774 resultados para Alternate current


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Oral administration is the most convenient route for drug therapy. The knowledge of the gastrointestinal transit and specific site for drug delivery is a prerequisite for development of dosage forms. The aim of this work was to demonstrate that is possible to monitor the disintegration process of film-coated magnetic tablets by multi-sensor alternate current Biosusceptometry (ACB) in vivo and in vitro. This method is based on the recording of signals produced by the magnetic tablet using a seven sensors array and signal-processing techniques. The disintegration was confirmed by signals analysis in healthy human volunteers' measurements and in vitro experiments. Results showed that ACB is efficient to characterize the disintegration of dosage forms in the stomach, being a research tool for the development of new pharmaceutical dosage forms. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. Gastrointestinal (GI) complications are common after renal transplantation, mainly owing to immunosuppressive therapy. Assessment of GI transit time can facilitate rational management of these disorders.Objective. We evaluate the GI transit parameters in renal transplant recipients taking tacrolimus, azathioprine, and prednisone with the use of the alternate current biosusceptometry (ACB) technique and compared them with healthy volunteers.Methods. Ten renal transplant recipients and 10 healthy volunteers were enrolled in this study. After an overnight fast, patients and volunteers ingested a standard meal containing magnetic markers. The biomagnetic monitoring was performed at 10-minute intervals for at least 8 hours to obtain gastric emptying as well as the colonic arrival time-intensity curves. Mean gastric emptying time (MGET), mean colon arrival time (MCAT), and mean small intestinal transit time (MSITT) were quantified and compared between control and patient groups with results expressed as mean +/- SD.Results. The MGET measured by the ACB technique was 48 +/- 31 minutes and 197 +/- 50 minutes for patients and healthy subjects, respectively. MSITT and MCAT values calculated for patients versus volunteers were 171 +/- 71 minutes versus 197 +/- 71 minutes and 219 +/- 83 minutes versus 373 +/- 52 minutes, respectively. Renal transplant recipients showed significantly faster; gastric emptying and colon arrival times (P < .001) compared with normal volunteers; however, small intestinal transit time was not significantly different (P = .44).Conclusions. In stable renal transplant recipients, the GI transit parameters were significantly faster than in normal healthy volunteers. ACB sensors are versatile technologies that can be used for clinical research, because they offer an excellent opportunity to evaluate GI transit in a noninvasive manner without the use of ionizing radiation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Oral administration is the most convenient route for drug therapy. The knowledge of the gastrointestinal transit and specific site for drug delivery is a prerequisite for development of dosage forms. The aim of this work was to demonstrate that is possible to monitor the disintegration process of film-coated magnetic tablets by multi-sensor alternate current Biosusceptometry (ACB) in vivo and in vitro. This method is based on the recording of signals produced by the magnetic tablet using a seven sensors array and signal-processing techniques. The disintegration was confirmed by signals analysis in healthy human volunteers' measurements and in vitro experiments. Results showed that ACB is efficient to characterize the disintegration of dosage forms in the stomach, being a research tool for the development of new pharmaceutical dosage forms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"Schedule of some British patents bearing on polyphase and alternating-current motors," p. 483-488.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this paper is proposed and analyzed a digital hysteresis modulation using a FPGA (Field Programmable Gate Array) device and VHDL (Hardware Description Language), applied at a hybrid three-phase rectifier with almost unitary input power factor, composed by parallel SEPIC controlled single-phase rectifiers connected to each leg of a standard 6-pulses uncontrolled diode rectifier. The digital control allows a programmable THD (Total Harmonic Distortion) at the input currents, and it makes possible that the power rating of the switching-mode converters, connected in parallel, can be a small fraction of the total average output power, in order to obtain a compact converter, reduced input current THD and almost unitary input power factor. Finally, the proposed digital control, using a FPGA device and VHDL, offers an important flexibility for the associated control technique, in order to obtain a programmable PFC (Power Factor Correction) hybrid three-phase rectifier, in agreement with the international standards (IEC, and IEEE), which impose limits for the THD of the AC (Alternate Current) line input currents. The proposed strategy is verified by experiments. © 2008 IEEE.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Teachers are deeply concerned on how to be more effective in our task of teaching. We must organize the contents of our specific area providing them with a logical configuration, for which we must know the mental structure of the students that we have in the classroom. We must shape this mental structure, in a progressive manner, so that they can assimilate the contents that we are trying to transfer, to make the learning as meaningful as possible. In the generative learning model, the links before the stimulus delivered by the teacher and the information stored in the mind of the learner requires an important effort by the student, who should build new conceptual meanings. That effort, which is extremely necessary for a good learning, sometimes is the missing ingredient so that the teaching-learning process can be properly assimilated. In electrical circuits, which we know are perfectly controlled and described by Ohm's law and Kirchhoff's two rules, there are two concepts that correspond to the following physical quantities: voltage and electrical resistance. These two concepts are integrated and linked when the concept of current is presented. This concept is not subordinated to the previous ones, it has the same degree of inclusiveness and gives rise to substantial relations between the three concepts, materializing it into a law: The Ohm, which allows us to relate and to calculate any of the three physical magnitudes, two of them known. The alternate current, in which both the voltage and the current are reversed dozens of times per second, plays an important role in many aspects of our modern life, because it is universally used. Its main feature is that its maximum voltage is easily modifiable through the use of transformers, which greatly facilitates its transfer with very few losses. In this paper, we present a conceptual map so that it is used as a new tool to analyze in a logical manner the underlying structure in the alternate current circuits, with the objective of providing the students from Sciences and Engineering majors with another option to try, amongst all, to achieve a significant learning of this important part of physics.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background The aim of this study was to validate a biomagnetic method (alternate current biosusceptometry, ACB) for monitoring gastric wall contractions in rats. Methods In vitro data were obtained to establish the relationship between ACB and the strain-gauge (SG) signal amplitude. In vivo experiments were performed in pentobarbital-anesthetized rats with SG and magnetic markers previously implanted under the gastric serosa or after ingestion of magnetic material. Gastric motility was quantified from the tracing amplitudes and frequency profiles obtained by Fast Fourier Transform. Key Results The correlation between in vitro signal amplitudes was strong (R = 0.989). The temporal cross-correlation coefficient between the ACB and SG signal amplitude was higher (P < 0.0001) in the postprandial (88.3 +/- 9.1 V) than in the fasting state (31.0 +/- 16.9 V). Irregular signal profiles, low contraction amplitudes, and smaller signal-to-noise ratios explained the poor correlation between techniques for fasting-state recordings. When a magnetic material was ingested, there was also strong correlation in the frequency and signal amplitude and a small phase-difference between the techniques. The contraction frequencies using ACB were 0.068 +/- 0.007 Hz (postprandial) and 0.058 +/- 0.007 Hz (fasting) (P < 0.002) and those using SG were 0.066 +/- 0.006 Hz (postprandial) and 0.059 +/- 0.008 Hz (fasting) (P < 0.005). Conclusions & Inferences In summary, ACB is reliable for monitoring gastric wall contractions using both implanted and ingested magnetic materials, and may serve as an accurate and sensitive technique for gastrointestinal motility studies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Este trabalho baseia se na necessidade de aumentar as fontes renováveis de energia, reduzindo assim a dependência de fontes não renováveis, principalmente as poluentes como as de provenientes de combustíveis fosseis. A fonte de energia renovável explorada neste trabalho é a advinda de energia solar, com a utilização de painéis solares e métodos de extração para converter esta energia em energia elétrica e assim poder utilizar esta energia de forma eficiente. A energia produzida por painéis fotovoltaicos se apresenta em forma de corrente continua, tendo assim a necessidade do uso de conversores CC-CA, ou ditos inversores de tensão, para utilização da mesma, já que a maioria do equipamentos que utilizam energia elétrica são construídos em forma a serem abastecidos com energia elétrica em corrente alternada. Como este trabalho foca na injeção da energia produzida pelos painéis FV na rede de distribuição de baixa tensão, faz se necessário o uso de um PLL para garantir que o sistema inversor esteja em sincronismo com a rede de distribuição e possa garantir a entrega de energia ativa. Por fim mas não menos importante, é utilizado neste projeto técnicas de MPPT para garantir um maior aproveitamento da energia proveniente dos painéis FV, ajudando assim a melhorar a eficácia deste tipo de energia, sendo mais fiável e viável.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper deals with a computing simulation for an offshore wind energy system taking into account the influence of the marine waves action throughout the floating platform. The wind energy system has a variable-speed turbine equipped with a permanent magnet synchronous generator and a full-power five level converter, injecting energy into the electric grid through a high voltage alternate current link. A reduction on the unbalance of the voltage in the DC-link capacitors of the five-level converter is proposed by a strategic selection of the output voltage vectors. The model for the drive train of the wind energy system is a two mass model, including the dynamics of the floating platform. A case study is presented and the assessment of the quality of the energy injected into the electric grid is discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The main objective was to study the treatment of wastewater generated by the oil industry. This work consisted of tests of electroflocculation with alternate current (AC), and chemical coagulation. The removal efficiencies of organic load were evaluated by the removal of oils and greases, color and turbidity. The parameters investigated were the change in alternate current frequency, the initial pH, the distance between electrodes, the applied potential and time lapse. From the results, one may conclude that the electroflocculation process is potential applicability to the effluent studied, while chemical coagulation was not successful.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Este artigo apresenta os principais resultados e o detalhamento da metodologia e equações de controle de um retificador monofásico pré-regulador de 150kW para sistema trólebus. A estrutura proposta possibilita a Correção ativa do Fator de Potência (CFP) com baixos níveis de Distorção Harmônica Total (DHT) na corrente, em conformidade com a norma internacional IEC 61000-3-4. Fruto de um projeto de Pesquisa, Desenvolvimento e Inovação (P) junto à empresa AES Eletropaulo Metropolitana de São Paulo, em parceria com a empresa de transporte Himalaia S.A., o projeto possui como principais objetivos estimular o interesse para a expansão das linhas de trólebus a partir de uma plataforma de alimentação de menor custo de instalação e manutenção, sem a necessidade de subestações retificadoras, e, com vistas a promover a melhoria da qualidade de vida nos grandes centros urbanos. Nessa nova modalidade proposta para o sistema de alimentação, o trólebus pode ser alimentado tanto pelas redes convencionais em corrente contínua (CC) quanto pelas redes de distribuição em corrente alternada (CA), mantendo-se a disposição a dois fios dos sistemas CC, sendo as mudanças de rede de alimentação (CC ou CA) monitoradas e controladas digitalmente. Todo o sistema de gerenciamento e controle do conversor é realizado digitalmente por FPGA XC3S200. Na evolução do sistema proposto, os autores pretendem inclusive eliminar as linhas aéreas de alimentação, através da utilização de postos de alimentação em CA, especialmente desenvolvidos para os pontos de embarque/desembarque de passageiros para este veículo de transporte coletivo, eliminando-se os aspectos visuais negativos das redes de alimentação deste modal, e, reduzindo-se as falhas de operação do sistema.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

RACIONAL: Fato de observação não rara, é o encontro de refluxo cecoileal durante realização de enema opaco. As causas e conseqüências deste achado têm sido pouco estudadas. OBJETIVOS: Sabendo que a junção ileocecal exerce função de barreira e proteção contra a invasão do delgado pela flora colônica, realizou-se o presente estudo com a finalidade de investigar se existe contaminação ileal em indivíduos com refluxo cecoileal ao enema opaco. MÉTODOS: Investigaram-se 36 indivíduos, 30 mulheres e 6 homens, idade média de 54 anos, 25 com e 11 com ausência refluxo cecoileal. Todos submetidos a pesquisa de contaminação bacteriana do delgado por intermédio de teste respiratório com lactulose-H2 e a determinação do tempo de trânsito orocecal por meio de biossusceptometria de corrente alternada. A caracterização da contaminação do delgado foi baseada no encurtamento do tempo de trânsito orocecal medido pelo teste da lactulose-H2. RESULTADOS: A comparação dos valores basais do H2, do tempo de trânsito orocecal-H2 e tempo de trânsito orocecal-biossusceptometria de corrente alternada não diferiram estatisticamente entre os grupos com e sem refluxo cecoileal. Quando comparados os tempo de trânsito orocecal-H2 e tempo de trânsito orocecal-biossusceptometria, foi observado aumento de tendência de redução do primeiro em relação ao último nos grupos com refluxo cecoileal e correlação significante entre os dois métodos apenas no grupo-controle, inexistindo nos com refluxo cecoileal. CONCLUSÃO: Encurtamento do tempo de trânsito orocecal-H2 e sua perda de correlação com o tempo de trânsito orocecal-biossusceptometria observado em indivíduos com refluxo cecoileal, sugerem comportamento diferenciado deste grupo em relação ao grupo-controle. Possível explicação para as diferenças registradas entre os grupos, seria a presença de flora anômala nos indivíduos com refluxo cecoileal.