973 resultados para Arc flash energies
Resumo:
The traditional operational and hazard control paradigm of an electrical installation has several issues pertaining to the diversity of equipment. A large maintenance inventory is a reason for concern for any manager, but the arc flash hazard is a particularly new phenomenon and the effects of equipment diversity on this phenomenon are even newer. The class of arc hazard can be increased, simply by changing the fuse link or circuit breaker manufacturer. Management pressure to operate as well as non-standard practices and installations are also partly responsible. The aim of this study is to take a typical situation in an industrial plant and to statistically simulate, by means of a dedicated software program, the fuse arc flash interruption performance of various manufacturers. The purpose of this study is to obtain a more objective indication of the influence of different fuse link manufacturers on arc flash incident energy. © 2011 IEEE.
Resumo:
The traditional operational and hazard control paradigm of an electrical installation has several issues pertaining to the diversity of equipment. A large maintenance inventory is a reason for concern for any manager, but the arc-flash hazard is a particularly new phenomenon, and the effects of equipment diversity on this phenomenon are even newer. The class of arc hazard can be simply increased by changing the fuse link or circuit breaker manufacturer. Management pressure to operate as well as nonstandard practices and installations are also partly responsible. The aim of this article is to take a typical situation in an industrial plant and to statistically simulate, by means of a dedicated software program, the fuse arc-flash interruption performance of various manufacturers. The purpose of this article is to obtain a more objective indication of the influence of different fuse link manufacturers on arc-flash incident energy. © 1975-2012 IEEE.
Resumo:
The electric utility business is an inherently dangerous area to work in with employees exposed to many potential hazards daily. One such hazard is an arc flash. An arc flash is a rapid release of energy, referred to as incident energy, caused by an electric arc. Due to the random nature and occurrence of an arc flash, one can only prepare and minimize the extent of harm to themself, other employees and damage to equipment due to such a violent event. Effective January 1, 2009 the National Electric Safety Code (NESC) requires that an arc-flash assessment be performed by companies whose employees work on or near energized equipment to determine the potential exposure to an electric arc. To comply with the NESC requirement, Minnesota Power’s (MP’s) current short circuit and relay coordination software package, ASPEN OneLinerTM and one of the first software packages to implement an arc-flash module, is used to conduct an arc-flash hazard analysis. At the same time, the package is benchmarked against equations provided in the IEEE Std. 1584-2002 and ultimately used to determine the incident energy levels on the MP transmission system. This report goes into the depth of the history of arc-flash hazards, analysis methods, both software and empirical derived equations, issues of concern with calculation methods and the work conducted at MP. This work also produced two offline software products to conduct and verify an offline arc-flash hazard analysis.
Resumo:
The main obstacle for the application of high quality diamond-like carbon (DLC) coatings has been the lack of adhesion to the substrate as the coating thickness is increased. The aim of this study was to improve the filtered pulsed arc discharge (FPAD) method. With this method it is possible to achieve high DLC coating thicknesses necessary for practical applications. The energy of the carbon ions was measured with an optoelectronic time-of-flight method. An in situ cathode polishing system used for stabilizing the process yield and the carbon ion energies is presented. Simultaneously the quality of the coatings can be controlled. To optimise the quality of the deposition process a simple, fast and inexpensive method using silicon wafers as test substrates was developed. This method was used for evaluating the suitability of a simplified arc-discharge set-up for the deposition of the adhesion layer of DLC coatings. A whole new group of materials discovered by our research group, the diamond-like carbon polymer hybrid (DLC-p-h) coatings, is also presented. The parent polymers used in these novel coatings were polydimethylsiloxane (PDMS) and polytetrafluoroethylene (PTFE). The energy of the plasma ions was found to increase when the anode-cathode distance and the arc voltage were increased. A constant deposition rate for continuous coating runs was obtained with an in situ cathode polishing system. The novel DLC-p-h coatings were found to be water and oil repellent and harder than any polymers. The lowest sliding angle ever measured from a solid surface, 0.15 ± 0.03°, was measured on a DLC-PDMS-h coating. In the FPAD system carbon ions can be accelerated to high energies (≈ 1 keV) necessary for the optimal adhesion (the substrate is broken in the adhesion and quality test) of ultra thick (up to 200 µm) DLC coatings by increasing the anode-cathode distance and using high voltages (up to 4 kV). An excellent adhesion can also be obtained with the simplified arc-discharge device. To maintain high process yield (5µm/h over a surface area of 150 cm2) and to stabilize the carbon ion energies and the high quality (sp3 fraction up to 85%) of the resulting coating, an in situ cathode polishing system must be used. DLC-PDMS-h coating is the superior candidate coating material for anti-soiling applications where also hardness is required.
Resumo:
In this work, a laser-produced plasma extreme ultraviolet source and a free electron laser were used to create Ne photo-ionized plasmas. In both cases, a radiation beam was focused onto a gas stream injected into a vacuum chamber synchronously with the radiation pulse. Extreme ultraviolet radiation from the plasma spanned a wide spectral range with pronounced maximum centered at lambda = 11 +/- 1 nm while the free electron laser pulses were emitted at a wavelength of 32 nm. The power density of the focused plasma radiation was approximately 2 x 10(7) W/cm(2) and was seven orders of magnitude lower compared with the focused free electron laser beam. Radiation fluences in both experimental conditions were comparable. Despite quite different spectral characteristics and extremely different power densities, emission spectra of both photo-ionized plasmas consist of the same spectral lines within a wavelength range of 20 to 50 nm, however, with different relative intensities of the corresponding lines. The dominating spectral lines originated from singly charged ions (Ne II); however, Ne III lines were also detected. Additionally, computer simulations of the emission spectra, obtained for photo-ionized plasmas, driven by the plasma extreme ultraviolet source, were performed. The corresponding measured and calculated spectra are presented. An electron temperature and ionic composition were estimated. Differences between the experimental spectra, obtained for both irradiation conditions, were analyzed. The differences were attributed mainly to different energies of driving photons.
Resumo:
From direct observations of the longitudinal development of ultra-high energy air showers performed with the Pierre Auger Observatory, upper limits of 3.8%, 2.4%, 3.5% and 11.7% (at 95% c.l.) are obtained on the fraction of cosmic-ray photons above 2, 3, 5 and 10 EeV (1 EeV equivalent to 10(18) eV), respectively. These are the first experimental limits on ultra-high energy photons at energies below 10 EeV. The results complement previous constraints on top-down models from array data and they reduce systematic uncertainties in the interpretation of shower data in terms of primary flux, nuclear composition and proton-air cross-section. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
The distribution network reliability can be increased if distributed generators (DGs) are allowed to operate in both grid-connected and islanded operations when the network has a high DG penetration level. However, the current utility regulations do not allow for the islanded operation. The arc faults are the one of the major issues preventing the islanded operation, since the arc will not extinguish if the DGs are not disconnected. In this paper, the effect of a converter interfaced DG on an arc fault is investigated by considering different control strategies for the converter. The foldback current control characteristic is proposed to a converter interfaced DG to achieve quick arc extinction and self-restoration without disconnecting the DG in the event of an arc fault. The results are validated through PSCAD/EMTDC simulations.
Resumo:
Our students come from diverse backgrounds. They need flexibility in their learning. First year students tend to worry when they miss lectures or part of lectures. Having the lecture as an on line resource allows students to miss a lecture without stressing about it and to be more relaxed in the lecture, knowing that anything they may miss will be available later. The resource: The Windows based program from Blueberry Software (not Blackberry!) - BB Flashback - allows the simultaneous recording of the computer screen together with the audio, as well as Webcam recording. Editing capabilities include adding pause buttons, graphics and text to the file before exporting it in a flash file. Any diagrams drawn on the board or shown via visualiser can be photographed and easily incorporated. The audio from the file can be extracted if required to be posted as podcast. Exporting modes other than Flash are also available, allowing vodcasting if you wish. What you will need: - the recording software: it can be installed on the lecture hall computer just prior to lecture if needed - a computer: either the ones in lecture halls, especially if fitted with audio recording, or a laptop (I have used audio recording via Bluetooth for mobility). Feedback from students has been positive and will be presented on the poster.