982 resultados para Australian commercial building


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper evaluates and compares the system performance of a solar desiccant-evaporative cooling (SDEC) system with a referenced conventional variable air volume (VAV) system for a typical office building in all 8 Australian capital cities. A simulation model of the building is developed using the whole building simulation software EnergyPlus. The performance indicators for the comparison are system coefficient of performance (COP), annual primary energy consumption, annual energy savings, and annual CO2 emissions reduction. The simulation results show that Darwin has the most apparent advantages for SDEC system applications with an annual energy savings of 557 GJ and CO2 emission reduction of 121 tonnes. The maximum system COP is 7. For other climate zones such as Canberra, Hobart and Melbourne, the SDEC system is not as energy efficient as the conventional VAV system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Renovation and refurbishment of the existing commercial building stock is a growing area of total construction activity and a significant generator of waste sent to landfill in Australia. A written waste management plan (WMP) is a widespread regulatory requirement for commercial office redevelopment projects. There is little evidence, however, that WMPs actually increase the quantity of waste that is ultimately diverted from landfill. Some reports indicate an absence of any formal verification or monitoring process by regulators to assess the efficacy of the plans. In order to gauge the extent of the problem a survey was conducted of twenty four consultants and practitioners involved in commercial office building refurbishment projects to determine the state of current practice with regard to WMPs and to elicit suggestions with regard to ways of making the process more effective. Considerable variation in commitment to recycling policies was encountered indicating a need to revisit waste minimisation practices if the environmental performance of refurbishment projects is to be improved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effective daylighting of multistorey commercial building interiors poses an interesting problem for designers in Australia’s tropical and subtropical context. Given that a building exterior receives adequate sun and skylight as dictated by location-specific factors such as weather, siting and external obstructions; then the availability of daylight throughout its interior is dependant on certain building characteristics: the distance from a window façade (room depth), ceiling or window head height, window size and the visible transmittance of daylighting apertures. The daylighting of general stock, multistorey commercial buildings is made difficult by their design limitations with respect to some of these characteristics. The admission of daylight to these interiors is usually exclusively by vertical windows. Using conventional glazing, such windows can only admit sun and skylight to a depth of approximately 2 times the window height. This penetration depth is typically much less than the depth of the office interiors, so that core areas of these buildings receive little or no daylight. This issue is particularly relevant where deep, open plan office layouts prevail. The resulting interior daylight pattern is a relatively narrow perimeter zone bathed in (sometimes too intense) light, contrasted with a poorly daylit core zone. The broad luminance range this may present to a building occupant’s visual field can be a source of discomfort glare. Furthermore, the need in most tropical and subtropical regions to restrict solar heat gains to building interiors for much of the year has resulted in the widespread use of heavily tinted or reflective glazing on commercial building façades. This strategy reduces the amount of solar radiation admitted to the interior, thereby decreasing daylight levels proportionately throughout. However this technique does little to improve the way light is distributed throughout the office space. Where clear skies dominate weather conditions, at different times of day or year direct sunlight may pass unobstructed through vertical windows causing disability or discomfort glare for building occupants and as such, its admission to an interior must be appropriately controlled. Any daylighting system to be applied to multistorey commercial buildings must consider these design obstacles, and attempt to improve the distribution of daylight throughout these deep, sidelit office spaces without causing glare conditions. The research described in this thesis delineates first the design optimisation and then the actual prototyping and manufacture process of a daylighting device to be applied to such multistorey buildings in tropical and subtropical environments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper investigates energy saving potential of commercial building by living wall and green façade system using Envelope Thermal Transfer Value (ETTV) equation in Sub-tropical climate of Australia. Energy saving of four commercial buildings was quantified by applying living wall and green façade system to the west facing wall. A field experimental facility, from which temperature data of living wall system was collected, was used to quantify wall temperatures and heat gain under controlled conditions. The experimental parameters were accumulated with extensive data of existing commercial building to quantify energy saving. Based on temperature data of living wall system comprised of Australian native plants, equivalent temperature of living wall system has been computed. Then, shading coefficient of plants in green façade system has been included in mathematical equation and in graphical analysis. To minimize the air-conditioned load of commercial building, therefore to minimize the heat gain of commercial building, an analysis of building heat gain reduction by living wall and green façade system has been performed. Overall, cooling energy performance of commercial building before and after living wall and green façade system application has been examined. The quantified energy saving showed that only living wall system on opaque part of west facing wall can save 8-13 % of cooling energy consumption where as only green façade system on opaque part of west facing wall can save 9.5-18% cooling energy consumption of commercial building. Again, green façade system on fenestration system on west facing wall can save 28-35 % of cooling energy consumption where as combination of both living wall on opaque part of west facing wall and green façade on fenestration system on west facing wall can save 35-40% cooling energy consumption of commercial building in sub-tropical climate of Australia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Growing global concern regarding the rapid rate at which humans are consuming the earth’s precious natural resources is leading to greater emphasis on more effective means of providing for our current and future needs. Energy and fresh water are the most crucial of these basic human needs. The energy and water required in the operation of buildings is fairly well known. Much less is known about the energy and water embodied in construction materials and products. It has been suggested that embodied energy typically represents 20 times the annual operational energy of current Australian buildings. Studies have suggested that the water embodied in buildings may be just as significant as that of energy. As for embodied energy, these studies have been based on traditional analysis methods, such as process and input-output analysis. These methods have been shown to suffer from errors relating to the availability of data and its reliability. Hybrid methods have been developed in an attempt to provide a more reliable assessment of the embodied energy and water associated with the construction of buildings. This paper evaluates the energy and water resources embodied in a commercial office building using a hybrid analysis method based on input-output data. It was found that the use of this hybrid analysis method increases the reliability and completeness of an embodied energy and water analysis of a typical commercial building by 45% and 64% respectively, over traditional analysis methods. The embodied energy and water associated with building construction is significant and thus represents an area where considerable energy and water savings are possible over the building life-cycle. These findings suggest that current best-practice methods of embodied energy and water analysis are sufficiently accurate for most typical applications, but this is heavily dependent upon data quality and availability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The operation of two 60 m2 solar air heaters serving a large studio teaching space has been monitored for a twelve month period. The solar contribution of the heaters was found to be less than 5%, and in some instances the heaters actually contributed to the space heating load. A validated mathematical model of the studio and it’s heating, ventilation and air conditioning system was used to investigate performance improvement strategies. It was found a different control strategy and recommissioned control sensors would substantially improve the solar air heater performance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper investigates cooling energy performance of commercial building before and after green roof and living wall application based on integrated building heat gain model developed from Overall Thermal Transfer Value (OTTV) of building wall and steady state heat transfer process of roof in sub-tropical climate. Using the modelled equation and eQUEST energy simulation tool, commercial building envelope parameters and relevant heat gain parameters have been accumulated to analyse the heat gain and cooling energy consumption of commercial building. Real life commercial building envelope and air-conditioned load data for the sub-tropical climate zone have been collected and compared with the modelled analysis. Relevant temperature data required for living wall and green roof analysis have been collected from experimental setup comprised of both green roof and west facing living wall. Then, Commercial building heat flux and cooling energy performance before and after green roof and living wall application have been scrutinized.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Australian Commercial Law offers a concise yet comprehensive introduction to commercial law in Australia. The textbook provides a thorough and detailed discussion of a variety of topics in commercial law such as agency, bailment, the sale of goods, the transfer of property and the Personal Property Securities Act. The book also offers a detailed overview of topics within the Australian Consumer Law that are now relevant to commercial practice such as unconscionable conduct, consumer guarantees, and misleading and deceptive conduct. Written in a clear and accessible style, each chapter features key points and further reading to enhance students' understanding. Significant cases are discussed in detail and include excerpts from judgments to illustrate points of law. Australian Commercial Law is an indispensable resource for students who are seeking a comprehensive understanding of commercial law.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This greenhouse study investigated the efficacy of acibenzolar-S-methyl (Bion®) treatment of lower leaves of passionfruit, (Passiflora edulis f. sp. flavicarpa), on Passionfruit woodiness disease and activities of two pathogenesis-related proteins, chitinase and β-1,3-glucanase after inoculation with passionfruit woodiness virus (PWV). All Bion® concentrations reduced disease symptoms, but the concentration of 0.025 g active ingredient (a.i.)/l was the most effective, reducing disease severity in systemic leaves by 23, 29 and 30 compared with water-treated controls at 30, 40 and 50 days post inoculation (dpi) with PWV, respectively. Correspondingly, relative virus concentration as determined by DAS-ELISA in the upper, untreated leaves (new growth) above the site of inoculation at 50 dpi was reduced by 17 and 22 in plants treated with 0.025 and 0.05 g a.i./l, respectively. Bion® treatment and subsequent inoculation with PWV increased chitinase and β-1,3-glucanase activities in the new leaves above the site of inoculation at 30 dpi with PWV. It was concluded that optimal protective Bion® treatment concentrations were 0.025 and 0.05 g a.i./l.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We estimate a carbon mitigation cost curve for the U.S. commercial sector based on econometric estimation of the responsiveness of fuel demand and equipment choices to energy price changes. The model econometrically estimates fuel demand conditional on fuel choice, which is characterized by a multinomial logit model. Separate estimation of end uses (e.g., heating, cooking) using the U.S. Commercial Buildings Energy Consumption Survey allows for exceptionally detailed estimation of price responsiveness disaggregated by end use and fuel type. We then construct aggregate long-run elasticities, by fuel type, through a series of simulations; own-price elasticities range from -0.9 for district heat services to -2.9 for fuel oil. The simulations form the basis of a marginal cost curve for carbon mitigation, which suggests that a price of $20 per ton of carbon would result in an 8% reduction in commercial carbon emissions, and a price of $100 per ton would result in a 28% reduction. © 2008 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper uses long-term regional construction data to investigate whether increases infrastructure investment in the English regions leads to subsequent rises in housebuilding and new commercial property, using time series modeling. Both physical (roads and harbours) and social infrastructure (education and health) impacts are investigated across nine regions in England. Significant effects for physical infrastructure are found across most regions and, also, some evidence of a social infrastructure effect. The results are not consistent across regions, which may be due to geographical differences and to network and diversionary effects. However, the results do suggest that infrastructure does have some impact but follows differential lag structures. These results provide a test of the hypothesis of the economic benefits of infrastructure investment in an approach that has not been used before.