Resumo:
Tesis inédita presentada en la Universidad Europea de Madrid. Facultad de Arquitectura, Ingeniería y Diseño. Programa de Doctorado en Técnicas Avanzadas en Construcción
Resumo:
La fachada es la parte visible de un edificio que en general consta de diferentes sistemas constructivos. El índice de reducción acústica del cerramiento del hueco de la fachada de un recinto es determinante en el aislamiento acústico a ruido aéreo de la fachada del mismo. Una ventana es la parte transparente de la fachada y para mejorar su comportamiento térmico y controlar la radiación solar, se ha equipado con diferentes protecciones externas o internas, como por ejemplo las contraventanas, celosías, persianas, etc. En este trabajo se muestran los resultados experimentales de varias decenas de ensayos realizados, de las mediciones in situ del aislamiento acústico a ruido aéreo de las fachadas de recintos mediante la aplicación de la Norma UNE-EN ISO 140-5:1999. En cada uno de los recintos, los ensayos acústicos se han realizado en dos situaciones, con y sin protección solar. Posteriormente se ha analizado el comportamiento acústico de cada una de las protecciones solares.
Resumo:
En este trabajo se comparan los resultados experimentales de las mediciones in situ del aislamiento acústico al ruido aéreo de fachadas de recintos, por aplicación en cada uno de los recintos de dos métodos globales de la Norma EN ISO 140-5, Agosto 1998. Se han utilizado como fuentes de ruido un altavoz y el ruido de aeronaves. Las mediciones acústicas se han realizado en 26 dormitorios situados en viviendas de uso residencial privado.
Resumo:
Se muestran los resultados de las mediciones in situ del aislamiento a ruido aéreo y del aislamiento acústico de suelos al ruido de impactos entre varias decenas de locales superpuestos, mediante aplicación de las Normas UNE-EN ISO 140-4: Medición in situ del aislamiento a ruido aéreo entre locales y UNE-EN ISO 140-7: Medición in situ del aislamiento acústico de suelos al ruido de impactos. Las magnitudes globales del aislamiento a ruido aéreo y a ruido de impactos se han obtenido por dos procedimientos: en dB(A) y mediante la aplicación de las Normas EN ISO 717-1 y EN ISO 717-2. Posteriormente se deducen varias relaciones entre las magnitudes medidas.
Resumo:
Se comprueba la mejora en el aislamiento acústico entre recintos de la colocación de una capa de arean entre el solado y el forjado
Resumo:
Se estudia el efecto de la colocación de sistemas de aireación permanente en la ventana en su aislamiento a ruido aéreo.
Resumo:
Actualmente son una práctica común los procesos de normalización de métodos de ensayo y acreditación de laboratorios, ya que permiten una evaluación de los procedimientos llevados a cabo por profesionales de un sector tecnológico y además permiten asegurar unos mínimos de calidad en los resultados finales. En el caso de los laboratorios de acústica, para conseguir y mantener la acreditación de un laboratorio es necesario participar activamente en ejercicios de intercomparación, utilizados para asegurar la calidad de los métodos empleados. El inconveniente de estos ensayos es el gran coste que suponen para los laboratorios, siendo en ocasiones inasumible por estos teniendo que renunciar a la acreditación. Este Proyecto Fin de Grado se centrará en el desarrollo de un Laboratorio Virtual implementado mediante una herramienta software que servirá para realizar ejercicios de intercomparación no presenciales, ampliando de ese modo el concepto e-comparison y abriendo las bases a que en un futuro este tipo de ejercicios no presenciales puedan llegar a sustituir a los llevados a cabo actualmente. En el informe primero se hará una pequeña introducción, donde se expondrá la evolución y la importancia de los procedimientos de calidad acústica en la sociedad actual. A continuación se comentará las normativas internacionales en las que se soportará el proyecto, la norma ISO 145-5, así como los métodos matemáticos utilizados en su implementación, los métodos estadísticos de propagación de incertidumbres especificados por la JCGM (Joint Committee for Guides in Metrology). Después, se hablará sobre la estructura del proyecto, tanto del tipo de programación utilizada en su desarrollo como la metodología de cálculo utilizada para conseguir que todas las funcionalidades requeridas en este tipo de ensayo estén correctamente implementadas. Posteriormente se llevará a cabo una validación estadística basada en la comparación de unos datos generados por el programa, procesados utilizando la simulación de Montecarlo, y unos cálculos analíticos, que permita comprobar que el programa funciona tal y como se ha previsto en la fase de estudio teórico. También se realizará una prueba del programa, similar a la que efectuaría un técnico de laboratorio, en la que se evaluará la incertidumbre de la medida calculándola mediante el método tradicional, pudiendo comparar los datos obtenidos con los que deberían obtenerse. Por último, se comentarán las conclusiones obtenidas con el desarrollo y pruebas del Laboratorio Virtual, y se propondrán nuevas líneas de investigación futuras relacionadas con el concepto e-comparison y la implementación de mejoras al Laboratorio Virtual. ABSTRACT. Nowadays it is common practise to make procedures to normalise trials methods standards and laboratory accreditations, as they allow for the evaluation of the procedures made by professionals from a particular technological sector in addition to ensuring a minimum quality in the results. In order for an acoustics laboratory to achieve and maintain the accreditation it is necessary to actively participate in the intercomparison exercises, since these are used to assure the quality of the methods used by the technicians. Unfortunately, the high cost of these trials is unaffordable for many laboratories, which then have to renounce to having the accreditation. This Final Project is focused on the development of a Virtual Laboratory implemented by a software tool that it will be used for making non-attendance intercomparison trials, widening the concept of e-comparison and opening the possibility for using this type of non-attendance trials instead of the current ones. First, as a short introduction, I show the evolution and the importance today of acoustic quality procedures. Second, I will discuss the international standards, such as ISO 145-5, as well the mathematic and statistical methods of uncertainty propagation specified by the Joint Committee for Guides in Metrology, that are used in the Project. Third, I speak about the structure of the Project, as well as the programming language structure and the methodology used to get the different features needed in this acoustic trial. Later, a statistical validation will be carried out, based on comparison of data generated by the program, processed using a Montecarlo simulation, and analytical calculations to verify that the program works as planned in the theoretical study. There will also be a test of the program, similar to one that a laboratory technician would carry out, by which the uncertainty in the measurement will be compared to a traditional calculation method so as to compare the results. Finally, the conclusions obtained with the development and testing of the Virtual Laboratory will be discussed, new research paths related to e-comparison definition and the improvements for the Laboratory will be proposed.
Resumo:
El aislamiento acústico depende de las particiones que separan los recintos, de las transmisiones indirectas y de los posibles errores de ejecución. Respecto a las transmisiones indirectas, éstas pueden controlarse con un diseño riguroso de las uniones y una buena puesta en obra. Este trabajo muestra la influencia que tiene el diseño de las uniones en el aislamiento acústico medido in situ, específicamente de las uniones entre las particiones y la fachada de dos hojas. Simulando una obra nueva, en un laboratorio se han realizado distintos montajes de particiones, se han trasdosado con paredes cerámicas con bandas y se ha modificado el diseño de la unión entre la fachada y las particiones. Para cada uno de los montajes se ha realizado un ensayo de aislamiento acústico. Las diferencias encontradas entre cada una de las diferentes configuraciones ensayadas llegan a los 9 dB.
Resumo:
El objetivo lógico de toda intervención en los edificios existentes debe ser la mejora progresiva de las condiciones de la edificación para adaptarla a estándares de calidad actuales. En este sentido, la parte I del CTE aprobada en 2013 establece que debe aplicarse el CTE a las obras en edificios existentes, y se dan dos criterios generales: El criterio de flexibilidad, que permite adecuar la actuación al mayor grado de aproximación a las prestaciones del CTE cuando la intervención sea urbanística, técnica y económicamente inviable o no sea compatible con el grado de protección del edificio, y el criterio de no empeoramiento, que no permite rebajar las condiciones existentes. El objetivo de esta ponencia es ahondar en los fundamentos de dichos criterios, y mostrar un procedimiento para la fase de proyecto cuyo fin es mejorar el aislamiento acústico en los edificios existentes y orientar a los proyectistas sobre los niveles de aislamiento que pueden obtenerse según el tipo de intervención.
Resumo:
El incremento de la contaminación acústica se ha convertido en un problema medioambiental lo cual ha generado un aumento en la demanda del aislamiento de los edificios para lograr el confort acústico. Existen métodos de medición de aislamiento acústico a ruido aéreo de fachadas bajo ensayo “in situ” pero no para techos. El objetivo de esta investigación consiste en determinar el aislamiento acústico de prototipos de techos ecológicos multicapas adaptando la metodología recomendada por normas internacionales. Se propusieron cuatro prototipos de techos con distintos materiales naturales como especies vegetales y sustratos de fibra de coco, superpuestos sobre un techo base liviano. Al sustrato se le varió su espesor de 10 a 20 cm, sus condiciones seca o húmeda y su densidad: 100%, 66% y 33% fibra de coco. En los resultados se determinó que las especies vegetales no aportaron aislamiento, pero al incrementar el espesor y densidad del sustrato mejoró el aislamiento sonoro. También se determinó que el aislamiento acústico en condición seca fue mejor que en condición húmeda. Se planteó una metodología para determinar el aislamiento acústico a ruido aéreo en techos bajo ensayo “in situ” empleando el método global con altavoz, ésta se estructuró en tres partes: la primera describe el módulo experimental y la plataforma tecnológica; la segunda aborda procedimientos para medir los niveles de presión sonora, niveles de ruido de fondo y los tiempos de reverberación, en bandas de frecuencia de tercios de octava; en la tercera se explica el cálculo de los promedios de estos parámetros, así como también la diferencia de niveles estandarizada, el índice de reducción sonora aparente con sus valores globales y su incertidumbre. Así mismo, se determinó un algoritmo de predicción del aislamiento acústico, analizando los valores obtenidos en las mediciones “in situ” como la Diferencia de nivel estandarizada ponderada y el Índice ponderado de reducción sonora, los cuales se relacionaron con el peso y el espesor de los materiales de las diferentes multicapas. A través de un análisis de regresión se establecieron modelos para predecir la Diferencia de nivel estandarizada y el Índice de reducción sonora aparente en bandas de octavas. Los resultados del modelo propuesto son cercanos a los datos medidos “in situ”. Por otra parte, se realizaron mediciones térmicas en un módulo experimental y otro de referencia en tres períodos del día. En el módulo experimental se construyeron los prototipos de techos ecológicos y en el de referencia un techo de construcción tradicional, se compararon los resultados de ambos módulos y su interacción con la temperatura exterior. Se detectó que las temperaturas internas del módulo experimental en condición seca tienden a mantener sus valores durante todo el día, en horas de la mañana sus valores son superiores a los del módulo de referencia y temperatura exterior. Al mediodía y en la tarde las temperaturas internas del módulo experimental son inferiores a las del módulo de referencia, incrementándose esta última a medida que aumenta temperatura exterior. Finalmente, a partir de las mediciones “in situ” se realizaron cuatro modelos de correlación acústica-térmica, los tres primeros relacionando la temperatura y el nivel de presión sonora en tres momentos del día, en la tarde se aprecia que a medida que aumenta la temperatura aumentan los niveles de presión sonora. En el cuarto modelo se estableció una correlación acústica-térmica entre la resistencia térmica de los materiales de las multicapas con su índice de reducción sonora, obteniéndose un coeficiente de correlación moderado. La presente investigación plantea retos desde el punto de vista ambiental, permite cuantificar el aislamiento acústico de los techos y mejorar la calidad de vida en áreas urbanas; el empleo de los materiales de procedencia local como los utilizados fomenta el respeto por la naturaleza y producen un menor impacto ambiental. ABSTRACT Sound contamination increase has generated a raise in insulation demand of buildings in order to achieve a sound comfort, and this has become into an environmental problem. There are measurements methods for air borne soundproofing in facades through “in situ” test but there are not for roofs. The purpose of this research is to determine sound insulation of multilayer green roof prototypes following the methodology suggested by international standards. Four prototypes of roofs with different types of vegetation and overlapped coconut fiber substrates over a light roof were proposed. Thickness of substrate varied from 10 to 20 cm, as well as its dry a humid condition and its density: 100%, 66% y 33% of coconut fiber. Results determined that vegetation did not contribute to insulation but when increasing substrate’s thickness and density, sound insulation was improved. Likewise, it was determined that sound insulation in dry condition was greater than in humid condition. A methodology to determine airborne sound insulation in roofs through “in situ” test using a speaker global method was stated. This was structured in three parts: the first part describes the experimental module and the technological platform; the second one establishes the procedures to measure sound pressure levels; levels of background noise and time of reverberation in frequency bands of thirds of octave, and in the third part, averages of these parameters, as well as the difference of standardized levels, the apparent sound reduction with its global values and uncertainty were calculated. Likewise, a prediction algorithm of sound insulation was determined by analyzing values obtained in “in-situ” measures such as the difference of weighted standardized level and the weighted index of sound reduction which they were related to weight and thickness of different multilayer materials. Models to predict the standardized level difference and the apparent sound reduction index in bands of octaves were established by a regression analysis. Results for the proposed model are close to data measured “in situ”. On the other hand, thermal measures were done in an experimental module, as well as in another as for reference in three periods of the day. Green prototypes roofs were built in the experimental module and a traditional roof were built in the reference one. Results of both modules were compared as well as the interaction with outside temperature. Internal temperatures of the experimental module in dry condition tend to keep their values throughout the day; in the morning, its values are higher than those of the reference module and external temperatures. Finally, four models of sound-thermal correlation were done from measures “in situ”. The first three were related to temperature and sound pressure level in three moments of the day. In the afternoon, it is observed that when temperature increases, sound pressure levels increases too. In the fourth model, a sound and thermal correlation was established between thermal resistance of multilayer materials with their sound reduction index, and a moderated correlation coefficient was obtained. This research poses challenges from the environmental point of view, and it allows quantifying sound insulation of roofs as well as improving quality of life in urban areas; the use of local vegetation promotes respect for nature and it produces a smaller environmental impact as well.
Resumo:
Esta investigación aborda el estudio de la influencia de las uniones en el aislamiento acústico a ruido aéreo en los edificios y el análisis de las transmisiones indirectas producidas en particiones de dos hojas de ladrillo cerámico sobre bandas elásticas. La transmisión de ruido entre dos recintos separados por una partición se produce por dos vías: La vía directa a través del elemento que separa los dos recintos y la vía indirecta, a través de los elementos de flanco, como forjados, particiones, fachadas, etc. que conectados a dicho elemento de separación, vibran en presencia del campo acústico transmitiendo sus vibraciones al recinto receptor. Si las transmisiones indirectas son dominantes, el aislamiento acústico “in situ” puede ser menor que el esperado. El parámetro que expresa la atenuación acústica en las uniones es el índice de reducción vibracional en la unión o Kij. Éste parámetro se utiliza en los métodos de cálculo del aislamiento acústico a ruido aéreo, que permiten la justificación del cumplimiento de la normativa actual, el Documento Básico DB HR Protección frente al ruido del CTE. La determinación de los índices Kij de las uniones es una cuestión que debe abordarse de forma experimental. Existen diferentes expresiones empíricas obtenidas en varios laboratorios europeos que permiten el cálculo del índice Kij, pero no se han validado con ensayos realizados en soluciones habituales en la construcción española, como las estudiadas en este trabajo. El objetivo de este trabajo es la medida, análisis y cuantificación de las transmisiones indirectas producidas en las uniones de elementos de dos hojas de fábrica de ladrillo cerámico. Se ha recurrido a una campaña de ensayos en la que se reproducían las condiciones de un edificio real y se ha medido el aislamiento acústico a ruido aéreo y los índices Kij de diferentes configuraciones de uniones. Del análisis de los resultados, se demuestra que el aislamiento acústico a ruido aéreo depende de las uniones, pudiéndose obtener mejoras significativas al variar la forma de unión entre los elementos constructivos. Las mejoras de aislamiento acústico están relacionadas con un buen diseño de las uniones y con valores elevados del índice Kij. Este trabajo aporta valores experimentales de Kij para soluciones de fábrica de ladrillo y pone en discusión los valores teóricos que actualmente aparecen en la normativa vigente. ABSTRACT This research work deals with the effects of junction construction details on airborne sound insulation in buildings and the analysis of flanking transmissions across double ceramic brick walls with elastic interlayers. The sound transmission between two adjacent rooms comprises two paths: the direct path, caused by the incident sound on a separating wall, and the indirect path, through flanking elements connected to the separating wall, such as floors, internal walls, ceilings, etc. Flanking elements vibrate when excited in the sound field, thus transferring sound via structure borne to the receiving room. Dominant flanking transmissions can decrease the field sound insulation performance of the building. The vibration reduction index, Kij. expresses the acoustic attenuation of construction joints. This is an input parameter in the calculation models designed to estimate the airborne sound insulation between adjoining rooms in buildings. These models are used to comply with the acoustic requirements set by Basic Document DB HR Protection against noise included in the Spanish Building Code. The characterization of Kij. must be addressed experimentally by means of measurements. The available empirical Kij. formulae were developed in different European laboratories, but they have not been validated with standard tests performed on common Spanish walls, such as those studied in this work. The aim of this work is the measurement, analysis and quantification of indirect transmissions though joints of double ceramic brick walls. Airborne sound insulation tests and Kij measurements were performed in a laboratory which emulated the conditions of a real building. These tests were performed in different partitions whose joints were modified. It follows from the analysis of the results that airborne sound insulation depends strongly on the design of joints. Sound insulation improves when the joints between construction elements are modified to eliminate acoustic bridges. The increase in sound insulation corresponds to best practice design of joints and to high Kij values. This research work provides experimental Kij data of double ceramic brick walls and the results put in discussion the theoretical values set in the current Standards.
Resumo:
La principal aportación del trabajo es la formulación de una alternativa que facilita la determinación experimental del factor de pérdidas y, en consecuencia, mejorar las predicciones de aislamiento a ruido aéreo para vidrios con una o más capas intermedias sea cual fuere su naturaleza. Además, se realiza una revisión de las normativas relacionadas con los ensayos de los parámetros mecánicos necesarios para la caracterizar los vidrios, centrándonos en los monolíticos y los laminados. En efecto, uno de los problemas que se plantea en el contexto de la acústica de la edificación actualmente es el de cumplir con los requisitos de aislamiento acústico a ruido aéreo en fachada que exige el vigente Código Técnico de la Edificación (CTE). Como sabemos, en la fachada podemos distinguir la parte ciega y la parte hueca. La parte más débil en lo concerniente a aislamiento a ruido aéreo es la hueca (compuesta por el vidrio, carpintería y otros elementos). Si la carpintería es la adecuada, la superficie de vidrio se convierte en el elemento limitante. El Catálogo de Elementos Constructivos (CEC) del CTE, la propia norma UNE-EN 12758:2011, así como algunos, cada vez más, fabricantes ofrecen datos del aislamiento de vidrios simples, vidrios laminados y vidrios dobles. En el caso de vidrios laminados, estos datos se limitan únicamente en los que tienen un sola lámina intermedia y, además, no acústicos. Podemos hablar, por tanto, de una laguna de información en este sentido. Para obtener predicciones fiables de aislamiento acústico a ruido aéreo de particiones multicapa, como pueden ser los vidrios laminados es necesario disponer de las características mecánicas y una de las más relevantes es el factor de pérdidas.
Resumo:
El aislamiento acústico es un problema de difícil solución una vez que la obra ya está acabada. En el caso de que la obra esté finalizada y no se cumplan con los valores de calidad acústicos que nos marca la legislación, deben detectarse los puntos débiles que provocan esa deficiencia de aislamiento acústico. La publicación de catálogos de soluciones constructivas hace que el problema no sea el material elegido, sino cómo se han unido estos materiales entre sí. Por tanto, debe analizarse este problema y buscar mecanismos con los que determinar los puntos débiles. En este trabajo se propone un método para la determinación de caminos débiles de transmisión entre un recinto emisor y un recinto receptor. El método obtiene el índice de reducción vibracional, como indicador de estos caminos débiles. Se muestran en el trabajo varios casos estudiados en el propio edificio, y cómo valorar la transmisión que debilita el aislamiento global de todo el conjunto constructivo.
Resumo:
Los sistemas de fachadas multicapas ligeras presentan características favorables respecto al ahorro en el consumo energético, ya que presentan un excelente comportamiento térmico. Sin embargo, desde el punto de vista acústico, en general han sido poco estudiados. Los primeros datos que se tienen es que no suelen alcanzar los valores de aislamiento acústico requeridos en el Código Técnico de la Edificación (CTE) en entornos especialmente ruidosos. Por lo tanto, los objetivos principales de esta investigación son obtener sistemas de fachadas multicapas ligeras con un alto grado de aislamiento acústico, que puedan ser empleados en entornos ruidosos. Al mismo tiempo que presenten excelentes características térmicas, sin descuidar aspectos tan importantes como la sostenibilidad de los materiales, la industrialización, los costes, entre otros. En este artículo se explicará el proceso que se ha llevado a cabo para realizar una investigación relacionada con el comportamiento acústico de fachadas multicapas ligeras. Para ello se han empleado los métodos de medida del comportamiento acústico a ruido aéreo e intensimetría sonora. Una vez obtenidos estos resultados se realiza una comparativa entre las fachadas multicapas ligeras y las fachadas tradicionales.
Resumo:
Actualmente en el mercado existen una reducida variedad de materiales específicos de ruido de impactos. Los materiales que han de ser utilizados como material resiliente, han de cumplir unos valores muy bajos del módulo de elasticidad E. Mientras el valor del caucho blando está en el orden de los 100 kg/cm2, el valor del acero es de 2.100.000 kg/cm2 (21.000 veces mayor). Estos valores tan bajos hacen que diferencias de apenas 50 kg/cm2 produzcan variaciones muy importantes en las ganancias de aislamiento acústico. La realización de los ensayos de caracterización acústica a ruido de impacto en laboratorio es un proceso largo y caro. En primer lugar se necesita elaborar un forjado de referencia, que ha de ser ensayado de forma independiente. Con posterioridad, se ha de colocar la losa flotante, y volver a realizar la prueba. Con la diferencia de las medidas realizadas, se determinan los valores de módulo de elasticidad. Como alternativa a este método, en la ponencia del congreso “TECNIACÚSTICA GANDÍA 2006” sobre “estudio de cinco métodos para determinar las propiedades dinámicas de capas elásticas para la mejora del aislamiento a ruido de impactos”, presentada por Francisco Simón, David K. Anthony, Mª José Fernández, proponen un total de cinco alternativas al ensayo indicado en la norma. Al margen de las condiciones acústicas, las placas de suelo radiante necesitan garantizar unos valores mínimos de aislamiento térmico. Con las actuales necesidades normativas, la solución habitual consiste en la superposición de dos materiales: en primer lugar, inmediatamente sobre el forjado, se coloca el material encargado de proporcionar el aislamiento acústico, generalmente una lámina flexible de polietileno. Encima de ella se coloca la placa de aislamiento térmico, generalmente una plancha de poliestireno expandido con resaltes en las que se encajan las tuberías que conducen el agua calefactada. El poliestireno expandido convencional, no tiene unos valores de módulo elástico suficientemente bajo para poder actuar como material resiliente. Para conseguir estos valores, es necesario elastificar el material mediante su introducción en una prensa (Poliestireno expandido elastificado EEPS). La utilización de esta técnica es incompatible con el proceso de fabricación de planchas moldeadas con tetones para la integración de los soportes de las tuberías. La lámina flexible de polietileno, si tienes valores aceptables, tanto de aislamiento térmico como acústico, en cambio no es posible la integración de los tetones durante su proceso de fabricación para soportar las canalizaciones de agua. El objetivo de la investigación consiste en integrar en una única placa las características tanto térmicas como acústicas necesarias para satisfacer todas las necesidades. Como se ha indicado más arriba, los materiales resilientes han de cumplir unos valores muy bajos del módulo de elasticidad E. Mientras el valor del caucho blando está en el orden de los 100 kg/cm2, el valor del acero es de 2.100.000 kg/cm2 (21.000 veces mayor). Pero no es menos cierto que con acero, dando la forma adecuada (un helicoide) se consigue un elemento muy elástico, un muelle. Tal es así, que variando la forma se puede conseguir el módulo de elásticidad E deseado, resultando utilidades tan dispares como el resorte de un bolígrafo o la suspensión de un coche. Por otro lado, y como se ha indicado anteriormente, la determinación de los valores mecánicos de los materiales aislantes térmicos es cara y complicada. Como objetivo secundario de la investigación, se establece el proponer un ensayo alternativo, más rápido y económico que el propuesto por la norma para facilitar el estudio de nuevas alternativas, sin tener que hacer grandes desembolsos económicos en