master from Zeiss Meditec, AG, was in use for half a year to perform these measurements. A Low Coherence Interferometry (LCI) measurement beam is aligned with the eye’s optical axis, for precise measurements of anterior eye chamber distances. The eye follows a fixation target in order to make the visual axis align with the optical axis. Performance problems occurred, however, at this step. Therefore, there was a necessity to develop a new procedure that ensures better alignment between the eye’s visual and optical axes, allowing a more user friendly and versatile procedure, and eventually automatizing the whole process. With this instrument, the alignment between the eye’s optical and visual axes is detected when Purkinje reflections I and III are overlapped, as the eye follows a fixation target. In this project, image analysis is used to detect these Purkinje reflections’ positions, eventually automatically detecting when they overlap. Automatic detection of the third Purkinje reflection of an eye following a fixation target is possible with some restrictions. Each pair of detected third Purkinje reflections is used in automatically calculating an acceptable starting position for the fixation target, required for precise measurements of anterior eye chamber distances.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. A software based tool has been developed (Optem) to allow automatize the recommendations of the Canadian Multiple Sclerosis Working Group for optimizing MS treatment in order to avoid subjective interpretation. METHODS: Treatment Optimization Recommendations (TORs) were applied to our database of patients treated with IFN beta1a IM. Patient data were assessed during year 1 for disease activity, and patients were assigned to 2 groups according to TOR: "change treatment" (CH) and "no change treatment" (NCH). These assessments were then compared to observed clinical outcomes for disease activity over the following years. RESULTS: We have data on 55 patients. The "change treatment" status was assigned to 22 patients, and "no change treatment" to 33 patients. The estimated sensitivity and specificity according to last visit status were 73.9% and 84.4%. During the following years, the Relapse Rate was always higher in the "change treatment" group than in the "no change treatment" group (5 y; CH: 0.7, NCH: 0.07; p < 0.001, 12 m - last visit; CH: 0.536, NCH: 0.34). We obtained the same results with the EDSS (4 y; CH: 3.53, NCH: 2.55, annual progression rate in 12 m - last visit; CH: 0.29, NCH: 0.13). CONCLUSION: Applying TOR at the first year of therapy allowed accurate prediction of continued disease activity in relapses and disability progression.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper addresses a fully automatic landmarks detection method for breast reconstruction aesthetic assessment. The set of landmarks detected are the supraesternal notch (SSN), armpits, nipples, and inframammary fold (IMF). These landmarks are commonly used in order to perform anthropometric measurements for aesthetic assessment. The methodological approach is based on both illumination and morphological analysis. The proposed method has been tested with 21 images. A good overall performance is observed, although several improvements must be achieved in order to refine the detection of nipples and SSNs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To be diagnostically useful, structural MRI must reliably distinguish Alzheimer's disease (AD) from normal aging in individual scans. Recent advances in statistical learning theory have led to the application of support vector machines to MRI for detection of a variety of disease states. The aims of this study were to assess how successfully support vector machines assigned individual diagnoses and to determine whether data-sets combined from multiple scanners and different centres could be used to obtain effective classification of scans. We used linear support vector machines to classify the grey matter segment of T1-weighted MR scans from pathologically proven AD patients and cognitively normal elderly individuals obtained from two centres with different scanning equipment. Because the clinical diagnosis of mild AD is difficult we also tested the ability of support vector machines to differentiate control scans from patients without post-mortem confirmation. Finally we sought to use these methods to differentiate scans between patients suffering from AD from those with frontotemporal lobar degeneration. Up to 96% of pathologically verified AD patients were correctly classified using whole brain images. Data from different centres were successfully combined achieving comparable results from the separate analyses. Importantly, data from one centre could be used to train a support vector machine to accurately differentiate AD and normal ageing scans obtained from another centre with different subjects and different scanner equipment. Patients with mild, clinically probable AD and age/sex matched controls were correctly separated in 89% of cases which is compatible with published diagnosis rates in the best clinical centres. This method correctly assigned 89% of patients with post-mortem confirmed diagnosis of either AD or frontotemporal lobar degeneration to their respective group. Our study leads to three conclusions: Firstly, support vector machines successfully separate patients with AD from healthy aging subjects. Secondly, they perform well in the differential diagnosis of two different forms of dementia. Thirdly, the method is robust and can be generalized across different centres. This suggests an important role for computer based diagnostic image analysis for clinical practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An automatic system was designed to concurrently measure stage and discharge for the purpose of developing stage-discharge ratings and high flow hydrographs on small streams. Stage, or gage height, is recorded by an analog-to-digital recorder and discharge is determined by the constant-rate tracer-dilution method. The system measures flow above a base stage set by the user. To test the effectiveness of the system and its components, eight systems, with a variety of equipment, were installed at crest-stage gaging stations across Iowa. A fluorescent dye, rhodamine-WT, was used as the tracer. Tracer-dilution discharge measurements were made during 14 flow periods at six stations from 1986 through 1988 water years. Ratings were developed at three stations with the aid of these measurements. A loop rating was identified at one station during rapidly-changing flow conditions. Incomplete mixing and dye loss to sediment apparently were problems at some stations. Stage hydrographs were recorded for 38 flows at seven stations. Limited data on background fluorescence during high flows were also obtained.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This report documents work undertaken in the demonstration of a low-cost Automatic Weight and Classification System (AWACS). An AWACS procurement specification and details of the results of the project are also included. The intent of the project is to support and encourage transferring research knowledge to state and local agencies and manufacturers through field demonstrations. Presently available, Weigh-in-Motion and Classification Systems are typically too expensive to permit the wide deployment necessary to obtain representative vehicle data. Piezo electric technology has been used in the United Kingdom and Europe and is believed to be the basic element in a low-cost AWACS. Low-cost systems have been installed at two sites, one in Portland Cement Concrete (PCC) pavement in Iowa and the other in Asphaltic Cement Concrete (ACC) pavement in Minnesota to provide experience with both types of pavement. The systems provide axle weights, gross vehicle weight, axle spacing, vehicle classification, vehicle speed, vehicle count, and time of arrival. In addition, system self-calibration and a method to predict contact tire pressure is included in the system design. The study has shown that in the PCC pavement, the AWACS is capable of meeting the needs of state and federal highway agencies, producing accuracies comparable to many current commercial WIM devices. This is being achieved at a procurement cost of substantially less than currently available equipment. In the ACC pavement the accuracies were less than those observed in the PCC pavement which is concluded to result from a low pavement rigidity at this site. Further work is needed to assess the AWACS performance at a range of sites in ACC pavements.