957 resultados para Arm Circumference


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: In order to determine the relationship between some maternal anthropometric indicators and birth weight, crown-heel length and newborn's head circumference, 92 pregnant women were followed through at the prenatal service of hospital in S. Paulo, Brazil. MATERIAL AND METHOD: The following variables were established for the mother: weight, height, mid-upper arm circumference, pre-pregnancy weight, gestational weight gain and Quetelet's index. For the newborn the following variables were recorded: birth weight, crown-heel length, head circumference and gestational age by Dubowitz's method. RESULTS: Significant associations were noted between gestational age and newborn variables. In addition, maternal mid-arm circumference (MUAC) and pre-pregnancy weight were found to be positively correlated to birth weight (r=0.399; r=0.378, respectively). The multivariate linear regression shows that gestational age, mother's arm circumference and pre-pregnancy weight continue to be significant predictors of birth weight. On the other hand, only gestational age and mother's age was associated with crown-heel length. Similarly MUAC was significantly associated with crown-heel length (r= 0.306; P=0.0030). CONCLUSION: Maternal mid-upper arm circumference is a potential indicator of maternal nutritional status. It could be used in association with other anthropometric measurements, instead of pre-pregnancy weight, as an alternative indicator to assess women at risk of poor pregnancy outcome.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We aimed to evaluate the classification of arm circumference (AC) in pre-school children by using National Center for Health Statistics (NCHS/CDC-2000) and World Health Organization (WHO-2006) references. We evaluated 205 children: weight, height and AC were assessed and the body mass index (BMI) was calculated. The BMI values were classified into Z-scores by the WHO referential. The AC was classified into Z-cores by two references, comparing the whole-sample value and among groups (tercis) of BMI Z-score. The correlation was also evaluated between differences of AC with BMI Z-score. The WHO referential classified the AC in Z-scores greater than the NCHS/CDC, which is more specific and less sensitive than the NCHS/CDC for lean children and at the same time more sensitive and less specific for children with overweight. In conclusion, a significant difference in the AC classification occurs according to the referential used.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Because of its simplicity and low cost, arm circumference (AC) is being used increasingly in screening for protein energy malnutrition among pre-school children in many parts of the developing world, especially where minimally trained health workers are employed. The objectives of this study were as follows: (1) To determine the relationship of the AC measure with weight for age and weight for height in the detection of malnutrition among pre-school children in a Guatemalan Indian village. (2) To determine the performance of minimally trained promoters under field conditions in measuring AC, weight and height. (3) To describe the practical aspects of taking AC measures versus weight, age and height.^ The study was conducted in San Pablo La Laguna, one of four villages situated on the shores of Lake Atitlan, Guatemala, in which a program of simplified medical care was implemented by the Institute for Nutrition for Central America and Panama (INCAP). Weight, height, AC and age data were collected for 144 chronically malnourished children. The measurements obtained by the trained investigator under the controlled conditions of the health post were correlated against one another and AC was found to have a correlation with weight for age of 0.7127 and with weight for height of 0.7911, both well within the 0.65 to 0.80 range reported in the literature. False positive and false negative analysis showed that AC was more sensitive when compared with weight for height than with weight for age. This was fortunate since, especially in areas with widespread chronic malnutrition, weight for height detects those acute cases in immediate danger of complicating illness or death. Moreover, most of the cases identified as malnourished by AC, but not by weight for height (false positives), were either young or very stunted which made their selection by AC better than weight for height. The large number of cases detected by weight for age, but not by AC (false negative rate--40%) were, however, mostly beyond the critical age period and had normal weight for heights.^ The performance of AC, weight for height and weight for age under field conditions in the hands of minimally trained health workers was also analyzed by correlating these measurements against the same criterion measurements taken under ideally controlled conditions of the health post. AC had the highest correlation with itself indicating that it deteriorated the least in the move to the field. Moreover, there was a high correlation between AC in the field and criterion weight for height (0.7509); this correlation was almost as high as that for field weight for height versus the same measure in the health post (0.7588). The implication is that field errors are so great for the compounded weight for height variable that, in the field, AC is about as good a predictor of the ideal weight for height measure.^ Minimally trained health workers made more errors than the investigator as exemplified by their lower intra-observer correlation coefficients. They consistently measured larger than the investigator for all measures. Also there was a great deal of variability between these minimally trained workers indicating that careful training and followup is necessary for the success of the AC measure.^ AC has many practical advantages compared to the other anthropometric tools. It does not require age data, which are often unreliable in these settings, and does not require sophisticated subtraction and two dimensional table-handling skills that weight for age and weight for height require. The measure is also more easily applied with less disturbance to the child and the community. The AC tape is cheap and not easily damaged or jarred out of calibration while being transported in rugged settings, as is often the case with weight scales. Moreover, it can be kept in a health worker's pocket at all times for continual use in a widespread range of settings. ^

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective: To compare measurements of the upper arm cross-sectional areas (total arm area,arm muscle area, and arm fat area of healthy neonates) as calculated using anthropometry with the values obtained by ultrasonography. Materials and methods: This study was performed on 60 consecutively born healthy neonates: gestational age (mean6SD) 39.661.2 weeks, birth weight 3287.16307.7 g, 27 males (45%) and 33 females (55%). Mid-arm circumference and tricipital skinfold thickness measurements were taken on the left upper mid-arm according to the conventional anthropometric method to calculate total arm area, arm muscle area and arm fat area. The ultrasound evaluation was performed at the same arm location using a Toshiba sonolayer SSA-250AÒ, which allows the calculation of the total arm area, arm muscle area and arm fat area by the number of pixels enclosed in the plotted areas. Statistical analysis: whenever appropriate, parametric and non-parametric tests were used in order to compare measurements of paired samples and of groups of samples. Results: No significant differences between males and females were found in any evaluated measurements, estimated either by anthropometry or by ultrasound. Also the median of total arm area did not differ significantly with either method (P50.337). Although there is evidence of concordance of the total arm area measurements (r50.68, 95% CI: 0.55–0.77) the two methods of measurement differed for arm muscle area and arm fat area. The estimated median of measurements by ultrasound for arm muscle area were significantly lower than those estimated by the anthropometric method, which differed by as much as 111% (P,0.001). The estimated median ultrasound measurement of the arm fat was higher than the anthropometric arm fat area by as much as 31% (P,0.001). Conclusion: Compared with ultrasound measurements using skinfold measurements and mid-arm circumference without further correction may lead to overestimation of the cross-sectional area of muscle and underestimation of the cross-sectional fat area. The correlation between the two methods could be interpreted as an indication for further search of correction factors in the equations.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Brachial circumference (BC), also known as upper arm or mid arm circumference, can be used as an indicator of muscle mass and fat tissue, which are distributed differently in men and women. Analysis of anthropometric measures of peripheral fat distribution such as BC could help in understanding the complex pathophysiology behind overweight and obesity. The purpose of this study is to identify genetic variants associated with BC through a large-scale genome-wide association scan (GWAS) meta-analysis. We used fixed-effects meta-analysis to synthesise summary results across 14 GWAS discovery and 4 replication cohorts comprising overall 22,376 individuals (12,031 women and 10,345 men) of European ancestry. Individual analyses were carried out for men, women, and combined across sexes using linear regression and an additive genetic model: adjusted for age and adjusted for age and BMI. We prioritised signals for follow-up in two-stages. We did not detect any signals reaching genome-wide significance. The FTO rs9939609 SNP showed nominal evidence for association (p<0.05) in the age-adjusted strata for men and across both sexes. In this first GWAS meta-analysis for BC to date, we have not identified any genome-wide significant signals and do not observe robust association of previously established obesity loci with BC. Large-scale collaborations will be necessary to achieve higher power to detect loci underlying BC.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background and Purpose. Arm lymphedema following breast cancer In this study, we assessed the surgery is a continuing problem. reliability and validity of circumferential measurements and water displacement for measuring upper-limb volume. Subjects. Participants included subjects who had had breast cancer surgery, including axillary dissection-19 with and 22 without a diagnosis of arm lymphedema-and 25 control subjects. Methods. Two raters measured each subject by using circumferential tape measurements at specified distances from the fingertips and in relation to anatornic landmarks and by using water displacement. Interrater reliability was calculated by analysis of variance and multilevel modeling. Volumes from circumferential measurements were compared with those from water displacement by use of means and correlation coefficients, respectively. The standard error of measurement, minimum detectable change (MDC), and limits of agreement (LOA) for volumes also were calculated. Results. Arm volumes obtained with these methods had high reliability. Compared with volumes from water displacement, volumes from circumferential measurements had high validity, although these volumes were slightly larger. Expected differences between subjects with and without clinical lymphedema following breast cancer were found. The MDC of volumes or the error associated with a single measure for data based oil anatomic landmarks was lower than that based oil distance from fingertips. The mean LOA with water displacement were lower for data based on anatomic landmarks than for data based on distance from fingertips. Discussion and Conclusion. Volumes calculated from anatomic landmarks are reliable, valid, and more accurate than those obtained from circumferential measurements based on distance from fingertips.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aims of this study were to examine the plasma concentrations of inflammatory mediators including cytokines induced by a single bout of eccentric exercise and again 4 weeks later by a second bout of eccentric exercise of the same muscle group. Ten untrained male subjects performed two bouts of the eccentric exercise involving the elbow flexors (6 sets of 5 repetitions) separated by four weeks. Changes in muscle soreness, swelling, and function following exercise were compared between the bouts. Blood was sampled before, immediately after, 1 h, 3 h, 6 h, 24 h (1 d), 48 h (2 d), 72 h (3 d), 96 h (4 d) following exercise bout to measure plasma creatine kinase (CK) activity, plasma concentrations of myoglobin (Mb), interleukin (IL)-1 beta, IL-1 receptor antagonist (IL-1ra), IL-4, IL-6, IL-8, IL-10, IL-12p40, tumor necrosis factor (TNF)-alpha, granulocyte colony-stimulating factor (G-CSF), myeloperoxidase (MPO), prostaglandin E-2 (PGE(2)), heat shock protein (HSP) 60 and 70. After the first bout, muscle soreness increased significantly, and there was also significant increase in upper arm circumference; muscle function decreased and plasma CK activity and Mb concentration increased significantly. These changes were significantly smaller after the second bout compared to the first bout, indicating muscle adaptation to the repeated bouts of the eccentric exercise. Despite the evidence of greater muscle damage after the first bout, the changes in cytokines and other inflammatory mediators were quite minor, and considerably smaller than that following endurance exercise. These results suggest that eccentric exercise-induced muscle damage is not associated with the significant release of cytokines into the systemic circulation. After the first bout, plasma G-CSF concentration showed a small but significant increase, whereas TNF-alpha and IL-8 showed significant decreases compared to the pre-exercise values. After the second bout, there was a significant increase in IL-10, and a significant decrease in IL-8. In conclusion, although there was evidence of severe muscle damage after the eccentric exercise, this muscle damage was not accompanied by any large changes in plasma cytokine concentrations. The minor changes in systemic cytokine concentration found in this study might reflect more rapid clearance from the circulation, or a lack of any significant metabolic or oxidative demands during this particular mode of exercise. In relation to the adaptation to the muscle damage, the anti-inflammatory cytokine IL-10 might work as one of the underlying mechanisms of action.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to evaluate the arterial and venous blood flow in women who underwent upper limb axillary dissection surgery for the treatment of breast cancer. Sixty women were divided into two groups: group 1 (G1)-30 women who underwent breast surgery with axillary dissection level II or III (55.6 +/- A 8.6 years); group 2 (G2)-control, 30 women with no breast cancer (57.4 +/- A 7.0 years). Blood flow profile was evaluated by a continuous wave ultrasound Doppler device (Nicolet Vascular Versalab SE(A (R))) with an 8 MHz probe. Axillary, brachial arteries and veins, arm circumference, volumes, and the ankle-brachial index (ABI) were examined. Wilcoxon test and Mann-Whitney tests were applied to analyze blood flow velocity intra-group and between G1 and G2, respectively. The G1 results showed no lymphedema and no peripheral arterial disease (ABI > 0.9). Moreover, the mean blood flow velocity of the vessels ipsilateral to the surgery was significantly higher than the contralateral ones for all vessels examined (P < 0.05). The mean velocity of blood flow of the vessels contralateral to surgery was significantly higher than the axillary artery in G2 (P < 0.05). It can be concluded that women who underwent axillary dissection due to breast cancer showed probable stenosis in the arterial and venous axillary and brachial vessels of the upper limb ipsilateral to the surgery, confirmed by the increase of blood flow velocity, and such obstruction might affect the limb contralateral to the operation site.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Nutrition therapy (NT) is essential for the care of critically ill children. Inadequate feeding leads to malnutrition and may increase the patient`s risk of morbidity and mortality. The aim of this study was to describe the NT used in a tertiary pediatric intensive care unit (PICU). Methods: The authors evaluated NT administered to 90 consecutive patients who were hospitalized for 7 days in the PICU of Instituto da Crianca, Hospital das Clinicas, Universidade de Sao Paulo, Brazil. NT was established according to the protocol provided by the institution`s NT team. NT provided a balance of fluids and nutrients and was monitored with a weekly anthropometric nutrition assessment and an evaluation of complications. Results: NT was initiated, on average, within 72 hours of hospitalization. Most children (80%) received enteral nutrition (EN) therapy; of these, 35% were fed orally and the rest via nasogastric or postpyloric tube. There were gastrointestinal complications in patients (5%) who needed a postpyloric tube. Parenteral nutrition (PN) was used in only 10% of the cases, and the remaining 10% received mixed NT (EN + PN). The average calorie and protein intake was 82 kcal/kg and 2.7 g/kg per day. Arm circumference and triceps skinfold thickness decreased. Conclusions: The use of EN was prevalent in the tertiary PICU, and few clinical complications occurred. There was no statistically significant change in most anthropometric indicators evaluated during hospitalization, which suggests that NT probably helped patients maintain their nutrition status. (JPEN J Parenter Enteral Nutr. 2011;35:523-529)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Neonatal anthropometry is an inexpensive, noninvasive and convenient tool for bedside evaluation, especially in sick and fragile neonates. Anthropometry can be used in neonates as a tool for several purposes: diagnosis of foetal malnutrition and prediction of early postnatal complications; postnatal assessment of growth, body composition and nutritional status; prediction of long-term complications including metabolic syndrome; assessment of dysmorphology; and estimation of body surface. However, in this age group anthropometry has been notorious for its inaccuracy and the main concern is to make validated indices available. Direct measurements, such as body weight, length and body circumferences are the most commonly used measurements for nutritional assessment in clinical practice and in field studies. Body weight is the most reliable anthropometric measurement and therefore is often used alone in the assessment of the nutritional status, despite not reflecting body composition. Derived indices from direct measurements have been proposed to improve the accuracy of anthropometry. Equations based on body weight and length, mid-arm circumference/head circumference ratio, and upper-arm cross-sectional areas are among the most used derived indices to assess nutritional status and body proportionality, even though these indices require further validation for the estimation of body composition in neonates.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The effect of the intake of polynsaturated long chain fatty acids (LCPUFAs) during pregnancy on fetal body composition has been assessed by studies using mostly neonatal anthropometry. Their results have been inconsistent, probably because neonatal anthropometry has several validity limitations. Air displacement plethismography (ADP) is a recently validated non-invasive method for assessing body composition in neonates. Objective: To determine the effect of the intake of LCPUFAs during pregnancy on the body composition of term neonates, measured by ADP. Methods: Cross-sectional study of a convenience sample of healthy full-term neonates and their mothers. The diet during pregnancy was assessed using a validated semi-quantitative food frequency questionnaire; Food Processor Plus® was used to convert food intake into nutritional values. Body composition was estimated by anthropometry and measured by ADP using Pea Pod™ Life Measurements Inc (fat mass - FM, fat-free mass and %FM) within the first 72h after birth. Univariate and multivariate analysis (linear regression model) were performed. Results: 54 mother-neonate pairs were included. Multivariate analysis adjusted to the maternal body mass index shows positive association between LCPUFAs intake and neonatal mid-arm circumference (= 0,610, p = 0,019) and negative association between n-6:n-3 ratio intake and neonatal %FM (= -2,744, p=0,066). Conclusion: To the best of our knowledge, this is the first study on this subject using ADP and showing a negative association between LCPUFAs n-6:n-3 ratio intake in pregnancy and neonatal %FM. This preliminary finding requires confirmation increasing the study power with a greater sample and performing interventional studies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The anthropometric (body weight, height, upper arm circumference, triceps and subescapular skinfolds; Quetelet index and arm muscle circunference) and blood biochemistry (proteins and lipids) parameters were evaluated in 93 males and 27 females, 17-72 years old voluntaries living in the malarial endemic area of Humaita city (southwest Amazon). According to their malarial history they were assembled in four different groups: G1-controls without malarial history (n:30); G2 - controls with malarial history but without actual manifestation of the disease (n:40); G3 - patients with Plasmodium vivax (n:19) and G4 - patients with Plasmodium falciparum (n:31). The malarial status was stablished by clinical and laboratory findings. The overall data of anthropometry and blood biochemistry discriminated the groups differently. The anthropometric data were low sensitive and contrasted only the two extremes (G1>G4) whereas the biochemistry differentiated two big groups, the healthy (G1+G2) and the patients (G3+G4). The nutritional status of the P. falciparum patients was highly depressed for most of the studied indices but none was sensitive enough to differentiate this group from the P. vivax group (G3). On the other hand the two healthy groups could be differentiated through the levels of ceruloplasmin (G1G2). Thus it seems that the malaria-malnourishment state exists and the results could be framed either as a consequence of nutrient sink and/or the infection stress both motivated by the parasite.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Sixteen patients with endemic pemphigus foliaceus were submitted to nutritional evaluation. Ten had the localized form of the disease (Group G1) and six the disseminated form (Group G2). The patients were submitted to anthropometric measurements (weight, height, Quetelét index, tricipital skin fold, subscapular skin fold, arm circumference, arm muscle circumference, arm area, arm muscle area, and arm adipose area) and to laboratory evaluation by protein electrophoresis. Arm circumference, arm area and arm muscle area showed lower values in G2 than in G1. Weight and arm muscle circumference tended to the lower in G2 than in G1. Protein electrophoresis showed decreased albumin levels in both groups, with lower values in G2. Overall analysis of the results permits us to conclude that patients with endemic pemphigus foliaceus present signs and symptoms of protein, but not calorie, malnutrition and that this malnutrition is more marked in patients with disseminated pemphigus foliaceus.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

RESUMO: Contexto: Indicadores fidedignos da composição corporal são importantes na orientação das estratégias nutricionais de recém-nascidos e pequenos lactentes submetidos a cuidados intensivos. O braço é uma região acessível para avaliar a composição corporal regional, pela medida dos seus compartimentos. A antropometria e a ultrassonografia (US) são métodos não invasivos, relativamente económicos, que podem ser usados à cabeceira do paciente na medição desses compartimentos, embora esses métodos não tenham ainda sido validados neste subgrupo etário. A ressonância magnética (RM) pode ser usada como método de referência na validação da medição dos compartimentos do braço. Objectivo: Validar em lactentes pré-termo, as medidas do braço por antropometria e por US. Métodos: Foi estudada uma coorte de recém-nascidos admitidos consecutivamente na unidade de cuidados intensivos neonatais, com  33 semanas de idade de gestação e peso adequado para a mesma, sem anomalias congénitas major e não submetidas a diuréticos ou oxigenoterapia no momento da avaliação. Nas vésperas da alta, foram efectuadas medições do braço, com ocultação, pelos métodos antropométrico, ultrassonográfico e RM. As medidas antropométricas directas foram: peso (P), comprimento (C), perímetro cefálico (PC), perímetro braquial (PB) e prega cutânea tricipital (PT). As área braquial total, área muscular (AM) e área adiposa foram calculadas pelos métodos de Jeliffee & Jeliffee e de Rolland-Cachera. Utilizando uma sonda PSH-7DLT de 7 Hz no ecógrafo Toshiba SSH 140A foram medidos os perímetros braquial e muscular e calculadas automaticamente as áreas braquial e muscular, sendo a área adiposa obtida por subtracção. Como método de referência foi utilizada a RM – Philips Gyroscan ACS-NT, Power-Track 1000 ®, 1.5 Tesla com uma antena de quadratura do joelho. Na análise estatística foram utilizados os métodos paramétricos e não paramétricos, conforme adequado. Resultados: Foram incluídas 30 crianças, nascidas com ( ±DP) 30.7 ±1.9 semanas de gestação, pesando 1380 ±325g, as quais foram avaliadas às 35.4 ±1.1 semanas de idade corrigida, quando pesavam 1786 ±93g. Nenhuma das medidas antropométricas, individualmente, constitui um indicador aceitável (r2 <0.5) das medições por RM. A melhor e mais simples equação alternativa encontrada é a que estima a AM (r2 = 0.56), derivada dos resultados da análise de regressão múltipla: AMRM = (P x 0.17) + (PB x 5.2) – (C x 6) – 150, sendo o P expresso em g, o C e o PB em cm. Nenhuma das medidas ultrassonográficas constitui um indicador aceitável (r2 <0.4) das medições por RM. Conclusões: A antropometria e as medidas ultrassonográficas do braço não são indicadores fidedignos da composição corporal regional em lactentes pré-termo, adequados para a idade de gestação.----------ABSTRACT: Background: Accurate predictors for body composition are valuable tools guiding nutritional strategies in infants needing intensive care. The upper-arm is a part of the body that is easily accessible and convenient for assessing the regional body composition, throughout the assessment of their compartments. Anthropometry and by ultrasonography (US) are noninvasive and relatively nonexpensive methods for bedside assessment of the upper-arm compartments. However, these methods have not yet been validated in infants. Magnetic resonance imaging (MRI) may be used as gold standard to validate the measurements of the upper-arm compartments. Objective: To validate the upper-arm measurements by anthropometry and by US in preterm infants. Methods: A cohort of neonates consecutively admitted at the neonatal intensive care unit, appropriate for gestational age, with  33 weeks, without major congenital abnormalities and not subjected to diuretics or oxygen therapy, was assessed. Before the discharge, the upper-arm was blindly measured by anthropometry, US and MRI. The direct anthropometric parameters measured were: weight (W), length (L), head circumference (HC), mid-arm circumference (MAC), and tricipital skinfold thickness. The arm area (AA), arm muscle area (AMA) and arm fat area were calculated applying the methods proposed by Jeliffee & Jeliffee and by Rolland-Cachera. Using the sonolayer Toshiba SSH 140A and the probe PSH-7DLT 7Hz, the arm and muscle perimeters were measured by US, the arm and muscle areas included were automatically calculated, and the fat area was calculated by subtraction. The MR images were acquired on a 1.5-T Philips Gyroscan ACS-NT, Power-Track 1000 scanner, and a knee coil was chosen for the upper-arm measurements. For statistical analysis parametric and nonparametric methods were used as appropriate. Results: Thirty infants born with ( ±SD) 30.7 ±1.9 weeks of gestational age and weighing 1380 ±325g were included in the study; they were assessed at 35.4 ±1.1 weeks of corrected age, weighing 1786 ±93g. None of the anthropometric measurements are individually acceptable (r2 <0.5) for prediction of the measurements obtained by MRI. The best and simple alternative equation found is the equation for prediction of the AMA (r2 = 0.56), derived from the results of multiple regression analysis: AMARM = (W x 0.17) + (MAC x 5.2) – (L x 6) – 150, being the W expressed in g, and L and MAC in cm. None of the ultrasonographic measurements are acceptable (r2 <0.5) predictors for the measurements obtained by MRI. Conclusions: The measurements of the upper-arm by anthropometry and by US are not accurate predictors for the regional body composition in preterm appropriate for gestational age infants.