995 resultados para Anaerobic power


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to verify the correlation between the Wingate arm crank test outputs (peak power, mean power, and fatigue index), obtained on a specific ergometer, and the performance in crawl stroke swim sprints of 14, 25, 50, and 400 m. The experiment was conducted with 9 healthy male volunteers (18.1 +/- 2.2 years of age; 172 +/- 0.04 cm; 67.7 +/- 5.92 kg and 15.7 +/- 4.57% body fat). on determined days, all individuals were submitted to the Wingate arm crank test and crawl freestyle sprints of 14, 25, 50, and 400 m as they were timed with a stopwatch. The peak power, the mean power, and the fatigue index, which were obtained during the Wingate arm crank test, were not significantly correlated with the maximum swim velocities during the crawl free-style tests of 14 (r = 0.40; r = 0.64; r = 0.11), 25 (r = 0.28; r = 0.39; r = -0.27), 50 (r = 0.03; r = 0.09; r = -0.31), and 400 (r = -0.52; r = -0.37; r = -0.65) m respectively. Thus, it is possible to conclude that the Wingate arm crank test is not suitable to assess the anaerobic power of swimmers under the described experimental conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to verify the correlation between the Wingate arm crank test outputs (peak power, mean power, and fatigue index), obtained on a specific ergometer, and the performance in crawl stroke swim sprints of 14, 25, 50, and 400 m. The experiment was conducted with 9 healthy male volunteers (18.1 ± 2.2 years of age; 172 ± 0.04 cm; 67.7 ± 5.92 kg and 15.7 ± 4.57% body fat). On determined days, all individuals were submitted to the Wingate arm crank test and crawl freestyle sprints of 14, 25, 50, and 400 m as they were timed with a stopwatch. The peak power, the mean power, and the fatigue index, which were obtained during the Wingate arm crank test, were not significantly correlated with the maximum swim velocities during the crawl freestyle tests of 14 (r = 0.40; r = 0.64; r = 0.11), 25 (r = 0.28; r = 0.39; r = -0.17), 50 (r = 0.03; r = 0.09; r = -0.31), and 400 (r = -0.52; r = -0.37; r = -0.65) m, respectively. Thus, it is possible to conclude that the Wingate arm crank test is not suitable to assess the anaerobic power of swimmers under the described experimental conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the use of the running anaerobic sprint test (RAST) as a predictor of anaerobic capacity, compare it to the maximal accumulated oxygen deficit (MAOD) and to compare the RAST's parameters with the parameters of 30-s all-out tethered running on a treadmill. 39 (17.0±1.4 years) soccer players participated in this study. The participants underwent an incremental test, 10 submaximal efforts [50-95% of velocity correspondent to VO2MAX (vVO2MAX)] and one supramaximal effort at 110% of vVO2MAX for the determination of MAOD. Furthermore, the athletes performed the RAST. In the second stage the 30-s all-out tethered running was performed on a treadmill (30-s all-out), and compared with RAST. No significant correlation was observed between MAOD and RAST parameters. However, significant correlations were found between the power of the fifth effort (P5) of RAST with peak and mean power of 30-s all-out (r=0.73 and 0.50; p<0.05, respectively). In conclusion, the parameters from RAST do not have an association with MAOD, suggesting that this method should not be used to evaluate anaerobic capacity. Although the correlations between RAST parameters with 30-s all-out do reinforce the RAST as an evaluation method of anaerobic metabolism, such as anaerobic power.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The purpose of the study was to investigate the effect of skate blade radius of hollow (ROH) on anaerobic performance, specifically during the acceleration and stopping phases of an on-ice skating test. Fifteen, male Junior B hockey players (mean age 19 y ± 1.46) were recruited to participate. On-icc testing required each participant to complete an on-ice anaerobic performance test [Reed Repeat Skate (RRS)) on three separate days. During each on-ice test, the participant's skate blades were sharpened to one of three, randomly assigned, ROH values (0.63 cm, 1.27 cm, 1.90 cm). Performance times were recorded during each RRS and used to calculate anaerobic variables [anaerobic power (W), anaerobic capacity (W), and fatigue index (s, %)). Each RRS was video recorded for the purpose of motion analysis. Video footage was imported into Peak Motus™ to measure kinematic variables of the acceleration and stopping phases. The specific variables calculated from the acceleration phase were: average velocity over 6 m (m/s), average stride length (m), and mean stride rate (strides/s). The specific variables calculated from the stopping phase were: velocity at initiation of stopping (rn/s), stopping distance (m), stopping time (s). A repeated measures ANOV A was used to assess differences in mean performance and kinematic variables across the three selected hollows. Further analysis was conducted to assess differences in trial by trial performance and kinematic variables for all hollows. The primary findings of the study suggested that skate blade ROH can have a significant effect on kinematic variables, namely stride length and stride rate during the acceleration phase and stopping distance and stopping time during the stopping phase of an on-ice anaerobic performance test. During the acceleration phase, no significant difdifferences were found in SR and SL across the three selected hollows. Mean SR on the 1.27 cm hollow was significantly slower than both the 0.63 cm and 1.90 cm hollows and SL was significantly longer when skating on the 1.27 cm hollow in comparison to the 1.90 cm hollow. During the stopping phase, stopping distance on the 0.63 cm hollow (4.12 m ± 0.14) was significantly shorter than both the 1.27 cm hollow (4.43 m ± 0.08) (p < 0.05) and the 1.90 cm ho])ow (4.35 m ± 0.12) (p < 0.05). Mean ST was also significantly shorter when stopping on the 0.63 cm hollow then both the 1.27 cm and 1.90 cm hollows. Trial by trial results clearly illustrated the affect of fatigue on kinematic variables; AV, SR, IV decreased from trial 1 to 6. There was no significant effect on anaerobic performance variables during the RRS. Altering the skate blade ROH has a significant and practical affect on accelerating and stopping performance will be discussed in this paper.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Purpose The purpose of the study was to investigate a possible association between the distance covered in the Hoff test with parameters of maximal oxygen uptake (V_O2MAX), anaerobic threshold, anaerobic fitness, and body composition of professional adult soccer players. Methods Twenty-five professional soccer players (20 ± 3 years) participated in the study. On different days the athletes performed: a graded incremental exercise test in a laboratory to measure V_O2MAX; a specific soccer field test called the Hoff test; a running anaerobic sprint test (RAST); an incremental test on an oval circuit to determine the velocity relative to anaerobic threshold (VAnT) and an estimation of body composition. Results The average V_O2MAX corresponded to 4.1 ± 0.1 L min-1 (54.1 ± 1.2 mL kg-1 min-1 ). The average distance covered during the Hoff test was 1,442.4 ± 30.0 m. The distance covered during the Hoff test showed significant correlations with absolute and expressed in an appropriated scale V_O2MAX (r = 0.44, p = 0.02; r = 0.42, p = 0.02, respectively) while no significant differences were found with body composition, VAnT and RAST variables. Conclusions The present study demonstrated that the distance covered during the Hoff test has weak correlation with V_O2MAX determined in treadmill running, and no correlation with VAnT, body composition and RAST outcomes, probably due to the non-specificity of the proposed tests when associated with the Hoff test.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O objetivo deste estudo foi determinar, em mesatenistas bem treinados, as aptidões aeróbia e anaeróbia. Participaram do presente estudo oito mesatenistas brasileiros treinados do sexo masculino (18±2 anos). Os sujeitos foram submetidos a um teste incremental específico para determinação do consumo pico de oxigênio (VO2PICO), intensidade associada ao VO2PICO (iVO2PICO) e do ponto de compensação respiratório (PCR) e a dois testes de esforço repetitivo, sendo o teste de RAST e o índice anaeróbio alático (IAA), para determinação dos índices anaeróbios. O VO2PICO correspondeu a 50,5±4,4ml kg-1 min-1 , a iVO2PICO a 52,1±9,6 bolas min-1 e o PCR a 44,9±8,0 bolas min-1. No RAST, a potência pico (PP) e a potência média (PM) relativa corresponderam a 9,0±1,3W kg-1 e 7,0±0,9W kg-1, respectivamente, enquanto que o IAA foi 1,14±0,51 mM/m s-1 . Esses valores de VO2PICO e dos parâmetros anaeróbios quando comparados a valores de outros esportes com raquetes caracterizaram que mesatenistas brasileiros treinados apresentam potência aeróbia moderada e potência anaeróbia é baixa.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to verify the effect of selective loads model in professional futsal players, during a preparatory mesocycle. Nine futsal professional players (23±2 anos), from the team of Federation Paulista of soccer indoor championship, composed the sample, characterized by intentional. The players were evaluated in two moments although of a preparatory mesocycle, microcycle 2 (PRE) and microcycle 7 (POS), by the tests of intermittent aerobic fitness, horizontal jump, one leg triple jump, velocity of 15m, agility and anaerobic power. The statistical analysis included the Student-t and Wilxocon tests (P<0.05). The results of horizontal jump, intermittent aerobic fitness and medium power improved, the velocity at 15 m decreased. The select loads model is a good option for the periodization to preparatory mesocycle in futsal.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to examine changes on anaerobic power after competitive period in professional soccer players. Twenty five male was evaluated before (PRE) and after (POS) competitive period. To assess anaerobic power was used running based on anaerobic sprint test (RAST), which were determined the maximum power (MAXP), medium power (MEDP), minimum power (MINP) and fatigue index (FI). The test was performed in the first (PRE) and the last (POS) training session of competitive period, wich lasted 20 weeks. There were no significant difference (p>0,05) in POS condition compared to PRE condition on MAXP (10,70 ± 0,95 vs 10,83 ± 0,87), MINP (8,48 ± 0,92 vs 8,28 ± 0,76), MEDP (9,52 ± 0,83 vs 9,41 ± 0,61) and FI (22,73 ± 7,48 vs 25,53 ± 8,79). There was no significant change on anaerobic power after a competitive period wich lasted 20 weeks in professional soccer players.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

There is little information on Caribbean soccer players. Thus, the aim this study was to descriptive and to compare the anthropometric, motor and aerobic fitness profile between Trinidad and Tobago team professional and junior soccer players. Twenty six soccer players were evaluated (14 professional and 12 junior): anthropometric (height, body mass, BMI, body fat percent), flexibility (sit and reach), velocity (30 m), explosive strength (horizontal and vertical jump), anaerobic power (maximum, mean and minimum power, index of fatigue) and maximum aerobic power. Student Test-t to independent sample was used in statistical analyzes, considering 5% of significance (p<0,05). Results of professional and junior players were, respectively: height (180,6 ± 8,1; 175,0 ± 6,9 cm), body mass (77,1 ± 7,5; 70,6 ± 8,7 kg); BMI (23,6 ± 1,5 / 23,0 ± 1,6 kgm 2 ); body fat (11,9 ± 1,7; 11,6 ± 1,2 %); sitting and reaching (24,9 ± 10,3; 24,9 ± 7,7 cm); velocity (30 m) (4,61 ± 0,14; 4,66 ± 0,15 s); horizontal jump (263,4 ± 14,9; 239,7 ± 12,1 cm); vertical jump (58,7 ± 4,3; 54,6 ± 6,6 cm); maximum power (7,9 ± 0,9; 6,6 ± 0,8 w∙kg-1 ); mean power (6,5 ± 0,7; 5,4 ± 0,9 w∙kg-1 ); minimum power (5,3 ± 0,7; 4,3 ± 1,1 w∙kg-1 ); index of fatigue (33,0 ± 7,9; 34,8 ± 12,8 %); aerobic power (55,0 ± 3,2; 57,2 ± 4,8 ml∙kg-1 ∙min-1 ). Professional players presented higher horizontal jump and maximum, mean and minimum anaerobic power in comparing to the junior players. The highest values of power tests for the lower limbs may be relationship to the longer time of practice in the modality of professional players, which can also indicate a higher level of specialization, which gives priority to the training of power (force and velocity).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Anaerobic efforts are commonly required through repeated sprint during efforts in many sports, making the anaerobic pathway a target of training. Nevertheless, to identify improvements on such energetic way it is necessary to assess anaerobic capacity or power, which is usually complex. For this purpose, authors have postulated the use of short running performances to anaerobic ability assessment. Thus, the aim of this study was to find a relationship between running performances on anaerobic power, anaerobic capacity or repeated sprint ability. Methods Thirteen military performed maximal running of 50 (P50), 100 (P100) and 300 (P300) m on track, beyond of running-based anaerobic sprint test (RAST; RSA and anaerobic power test), maximal anaerobic running test (MART; RSA and anaerobic capacity test) and the W′ from critical power model (anaerobic capacity test). Results By RAST variables, peak and average power (absolute and relative) and maximum velocity were significantly correlated with P50 (r = −0.68, p = 0.03 and −0.76, p = 0.01; −0.83, p < 0.01 and −0.83, p < 0.01; and −0.78, p < 0.01), respectively. The maximum intensity of MART was negatively and significantly correlated with P100 (r = −0.59) and W′ was not statistically correlated with any of the performances. Conclusion MART and W′ were not correlated with short running performances, having a weak performance predicting probably due to its longer duration in relation to assessed performances. Observing RAST outcomes, we postulated that such a protocol can be used during daily training as short running performance predictor.