1000 resultados para Anti-aliasing filter
Resumo:
The present study proposes to apply magnitude-squared coherence (MSC) to the somatosensory evoked potential for identifying the maximum driving response band. EEG signals, leads [Fpz'-Cz'] and [C3'-C4'], were collected from two groups of normal volunteers, stimulated at the rate of 4.91 (G1: 26 volunteers) and 5.13 Hz (G2: 18 volunteers). About 1400 stimuli were applied to the right tibial nerve at the motor threshold level. After applying the anti-aliasing filter, the signals were digitized and then further low-pass filtered (200 Hz, 6th order Butterworth and zero-phase). Based on the rejection of the null hypothesis of response absence (MSC(f) > 0.0060 with 500 epochs and the level of significance set at a = 0.05), the beta and gamma bands, 15-66 Hz, were identified as the maximum driving response band. Taking both leads together ("logical-OR detector", with a false-alarm rate of a = 0.05, and hence a = 0.0253 for each derivation), the detection exceeded 70% for all multiples of the stimulation frequency within this range. Similar performance was achieved for MSC of both leads but at 15, 25, 35, and 40 Hz. Moreover, the response was detected in [C3'-C4'] at 35.9 Hz and in [Fpz'-Cz'] at 46.2 Hz for all members of G2. Using the "logical-OR detector" procedure, the response was detected at the 7th multiple of the stimulation frequency for the series as a whole (considering both groups). Based on these findings, the MSC technique may be used for monitoring purposes.
Resumo:
The commercial data acquisition systems used for seismic exploration are usually expensive equipment. In this work, a low cost data acquisition system (Geophonino) has been developed for recording seismic signals from a vertical geophone. The signal goes first through an instrumentation amplifier, INA155, which is suitable for low amplitude signals like the seismic noise, and an anti-aliasing filter based on the MAX7404 switched-capacitor filter. After that, the amplified and filtered signal is digitized and processed by Arduino Due and registered in an SD memory card. Geophonino is configured for continuous registering, where the sampling frequency, the amplitude gain and the registering time are user-defined. The complete prototype is an open source and open hardware system. It has been tested by comparing the registered signals with the ones obtained through different commercial data recording systems and different kind of geophones. The obtained results show good correlation between the tested measurements, presenting Geophonino as a low-cost alternative system for seismic data recording.
Resumo:
Le flou de mouvement de haute qualité est un effet de plus en plus important en rendu interactif. Avec l'augmentation constante en qualité des ressources et en fidélité des scènes vient un désir semblable pour des effets lenticulaires plus détaillés et réalistes. Cependant, même dans le contexte du rendu hors-ligne, le flou de mouvement est souvent approximé à l'aide d'un post-traitement. Les algorithmes de post-traitement pour le flou de mouvement ont fait des pas de géant au niveau de la qualité visuelle, générant des résultats plausibles tout en conservant un niveau de performance interactif. Néanmoins, des artefacts persistent en présence, par exemple, de mouvements superposés ou de motifs de mouvement à très large ou très fine échelle, ainsi qu'en présence de mouvement à la fois linéaire et rotationnel. De plus, des mouvements d'amplitude importante ont tendance à causer des artefacts évidents aux bordures d'objets ou d'image. Ce mémoire présente une technique qui résout ces artefacts avec un échantillonnage plus robuste et un système de filtrage qui échantillonne selon deux directions qui sont dynamiquement et automatiquement sélectionnées pour donner l'image la plus précise possible. Ces modifications entraînent un coût en performance somme toute mineur comparativement aux implantations existantes: nous pouvons générer un flou de mouvement plausible et temporellement cohérent pour plusieurs séquences d'animation complexes, le tout en moins de 2ms à une résolution de 1280 x 720. De plus, notre filtre est conçu pour s'intégrer facilement avec des filtres post-traitement d'anticrénelage.
Resumo:
Neste trabalho, foi aplicado o processamento de imagens digitais auxiliado pelas Redes Neurais Artificiais (RNA) com a finalidade de identificar algumas variedades de soja por meio da forma e do tamanho das sementes. Foram analisadas as seguintes variedades: EMBRAPA 133, EMBRAPA 184, COODETEC 205, COODETEC 206, EMBRAPA 48, SYNGENTA 8350, FEPAGRO 10 e MONSOY 8000 RR, safra 2005/2006. O processamento das imagens foi constituído pelas seguintes etapas: 1) Aquisição da imagem: as amostras de cada variedade foram fotografadas por máquina fotográfica Coolpix995, Nikon, com resolução de 3.34 megapixels; 2) Pré-processamento: um filtro de anti-aliasing foi aplicado para obter tons acinzentados da imagem; 3) Segmentação: foi realizada a detecção das bordas das sementes (Método de Prewitt), dilatação dessas bordas e remoção de segmentos não-necessários para a análise. 4) Representação: cada semente foi representada na forma de matriz binária 130x130, e 5) Reconhecimento e interpretação: foi utilizada uma rede neural feedforward multicamadas, com três camadas ocultas. O treinamento da rede foi realizado pelo método backpropagation. A validação da RNA treinada mostrou que o processamento aplicado pode ser usado para a identificação das variedades consideradas.
Resumo:
The authors studied 70 leprosy patients and 20 normal individuals, comparing the traditional sera collection method and the finger prick blood with the conservation on filter paper for specific antibodies against the native phenolic glycolipid-I (PGL-I) from Mycobacterium leprae. The finger prick blood dried on filter paper was eluated in phosphate buffer saline (PBS) containing 0.5% gelatin. The classical method for native PGL-I was performed for these eluates, and compared with the antibody determination for sera. It was observed that there is a straight correlation comparing these two methods; although the titles found for the eluates were lower than those obtained for serology. This blood collection method could be useful for investigation of new leprosy cases in field, specially in contacts individuals.
Resumo:
We describe here a method, based on iterative colony filter screening, for the rapid isolation of binding specificities from a large synthetic repertoire of human antibody fragments in single-chain Fv configuration. Escherichia coli cells, expressing the library of antibody fragments, are grown on a porous master filter, in contact with a second filter coated with the antigen, onto which antibodies secreted by the bacteria are able to diffuse. Detection of antigen binding on the second filter allows the recovery of a number of E.coli cells, including those expressing the binding specificity of interest, which can be submitted to a second round of screening for the isolation of specific monoclonal antibodies. We tested the methodology using as antigen the ED-B domain of fibronectin, a marker of angiogenesis. From an antibody library of 7 × 108 clones, we recovered a number of specifically-binding antibodies of different aminoacid sequence. The antibody clone showing the strongest enzyme-linked immunosorbent assay signal (ME4C) was further characterised. Its epitope on the ED-B domain was mapped using the SPOT synthesis method, which uses a set of decapeptides spanning the antigen sequence synthesised and anchored on cellulose. ME4C binds to the ED-B domain with a dissociation constant Kd = 1 × 10–7 M and specifically stains tumour blood vessels, as shown by immunohistochemical analysis on tumour sections of human and murine origin.
Resumo:
Some Latin American countries have plans for total control and/or eradication of Chagas disease by the main vector (Triatoma infestans) and by blood transfusion. To achieve this, patients with Chagas disease must be identified. A Western blotting test, TESAcruzi, is described as a supplemental test for diagnosis of Chagas disease using samples collected from children <5 years living in different states of Brazil. Blood samples collected by finger prick on filter paper were sent to the test laboratory by a central laboratory to confirm results obtained previously. Ten percent of negative samples, all doubtful and all positive samples were received. Commercial reagents, IgG indirect immunofluorescence, enzyme immunoassay, and a recently introduced TESAcruzi test were used. From 8788 samples, 163 (1.85%) were reactive by IgG-ELISA and 312 (3.55%) by IgG IIF. From these, 77 (0.87%) were reactive in the TESAcruzi test. The results had high clinical value to identify those truly infected. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
OBJETIVES: To detect anti-Giardia lamblia serum antibodies in healthy children attending public day care centers and to assess serological tests as tools for estimating the prevalence of G. lamblia in endemic areas. METHODS: Three separate stool specimens and filter paper blood samples were collected from 147 children ranging from 0 to 6 years old. Each stool sample was processed using spontaneous sedimentation and zinc sulfate flotation methods. Blood samples were tested by indirect immunofluorescence (IIF) and enzyme-linked immunosorbent assay (ELISA) for Giardia IgG. RESULTS AND CONCLUSIONS: Of 147 individuals tested, 93 (63.3%) showed Giardia cysts in their feces. Using IIF and ELISA, serum antibodies were detected in 93 (63.3%) and 100 (68%) samples , respectively. Sensitivity of IIF and ELISA was 82% and 72%, respectively. However, ELISA revealed to be less specific (39%) than IIF (70%). IIF also showed a higher concordance with microscopic examination than ELISA.
Resumo:
This report describes the prevalence of anti-HAV antibodies in children from elementary school in the Municipality of Vila Velha, ES, Brazil. Anti-HAV antibodies were investigated by ELISA method in the serum of 606 children (four to fourteen years old) from three elementary schools, located in neighborhoods with varying household monthly income levels: São José School, 200 chidren, household income higher than US$700; São Torquato School, 273 children, US$200 to 300; and Cobi School, 133 children, less than US$200. From each children data on age, gender, skin color, sanitary conditions, frequency of contact with sea or river water and family history of hepatitis were recorded. Anti-HAV antibodies were present in 38.6% of all children, 9% in São José School, 49.1% in São Torquato School and 61.7% in Cobi School. Logistic regression analysis demonstrated a positive correlation of positive anti-HAV test with age, non white color of the skin, absence of sewage treatment and domestic water filter, and a past history of hepatitis. The prevalence of anti-HAV antibodies in school children in Vila Velha, ES, was lower than that observed in the same age group in North and Northeast Brazil and was significantly higher in children from families with low socioeconomic status. In addition the results indicate a changing epidemiologic pattern of hepatitis A in our country, with an increasing number of children and adolescents with high risk for HAV infection, mainly in high socioeconomic class. A consideration must be given to the feasibility of vaccination programs for children and adolescents in our country.
Resumo:
This study evaluates whether blood collected on filter paper kept at 4 degrees C and tested at different intervals of time (1, 7, 15, 30 and 60 days after collection) would present similar results when compared to the serum samples and whether the type of filter paper influences the results. Eluates from filter paper samples were tested for Trypanosoma cruzi antibodies using indirect immunofluorescence antibody test (IFAT), indirect haemagglutination (IHA) and enzyme-linked immunosorbent assay (ELISA) as reference, the antibody titer in sera. Analysis of data showed that results obtained with IFAT, IHA (cut off point = 1:40) and ELISA in sera had similar sensitivity and good concordance among reactions. The use of a multiple linear regression model indicated that titer fall in eluates occurs up to the 7th day after the collection, and it is more marked for samples with lower antibodies titers. However, no significant differences were observed by IFAT, IHA (cut off point = 1:20) and ELISA in the proportion of positive reactions between sera and eluates. The results also showed that Melitta, Klabin or Whatman (reference) filter papers could be indicated for surveys, since they have shown similar capacity of maintenance of anti-T. cruzi immunoglobulins.
Resumo:
Coherent anti-Stokes Raman scattering (CARS) microscopy is rapidly developing into a unique microscopic tool in biophysics, biology and the material sciences. The nonlinear nature of CARS spectroscopy complicates the analysis of the received spectra. There were developed mathematical methods for signal processing and for calculations spectra. Fourier self-deconvolution is a special high pass FFT filter which synthetically narrows the effective trace bandwidth features. As Fourier self-deconvolution can effectively reduce the noise, which may be at a higher spatial frequency than the peaks, without losing peak resolution. The idea of the work is to experiment the possibility of using wavelet decomposition in spectroscopic for background and noise removal, and Fourier transformation for linenarrowing.
Resumo:
F1-antigen purified from Yersinia pestis was covalently linked to 5-mm diameter filter paper discs plasticized with polyvinyl alcohol-glutaraldehyde. These discs were used both for ELISA and dot-ELISA for the detection of anti-F1 IgG in rabbits. The best conditions were achieved using 1.25 µg of F1 antigen/disc, 3% w/v skim milk in PBS as blocking agent, anti-IgG peroxidase conjugate diluted 12,000 times, and serum from rabbits immunized or not against Y. pestis, diluted 6,400 times. The absorbance values obtained from the comparative study between this procedure and conventional ELISA were not significantly different but the low cost of the reagents employed in ELISA using the filter paper discs plasticized with polyvinyl alcohol-glutaraldehyde makes this method economically attractive.
Resumo:
Oil well cementing materials consist of slurries of Special class Portland cement dispersed in water. Admixtures can be used to provide the necessary fluidity, so the material can be efficiently pumped down as well as penetrate porous rocks with controlled filter loss. Construction admixtures can be used to modify the properties of oil well cements provided they can withstand and hold their properties at the higher than ambient temperatures usually encountered in oil fields. In civil construction, superplasticizer play the role of dispersants that reduce the facto r of water cement improve mechanical properties and fluidity of the cement, whereas anti-segregation agents improve the workability of the slurry. In the present study, oil well cement slurries were produced adding both a dispersant and an anti-segregation agent conventionally used in Portland CPII-Z-32 RS cement aiming at materials for primary cementing and squeeze operations. Three basic aspects were evaluated: fluidity, filter loss and the synergetic effect of the admixtures at two temperatures, i.e., 27°C and 56°C, following API RP 10B practical recommendations. The slurries were prepared using admixture concentrations varying from 2.60 Kgf/m3 (0.02 gallft3) to 5.82 Kgf/m3 (0.045 galJft3) BWOC. The density of the slurries was set to 1.89 g/cm3 (15.8 Ib/gal). 0.30 to 0.60% BWOC of a CMC-based anti-segregation agent was added to the cement to control the filter loss. The results showed that the addition of anti-segregation at concentrations above 0.55% by weight of cement resulted in the increased viscosity of the folders in temperatures evaluated. The increasing the temperature of the tests led to a reduction in the performance of anti-segregation. At concentrations of 5.20 kgf/m3 (0,040 gallft3) and 5.82 Kgf/m3 (0,045 gal/ft 3) observed a better performance of the properties evaluated in the proposed system. At low temperature was observed instability in the readings of rheology for all concentrations of anti-segregation. Contents that increasing the concentration of anti¬-segregation is limited concentrations greater than 0.55 % BWOC of the CMC in temperature analyzed. The use of the system with CMC promoted a good performance against the properties evaluated. The principal function of anti¬-segregation was optimized with increasing concentration of superplasticizer, at temperatures above the 2rC. The study of the behaviour of systemic additives, resulting in slurries of cement, which can be optimized face studies of other intrinsic properties in oil fields
Resumo:
This paper investigates a novel design approach for a vibration isolator for use in space structures. The approach used can particularly be applicable for aerospace structures that support high precision instrumentation such as satellite payloads. The isolator is a space-frame structure that is folded in on itself to act as a mechanical filter over a defined frequency range. The absence of viscoelastic elements in such a mounting makes the design suitable for use in a vacuum and in high temperature or harsh environments with no risk of drift in alignment of the structure. The design uses a genetic algorithm based geometric optimisation routine to maximise passive vibration isolation, and this is hybridised with a geometric feasibility search. To complement the passive isolation system, an active system is incorporated in the design to add damping. Experimental work to validate the feasibility of the approach is also presented, with the active/passive structure achieving transmissibility of about 19 dB over a range of 1-250 Hz. It is shown here that the use of these novel anti-vibration mountings has no or little consequent weight and cost penalties whilst maintaining their effectiveness with the vibration levels. The approach should pave the way for the design of anti-vibration mountings that can be used between most pieces of equipment and their supporting structure. Crown Copyright (C) 2011 Published by Elsevier Ltd. All rights reserved.
Resumo:
OBJETIVOS: Detectar anticorpos séricos anti-Giardia lamblia entre crianças atendidas em creches e estimar a freqüência de infecção por Giardia lamblia em área endêmica. MÉTODOS: Foram coletadas três amostras de fezes de cada uma das 147 crianças de três creches da rede municipal de Botucatu, SP, com idade variando de 0 a 6 anos, e as amostras foram processadas pelos métodos de sedimentação espontânea e flutuação pelo sulfato de zinco. Amostras de sangue foram obtidas da polpa digital, coletadas em papel de filtro e testadas pelos métodos de imunofluorescência indireta (IFI) e de reação imunoenzimática (Elisa) para pesquisa de IgG anti-Giardia. RESULTADOS E CONCLUSÕES: de um total de 147 crianças, 93 (63,3%) apresentaram cistos de Giardia nas fezes. Dos 147 eluatos testados, 93 (63,3%) e 100 (68%) foram positivos para Giardia em IFI e em Elisa, respectivamente. A sensibilidade de IFI foi de 82% e de Elisa, 72%. Contudo, Elisa foi menos específica (39%) do que IFI (70%). A imunofluorescência indireta apresentou maior concordância com o exame de fezes do que Elisa.