992 resultados para Arm Support
Resumo:
In this paper we have explored areas of application for health care manipulators and possible user groups. We have shown the steps in the design approach to the conceptual mechanism from the AAS. The future work will be measurement from properties of the muscle with the elbow parameterization test-bed to get a database to design one part of the control area from the AAS. More work on the mechanical design is required before a functional prototype can be built.
Resumo:
This paper argues for the systematic development and presentation of evidence-based guidelines for appropriate use of computers by children. The currently available guidelines are characterised and a proposed conceptual model presented. Five principles are presented as a foundation to the guidelines. The paper concludes with a framework for the guidelines, key evidence for and against guidelines, and gaps in the available evidence, with the aim of facilitating further discussion. Relevance to industry The current generation of children in affluent countries will typically have over 10 years of computer experience before they enter the workforce. Consequently, the primary prevention of computer-related health disorders and the development of good productivity skills for the next generation of workers needs to occur during childhood. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
The purpose of this study was to compare SEMG activities during axial load exercises on a stable base of support and on a medicine ball (relatively unstable). Twelve healthy male volunteers were tested (x = 23 +/- 7y). Surface EMG was recorded from the biceps brachii, anterior deltoid, clavicular portion of pectoralis major, upper trapezius and serratus anterior using surface differential electrodes. All SEMG data are reported as percentage of RMS mean values obtained in maximal voluntary contractions for each muscle studied. A 3-way within factor repeated measures analysis of variance was performed to compare RMS normalized values. The RMS normalized values of the deltoid were always greater during the exercises performed on a medicine ball in relation to those performed on a stable base of support. The trapezius showed greater mean electric activation amplitude values on the wall-press exercise on a medicine ball, and the pectoralis major on the push-up. The serratus and biceps did not show significant differences of electric activation amplitude in relation to both tested bases of support. Independent of the base of support, none of the studied muscles showed significant differences of electric activation amplitude during the bench-press exercise. The results contribute to the identification of the levels of muscular activation amplitude during exercises that are common in clinical practice of rehabilitation of the shoulder and the differences in terms of type of base of support used. (C) 2006 Elsevier Ltd. All rights reserved.
Resumo:
The electromyographic activity of the biceps brachii - BB (long head), triceps brachii - TB (long head) and deltoideus - DA (clavicular portion) muscles, during the going (G) and return (R) phases in front support exercise, as well the efficacy of this exercise for the development of these muscles strength were studied in 10 male volunteers. The values were normalized through maximum voluntary isometric contraction (MVIC = 100%) and statistically analyzed using the Friedman, DMS and Wilcoxon non-parametric test. A value of p≤0.05 indicated significance (Campos, 1983). All the muscles presented higher electromyographic activity in the return phase of the movement. The triceps brachii was the muscle which had higher activity in both phases of the movement. It was concluded that the front support exercise is efficient for strength development mainly in the triceps brachii muscle.
Resumo:
This study aims at quantifying through electromyography the actions of the biceps brachii-BB (long head), tríceps brachii- TB (long head) and deltoideus-DA (clavicular portion) muscles, during the going (G) and return (R) phases in back support exercises. Surface electrodes were placed at the muscles, according to DELAGI (1981). It was used a specific software and a AID plate to take the signals. After being collected, the records were processed resulting in efficient values (RMS), were normalized by maximum isometric contraction (MVIC=100%) and statistically analysed using the Friedman, DSM and Wilcox non-parametric tests. All the muscles presented electromyographic activity of the movements. The triceps brachii was the muscle with higher activity in both phases of the movement. It was concluded that the exercise is indicated for the arm muscle strength development.
Resumo:
"June 1979."
Resumo:
Includes index.
Resumo:
Includes index.
Resumo:
Includes index.
Resumo:
Because the structure of the spine is inherently unstable, muscle activation is essential for the maintenance of trunk posture and intervertebral control when the limbs are moved. To investigate how the central nervous system deals with this situation the temporal components of the response of the muscles of the trunk were evaluated during rapid limb movement performed in response to a visual stimulus. Fine-wire electromyography (EMG) electrodes were inserted into transversus abdominis (TrA), obliquus internus abdominis (OI) and obliquus externus abdominis (OE) of 15 subjects under the guidance of real-time ultrasound imaging. Surface electrodes were placed over rectus abdominis (RA), lumbar multifidus (MF) and the three parts of deltoid. In a standing position, ten repetitions of shoulder flexion, abduction and extension were performed by the subjects as fast as possible in response to a visual stimulus. The onset of TrA EMG occurred in advance of deltoid irrespective of the movement direction. The time to onset of EMC activity of OI, OE, RA and MF varied with the movement direction, being activated earliest when the prime action of the muscle opposed the reactive forces associated with the specific limb movement. It is postulated that the non-direction-specific contraction of TrA may be related to the control of trunk. stability independent of the requirement for direction-specific control of the centre of gravity in relation to the base of support.
Resumo:
AB Study Design. A cross-sectional study was conducted. Objective. To determine the activity of the deep and superficial fibers of the lumbar multifidus during voluntary movement of the arm. Summary of Background Data. The multifidus contributes to stability of the lumbar spine. Because the deep and superficial parts of the multifidus are near the center of lumbar joint rotation, the superficial fibers are well suited to control spine orientation, and the deep fibers to control intervertebral movement. However, there currently are limited in vivo data to support this distinction. Methods. Electromyographic activity was recorded in both the deep and superficial multifidus, transversus abdominis, erector spinae, and deltoid using selective intramuscular electrodes and surface electrodes during single and repetitive arm movements. The latency of electromyographic onset in each muscle during single movements and the pattern of electromyographic activity during repetitive movements were compared between muscles. Results. With single arm movements, the onset of electromyography in the erector spinae and superficial multifidus relative to the deltoid was dependent on the direction of movement, but the onset in the deep multifidus and transversus abdominis was not. With repetitive arm movements, peaks in superficial multifidus and erector spinae electromyography occurred only during flexion for most subjects, whereas peaks in deep multifidus electromyography occurred during movement in both directions. Conclusions. The deep and superficial fibers of the multifidus are differentially active during single and repetitive movements of the arm. The data from this study support the hypothesis that the superficial multifidus contributes to the control of spine orientation, and that the deep multifidus has a role in controlling intersegmental motion. (C) 2002 Lippincott Williams & Wilkins, Inc.
Resumo:
The assessment of concrete mechanical properties during construction of concrete structures is of paramount importance for many intrinsic operations. However many of the available non-destructive methods for mechanical properties have limitations for use in construction sites. One of such methodologies is EMM-ARM, which is a variant of classic resonant frequency methods. This paper aims to demonstrate the efforts towards in-situ applicability of EMMARM, as to provide real-time information about concrete mechanical properties such as E-modulus and compressive strength. To achieve the aforementioned objective, a set of adaptations to the method have been successfully implemented and tested: (i) the reduction of the beam span; (ii) the use of a different mould material and (iii) a new support system for the beams. Based on these adaptations, a reusable mould was designed to enable easier systematic use of EMMARM. A pilot test was successfully performed under in-situ conditions during a bridge construction.
Resumo:
BACKGROUND Phase-IV, open-label, single-arm study (NCT01203917) to assess efficacy and safety/tolerability of first-line gefitinib in Caucasian patients with stage IIIA/B/IV, epidermal growth factor receptor (EGFR) mutation-positive non-small-cell lung cancer (NSCLC). METHODS Treatment: gefitinib 250 mg day(-1) until progression. Primary endpoint: objective response rate (ORR). Secondary endpoints: disease control rate (DCR), progression-free survival (PFS), overall survival (OS) and safety/tolerability. Pre-planned exploratory objective: EGFR mutation analysis in matched tumour and plasma samples. RESULTS Of 1060 screened patients with NSCLC (859 known mutation status; 118 positive, mutation frequency 14%), 106 with EGFR sensitising mutations were enrolled (female 70.8%; adenocarcinoma 97.2%; never-smoker 64.2%). At data cutoff: ORR 69.8% (95% confidence interval (CI) 60.5-77.7), DCR 90.6% (95% CI 83.5-94.8), median PFS 9.7 months (95% CI 8.5-11.0), median OS 19.2 months (95% CI 17.0-NC; 27% maturity). Most common adverse events (AEs; any grade): rash (44.9%), diarrhoea (30.8%); CTC (Common Toxicity Criteria) grade 3/4 AEs: 15%; SAEs: 19%. Baseline plasma 1 samples were available in 803 patients (784 known mutation status; 82 positive; mutation frequency 10%). Plasma 1 EGFR mutation test sensitivity: 65.7% (95% CI 55.8-74.7). CONCLUSION First-line gefitinib was effective and well tolerated in Caucasian patients with EGFR mutation-positive NSCLC. Plasma samples could be considered for mutation analysis if tumour tissue is unavailable.