998 resultados para Artificial urine


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This tunable holographic sensor offers interrogation and a reporting transducer as well as an analyte-responsive hydrogel, rendering it label-free and reusable. A single 6 ns laser pulse is used to fabricate holographic sensors consisting of silver nanoparticles arranged periodically within a polymer film. The tunability of the sensor is demonstrated through pH sensing of artificial urine and validated through computational modeling. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study presents a reproducible, cost-effective in vitro encrustation model and, furthermore, describes the effects of components of the artificial urine and the presence of agents that modify the action of urease on encrustation on commercially available ureteral stents. The encrustation model involved the use of small-volume reactors (700 mL) containing artificial urine and employing an orbital incubator (at 37 degrees C) to ensure controlled stirring. The artificial urine contained sources of calcium and magnesium (both as chlorides), albumin and urease. Alteration of the ratio (% w/w) of calcium salt to magnesium salt affected the mass of encrustation, with the greatest encrustation noted whenever magnesium was excluded from the artificial urine. Increasing the concentration of albumin, designed to mimic the presence of protein in urine, significantly decreased the mass of both calcium and magnesium encrustation until a plateau was observed. Finally, exclusion of urease from the artificial urine significantly reduced encrustation due to the indirect effects of this enzyme on pH. Inclusion of the urease inhibitor, acetohydroxamic acid, or urease substrates (methylurea or ethylurea) into the artificial medium markedly reduced encrustation on ureteral stents. In conclusion, this study has described the design of a reproducible, cost-effective in vitro encrustation model. Encrustation was markedly reduced on biomaterials by the inclusion of agents that modify the action of urease. These agents may, therefore, offer a novel clinical approach to the control of encrustation on urological medical devices. (c) 2005 Wiley Periodicals, Inc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This article describes a prototype system for quantifying bioassays and for exchanging the results of the assays digitally with physicians located off-site. The system uses paper-based microfluidic devices for running multiple assays simultaneously, camera phones or portable scanners for digitizing the intensity of color associated with each colorimetric assay, and established communications infrastructure for transferring the digital information from the assay site to an off-site laboratory for analysis by a trained medical professional; the diagnosis then can be returned directly to the healthcare provider in the field. The microfluidic devices were fabricated in paper using photolithography and were functionalized with reagents for colorimetric assays. The results of the assays were quantified by comparing the intensities of the color developed in each assay with those of calibration curves. An example of this system quantified clinically relevant concentrations of glucose and protein in artificial urine. The combination of patterned paper, a portable method for obtaining digital images, and a method for exchanging results of the assays with off-site diagnosticians offers new opportunities for inexpensive monitoring of health, especially in situations that require physicians to travel to patients (e.g., in the developing world, in emergency management, and during field operations by the military) to obtain diagnostic information that might be obtained more effectively by less valuable personnel.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The indwelling urethral catheter has an important role for patients with urinary retention, bladder obstruction, neurological damage and other diseases. Urine contains minerals which precipitate in alkaline pH, crystallize and block the urological catheter. The crystallization of the ionic components of urine occurs in the presence of urease, an enzyme produced by Proteus mirabilis. This bacterium adheres to inanimate surfaces and forms biofilms. The aim of this study was to investigate the formation of crystalline biofilm on the luminal surface of siliconized latex catheters by means of scanning electron microscope, after channeling artificial urine infected with Proteus mirabilis. The experiment was performed in vitro using a dynamic flow system. The artificial urine compounds were salts of calcium, magnesium, phosphates, urea and egg albumin, and it was infected with Proteus mirabilis ATCC 25933. The urine flow was stopped after crystallization of the ionic components. Crystallization was observed after alkalinization of urine. Scanning electron microscopy showed the presence of crystals and morphologies typical of bacilli embedded in an amorphous mass on the internal lumen of the catheter. The present study showed that catheter encrustation may limit the use of long-term indwelling catheter. © SBEB - Sociedade Brasileira de Engenharia Biomédica.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A series of linear peptide based anion receptors, in which the distance between the bis[zinc(II)dipicolylamine] binding sites and the peptide backbone was varied systematically, was prepared and their anion binding ability was investigated using indicator displacement assays. Shortening the distance between the binding site and the peptide backbone was found to enhance both the receptor affinity and selectivity for pyrophosphate over other organic polyphosphate anions in Krebs buffer with the maximum selectivity and affinity observed with a spacer length of two methylene units. The suitability of these receptors for the determination of pyrophosphate concentrations in Krebs buffer and in artificial urine was examined.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nucleosides in human urine and serum have frequently been studied as a possible biomedical marker for cancer, acquired immune deficiency syndrome (AIDS) and the whole-body turnover of RNAs. Fifteen normal and modified nucleosides were determined in 69 urine and 42 serum samples using high-performance liquid chromatography (HPLC). Artificial neural networks have been used as a powerful pattern recognition tool to distinguish cancer patients from healthy persons. The recognition rate for the training set reached 100%. In the validating set, 95.8 and 92.9% of people were correctly classified into cancer patients and healthy persons when urine and serum were used as the sample for measuring the nucleosides. The results show that the artificial neural network technique is better than principal component analysis for the classification of healthy persons and cancer patients based on nucleoside data. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A series of imprinted polymers targeting nucleoside metabolites, prepared using a template analogue approach, are presented. These were prepared following selection of the optimum functional monomer by solution association studies using 1H-NMR titrations whereby methacrylic acid was shown to be the strongest receptor with and affinity constant of 621 ± 51 L mol-1 vs. 110 ± 16 L mol-1 for acrylamide. The best performing polymers were prepared using methanol as porogenic co-solvent and although average binding site affinities were marginally reduced, 2.3×104 L mol-1 vs. 2.7×104 L mol-1 measured for a polymer prepared in acetonitrile, these polymers contained the highest number of binding sites, 5.27 μmol g-1¬¬ vs. 1.64 μmol g-1, while they also exhibited enhanced selectivity for methylated guanosine derivatives. When applied as sorbents in the extraction of nucleoside derivative cancer biomarkers from synthetic urine samples, significant sample clean-up and recoveries of up to 90% for 7-methylguanosine were achieved.