992 resultados para Antigen detection


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Immunohistochemistry reaction (Peroxidase anti-peroxidase - PAP) was carried out on fifty-two skin biopsies from leprosy patients with the purpose to identify the antigenic pattern in mycobacteria and to study the sensitivity of this method. Five different patterns were found: bacillar, granular, vesicular, cytoplasmatic and deposits, classified according to the antigenic material characteristics. Deposits (thinely particulate material) appeared more frequently, confirming the immunohistochemistry sensitivity to detect small amounts of antigens even when this material is not detected by histochemical stainings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Eighty purulent cerebrospinal fluid (CSF) samples from patients with clinical evidence of meningitis were studied using the Directigen latex agglutination (LA) kit to determine the presence of bacterial antigen in CSF. The results showed a better diagnostic performance of the LA test than bacterioscopy by Gram stain, culture and counterimmunoelectrophoresis (CIE), as far as Neisseria meningitidis groups B and C, and Haemophilus influenzae type b are concerned, and a better performance than bacterioscopy and culture considering Streptococcus pneumoniae. Comparison of the results with those of culture showed that the LA test had the highest sensitivity for the Neisseria meningitidis group C. Comparing the results with those of CIE, the highest levels of sensitivity were detected for N. meningitidis groups B and C. Regarding specificity, fair values were obtained for all organisms tested. The degree of K agreement when the LA test was compared with CIE exhibited better K indices of agreement for N. meningitidis groups B and C.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Adenovirus (AdV) respiratory infections are usually described as being associated with high mortality rates. Laboratory diagnosis is essential for the establishment of the appropriate therapy, and for guiding the implementation of preventive measures in order to prevent the spread of the infection. Aiming to analyze the sensitivity and specificity of the laboratorial diagnosis methods available, we compared antigen detection by indirect immunofluorescence assay (IF), and a specific nested polymerase chain reaction (PCR), to detect AdV in respiratory samples collected from patients admitted to hospital with acute respiratory disease. Positive samples were inoculated into a cell culture to confirm the results. We analyzed 381 samples from the nasopharyngeal aspirates collected during the year 2008; of these, 2.6% tested were positive for adenovirus through IF and 10% through PCR; positive isolation was obtained in 40% and 26% of these cases, respectively. Most infected patients were children under six months of age, and despite of the fact that a significant number of patients required intensive care, the mortality rate was low (5%). In conclusion, molecular methods were found to be useful for rapid diagnosis of adenovirus infections with higher sensitivity than antigen detection; their introduction permitted a significant increase in diagnoses of adenovirus infections.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present work evaluated the diagnostic accuracy of detection of Dengue NS1 antigen employing two NS1 assays, an immunochromatographic assay and ELISA, in the diagnostic routine of Public Health laboratories. The results obtained with NS1 assay were compared with virus isolation and, in a subpopulation of cases, they were compared with the IgM-ELISA results obtained with convalescent samples. A total of 2,321 sera samples were analyzed by one of two NS1 techniques from March to October 2009. The samples were divided into five groups: groups I, II and III included samples tested by NS1 and virus isolation, and groups IV and V included patients with a first sample tested by NS1 and a second sample tested by IgM-ELISA. Sensitivity, specificity, positive and negative predictive values, Kappa Index and Kappa Concordance were calculated. The results showed that NS1 testing in groups I, II and III had high sensitivity (98.0%, 99.5% and 99.3%), and predictive values and Kappa index between 0.9 - 1.0. Groups IV and V only had Kappa Concordance calculated, since the samples were analyzed according to the presence of NS1 antigen or IgM antibody. Concordance of 92.1% was observed when comparing the results of NS1-negative samples with IgM-ELISA. Based on the findings, it is possible to suggest that the tests for NS1 detection may be important tools for monitoring the introduction and spread of Dengue serotypes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the impact of the routine use of rapid antigen detection test in the diagnosis and treatment of acute pharyngotonsillitis in children. METHODS: This is a prospective and observational study, with a protocol compliance design established at the Emergency Unit of the University Hospital of Universidade de São Paulo for the care of children and adolescents diagnosed with acute pharyngitis. RESULTS: 650 children and adolescents were enrolled. Based on clinical findings, antibiotics would be prescribed for 389 patients (59.8%); using the rapid antigen detection test, they were prescribed for 286 patients (44.0%). Among the 261 children who would not have received antibiotics based on the clinical evaluation, 111 (42.5%) had positive rapid antigen detection test. The diagnosis based only on clinical evaluation showed 61.1% sensitivity, 47.7% specificity, 44.9% positive predictive value, and 57.5% negative predictive value. CONCLUSIONS: The clinical diagnosis of streptococcal pharyngotonsillitis had low sensitivity and specificity. The routine use of rapid antigen detection test led to the reduction of antibiotic use and the identification of a risk group for complications of streptococcal infection, since 42.5% positive rapid antigen detection test patients would not have received antibiotics based only on clinical diagnosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Detection of HIV-1 p24 antigen permits early identification of primary HIV infection and timely intervention to limit further spread of the infection. Principally, HIV screening should equally detect all viral variants, but reagents for a standardised test evaluation are limited. Therefore, we aimed to create an inexhaustible panel of diverse HIV-1 p24 antigens. METHODS We generated a panel of 43 recombinantly expressed virus-like particles (VLPs), containing the structural Gag proteins of HIV-1 subtypes A-H and circulating recombinant forms (CRF) CRF01_AE, CRF02_AG, CRF12_BF, CRF20_BG and group O. Eleven 4th generation antigen/antibody tests and five antigen-only tests were evaluated for their ability to detect VLPs diluted in human plasma to p24 concentrations equivalent to 50, 10 and 2 IU/ml of the WHO p24 standard. Three tests were also evaluated for their ability to detect p24 after heat-denaturation for immune-complex disruption, a pre-requisite for ultrasensitive p24 detection. RESULTS Our VLP panel exhibited an average intra-clade p24 diversity of 6.7%. Among the 4th generation tests, the Abbott Architect and Siemens Enzygnost Integral 4 had the highest sensitivity of 97.7% and 93%, respectively. Alere Determine Combo and BioRad Access were least sensitive with 10.1% and 40.3%, respectively. Antigen-only tests were slightly more sensitive than combination tests. Almost all tests detected the WHO HIV-1 p24 standard at a concentration of 2 IU/ml, but their ability to detect this input for different subtypes varied greatly. Heat-treatment lowered overall detectability of HIV-1 p24 in two of the three tests, but only few VLPs had a more than 3-fold loss in p24 detection. CONCLUSIONS The HIV-1 Gag subtype panel has a broad diversity and proved useful for a standardised evaluation of the detection limit and breadth of subtype detection of p24 antigen-detecting tests. Several tests exhibited problems, particularly with non-B subtypes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe an adaptation of the rolling circle amplification (RCA) reporter system for the detection of protein Ags, termed “immunoRCA.” In immunoRCA, an oligonucleotide primer is covalently attached to an Ab; thus, in the presence of circular DNA, DNA polymerase, and nucleotides, amplification results in a long DNA molecule containing hundreds of copies of the circular DNA sequence that remain attached to the Ab and that can be detected in a variety of ways. Using immunoRCA, analytes were detected at sensitivities exceeding those of conventional enzyme immunoassays in ELISA and microparticle formats. The signal amplification afforded by immunoRCA also enabled immunoassays to be carried out in microspot and microarray formats with exquisite sensitivity. When Ags are present at concentrations down to fM levels, specifically bound Abs can be scored by counting discrete fluorescent signals arising from individual Ag–Ab complexes. Multiplex immunoRCA also was demonstrated by accurately quantifying Ags mixed in different ratios in a two-color, single-molecule-counting assay on a glass slide. ImmunoRCA thus combines high sensitivity and a very wide dynamic range with an unprecedented capability for single molecule detection. This Ag-detection method is of general applicability and is extendable to multiplexed immunoassays that employ a battery of different Abs, each labeled with a unique oligonucleotide primer, that can be discriminated by a color-coded visualization system. ImmunoRCA-profiling based on the simultaneous quantitation of multiple Ags should expand the power of immunoassays by exploiting the increased information content of ratio-based expression analysis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Serum samples from 242 HIV-positive persons were studied for the detection of capsular polysaccha-ride antigen of Cryptococcus neoformans; 193 of these patients presented less than 300 CD4+ cells/µl of blood and 49 patients had more than 300 CD4+ cells/µl. None of them had symptoms or signs characteristic of cryptococcosis. The capsular antigen of C. neofarmans was detected by latex agglutination technique with pronase pre-treatment (IMMY, Crypto-Latex Antigen Detection System, Immunomycologics Inc., OK, USA); in 61% of the samples, ELISA technique was also used (Premier, Cryptococcal Antigen, Meridian Diagnostic Inc., Cincinatti, Oh, USA). The comparative study of both methods showed that the results obtained were similar in 96.9% of the cases. The capsular antigen was detected in 13 out of 193 (6.7%) patients with less than 300 CD4+ cells/µl. Cryptococcosis was confirmed mycologically in 3 of these 13 cases (23%) by the isolation of C. neoformans in CSF or blood cultures. Three patients, who had presented negative results of both tests for capsular antigen, suffered disseminated cryptococcosis 4 to 8 months later. The predictive diagnostic value of capsular antigen detection of C. neoformans seems tobe low and we believe that it should not be done routinely in asymptomatic HIV-positive persons.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An enzyme-linked immunosorbent assay was standardized for the detection of cryptococcal antigen in serum and cerebrospinal fluid. The system was evaluated in clinical samples from patients infected by human immunodeficiency virus with and without previous cryptococcosis diagnosis. The evaluated system is highly sensitive and specific, and when it was compared with latex agglutination there were not significant differences. A standard curve with purified Cryptococcus neoformans antigen was settled down for the antigen quantification in positive samples.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present study developed and standardized an enzime-linked immunosorbent assay (ELISA) to detect Giardia antigen in feces using rabbit polyclonal antibodies. Giardia cysts were purified from human fecal samples by sucrose and percoll gradients. Gerbils (Meriones unguiculatus) were infected to obtain trophozoites. Rabbits were inoculated with either cyst or trophozoite antigens of 14 Colombian Giardia isolates to develop antibodies against the respective stages. The IgG anti-Giardia were purified by sequential caprylic acid and ammonium sulfate precipitation. A portion of these polyclonal antibodies was linked to alkaline phosphatase (conjugate). One hundred and ninety six samples of human feces, from different patients, were tested by parasitologic diagnosis: 69 were positive for Giardia cysts, 56 had no Giardia parasites, and 71 revealed parasites other than Giardia. The optimal concentration of polyclonal antibodies for antigen capture was 40 µg/ml and the optimal conjugate dilution was 1:100. The absorbance cut-off value was 0.24. The parameters of the ELISA test for Giardia antigen detection were: sensitivity, 100% (95% CI: 93.4-100%); specificity, 95% (95% CI: 88.6-97.6%); positive predictive value, 91% (95% CI: 81.4-95.9%); and negative predictive value, 100% (95% CI: 96.1-100%). This ELISA will improve the diagnosis of Giardia infections in Colombia and will be useful in following patients after treatment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Detection of cryptococcal antigen in serum or cerebrospinal fluid allows cryptococcal meningitis diagnosis within few hours with >90% sensitivity. In an HIV-positive patient with Cryptococcus neoformans meningitis, initial antigen detection by immunoagglutination was negative. We thus evaluated a new immunochromatographic detection assay that exhibited a higher sensitivity.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

For the diagnosis and follow-up of paracoccidioidomycosis patients undergoing therapy, we evaluated two methods (immunoblotting and competition enzyme immunoassay) for the detection of circulating antigen in urine samples. A complex pattern of reactivity was observed in the immunoblot test. Bands of 70 and 43 kDa were detected more often in urine samples from patients before treatment. The immunoblot method detected gp43 and gp70 separately or concurrently in 11 (91.7%) of 12 patients, whereas the competition enzyme immunoassay detected antigenuria in 9 (75%) of 12 patients. Both tests appeared to be highly specific (100%), considering that neither fraction detectable by immunoblotting was present in urine samples from the control group. gp43 remained present in the urine samples collected during the treatment period, with a significant decrease in reactivity in samples collected during clinical recovery and increased reactivity in samples collected during relapses. Reactivity of some bands was also detected in urine specimens from patients with 'apparent cure.' The detection of Paracoccidioides brasiliensis antigens in urine appears to be a promising method for diagnosing infection, for evaluating the efficacy of treatment, and for detecting relapse.