1000 resultados para Anàlisi dimensional


Relevância:

60.00% 60.00%

Publicador:

Resumo:

El projecte correspon a la assignatures de 1r curs de Fonaments Físics a l’Enginyeria Mecànica. El projecte correspon a un treball de síntesi dels conceptes i les seves aplicacions dels següents temes: 1.Anàlisi dimensional. 2.Camp elèctric: 2.1. Intensitat de camp elèctric. 2.2. Potencial elèctric. 2.3. Característiques elèctriques dels aïllants i conductors. 2.4. Conductors en equilibri electrostàtic. 3.Electrocinètica: 3.1. Resistivitat i resistència. 3.2. Llei d’Ohm

Relevância:

30.00% 30.00%

Publicador:

Resumo:

"vegeu el resum a l'inici del document del fitxer adjunt."

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We consider negotiations selecting one-dimensional policies. Individuals have single-peaked preferences, and they are impatient. Decisions arise from a bargaining game with random proposers and (super) majority approval, ranging from the simple majority up to unanimity. The existence and uniqueness of stationary subgame perfect equilibrium is established, and its explicit characterization provided. We supply an explicit formula to determine the unique alternative that prevails, as impatience vanishes, for each majority. As an application, we examine the efficiency of majority rules. For symmetric distributions of peaks unanimity is the unanimously preferred majority rule. For asymmetric populations rules maximizing social surplus are characterized.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We construct a new family of semi-discrete numerical schemes for the approximation of the one-dimensional periodic Vlasov-Poisson system. The methods are based on the coupling of discontinuous Galerkin approximation to the Vlasov equation and several finite element (conforming, non-conforming and mixed) approximations for the Poisson problem. We show optimal error estimates for the all proposed methods in the case of smooth compactly supported initial data. The issue of energy conservation is also analyzed for some of the methods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The work in this paper concerns the study of conventional and refined heat balance integral methods for a number of phase change problems. These include standard test problems, both with one and two phase changes, which have exact solutions to enable us to test the accuracy of the approximate solutions. We also consider situations where no analytical solution is available and compare these to numerical solutions. It is popular to use a quadratic profile as an approximation of the temperature, but we show that a cubic profile, seldom considered in the literature, is far more accurate in most circumstances. In addition, the refined integral method can give greater improvement still and we develop a variation on this method which turns out to be optimal in some cases. We assess which integral method is better for various problems, showing that it is largely dependent on the specified boundary conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigate in this note the dynamics of a one-dimensional Keller-Segel type model on the half-line. On the contrary to the classical configuration, the chemical production term is located on the boundary. We prove, under suitable assumptions, the following dichotomy which is reminiscent of the two-dimensional Keller-Segel system. Solutions are global if the mass is below the critical mass, they blow-up in finite time above the critical mass, and they converge to some equilibrium at the critical mass. Entropy techniques are presented which aim at providing quantitative convergence results for the subcritical case. This note is completed with a brief introduction to a more realistic model (still one-dimensional).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aquest projecte és una anàlisi d'algunes tècniques de reconeixement d'objectes en 2D, la seva comparació i equivalència. La solució presentada en aquesta memòria ha estat implementada en C++ per a poder avaluar els resultats així com les diferents problemàtiques aparegudes durant tot el procés. La resolució de puzzles és tan sols un exemple dels múltiples casos d'objectes bidimensionals que ens podem trobar que necessiten tècniques de matching per obtenir un objecte global.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

 Mitjançant imatges estereoscòpiques es poden detectar la posició respecte dela càmera dels objectes que apareixen en una escena. A partir de lesdiferències entre les imatges captades pels dos objectius es pot determinar laprofunditat dels objectes. Existeixen diversitat de tècniques de visió artificialque permeten calcular la localització dels objectes, habitualment amb l’objectiude reconstruir l’escena en 3D. Aquestes tècniques necessiten una gran càrregacomputacional, ja que utilitzen mètodes de comparació bidimensionals, i pertant, no es poden utilitzar per aplicacions en temps real.En aquest treball proposem un nou mètode d’anàlisi de les imatgesestereoscòpiques que ens permeti obtenir la profunditat dels objectes d’unaescena amb uns resultats acceptables. Aquest nou mètode es basa entransformar la informació bidimensional de la imatge en una informacióunidimensional per tal de poder fer la comparació de les imatges amb un baixcost computacional, i dels resultats de la comparació extreure’n la profunditatdels objectes dins l’escena. Això ha de permetre, per exemple, que aquestmètode es pugui implementar en un dispositiu autònom i li permeti realitzaroperacions de guiatge a través d’espais interiors i exteriors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mitjançant imatges estereoscòpiques es poden detectar la posició respecte de la càmera dels objectes que apareixen en una escena. A partir de les diferències entre les imatges captades pels dos objectius es pot determinar la profunditat dels objectes. Existeixen diversitat de tècniques de visió artificial que permeten calcular la localització dels objectes, habitualment amb l’objectiu de reconstruir l’escena en 3D. Aquestes tècniques necessiten una gran càrrega computacional, ja que utilitzen mètodes de comparació bidimensionals, i per tant, no es poden utilitzar per aplicacions en temps real. En aquest treball proposem un nou mètode d’anàlisi de les imatges estereoscòpiques que ens permeti obtenir la profunditat dels objectes d’una escena amb uns resultats acceptables. Aquest nou mètode es basa en transformar la informació bidimensional de la imatge en una informació unidimensional per tal de poder fer la comparació de les imatges amb un baix cost computacional, i dels resultats de la comparació extreure’n la profunditat dels objectes dins l’escena. Això ha de permetre, per exemple, que aquest mètode es pugui implementar en un dispositiu autònom i li permeti realitzar operacions de guiatge a través d’espais interiors i exteriors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although various abutment connections and materials have recently been introduced, insufficient data exist regarding the effect of stress distribution on their mechanical performance. The purpose of this study was to investigate the effect of different abutment materials and platform connections on stress distribution in single anterior implant-supported restorations with the finite element method. Nine experimental groups were modeled from the combination of 3 platform connections (external hexagon, internal hexagon, and Morse tapered) and 3 abutment materials (titanium, zirconia, and hybrid) as follows: external hexagon-titanium, external hexagon-zirconia, external hexagon-hybrid, internal hexagon-titanium, internal hexagon-zirconia, internal hexagon-hybrid, Morse tapered-titanium, Morse tapered-zirconia, and Morse tapered-hybrid. Finite element models consisted of a 4×13-mm implant, anatomic abutment, and lithium disilicate central incisor crown cemented over the abutment. The 49 N occlusal loading was applied in 6 steps to simulate the incisal guidance. Equivalent von Mises stress (σvM) was used for both the qualitative and quantitative evaluation of the implant and abutment in all the groups and the maximum (σmax) and minimum (σmin) principal stresses for the numerical comparison of the zirconia parts. The highest abutment σvM occurred in the Morse-tapered groups and the lowest in the external hexagon-hybrid, internal hexagon-titanium, and internal hexagon-hybrid groups. The σmax and σmin values were lower in the hybrid groups than in the zirconia groups. The stress distribution concentrated in the abutment-implant interface in all the groups, regardless of the platform connection or abutment material. The platform connection influenced the stress on abutments more than the abutment material. The stress values for implants were similar among different platform connections, but greater stress concentrations were observed in internal connections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the effect of simulated microwave disinfection (SMD) on the linear dimensional changes, hardness and impact strength of acrylic resins under different polymerization cycles. Metal dies with referential points were embedded in flasks with dental stone. Samples of Classico and Vipi acrylic resins were made following the manufacturers' recommendations. The assessed polymerization cycles were: A-- water bath at 74ºC for 9 h; B-- water bath at 74ºC for 8 h and temperature increased to 100ºC for 1 h; C-- water bath at 74ºC for 2 h and temperature increased to 100ºC for 1 h;; and D-- water bath at 120ºC and pressure of 60 pounds. Linear dimensional distances in length and width were measured after SMD and water storage at 37ºC for 7 and 30 days using an optical microscope. SMD was carried out with the samples immersed in 150 mL of water in an oven (650 W for 3 min). A load of 25 gf for 10 sec was used in the hardness test. Charpy impact test was performed with 40 kpcm. Data were submitted to ANOVA and Tukey's test (5%). The Classico resin was dimensionally steady in length in the A and D cycles for all periods, while the Vipi resin was steady in the A, B and C cycles for all periods. The Classico resin was dimensionally steady in width in the C and D cycles for all periods, and the Vipi resin was steady in all cycles and periods. The hardness values for Classico resin were steady in all cycles and periods, while the Vipi resin was steady only in the C cycle for all periods. Impact strength values for Classico resin were steady in the A, C and D cycles for all periods, while Vipi resin was steady in all cycles and periods. SMD promoted different effects on the linear dimensional changes, hardness and impact strength of acrylic resins submitted to different polymerization cycles when after SMD and water storage were considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the effect of simulated microwave disinfection (SMD) on the linear dimensional changes, hardness and impact strength of acrylic resins under different polymerization cycles. Metal dies with referential points were embedded in flasks with dental stone. Samples of Classico and Vipi acrylic resins were made following the manufacturers' recommendations. The assessed polymerization cycles were: A) water bath at 74 ºC for 9 h; B) water bath at 74 ºC for 8 h and temperature increased to 100 ºC for 1 h; C) water bath at 74 ºC for 2 h and temperature increased to 100 ºC for 1 h; and D) water bath at 120 ºC and pressure of 60 pounds. Linear dimensional distances in length and width were measured after SMD and water storage at 37 ºC for 7 and 30 days using an optical microscope. SMD was carried out with the samples immersed in 150 mL of water in an oven (650 W for 3 min). A load of 25 gf for 10 s was used in the hardness test. Charpy impact test was performed with 40 kpcm. Data were submitted to ANOVA and Tukey's test (5%). The Classico resin was dimensionally steady in length in the A and D cycles for all periods, while the Vipi resin was steady in the A, B and C cycles for all periods. The Classico resin was dimensionally steady in width in the C and D cycles for all periods, and the Vipi resin was steady in all cycles and periods. The hardness values for Classico resin were steady in all cycles and periods, while the Vipi resin was steady only in the C cycle for all periods. Impact strength values for Classico resin were steady in the A, C and D cycles for all periods, while Vipi resin was steady in all cycles and periods. SMD promoted different effects on the linear dimensional changes, hardness and impact strength of acrylic resins submitted to different polymerization cycles when after SMD and water storage were considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High pressure homogenization (HPH) is a non-thermal method, which has been employed to change the activity and stability of biotechnologically relevant enzymes. This work investigated how HPH affects the structural and functional characteristics of a glucose oxidase (GO) from Aspergillus niger. The enzyme was homogenized at 75 and 150 MPa and the effects were evaluated with respect to the enzyme activity, stability, kinetic parameters and molecular structure. The enzyme showed a pH-dependent response to the HPH treatment, with reduction or maintenance of activity at pH 4.5-6.0 and a remarkable activity increase (30-300%) at pH 6.5 in all tested temperatures (15, 50 and 75°C). The enzyme thermal tolerance was reduced due to HPH treatment and the storage for 24 h at high temperatures (50 and 75°C) also caused a reduction of activity. Interestingly, at lower temperatures (15°C) the activity levels were slightly higher than that observed for native enzyme or at least maintained. These effects of HPH treatment on function and stability of GO were further investigated by spectroscopic methods. Both fluorescence and circular dichroism revealed conformational changes in the molecular structure of the enzyme that might be associated with the distinct functional and stability behavior of GO.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Low-density nanostructured foams are often limited in applications due to their low mechanical and thermal stabilities. Here we report an approach of building the structural units of three-dimensional (3D) foams using hybrid two-dimensional (2D) atomic layers made of stacked graphene oxide layers reinforced with conformal hexagonal boron nitride (h-BN) platelets. The ultra-low density (1/400 times density of graphite) 3D porous structures are scalably synthesized using solution processing method. A layered 3D foam structure forms due to presence of h-BN and significant improvements in the mechanical properties are observed for the hybrid foam structures, over a range of temperatures, compared with pristine graphene oxide or reduced graphene oxide foams. It is found that domains of h-BN layers on the graphene oxide framework help to reinforce the 2D structural units, providing the observed improvement in mechanical integrity of the 3D foam structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Plackett-Burman experimental design was applied for the robustness assessment of GC×GC-qMS (Comprehensive Two-Dimensional Gas Chromatography with Fast Quadrupolar Mass Spectrometric Detection) in quantitative and qualitative analysis of volatiles compounds from chocolate samples isolated by headspace solid-phase microextraction (HS-SPME). The influence of small changes around the nominal level of six factors deemed as important on peak areas (carrier gas flow rate, modulation period, temperature of ionic source, MS photomultiplier power, injector temperature and interface temperature) and of four factors considered as potentially influential on spectral quality (minimum and maximum limits of the scanned mass ranges, ions source temperature and photomultiplier power). The analytes selected for the study were 2,3,5-trimethylpyrazine, 2-octanone, octanal, 2-pentyl-furan, 2,3,5,6-tetramethylpyrazine, and 2-nonanone e nonanal. The factors pointed out as important on the robustness of the system were photomultiplier power for quantitative analysis and lower limit of mass scanning range for qualitative analysis.