94 resultados para Auscultation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Oropharyngeal aspiration (OPA) can lead to recurrent respiratory illnesses and chronic lung disease in children. Current clinical feeding evaluations performed by speech pathologists have poor reliability in detecting OPA when compared to radiological procedures such as the modified barium swallow (MBS). Improved ability to diagnose OPA accurately via clinical evaluation potentially reduces reliance on expensive, less readily available radiological procedures. Our study investigates the utility of adding cervical auscultation (CA), a technique of listening to swallowing sounds, in improving the diagnostic accuracy of a clinical evaluation for the detection of OPA. Methods We plan an open, unblinded, randomised controlled trial at a paediatric tertiary teaching hospital. Two hundred and sixteen children fulfilling the inclusion criteria will be randomised to one of the two clinical assessment techniques for the clinical detection of OPA: (1) clinical feeding evaluation only (CFE) group or (2) clinical feeding evaluation with cervical auscultation (CFE + CA) group. All children will then undergo an MBS to determine radiologically assessed OPA. The primary outcome is the presence or absence of OPA, as determined on MBS using the Penetration-Aspiration Scale. Our main objective is to determine the sensitivity, specificity, negative and positive predictive values of ‘CFE + CA’ versus ‘CFE’ only compared to MBS-identified OPA. Discussion Early detection and appropriate management of OPA is important to prevent chronic pulmonary disease and poor growth in children. As the reliability of CFE to detect OPA is low, a technique that can improve the diagnostic accuracy of the CFE will help minimise consequences to the paediatric respiratory system. Cervical auscultation is a technique that has previously been documented as a clinical adjunct to the CFE; however, no published RCTs addressing the reliability of this technique in children exist. Our study will be the first to establish the utility of CA in assessing and diagnosing OPA risk in young children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article considers national policy drivers promoting the development of advanced assessment skills and practical procedures for the safe and effective use of the stethoscope in the clinical area. The evidence base underpinning effective use of the stethoscope in clinical practice is explored, including the preparation of the patient and the environment, applying infection control policies, and placing an emphasis on privacy and dignity. This is followed by a practical guide to auscultation technique of the respiratory system for nurses developing advanced practice skills.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article outlines the correct procedure for respiratory assessments using a stethoscope, how to use a stethoscope and how to interpret your findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Acute respiratory infections are usual in children under three years old occurring in upper respiratory tract, having an impact on child and caregiver’s quality of life predisposing to otitis media or bronchiolitis. There are few valid and reliable measures to determine the child’s respiratory condition and to guide the physiotherapy intervention. Aim: To assess the intra and inter rater reliability of nasal auscultation, to analyze the relation between sounds’ classification and middle ear’s pressure and compliance as well as with the Clinical Severity Score. Methods: A cross-sectional observational study was composed by 125 nursery children aged up to three years old. Tympanometry, pulmonary and nasal auscultation and application of Clinical Severity Score were performed to each child. Nasal auscultation sounds’ were recorded and sent to 3 blinded experts, that classified, as “obstructed” and “unobstructed”, with a 48 hours interval, in order to analyze inter and intra rater reliability. Results: Nasal auscultation revealed a substantial inter and intra rater reliability (=0,749 and evaluator A - K= 0,691; evaluator B - K= 0,605 and evaluator C - K= 0,724, respectively). Both ears’ pressure was significantly lower in children with an "unobstructed" nasal sound when compared with an “obstructed” nasal sound (t=-3,599, p<0,001 in left ear; t=-2,258, p=0,026 in right ear). Compliance in both ears was significantly lower in children with an "obstructed" nasal sound when compared with “unobstructed” nasal sound (t=-2,728, p=0,007 in left ear; t=-3,830, p<0,001 in right ear). There was a statistically significant association between sounds’ classification and tympanograms types in both ear’s (=11,437, p=0,003 in left ear; =13,535, p=0,001 in right ear). There was a trend to children with an "unobstructed" nasal sound that had a lower clinical severity score when compared with “obstructed” children. Conclusion: It was observed a good intra and substantial inter reliability for nasal auscultation. Nasal auscultation sounds’ classification was related to middle ears’ pressure and compliance.