892 resultados para Artificial respiration.


Relevância:

100.00% 100.00%

Publicador:

Resumo:

"Translation of an article ... in the Russian-language journal vestnik khirurgii (Herald of surgery), vol. 90, no. 3, March 1963, pages 81-87."

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: Pneumothorax is a frequent complication during mechanical ventilation. Electrical impedance tomography (EIT) is a noninvasive tool that allows real-time imaging of regional ventilation. The purpose of this study was to 1) identify characteristic changes in the EIT signals associated with pneumothoraces; 2) develop and fine-tune an algorithm for their automatic detection; and 3) prospectively evaluate this algorithm for its sensitivity and specificity in detecting pneumothoraces in real time. Design: Prospective controlled laboratory animal investigation. Setting: Experimental Pulmonology Laboratory of the University of Sao Paulo. Subjects: Thirty-nine anesthetized mechanically ventilated supine pigs (31.0 +/- 3.2 kg, mean +/- SD). Interventions. In a first group of 18 animals monitored by EIT, we either injected progressive amounts of air (from 20 to 500 mL) through chest tubes or applied large positive end-expiratory pressure (PEEP) increments to simulate extreme lung overdistension. This first data set was used to calibrate an EIT-based pneumothorax detection algorithm. Subsequently, we evaluated the real-time performance of the detection algorithm in 21 additional animals (with normal or preinjured lungs), submitted to multiple ventilatory interventions or traumatic punctures of the lung. Measurements and Main Results: Primary EIT relative images were acquired online (50 images/sec) and processed according to a few imaging-analysis routines running automatically and in parallel. Pneumothoraces as small as 20 mL could be detected with a sensitivity of 100% and specificity 95% and could be easily distinguished from parenchymal overdistension induced by PEEP or recruiting maneuvers, Their location was correctly identified in all cases, with a total delay of only three respiratory cycles. Conclusions. We created an EIT-based algorithm capable of detecting early signs of pneumothoraces in high-risk situations, which also identifies its location. It requires that the pneumothorax occurs or enlarges at least minimally during the monitoring period. Such detection was operator-free and in quasi real-time, opening opportunities for improving patient safety during mechanical ventilation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Antivenom in order to be effective in the treatment of coral snake accidents must be injected very soon after the bite owing to the rapid rate of absorption of the venom neurotoxins. As this is not always possible, other forms of treatment besides serotherapy must be employed to avoid asphyxia and death. Neostigmine and artificial respiration are used for this purpose. Neostigmine restores neuromuscular transmission if the venom-induced blockade results from a reversible interaction of its neurotoxins with the end-plate receptors. This is the mechanism of the neuromuscular blockade produced by the venom of M. frontalis snakes from centereastern and southern Brazil, and Argentine. Neostigmine is able, therefore, to antagonize the blockade, and has been shown to be very effective in the treatment of the experimental envenomation of dogs and monkeys. In the present communication, two cases of M. frontalis accidents treated with antivenom and neostigmine are reported. In both, neostigmine was successful in producing regression of the paralysis, confirming the effectiveness shown in the treatment of the poisoning induced in animals by M. frontalis venom.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The health status of previously premature neonates after closure of a patent ductus arteriosus (PDA) was analyzed in childhood and adolescence. Physician questionnaires were used to study 180 hospital survivors among 210 consecutive premature neonates who underwent PDA closure between 1985 and 2005. Complete follow-up data were obtained for 129 patients (72%). During a median follow-up period of 7 years (range, 2-22 years), three late deaths (2.3%) had occurred. Only 45% of the patients were considered healthy. Morbidity included developmental delay (41.1%), pulmonary illness (12.4%), neurologic impairment (14.7%), hearing impairment (3.9%), gastrointestinal disease (3.1%), and thoracic deformity (1.2%). None of the adverse variables during the neonatal period (intraventricular hemorrhage, bradycardia apnea syndrome, bronchopulmonary dysplasia, pulmonary bleeding, hyaline membrane disease, artificial respiration time [continuous positive airway pressure + intubation], or necrotizing enterocolitis) statistically predicted respective system morbidity at the follow-up evaluation. Hyaline membrane disease (odds ratio, 2.5; p = 0.026) and longer hospitalization time (odds ratio, 1.2 days per 10 hospitalization days; p = 0.032) in the newborn period were significant predictors of an unhealthy outcome at the last follow-up evaluation. Survival until childhood after closure of a hemodynamically significant PDA in premature neonates is satisfactory. However, physical and neurodevelopmental co-morbidity persist for half of the patients, perhaps as a sequela of prematurity unrelated to ductus closure.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The forced oscillation technique (FOT) is a method for non-invasively assessing respiratory mechanics that is applicable both in paralysed and non-paralysed patients. As the FOT requires a minimal modification of the conventional ventilation setting and does not interfere with the ventilation protocol, the technique is potentially useful to monitor patient mechanics during invasive and noninvasive ventilation. FOT allows the assessment of the respiratory system linearity by measuring resistance and reactance at different lung volumes or end-expiratory pressures. Moreover, FOT allows the physician to track the changes in patient mechanics along the ventilation cycle. Applying FOT at different frequencies may allow the physician to interpret patient mechanics in terms of models with pathophysiological interest. The current methodological and technical experience make possible the implementation of portable and compact computerised FOT systems specifically addressed to its application in the mechanical ventilation setting.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Quality control procedures vary considerably among the providers of equipment for home mechanical ventilation (HMV). Methods: A multicentre quality control survey of HMV was performed at the home of 300 patients included in the HMV programmes of four hospitals in Barcelona. It consisted of three steps: (1) the prescribed ventilation settings, the actual settings in the ventilator control panel, and the actual performance of the ventilator measured at home were compared; (2) the different ventilator alarms were tested; and (3) the effect of differences between the prescribed settings and the actual performance of the ventilator on non-programmed readmissions of the patient was determined. Results: Considerable differences were found between actual, set, and prescribed values of ventilator variables; these differences were similar in volume and pressure preset ventilators. The percentage of patients with a discrepancy between the prescribed and actual measured main ventilator variable (minute ventilation or inspiratory pressure) of more than 20% and 30% was 13% and 4%, respectively. The number of ventilators with built in alarms for power off, disconnection, or obstruction was 225, 280 and 157, respectively. These alarms did not work in two (0.9%), 52 (18.6%) and eight (5.1%) ventilators, respectively. The number of non-programmed hospital readmissions in the year before the study did not correlate with the index of ventilator error. Conclusions: This study illustrates the current limitations of the quality control of HMV and suggests that improvements should be made to ensure adequate ventilator settings and correct ventilator performance and ventilator alarm operation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aquest estudi emmarcat dins un treball de final del Màster en Promoció de la Salut m’ha servit per veure que encara hi ha un llarg recorregut a investigar en el camp de la reanimació cardiopulmonar. Les 3 línees sorgides son: com millorar la qualitat en RCP, buscar estratègies per augmentar les freqüències mitges de compressió toràcica externa i com ensenyar a retenir les tècniques de RCP Penso que totes elles s’aniran desenvolupant en els propers anys i que aquelles accions que vagin encaminades a millorar la supervivència de la principal causa de mort dels europeus en edat compreses entre els 35 i 36 anys hauria de ser una tasca prioritària en investigació

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Mechanical ventilation has been associated with organ failure in patients with acute respiratory distress syndrome. The present study examines the effects of tidal volume (V T) on renal function using two V T values (8 and 27 mL/kg) in anesthetized, paralyzed and mechanically ventilated male Wistar rats. Animals were randomized into two groups of 6 rats each: V T8 (V T, 8 mL/kg; 61.50 ± 0.92 breaths/min; positive end-expiratory pressure, 3.0 cmH2O; peak airway pressure (PAW), 11.8 ± 2.0 cmH2O), and V T27 (V T, 27 mL/kg; 33.60 ± 1.56 breaths/min; positive end-expiratory pressure, none, and PAW, 22.7 ± 4.0 cmH2O). Throughout the experiment, mean PAW remained comparable between the two groups (6.33 ± 0.21 vs 6.50 ± 0.22 cmH2O). For rats in the V T27 group, inulin clearance (mL·min-1·body weight-1) decreased acutely after 60 min of mechanical ventilation and even more significantly after 90 min, compared with baseline values (0.60 ± 0.05 and 0.45 ± 0.05 vs 0.95 ± 0.07; P < 0.001), although there were no differences between groups in mean arterial pressure or gasometric variables. In the V T8 group, inulin clearance at 120 min of mechanical ventilation remained unchanged in relation to baseline values (0.72 ± 0.03 vs 0.80 ± 0.05). The V T8 and V T27 groups did not differ in terms of serum thiobarbituric acid reactive substances (3.97 ± 0.27 vs 4.02 ± 0.45 nmol/mL) or endothelial nitric oxide synthase expression (94.25 ± 2.75 vs 96.25 ± 2.39%). Our results show that glomerular filtration is acutely affected by high tidal volume ventilation but do not provide information about the mechanism.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aquest estudi emmarcat dins un treball de final del Màster en Promoció de la Salut m’ha servit per veure que encara hi ha un llarg recorregut a investigar en el camp de la reanimació cardiopulmonar. Les 3 línees sorgides son: com millorar la qualitat en RCP, buscar estratègies per augmentar les freqüències mitges de compressió toràcica externa i com ensenyar a retenir les tècniques de RCP Penso que totes elles s’aniran desenvolupant en els propers anys i que aquelles accions que vagin encaminades a millorar la supervivència de la principal causa de mort dels europeus en edat compreses entre els 35 i 36 anys hauria de ser una tasca prioritària en investigació

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Este estudo objetivou atualizar os conhecimentos em relação à utilização da ventilação mecânica não-invasiva (VMNI) no pós-operatório de cirurgia cardíaca e identificar se há indícios da superioridade de uma forma de modalidade de VMNI em relação à outra. Foi realizada revisão da literatura entre 2006 a 2011, a partir das bases de dados PubMed, SciELO e Lilacs, utilizando os descritores respiração artificial, pressão positiva contínua nas vias aéreas, ventilação com pressão positiva intermitente e cirurgia cardíaca, e seus correspondentes na língua inglesa, os quais foram pesquisados em cruzamentos. A partir dos critérios adotados, foram selecionados nove artigos, dos quais seis demonstraram aplicações de VMNI, por meio de modalidades como pressão positiva contínua nas vias aéreas, pressão positiva com dois níveis pressóricos e respiração com pressão positiva intermitente, no pós-operatório de cirurgia cardíaca, e, três realizaram comparações entre as diferentes modalidades. As modalidades de VMNI descritas na literatura foram utilizadas com resultados satisfatórios. Estudos que comparam diferentes modalidades são escassos, contudo alguns demonstraram superioridade de uma modalidade de VMNI, como é o caso da respiração com pressão positiva intermitente na reversão da hipoxemia e da pressão positiva com dois níveis pressóricos na melhora da oxigenação, da frequência respiratória e frequência cardíaca desses pacientes, em comparação a outras modalidades.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)