998 resultados para Anaerobic work
Resumo:
Aim. - This study aimed to test if investigate whether the anaerobic work capacity is replenished while exercising at critical power intensity. Then, a known exercise duration, which demands high anaerobic energy contribution, was compared to intermittent exercise duration with passive and active (cycling at critical power intensity) rest periods.Methods. - Nine participants performed five sessions of testing. From the 1st to the 3rd sessions, individuals cycled continuously at different workloads (P-high, P-intermediate and P-low) in order to estimate the critical power and the anaerobic work capacity. The 4th and 5th sessions were performed in order to determine the influence of anaerobic work capacity replenishment oil exercise duration. They consisted of manipulating the resting type (passive or active) between two cycling efforts. The total exercise duration was determined by the sum of the two cycling efforts duration.Results. - The exercise duration under passive resting condition (408.0 +/- 42.0 s) was longer (p<0.05) than known exercise duration at P-intermediate (T-intermediate = 305.8 +/- 30.5 s) and than exercise duration performed under active resting conditions (T-active = 304.4 +/- 30.7s). However, there was no significant difference between T-intermediate and T-active.Conclusion. - These results demonstrated indirect evidence that the anaerobic work capacity is not replenished while exercising at critical power intensity. (C) 2008 Elsevier Masson SAS. All rights reserved.
Resumo:
The aim of the present study was to verify the applicability of anaerobic work capacity (AWC) determined from the critical power model in elite table tennis players. Eight male international level table tennis players participated in the study. The tests undertaken were: 1) A critical frequency test used to determinate the anaerobic work capacity; 2) Wingate tests were performed using leg and arm ergometers. AWC corresponded to 99.5 +/- 29.1 table tennis balls. AWC was not related to peak (r = -0.25), mean (r = -0.02), relative peak (r = -0.49) or relative mean power (r = 0.01), nor fatigue index (r = -0.52) (Wingate leg ergometer). Similar correlations for peak (r = -0.34), mean (r = -0.04), relative peak (r = -0.49), relative mean power (r = -0.14) and peak blood lactate concentration (r = -0.08) were determined in the Wingate arm ergometer test. Based on these results the AWC determined by a modified critical power test was not a good index for measurement of anaerobic capacity in table tennis players.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal
Resumo:
O desempenho na canoagem de velocidade depende da capacidade de o organismo regenerar ATP em grandes quantidades e a altas taxas, a partir das diferentes vias metabólicas. Assim, o objetivo do presente estudo foi combinar dois modelos bioenergéticos, um genérico denominado de potência crítica e outro específico para a canoagem, proposto por Zamparo et al. (1999), na tentativa de produzir estimativas de aptidão aeróbia e anaeróbia para essa modalidade, bem como estabelecer estimativas não-invasivas da contribuição dos sistemas aeróbio e anaeróbio para diferentes distâncias percorridas. Para tanto, 11 atletas de canoagem (16,0 ± 1,2 anos; 174,0 ± 2,4cm; 65,2 ± 4,4kg), do sexo masculino, percorreram diferentes distâncias (500, 1.000 e 1.790m), na máxima velocidade possível, em embarcações do tipo K-1, em um lago com águas calmas. As informações obtidas foram inicialmente convertidas em quantidades geradas de trabalho (kJ) e potência interna (W). Posteriormente, os valores individuais estimados foram aplicados às três equações preditivas da potência crítica (PCrit) e capacidade de trabalho anaeróbio (CTAnaer). Por fim, os valores produzidos foram transformados em unidades de equivalentes de oxigênio para a estimativa da contribuição aeróbia (equivalente de O2 para a PCrit x tempo para a distância) e anaeróbia (equivalente de O2 para a CTAnaer x tempo para a distância), nas diferentes distâncias. A contribuição aeróbia relativa encontrada para as diferentes distâncias analisadas (500, 1.000 e 1.790m) foi de 60,6, 78,6 e 89,4%, respectivamente. Os resultados encontrados confirmaram as informações produzidas anteriormente por outras investigações, o que sugere que os procedimentos adotados neste estudo podem fornecer estimativas confiáveis sobre a participação das vias energéticas no desempenho de canoagem.
Resumo:
The perceived exertion has been a target of several investigations, many times with association with objective physiological indicators in exercise. Recently, the identification of the perceived exertion threshold (PET) was proposed in the water running, which presented no difference in relation to the critical velocity. Theoretically, both parameters would be indicators of the maximum steady state of variables such as V̇O2 and blood lactate. The objective of this work was to verify the coincidence between PET, critical power (PCrit) and an indicator of maximum V̇O2 steady state (PCrit') in cycle ergometer. Eight male participants were submitted to progressive effort test in order to determine V̇O2peak (46.7 ± 8.5 ml/kg/min) and to four rectangular tests until exhaustion for the estimation of the critical power model parameters, PET and PCrit'. The hyperbolic relation between mechanical power and time spent for the V̇O2peak to be reached in each test was used for the PCrit' estimation, considered as the asymptote in the power axis, and the portion of the anaerobic work capacity (CTAnaer) depleted up to the establishment of the V̇O2peak (CTAnaer'). In order to identify PET, the straight lines angular coefficients of the perceived exertion in time (ordinate) and the powers used (abscissa) were adjusted to a linear function that provided a point in the power axis in which the perceived exertion would be kept indefinitely stable. The parameters PCrit and CTAnaer were estimated by means of the power-time non-linear equation. In order to compare the estimations of PET, PCrit and PCrit', the analysis of variance ANOVA for repeated measurements was employed, and the associations were established through the Pearson correlation. CTAnaer and CTAnaer' were compared through the t test. PET (180 W ± 61 W), PCrit (174 W ± 43 W) and PCrit' (176 W ± 48 W) were not significantly different and the correlations were of 0.92-0.98. CTAnaer' (14,080 ± 5,219 J) was lower than CTAnaer (22,093 ± 9,042 J). One concludes that the PET predicts the intensity of PCrit and PCrit' with accuracy.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Ciências da Motricidade - IBRC
Resumo:
Pós-graduação em Ciências da Motricidade - IBRC
Resumo:
Pós-graduação em Ciências da Motricidade - IBRC
Resumo:
INTRODUÇÃO:O exercício prévio tem importantes implicações na preparação de atletas antes de competições.OBJETIVO:Analisar o efeito de um exercício prévio realizado no domínio pesado no pico de torque (PTORQUE) medido após exercício severo.MÉTODOS:Participaram deste estudo 14 homens ativos (idade: 26 ± 4 anos, VO2max: 44 ± 6 mLO2.min-1.kg-1) que realizaram sete testes em dias diferentes: a) teste progressivo de rampa para determinação do VO2max e da potência pico; b) quatro testes de carga constante para determinação da potência crítica, capacidade de trabalho anaeróbio e potência correspondente ao tempo de exaustão de 3 min (PTLim3min) e; c) dois testes de carga constante de 2 min na PTLim3min seguidos por um sprint all out de 10 s, a fim de medir o PTORQUE. Este último protocolo foi realizado com (EP) e sem (CON) a realização de um exercício prévio pesado.RESULTADOS:O PTORQUE foi significantemente maior após o EP (101 ± 30 Nm) em relação à condição CON (95 ± 23 Nm). O tempo da resposta médio (TRM) do VO2 foi significantemente menor após o EP (24 ± 7 s) em relação à condição CON (32 ± 10 s). A amplitude primária do VO2 aumentou significantemente após o EP (2598 ± 421 mLO2.min-1) em relação à condição CON (2184 ± 246 mLO2.min-1). O déficit de O2 foi significantemente menor após o exercício prévio (980 ± 432 mLO2) em relação à condição CON (1273 ± 398 mLO2). Houve correlação significante entre a variação do déficit de O2 com a do PTORQUE (r = 0,53) e da variação do TRM com a do PTORQUE (r = 0,53).CONCLUSÃO:Pode-se concluir que o PTORQUE é maior após exercício aeróbio de curta duração precedido do EP. Deste modo, esta estratégia pode ser interessante como preparação para algumas competições esportivas.
Resumo:
The objective of this study was to analyze the influence of previous exercise on the determination of critical power (CP). Seven apparently healthy nontrained males, of 18 to 25 years, participated of this study. The subjects were submitted, in different days to the following protocols in a cyclergometer: 1) one progressive test until voluntary exhaustion for the determination of lactate threshold (LL), maximal oxygen uptake (VO2max) and its corresponding intensity (IVO2max); 2) six constant workload tests at 95,100 and 110% IVO2max until exhaustion with and without a previous exercise at 70% , in random order. The exhaustion times (tlim) at 95, 100 and 110% IVO2max were adjusted forme thress models of two parameters to estimate CP and anaerobic work capacity (AWC) [P=CTAn/tlim)+CP; tlim = CTAn/(P-PC); P=PC.tlim+ CTAn]. The model with the lowest standard error was considered for the estimation of CP. The tlim at 95% IVO2max was similar without (501 ± 140 s) and with previous exercise (473 ± 99 s). However, the tlim at 100% (381 ± 103 s and 334 ± 101 s) and 110% IVO2max (267 ± 163 s and 227 ± 68 s) was significantly longer with previous exercise. There was no significant difference in CP and AWCat conditions without (200 ± 27 W and 23 ± 11 kJ, respectively) and with previous exercise (212 ± 30 W and 18 ± 8 kJ, respectively). It can be concluded that the parameters of the relationship between power and time were not modified by the previous severe exercise
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)