992 resultados para Anesthesia in dentistry


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Context:Most child population is able to undergo dental treatment in the conventional setting. However, some children fail to cope with in-office conscious state and cannot respond to usual management modalities. This review aims to discuss the topic further. Evidence Acquisition: A computerized search in databases PubMed, MEDLINE, EMBASE, Google Scholar and Google were performed using dental general anesthesia related keywords. Original and review English-written articles that were limited to child population were retrieved without any limitation of publication date. The suitable papers were selected and carefully studied. A data form designed by author was used to write relevant findings. Results: Preoperative oral examination and comprehensive evaluation of treatment needs is only possible after clinical and radiographic oral examination. Effective collaboration in dental GA team should be made to minimize psychological trauma of children who undergo dental GA. Before conducting comprehensive dental treatment under GA, the general health of the child and the success rate of procedures provided needs to be accurately evaluated. It is noteworthy that determination of the optimal timing for GA dental operation is of great importance. Providing safety with pediatric dental rehabilitation under GA is critical. Conclusions: Besides criteria for case selection of dental GA, some degree of dental practitioner’s judgment is required to make decision. Pre- and post-operative instructions to parents or caregiver decrease the risk of complications. However, trained resuscitation providers, careful monitoring and advanced equipment minimize adverse outcomes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sousa FAEF, Colhado OCG - Lumbar Epidural Anesthesia in the Treatment of Discal Lombosciatalgia: A Comparative Clinical Study between Methylprednisolone and Methylprednisolone with Levobupivacaine. Background and objectives: Lumbar epidural technique has been used in the treatment of lombosciatalgia since 1953. In most cases, methylprednisolone is used along with a local anesthetic, and it is not known whether the isolated use of methylprednisolone is equally effective in relieving symptoms. The objective of this study was to compare the efficacy of two different solutions - methylprednisolone with saline and methylprednisolone with levobupivacaine injected in the epidural space to heal lombosciatalgia secondary to lumbar herniated disk. Methods: Sixty individuals ASA I and II, of both genders, ages 18 to 65 years participated in this randomized, double-blind study over a period of one year. They underwent interlaminar lumbar epidural analgesia without radioscopic control to heal a lombosciatalgia and they were divided into two groups: G-M (methylprednisolone + saline) and G-M + L (methylprednisolone + levobupivacaine + saline) both at a volume of 10 mL. Diagnosis was based on history, physical exam, and imaging exam (MRI). The Visual Analogue Scale (VAS) was applied in a total of two blockades, 15 days apart. Results: A reduction in pain severity was observed in the methylprednisolone-levobupivacaine group, but without statistical significance. Conclusions: The analgesic efficacy of the G-M + L solution was superior to that of the G-M solution in the treatment of discal lombosciatalgia regarding the shorter time to onset of analgesia, but this was not significant at the time of discharge, and both solutions were effective in the treatment of discal lombosciatalgia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aliman AC, Piccioni MA, Piccioni JL, Oliva JL, Auler Junior JOC - Intraosseous Anesthesia in Hemodynamic Studies in Children with Cardiopathy. Background and objectives: Intraosseous (IO) access has been used with good results in emergency situations, when venous access is not available for fluids and drugs infusion. The objective of this study was to evaluate IO a useful technique for anesthesia and fluids infusion during hemodynamic studies and when peripheral intravascular access is unobtainable. The setting was an university hospital hemodynamics unit, and the subjects were twenty one infants with congenital heart disease enrolled for elective hemodynamic study diagnosis. Methods: This study compared the effectiveness of IO access in relation to IV access for infusion of anesthetics agents (ketamine, midazolann, and fentanyl) and fluids during hemodynamic studies. The anesthetic induction time, procedure duration, anesthesia recovery time, adequate hydration, and IV and IO puncture complications were compared between groups. Results: The puncture time was significantly smaller in IO group (3.6 min) that in IV group (9.6 min). The anesthetic onset time (56.3 second) for the IV group was faster than IO group (71.3 second). No significant difference between groups were found in relation to hydration (IV group, 315.5 mL vs IO group, 293.2 mL), and anesthesia recovery time (IO group, 65.2 min vs IV group, 55.0 min). The puncture site was reevaluated after 7 and 15 days without signs of infection or other complications. Conclusions: Results showed superiority for IO infusion when considering the puncture time of the procedure. Due to its easy manipulation and efficiency, hydration and anesthesia by IO access was satisfactory for hemodynamic studies without the necessity of other infusion access.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To evaluate the extent sensory and motor blocks produced by the epidural injection of different volumes of 0.25% bupivacaine (Bu) with methylene blue (MB), in dogs. Study design Prospective experimental trial. Animals Twenty healthy adult mongrel dogs, weighing 9.9 +/- 1.9 kg. Methods Dogs were randomly allocated into one of four groups that received 0.2, 0.4, 0.6 or 0.8 mL kg-1 of an epidural solution containing 0.25% Bu and MB. Sensory block was evaluated against time by pinching the tail, hind limb interdigital web, toenail bases and the skin over the vertebral dermatomes. Motor block was assessed by ataxia, hind limb weight-bearing ability and by loss of muscle tone of the tail and pelvic limbs. Data were collected at 2, 5, 10, 15 and 30 minutes after the end of epidural injection. After the final time point, dogs were euthanatized and laminectomies were conducted to expose the extent of the dural dye staining. Results The volumes 0.2, 0.4, 0.6 and 0.8 mL kg-1 of 0.25% Bu and MB blocked a mean of 5, 14.2, 20.2 and 21 dermatomes, respectively. The extent of the senory block increased up to a volume of 0.6 mL kg-1. Motor block was longer-lasting and more intense than sensory block. Complete dyeing of the spinal cord with MB was achieved in some dogs at 0.4 mL kg-1 and all dogs at 0.6 mL kg-1. Conclusions The volume of anesthetic injected into the epidural space plays an important role in the quality of the epidural anesthesia. At 0.25%, bupivacaine provided an efficient sensory block at 0.6 mL kg-1. Clinical relevance Relatively high volumes (0.6 mL kg-1) of 0.25%, BU and MB were needed to produce an effective sensory and motor block caudal to the umbilicus, but all spinal cord segments were reached by MB at this dose.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To compare the quality of induction and recovery, degree of muscle relaxation, clinically apparent potency and cardiopulmonary effects of racemic ketamine or S(+)-ketamine when used for total intravenous anesthesia in horses. Study design Prospective randomized clinical trial Animals Sixteen healthy stallions (323 +/- 99 kg), with a mean age of 6.2 years, undergoing castration. Methods Horses were pre-medicated with romifidine IV, 15 minutes before induction of anesthesia. Each animal was then randomly allocated to receive either diazepam and ketamine (DK) or diazepam and S(+)-ketamine (DKS) at similar doses to induce anesthesia. For maintenance of anesthesia, 1/4 of the initial bolus of ketamine alone or S(+)-ketamine alone was administered, as required. Heart rate (HR), respiratory rate (RR) and systolic blood pressure were measured before and at 10-minute intervals during recumbency. Time from induction to lateral recumbency, time from induction to first additional dose, time from last additional dose to return to sternal posture and time from last additional dose to standing were recorded, and a subjective evaluation of quality of induction, endotracheal intubation, muscle relaxation and quality of recovery was recorded. Results The quality of the induction and duration of anesthesia were similar in both groups. HR, RR and systolic blood pressure were not significantly different between groups. Although some animals which received DKS showed some minor excitatory effects (25% of them) during the induction of anesthesia, these animals received 32% fewer doses for the maintenance of anesthesia and the recovery scores were better. Conclusions and clinical relevance S(+)-ketamine showed some advantages over racemic ketamine, such as less anesthetic agent being required and better overall recovery from anesthesia. Further studies are needed to obtain the optimum induction dose for the S(+)-ketamine.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Distraction osteogenesis is a technique for induction of new bone formation between two segments of a bone that presents wide possibilities of use in Dentistry. However, the available information on this subject is still scarce. The aim of this article is to review the literature related to bone formation, mechanically induced by distraction osteogenesis, in order to supply subsidies the agreement of this process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A range of lasers. is now available for use in dentistry. This paper summarizes key current and emerging applications, for lasers in clinical practice. A major diagnostic application of low power lasers is the detection of caries, using fluorescence elicited from hydroxyapatite or from bacterial by-products. Laser fluorescence is an effective method for detecting and quantifying incipient occlusal and cervical,carious lesions, and with further refinement could be used in the, same manner for proximal lesions. Photoactivated dye techniques have been developed which use low power lasers to elicit a photochemical reaction, Photoactivated dye techniques' can be used to disinfect root canals, periodontal pockets, cavity preparations and sites of peri-implantitis. Using similar principles, more powerful lasers tan be used for photodynamic therapy in the treatment of malignancies of the oral mucosa. Laser-driven photochemical reactions can also be used for tooth whitening. In combination with fluoride, laser irradiation can improve the resistance of tooth structure to demineralization, and this application is of particular benefit for susceptible sites in high caries risk patients. Laser technology for caries' removal, cavity preparation and soft tissue surgery is at a high state of refinement, having had several decades of development up to the present time. Used in conjunction with or as a replacement for traditional methods, it is expected that specific laser technologies will become an essential component of contemporary dental practice over the next decade.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The nerve supply of the human prostate is very abundant, and knowledge of the anatomy contributes to successful administration of local anesthesia. However, the exact anatomy of extrinsic neuronal cell bodies of the autonomic and sensory innervation of the prostate is not clear, except in other animals. Branches of pelvic ganglia composed of pelvic (parasympathetic) and hypogastric (sympathetic) nerves innervate the prostate. The autonomic nervous system plays an important role in the growth, maturation, and secretory function of this gland. Prostate procedures under local anesthesia, such as transurethral prostatic resections or transrectal ultrasound-guided prostatic biopsy, are safe, simple, and effective. Local anesthesia can be feasible for many special conditions including uncomplicated prostate surgery and may be particularly useful for the high-risk group of patients for whom inhalation or spinal anesthesia is inadvisable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of MS-222 as an anesthetic for matrinxã juveniles was investigated. At dosage of 100 mg/L or lower fish did not achieve a complete anesthesia state. At 150 mg/L, MS-222 induced anesthesia within 36 seconds and recovered from a 10 minutes period of anesthesia within 5.2 min. Higher concentrations (200, 250 and 300 mg/L) anesthetized fish in lesser times, with the offset of mortality (16.7 and 33.3%) at the 200 and 300 mg/L MS-222 doses, respectively. The only significant differences observed in the hematological parameters, was for the glucose values in fish anesthetized with 250 and 300 mg/L. From the results, the recommended dose of MS-222 for handling matrinxã juveniles is 150 mg/L.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The last twenty years has witnessed important changes in the field of obstetric analgesia and anesthesia. In 2007, we conducted a survey to obtain information regarding the clinical practice of obstetric anesthesia in our country. The main objective was to ascertain whether recent developments in obstetric anesthesia had been adequately implemented into current clinical practice. Methodology: A confidential questionnaire was sent to 391 identified wiss obstetric anesthetists. The questionnaire included 58 questions on 5 main topics: activity and organization of the obstetric unit, practice of labor analgesia, practice of anesthesia for caesarean section, prevention of aspiration syndrome, and pain treatment after cesarean section. Results: The response rate was 80% (311/391). 66% of the surveyed anesthetists worked in intermediate size obstetric units (500-1500 deliveries per year). An anesthetist was on site 24/24 hours in only 53% of the obstetric units. Epidural labor analgesia with low dose local anesthetics combined with opioids was used by 87% but only 30% used patient controlled epidural analgesia (PCEA). Spinal anesthesia was the first choice for elective and urgent cesarean section for 95% of the responders. Adequate prevention of aspiration syndrome was prescribed by 78%. After cesarean section, a multimodal analgesic regimen was prescribed by 74%. Conclusion: When comparing these results with those of the two previous Swiss surveys [1, 2], it clearly appears that Swiss obstetric anesthetists have progressively adapted their practice to current clinical recommendations. But this survey also revealed some insufficiencies: 1. Of the public health system: a. Insufficient number of obstetric anesthetists on site 24 hours/24. b. Lack of budget in some hospitals to purchase PCEA pumps. 2. Of individual medical practice: a. Frequent excessive dosage of hyperbaric bupivacaine during spinal anesthesia for cesarean section. b. Frequent use of cristalloid preload before spinal anesthesia for cesarean section. c. Frequent systematic use of opioids when inducing general anesthesia for cesarean section. d. Fentanyl as the first choice opioid during induction of general anesthesia for severe preeclampsia. In the future, wider and more systematic information campaigns by the mean of the Swiss Association of Obstetric Anesthesia (SAOA) should be able to correct these points.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Résumé: La formation des atélectasies durant l'induction de l'anesthésie générale est plus importante chez le patient obèse morbide. Nous avons démontré dans des travaux de recherche antérieurs que l'utilisation de la PEEP (Pression Positive en Fin d'Expiration) durant l'induction de l'anesthésie prévient la formation d'atélectasies chez des patients non obèses. Par conséquent, nous voulions étudier l'efficacité de la pression positive en fin d'expiration chez le patient obèse morbide dans la prévention de la formation d'atélectasies. Nous avons fait une étude de 23 patients obèses morbides (BMI > 35 kg / m2) dans 2 groupes. Dans le groupe utilisant la pression positive en fin d'expiration, les patients respiraient 100% d'oxygène pendant 5 minutes par l'intermédiaire d'un masque facial type CPAP avec une pression de 10 cm H20. Après l'induction de l'anesthésie, nous avons ventilé les patients au masque facial avec une PEEP de 10 cm H20. Dans le groupe de contrôle, nous avons procédé au même type d'induction sans utiliser la pression positive en fin d'expiration. La surface de poumon atélectatique a été évaluée par tomographie (CT scann). L'étude des échanges gazeux se faisait à 2 reprises, à partir de gazométries réalisées juste avant l'induction de l'anesthésie puis juste après l'intubation. Après l'induction de l'anesthésie et l'intubation, les patients du groupe de contrôle présentaient une quantité d'atélectasies plus importante que les patients du groupe où la PEEP avait été utilisée (10.4% + 4.8% dans le groupe de contrôle versus 1.3% dans le groupe utilisant la pression positive en fin d'expiration p < 0.001). Après l'intubation, en présence d'une fraction inspirée en oxygène à 100%, la Pa02 était significativement supérieure dans le groupe ayant utilisé la pression positive en fin d'expiration en comparaison avec le groupe de contrôle (respectivement 457 ± 130 mmHg versus 315 ± 100 mmHg). Nous avons conclu que chez le patient obèse morbide, le recours à la pression positive en fin d'expiration lors de l'induction de l'anesthésie permet de prévenir largement la formation d'atélectasies et s'accompagne d'une meilleure oxygénation. Abstract: Atelectasis caused by general anesthesia is increased in morbidly obese patients. We have shown that application of positive end-expiratory pressure (PEEP) during the induction of anesthesia prevents atelectasis formation in nonobese patients. We therefore studied the efficacy of PEEP in morbidly obese patients to prevent atelectasis. Twenty-three adult morbidly obese patients (b ody mass index >35 kg/m2) were randomly assigned to one of two groups. In the PEEP group, patients breathed 100% oxygen (5 min) with a continuous positive airway pressure of 10 cm H20 and, after the induction, mechanical ventilation via a face mask with a PEEP of 10 cm H2O. In the control group, the same induction was applied but without continuous positive airway pressure or PEEP. Atelectasis, determined by computed tomography, and blood gas analysis were measured twice: before the induction and directly after intubation. After endotracheal intubation, patients of the control group showed an increase in the amount of atelectasis, which was much larger than in the PEEP group (10.4% -± 4.8% in control group versus 1.7% ± 1.3% in PEEP group; P <0.001). After in.tubation with a fraction of inspired oxygen of 1.0, Pao, was significantly higher in the PEEP group compared with the control group (457 ±- 130 mm Hg versus 315 ± 100 mm Hg, respectively; P = 0.035) We conclude that in morbidly obese patients, atelectasis formation is largely prevented by PEEP applied during the anesthetic induction and is associated with a better oxygenation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: Determine the presence of"burnout" syndrome and characteristic personality patterns in the students and faculty of three graduate programs in Dentistry at the University of Barcelona: Department of Oral Surgery and Implantology, Department of Orthodontics and Department of Integrated Dentistry. Materials and Methods: The study was carried out in 78 dentists. The level of"burnout" was evaluated using the Maslach Burnout Inventory, socio-demographic variables and, finally, the personality test. Results: Oral surgeons constituted the group of highlevel"burnout". The profile of an individual with a propensity to"burn out" is a single man, with a median age of 27, that is in the first years of the graduate program and that combines studies with 30 hours of clinical practice and/or other work (p<0,05). Narcissistic and borderline are the types of personality most frequently found in the individuals that present"burnout" syndrome (p<0,05). Conclusions: In general, no high levels of"burnout" were registered in the studied population, only 2-3%, if applying strict definition of"burnout", and 10% if these criteria were amplified. We believe it is necessary to identify the individuals with a tendency towards"burnout", in order to establish preventive measures and avoid future negative behaviour at work as well as at the personal level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The purpose of this study is to determine the possible differences in deflection between two needles of same length and external gauge but with different internal gauges during truncal block of the inferior alveolar nerve. The initial working hypothesis was that greater deflection may be expected with larger internal gauge needles. Study design: Four clinicians subjected 346 patients to inferior alveolar nerve block and infiltrating anesthesia of the buccal nerve trajectory for the surgical or conventional extraction of the lower third molar. A nonautoaspirating syringe system with 2 types of needle was used: a standard 27-gauge x 35-mm needle with an internal gauge of 0.215 mm or an XL Monoprotect® 27-gauge x 35-mm needle with an internal gauge of 0.265 mm. The following information was systematically recorded for each patient: needle type, gender, anesthetic technique (direct or indirect truncal block) and the number of bone contacts during the procedure, the patient-extraction side, the practitioner performing the technique, and blood aspiration (either positive or negative). Results: 346 needles were used in total. 190 were standard needles (27-gauge x 35-mm needle with an internal gauge of 0.215 mm) and 156 were XL Monoprotect®. Incidence of deflection was observed in 49.1% of cases (170 needles) where 94 were standard needles and 76 XL Monoprotect®. Needle torsion ranged from 0º and 6º. Conclusions: No significant differences were recorded in terms of deflection and internal gauge, operator, patient-extraction side, the anesthetic technique involved and the number of bone contacts during the procedure

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract: The aim of this study was to assess the cardiopulmonary effects, the onset time after the administration of a detomidine/ketamine combination, and the recovery from anesthesia of cougars (Puma concolor) anesthetized with detomidine/ketamine and isoflurane or sevoflurane for abdominal ultrasound imaging. Fourteen animals were randomly allocated into two experimental groups: GISO (n=7) and GSEVO (n=7). Chemical restraint was performed using 0.15mg/kg detomidine combined with 5mg/kg ketamine intramuscularly; anesthesia induction was achieved using 2mg/kg propofol intravenously and maintenance with isoflurane (GISO) or sevoflurane (GSEVO). The following parameters were assessed: heart rate, respiratory rate, systolic and diastolic arterial blood pressure, mean arterial blood pressure, oxyhemoglobin saturation, rectal temperature, central venous pressure, and end-tidal carbon dioxide. The time to sternal recumbency (TSR) and time to standing position (TSP) were also determined. There was not statistically significant difference for the cardiopulmonary variables or TSP whereas TSR was significantly shorter in GSEVO. The time to onset of anesthesia was 11.1±1.2 minutes and 11.3±1.8 minutes for GISO and GSEVO, respectively. The anesthesia of cougars with detomidine/ketamine and isoflurane or sevoflurane was conducted with safety, cardiopulmonary stability, and increased time to sternal recumbency in the GISO group.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)