977 resultados para Arthroscopic hip surgery


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Placing portal incisions during arthroscopic hip surgery presents challenges for surgeons in terms of anatomic accessibility and patient safety. Based on key anatomic landmarks and portal placement information from recent literature, suggested portal incisions were determined. Guidance in the placement of the three most common portal incision locations (anterior, anterolateral, and posterolateral) for arthroscopic surgery; in addition to visual feedback on tool trajectory to the hip joint is provided in real time by a computer aided system for hip arthroscopy. By simplifying the portal placement process, one of the most challenging aspects of arthroscopic hip surgery, an increased use of this minimally invasive technique could be possible. In addition to portal information, improvements to an existing computer aided system for arthroscopic hip surgery, including a new hip model and redesigned mechanical tracking linkage, were completed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

While beneficially decreasing the necessary incision size, arthroscopic hip surgery increases the surgical complexity due to loss of joint visibility. To ease such difficulty, a computer-aided mechanical navigation system was developed to present the location of the surgical tool relative to the patient¿s hip joint. A preliminary study reduced the position error of the tracking linkage with limited static testing trials. In this study, a correction method, including a rotational correction factor and a length correction function, was developed through more in-depth static testing. The developed correction method was then applied to additional static and dynamic testing trials to evaluate its effectiveness. For static testing, the position error decreased from an average of 0.384 inches to 0.153 inches, with an error reduction of 60.5%. Three parameters utilized to quantify error reduction of dynamic testing did not show consistent results. The vertex coordinates achieved 29.4% of error reduction, yet with large variation in the upper vertex. The triangular area error was reduced by 5.37%, however inconsistent among all five dynamic trials. Error of vertex angles increased, indicating a shape torsion using the developed correction method. While the established correction method effectively and consistently reduced position error in static testing, it did not present consistent results in dynamic trials. More dynamic paramters should be explored to quantify error reduction of dynamic testing, and more in-depth dynamic testing methodology should be conducted to further improve the accuracy of the computer-aided nagivation system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Osteotomies of the proximal femur for hip joint conditions are normally done at the intertrochanteric or subtrochanteric level. Intra-articular osteotomies would be more direct and therefore allow a more powerful correction with no or very little undesired side correction. However, concerns about the risk of vascular damage and osteonecrosis of the femoral head have so far basically excluded this technique from practical use. Based on detailed knowledge of the vascular anatomy of the proximal femur, an approach to safely dislocate the femoral head has been described and successfully performed. Experience as well as further studies of femoral head perfusion allowed a substantial extension of this approach, with subperiosteal exposure of the circumference of the femoral neck with constant intraoperative control of the blood supply to the head. Using the extended retinacular soft-tissue flap, four surgical techniques (relative neck lengthening, subcapital realignment in slipped capital femoral epiphysis, true femoral neck osteotomy, and femoral head reduction osteotomy) evolved or became safer with respect to perfusion of the femoral head. The extended retinacular soft-tissue flap offers the technical and biologic possibility for a new class of intra articular procedures. Although meticulous execution of the surgical steps is important, the procedures have a high level of safety for femoral head perfusion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Our purpose was to study the sensitivity, specificity, and predictive values for hip adhesions, labral tears, and articular cartilage lesions in patients who had open treatment for femoroacetabular impingement, had persistent symptoms, and had both magnetic resonance arthrography (MRA) with radial slices and hip arthroscopy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Joint-preserving hip surgery, either arthroscopic or open, increasingly is used for the treatment of symptomatic femoroacetabular impingement (FAI). As a consequence of surgery, thickening of the joint capsule and intraarticular adhesions between the labrum and joint capsule and between the femoral neck and the joint capsule have been observed. These alterations are believed to cause persistent pain and reduced range of motion. Because the diagnosis is made with MR arthrography, knowledge of the normal capsular anatomy and thickness on MRI in patients is important. To date there is no such information available.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: The purpose of this study was to examine whether arthroscopic adhesiolysis can relieve symptoms of patients with persistent pain after open surgical hip dislocation for femoroacetabular impingement syndrome without osseous or cartilaginous alterations. METHODS: This study comprised 16 consecutive patients (6 men and 10 women; mean age, 33.5 years [range, 19 to 60 years]) with persistent pain without osseous or cartilaginous alterations after surgical hip dislocation for the treatment of femoroacetabular impingement. At index surgery, all patients had osteochondroplasty of the head-neck junction and resection of the acetabular rim with reattachment of the labrum in 9 cases. All patients had preoperative magnetic resonance imaging-arthrogram and were treated with arthroscopy of the hip. RESULTS: At arthroscopy, all reattached labra were stable. In the cases without preservation of the labrum at the index operation, the joint capsule was attached at the level of the acetabular rim and synovitis was noticed. All patients had adhesions between the neck of the femur and joint capsule or between the labrum and capsule. In 3 patients the arthroscopic procedure was technically limited by massive thickening of the capsule. Overall, 81% of patients (13/16) showed less pain or were pain-free. The Merle d'Aubigné score improved from 13 points preoperatively to 16 points at the last follow-up. CONCLUSIONS: Persistent pain after surgical dislocation of the hip without evidence of cartilaginous and osseous alterations could result from intra-articular adhesions. Hip arthroscopy after previous surgery can be demanding because of scarring. If the adhesions can be released, good results can be achieved. LEVEL OF EVIDENCE: Level IV, therapeutic case series.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: The purpose of this study was to evaluate the precision of central hip arthroscopy in the assessment and treatment of pincer-type femoroacetabular impingement (FAI) avoiding the posterolateral portal, with its close proximity to the main arterial blood supply of the femoral head, the medial circumflex femoral artery. METHODS: Seven human cadaveric hips underwent arthroscopic trimming of the acetabular labrum and rim along a preoperatively defined 105 degrees arc of resection for treatment of a presumed pincer-type lesion. After the arthroscopic procedure, all specimens were dissected and measured for evaluation of the location, quantity, and quality of the area undergoing resection. RESULTS: The difference between the actual and planned arc of resection was 18.7 degrees +/- 4.7 degrees (range, 2 degrees to 34 degrees). This was mainly because of a lack of accuracy in the presumed posterior starting point (PSP), with a mean deviation of 19 degrees +/- 3.4 degrees (range, 10 degrees to 36 degrees). Correlation analysis showed that variance in the arc of resection was mainly dependent on the PSP (r = 0.739, P = .058). CONCLUSIONS: Central hip arthroscopy is a feasible option in treating anterosuperior pincer-type FAI by use of the anterior and anterolateral portals only. This cadaveric study showed that there is a significant risk of underestimating the actual arc of resection compared with the planned arc of resection for posterosuperior pincer-type lesions because of the modest accuracy in determining the PSP of the resection. CLINICAL RELEVANCE: Accurate preoperative planning and arthroscopic identification of anatomic landmarks at the acetabular side are crucial for the definition of the appropriate starting and ending points in the treatment of pincer-type FAI. Whereas anterosuperior pincer-type lesions can be addressed very precisely with our technique, the actual resection of posterosuperior lesions averaged 19 degrees less than the planned resection, which may have clinical implications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Femoroacetabular impingement (FAI) is an established cause of osteoarthrosis of the hip. Surgery is intended to remove the cause of impingement with hip dislocation and resection of osseous prominences of the acetabular rim and of the femoral head-neck junction. Using the Merle d'Aubigné score and qualitative categories, recent studies suggest good to excellent outcomes in 75% to 80% of patients after open surgery with dislocation of the femoral head. Unsatisfactory outcome is mainly related to pain, located either in the area of the greater trochanter or in the groin. There are several reasons for persisting groin pain. Joint degeneration with joint space narrowing and/or osteophyte formation, insufficient correction of the acetabula, and femoral pathology are known factors for unsatisfactory outcome. Recently, intraarticular adhesions between the femoral neck and joint capsule have been identified as an additional cause of postoperative groin pain. The adhesions form between the joint capsule and the resected area on the femoral neck and may lead to soft tissue impingement. MR-arthrography is used for diagnosis and the adhesions can be treated successfully by arthroscopy. While arthroscopic resection improves outcome it is technically demanding. Avoiding the formation of adhesions is important and is perhaps best accomplished by passive motion exercises after the initial surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE The purpose of this study was to evaluate if osseous correction of the femoral neck achieved arthroscopically is comparable to that achieved by surgical dislocation. METHODS We retrospectively analyzed all patients who were treated with hip arthroscopy or surgical dislocation for cam or mixed type femoroacetabular impingement (FAI) in our institution between 2006 and 2009. Inclusion criteria were complete clinical and radiologic documentation with standardized radiographs. Group 1 consisted of 66 patients (49 female patients, mean age 33.8 years) treated with hip arthroscopy. Group 2 consisted of 135 patients (91 male patients, mean age 31.2 years) treated with surgical hip dislocation. We compared the preoperative and postoperative alpha and gamma angles, as well as the triangular index. Mean follow-up was 16.7 months (range, 2 to 79 months). RESULTS In group 1, the mean alpha angle improved from 60.7° preoperatively to 47.8° postoperatively (P < .001) and the mean gamma angle improved from 47.3° to 44.5° (P < .001). Over time, the preoperative mean alpha angle increased from 56.3° in 2006 to 67.5° in 2009, whereas the postoperative mean alpha angle decreased from 51.2° in 2006 to 47.5° in 2009. In group 2, the mean alpha angle improved from 75.3° preoperatively to 44.8° postoperatively (P < .001), and the mean gamma angle improved from 65.1° to 52.2° (P < .001). Arthroscopic revision of intra-articular adhesions was performed in 4 patients (6.1%) in group 1 and 16 patients (12%) in group 2. Three patients (2.2%) in group 2 underwent revision for nonunion of the greater trochanter. CONCLUSIONS Osseous correction of cam-type FAI with hip arthroscopy is comparable to the correction achieved by surgical hip dislocation. There is a significant learning curve for hip arthroscopy, with postoperative osseous correction showing improved results with increasing surgical experience. LEVEL OF EVIDENCE Level III, retrospective comparative study.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Written by the surgeons of the Exeter Hip Team and their colleagues from around the world, this book describes 40 years of innovation and development with cemented hip replacement. Topics covered include the basic science behind successful cemented hip replacement, modern surgical techniques and recent advances. There is also extensive coverage of the revision techniques developed at Exeter and elsewhere, focussing on femoral and acetabular impaction grafting. Each chapter is a self-contained article with an emphasis, where appropriate, on practical techniques and surgical tips, supported by line drawings and intra-operative photographs.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Written by the surgeons of the Exeter Hip Team and their colleagues from around the world, this book describes 40 years of innovation and development with cemented hip replacement. Topics covered include the basic science behind successful cemented hip replacement, modern surgical techniques and recent advances. There is also extensive coverage of the revision techniques developed at Exeter and elsewhere, focussing on femoral and acetabular impaction grafting. Each chapter is a self-contained article with an emphasis, where appropriate, on practical techniques and surgical tips, supported by line drawings and intra-operative photographs.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Between 1987 and 1999, 540 revision total hip replacements in 487 patients were performed at our institution with the femoral impaction grafting technique with a cemented femoral stem. All patients were prospectively followed for 2-15years post-operatively with no loss to follow-up. 494 hips remained successfully in situ at an average 6.7years. The ten year survival rate was 98.0% (95% CI 96.2 to 99.8) with aseptic loosening as the endpoint and 84.2% (95% CI 78.5 to 89.9) for re-operation for any reason. Indication for surgery and the use of any kind of reinforcement significantly influenced outcome (p<0.001). This is the largest known series of revision THR with femoral impaction grafting and the results support continued use of this technique.