975 resultados para Automated technical error
Resumo:
The aim of this study was to evaluated the efficacy of the Old Way/New Way methodology (Lyndon, 1989/2000) with regard to the permanent correction of a consolidated and automated technical error experienced by a tennis athlete (who is 18 years old and has been engaged in practice mode for about 6 years) in the execution of serves. Additionally, the study assessed the impact of intervention on the athlete’s psychological skills. An individualized intervention was designed using strategies that aimed to produce a) a detailed analysis of the error using video images; b) an increased kinaesthetic awareness; c) a reactivation of memory error; d) the discrimination and generalization of the correct motor action. The athlete’s psychological skills were measured with a Portuguese version of the Psychological Skills Inventory for Sports (Cruz & Viana, 1993). After the intervention, the technical error was corrected with great efficacy and an increase in the athlete’s psychological skills was verified. This study demonstrates the methodology’s efficacy, which is consistent with the effects of this type of intervention in different contexts.
Resumo:
PURPOSE: To review, retrospectively, the possible causes of sub- or intertrochanteric fractures after screw fixation of intracapsular fractures of the proximal femur. METHODS: Eighty-four patients with an intracapsular fracture of proximal femur were operated between 1995 and 1998 by using three cannulated 6.25 mm screws. The screws were inserted in a triangular configuration, one screw in the upper part of the femoral neck and two screws in the inferior part. Between 1999 and 2001, we use two screws proximally and one screw distally. RESULTS: In the first series, two patients died within one week after operation. Sixty-four fractures healed without problems. Four patients developed an atrophic non-union; avascular necrosis of the femoral head was found in 11 patients. Three patients (3.6%) suffered a sub- and/or intertrochanteric fracture after a mean postoperative time of 30 days, in one case without obvious trauma. In all three cases surgical revision was necessary. Between 1999 and 2001 we did not observe any fracture after screwing. CONCLUSION: Two screws in the inferior part of the femoral neck create a stress riser in the subtrochanteric region, potentially inducing a fracture in the weakened bone. For internal fixation for proximal intracapsular femoral fracture only one screw must be inserted in the inferior part of neck.
Resumo:
O objetivo deste estudo foi comparar os níveis de adiposidade subcutânea dos hemicorpos direito e esquerdo e, posteriormente, analisar o impacto dessas informações para o estudo da composição corporal. Setenta e seis indivíduos fisicamente ativos, 47 homens (21,6 ± 4,3 anos) e 29 mulheres (21,0 ± 2,6 anos), fizeram parte da amostra. As espessuras das dobras cutâneas abdominal, suprailíaca, subescapular, tricipital, bicipital, axilar média e perna medial foram mensuradas com um compasso Lange. Em valores médios absolutos, as maiores diferenças verificadas foram de 0,9mm (6,9%) e 0,8mm (6,8%), na dobra cutânea suprailíaca de homens e mulheres, respectivamente. Entretanto, nenhuma diferença estatisticamente significante foi encontrada na comparação entre os lados, em ambos os sexos, nas sete dobras cutâneas analisadas (P > 0,05). Similarmente, quando os valores medidos foram aplicados em equações preditivas para a determinação da gordura corporal relativa, de acordo com o sexo, nenhuma diferença significante foi encontrada (P > 0,05). Os resultados sugerem que fatores como o erro técnico de medida do avaliador, o tipo de compasso e a escolha da equação preditiva a ser utilizada, provavelmente tenham maior impacto para a estimativa da composição corporal pelo método de espessura de dobras cutâneas do que o lado a ser adotado como referência para a obtenção das medidas.
Resumo:
The objective of this study was to demonstrate the effectiveness of rugoscopy as a human identification method, even when the patient is submitted to rapid palatal expansion, which in theory would introduce doubt. With this intent, the Rugoscopic Identity was obtained for each subject using the classification formula proposed by Santos based on the intra-oral casts made before and after treatment from patients who were subjected to palatal expansion. The casts were labeled with the patients' initials and randomly arranged for studying. The palatine rugae kept the same patterns in every case studied. The technical error of the intra-evaluator measurement provided a confidence interval of 95%, making rugoscopy a reliable identification method for patients who were submitted to rapid palatal expansion, because even in the presence of intra-oral changes owing to the use of palatal expanders, the palatine rugae retained the biological and technical requirements for the human identification process. © 2012 American Academy of Forensic Sciences.
Fragmentos dos trilhos na paisagem de São Paulo: os brownfields ferroviários e sua refuncionalização
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Study Design. Survey of intraobserver and interobserver measurement variability. Objective. To assess the use of reformatted computerized tomography (CT) images for manual measurement of coronal Cobb angles in idiopathic scoliosis. Summary of Background Data. Cobb angle measurements in idiopathic scoliosis are traditionally made from standing radiographs, whereas CT is often used for assessment of vertebral rotation. Correlating Cobb angles from standing radiographs with vertebral rotations from supine CT is problematic because the geometry of the spine changes significantly from standing to supine positions, and 2 different imaging methods are involved. Methods. We assessed the use of reformatted thoracolumbar CT images for Cobb angle measurement. Preoperative CT of 12 patients with idiopathic scoliosis were used to generate reformatted coronal images. Five observers measured coronal Cobb angles on 3 occasions from each of the images. Intraobserver and interobserver variability associated with Cobb measurement from reformatted CT scans was assessed and compared with previous studies of measurement variability using plain radiographs. Results. For major curves, 95% confidence intervals for intraobserver and interobserver variability were +/- 6.6 degrees and +/- 7.7 degrees, respectively. For minor curves, the intervals were +/- 7.5 degrees and +/- 8.2 degrees, respectively. Intraobserver and interobserver technical error of measurement was 2.4 degrees and 2.7 degrees, with reliability coefficients of 88% and 84%, respectively. There was no correlation between measurement variability and curve severity. Conclusions. Reformatted CT images may be used for manual measurement of coronal Cobb angles in idiopathic scoliosis with similar variability to manual measurement of plain radiographs.
Resumo:
Micropapillary serous borderline tumor of the ovary is characterized by a more frequent association with extraovarian, especially invasive, implants. The aim of this study was to report the clinicopathological findings of a rare case of micropapillary serous borderline tumor of the ovary since there are less than 100 similar cases in the published literature. Additionally, the successful management of evisceration that complicated the postoperative stay of the patient is analyzed. The incidence of this severe complication is estimated between 0.29-2.3%. There are four main causes: suture tearing through the fascia, knot failure, suture failure, and extrusion of abdominal contents between sutures placed too far apart. At least 50% of the cases are due to technical error with a potentially lethal result.
Resumo:
The aim of this study was to compare automated ribosomal intergenic spacer analysis (ARISA) and denaturing gradient gel electrophoresis (DGGE) techniques to assess bacterial diversity in the rumen of sheep. Sheep were fed 2 diets with 70% of either alfalfa hay or grass hay, and the solid (SOL) and liquid (LIQ) phases of the rumen were sampled immediately before feeding (0 h) and at 4 and 8 h postfeeding. Both techniques detected similar differences between forages, with alfalfa hay promoting greater (P < 0.05) bacterial diversity than grass hay. In contrast, whereas ARISA analysis showed a decrease (P < 0.05) of bacterial diversity in SOL at 4 h postfeeding compared with 0 and 8 h samplings, no variations (P > 0.05) over the postfeeding period were detected by DGGE. The ARISA technique showed lower (P < 0.05) bacterial diversity in SOL than in LIQ samples at 4 h postfeeding, but no differences (P > 0.05) in bacterial diversity between both rumen phases were detected by DGGE. Under the conditions of this study, the DGGE was not sensitive enough to detect some changes in ruminal bacterial communities, and therefore ARISA was considered more accurate for assessing bacterial diversity of ruminal samples. The results highlight the influence of the fingerprinting technique used to draw conclusions on factors affecting ruminal bacterial diversity.
Resumo:
Title from cover.
Resumo:
Activated sludge models are used extensively in the study of wastewater treatment processes. While various commercial implementations of these models are available, there are many people who need to code models themselves using the simulation packages available to them, Quality assurance of such models is difficult. While benchmarking problems have been developed and are available, the comparison of simulation data with that of commercial models leads only to the detection, not the isolation of errors. To identify the errors in the code is time-consuming. In this paper, we address the problem by developing a systematic and largely automated approach to the isolation of coding errors. There are three steps: firstly, possible errors are classified according to their place in the model structure and a feature matrix is established for each class of errors. Secondly, an observer is designed to generate residuals, such that each class of errors imposes a subspace, spanned by its feature matrix, on the residuals. Finally. localising the residuals in a subspace isolates coding errors. The algorithm proved capable of rapidly and reliably isolating a variety of single and simultaneous errors in a case study using the ASM 1 activated sludge model. In this paper a newly coded model was verified against a known implementation. The method is also applicable to simultaneous verification of any two independent implementations, hence is useful in commercial model development.
Resumo:
The use of bit error models in communication simulation has been widely studied. In this technical report we present three models: the Independent Channel Model; the Gilbert-Elliot Model and the Burst-Error Periodic Model.
Resumo:
In video communication systems, the video signals are typically compressed and sent to the decoder through an error-prone transmission channel that may corrupt the compressed signal, causing the degradation of the final decoded video quality. In this context, it is possible to enhance the error resilience of typical predictive video coding schemes using as inspiration principles and tools from an alternative video coding approach, the so-called Distributed Video Coding (DVC), based on the Distributed Source Coding (DSC) theory. Further improvements in the decoded video quality after error-prone transmission may also be obtained by considering the perceptual relevance of the video content, as distortions occurring in different regions of a picture have a different impact on the user's final experience. In this context, this paper proposes a Perceptually Driven Error Protection (PDEP) video coding solution that enhances the error resilience of a state-of-the-art H.264/AVC predictive video codec using DSC principles and perceptual considerations. To increase the H.264/AVC error resilience performance, the main technical novelties brought by the proposed video coding solution are: (i) design of an improved compressed domain perceptual classification mechanism; (ii) design of an improved transcoding tool for the DSC-based protection mechanism; and (iii) integration of a perceptual classification mechanism in an H.264/AVC compliant codec with a DSC-based error protection mechanism. The performance results obtained show that the proposed PDEP video codec provides a better performing alternative to traditional error protection video coding schemes, notably Forward Error Correction (FEC)-based schemes. (C) 2013 Elsevier B.V. All rights reserved.
Resumo:
A dissertação em apreço resultou da necessidade em otimizar os recursos técnicos, mas sobretudo humanos, afetos às verificações de instrumentos de medição, no âmbito do Controlo Metrológico Legal. Estas verificações, realizadas nos termos do cumprimento das competências outrora atribuídas à Direção de Serviços da Qualidade da então Direção Regional da Economia do Norte, eram operacionalizadas pela Divisão da Qualidade e Licenciamento, na altura dirigida pelo subscritor da presente tese, nomeadamente no que respeita aos ensaios efetuados, em laboratório, a manómetros analógicos. O objetivo principal do trabalho foi alcançado mediante o desenvolvimento de um automatismo, materializado pela construção de um protótipo, cuja aplicação ao comparador de pressão múltiplo, dantes em utilização, permitiria realizar a leitura da indicação de cada manómetro analógico através de técnicas de processamento de imagem, função esta tradicionalmente efetuada manualmente por um operador especializado. As metodologias de comando, controlo e medição desse automatismo foram realizadas através de um algoritmo implementado no software LabVIEW® da National Intruments, particularmente no que respeita ao referido processamento das imagens adquiridas por uma câmara de vídeo USB. A interface com o hardware foi concretizada recorrendo a um módulo de Aquisição de Dados Multifuncional (DAQ) USB-6212, do mesmo fabricante. Para o posicionamento horizontal e vertical da câmara de vídeo USB, recorreu-se a guias lineares acionadas por motores de passo, sendo que estes dispositivos foram igualmente empregues no acionamento do comparador de pressão. Por último, procedeu-se à aquisição digital da leitura do padrão, recorrendo à respetiva virtualização, bem como a uma aplicação desenvolvida neste projeto, designada appMAN, destinada à gestão global do referido automatismo, nomeadamente no que se refere ao cálculo do resultado da medição, erro e incerteza associada, e emissão dos respetivos documentos comprovativos.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica
Resumo:
Among the largest resources for biological sequence data is the large amount of expressed sequence tags (ESTs) available in public and proprietary databases. ESTs provide information on transcripts but for technical reasons they often contain sequencing errors. Therefore, when analyzing EST sequences computationally, such errors must be taken into account. Earlier attempts to model error prone coding regions have shown good performance in detecting and predicting these while correcting sequencing errors using codon usage frequencies. In the research presented here, we improve the detection of translation start and stop sites by integrating a more complex mRNA model with codon usage bias based error correction into one hidden Markov model (HMM), thus generalizing this error correction approach to more complex HMMs. We show that our method maintains the performance in detecting coding sequences.