978 resultados para Air quality Standards Indonesia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Because of the scientific evidence showing that arsenic (As), cadmium (Cd), and nickel (Ni) are human genotoxic carcinogens, the European Union (EU) recently set target values for metal concentration in ambient air (As: 6 ng/m3, Cd: 5 ng/m3, Ni: 20 ng/m3). The aim of our study was to determine the concentration levels of these trace elements in Porto Metropolitan Area (PMA) in order to assess whether compliance was occurring with these new EU air quality standards. Fine (PM2.5) and inhalable (PM10) air particles were collected from October 2011 to July 2012 at two different (urban and suburban) locations in PMA. Samples were analyzed for trace elements content by inductively coupled plasma–mass spectrometry (ICP-MS). The study focused on determination of differences in trace elements concentration between the two sites, and between PM2.5 and PM10, in order to gather information regarding emission sources. Except for chromium (Cr), the concentration of all trace elements was higher at the urban site. However, results for As, Cd, Ni, and lead (Pb) were well below the EU limit/target values (As: 1.49 ± 0.71 ng/m3; Cd: 1.67 ± 0.92 ng/m3; Ni: 3.43 ± 3.23 ng/m3; Pb: 17.1 ± 10.1 ng/m3) in the worst-case scenario. Arsenic, Cd, Ni, Pb, antimony (Sb), selenium (Se), vanadium (V), and zinc (Zn) were predominantly associated to PM2.5, indicating that anthropogenic sources such as industry and road traffic are the main source of these elements. High enrichment factors (EF > 100) were obtained for As, Cd, Pb, Sb, Se, and Zn, further confirming their anthropogenic origin.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Under the Clean Air Act, Congress granted discretionary decision making authority to the Administrator of the Environmental Protection Agency (EPA). This discretionary authority involves setting standards to protect the public's health with an "adequate margin of safety" based on current scientific knowledge. The Administrator of the EPA is usually not a scientist, and for the National Ambient Air Quality Standard (NAAQS) for particulate matter (PM), the Administrator faced the task of revising a standard when several scientific factors were ambiguous. These factors included: (1) no identifiable threshold below which health effects are not manifested, (2) no biological basis to explain the reported associations between particulate matter and adverse health effects, and (3) no consensus among the members of the Clean Air Scientific Advisory Committee (CASAC) as to what an appropriate PM indicator, averaging period, or value would be for the revised standard. ^ This project recommends and demonstrates a tool, integrated assessment (IA), to aid the Administrator in making a public health policy decision in the face of ambiguous scientific factors. IA is an interdisciplinary approach to decision making that has been used to deal with complex issues involving many uncertainties, particularly climate change analyses. Two IA approaches are presented; a rough set analysis by which the expertise of CASAC members can be better utilized, and a flag model for incorporating the views of stakeholders into the standard setting process. ^ The rough set analysis can describe minimal and maximal conditions about the current science pertaining to PM and health effects. Similarly, a flag model can evaluate agreement or lack of agreement by various stakeholder groups to the proposed standard in the PM review process. ^ The use of these IA tools will enable the Administrator to (1) complete the NAAQS review in a manner that is in closer compliance with the Clean Air Act, (2) expand the input from CASAC, (3) take into consideration the views of the stakeholders, and (4) retain discretionary decision making authority. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To assess the indoor environment of two different types of dental practices regarding VOCs, PM2.5, and ultrafine particulate concentrations and examine the relationship between specific dental activities and contaminant levels. Method: The indoor environments of two selected dental settings (private practice and community health center) will were assessed in regards to VOCs, PM 2.5, and ultrafine particulate concentrations, as well as other indoor air quality parameters (CO2, CO, temperature, and relative humidity). The sampling duration was four working days for each dental practice. Continuous monitoring and integrated sampling methods were used and number of occupants, frequency, type, and duration of dental procedures or activities recorded. Measurements were compared to indoor air quality standards and guidelines. Results: The private practice had higher CO2, CO, and most VOC concentrations than the community health center, but the community health center had higher PM2.5 and ultrafine PM concentrations. Concentrations of p-dichlorobenzene and PM2.5 exceeded some guidelines. Outdoor concentrations greatly influenced the indoor concentration. There were no significant differences in contaminant levels between the operatory and general area. Indoor concentrations during the working period were not always consistently higher than during the nonworking period. Peaks in particulate matter concentration occurred during root canal and composite procedures.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

When ambient air quality standards established in the EU Directive 2008/50/EC are exceeded, Member States are obliged to develop and implement Air Quality Plans (AQP) to improve air quality and health. Notwithstanding the achievements in emission reductions and air quality improvement, additional efforts need to be undertaken to improve air quality in a sustainable way - i.e. through a cost-efficiency approach. This work was developed in the scope of the recently concluded MAPLIA project "Moving from Air Pollution to Local Integrated Assessment", and focuses on the definition and assessment of emission abatement measures and their associated costs, air quality and health impacts and benefits by means of air quality modelling tools, health impact functions and cost-efficiency analysis. The MAPLIA system was applied to the Grande Porto urban area (Portugal), addressing PM10 and NOx as the most important pollutants in the region. Four different measures to reduce PM10 and NOx emissions were defined and characterized in terms of emissions and implementation costs, and combined into 15 emission scenarios, simulated by the TAPM air quality modelling tool. Air pollutant concentration fields were then used to estimate health benefits in terms of avoided costs (external costs), using dose-response health impact functions. Results revealed that, among the 15 scenarios analysed, the scenario including all 4 measures lead to a total net benefit of 0.3M€·y(-1). The largest net benefit is obtained for the scenario considering the conversion of 50% of open fire places into heat recovery wood stoves. Although the implementation costs of this measure are high, the benefits outweigh the costs. Research outcomes confirm that the MAPLIA system is useful for policy decision support on air quality improvement strategies, and could be applied to other urban areas where AQP need to be implemented and monitored.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Indoor Air Quality (IAQ) can have significant implications for health, productivity, job performance, and operating cost. Professional experience in the field of indoor air quality suggests that high expectations (better than nationally established standards) (American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE)) of workplace indoor air quality lead to increase air quality complaints. To determine whether there is a positive association between expectations and indoor air quality complaints, a one-time descriptive and analytical cross-sectional pilot study was conducted. Area Safety Liaisons (n = 330) at University of Texas Health Science Center – Houston were asked to answer a questionnaire regarding their expectations of four workplace indoor air quality indicators i.e., (temperature, relative humidity, carbon dioxide, and carbon monoxide) and if they experienced and reported indoor air quality problems. A chi-square test for independence was used to evaluate associations among the variables of interest. The response rate was 54% (n = 177). Results did not show significant associations between expectation and indoor air quality. However, a greater proportion of Area Safety Liaisons who expected indoor air quality indicators to be better than the established standard experienced greater indoor air quality problems. Similarly, a slightly higher proportion of Area Liaisons who expected indoor air quality indicators to be better than the standard reported greater indoor air quality complaints. ^ The findings indicated that a greater proportion of Area Safety Liaisons with high expectations (conditions that are beyond what is considered normal and acceptable by ASHRAE) experienced greater indoor air quality discomfort. This result suggests a positive association between high expectations and experienced and reported indoor air quality complaints. Future studies may be able to address whether the frequency of complaints and resulting investigations can be reduced through information and education about what are acceptable conditions.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To maintain a competitive development of the Brazilian aviculture, some measures must be taken to enable the identification and reduction of risks to the health of birds, as well as for the physical environment. Therefore, the aim of this study was to evaluate the effectiveness of three different systems of minimum ventilation (positive pressure - SVMP, negative pressure - SVMN and natural ventilation - SVMNat) in the air quality during the first 21 days of life of broiler chicks, during winter. Three points were selected along the length to verify ammonia, carbon monoxide and oxygen concentrations at 3a.m., 9a.m., 3p.m. and 9p.m., by the respiration level of birds and workers. The averages of pollutant gases did not exceed the tolerance levels for the three minimum ventilation systems evaluated, which is 20 and 10ppm for the birds level and 20 and 39ppm for the workers level, for ammonia and carbon monoxide, respectively. It was evident that the minimum ventilation systems were appropriately sized for the required minimum ambient air renovation, in respect to ventilation rates applied for the SVMN and SVMP systems, and with air velocity at levels that do not stress the chicks, including for the SVMNat. The three studied systems of minimum ventilation allowed the birds to externalize their productive performance, with values close to the ones considered satisfactory for all evaluated parameters, in accordance with the Brazilian aviculture standards.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article addresses the need for providing good standards of indoor air quality (IAQ) in buildings from the view point of health, well-being and productivity of building occupants. It briefly outlines the role of ventilation in achieving the required IAQ targets and discusses the performance of different types of ventilation systems in use. As a result of new energy efficiency directives and legislations in Europe and elsewhere, the ventilation energy component of HVAC systems has increased in relative terms and this article introduces a method for evaluating the performance air distribution systems that is based on ventilation and energy effectiveness. A range of ventilation systems are discussed, including mechanical and natural ventilation, and results for more recently developed mechanical air distribution systems are compared with conventional systems. The article provides an assessment and comparison of some of these systems with reference to ventilation performance and energy efficiency

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Modeling is an essential tool for the development of atmospheric emission abatement measures and air quality plans. Most often these plans are related to urban environments with high emission density and population exposure. However, air quality modeling in urban areas is a rather challenging task. As environmental standards become more stringent (e.g. European Directive 2008/50/EC), more reliable and sophisticated modeling tools are needed to simulate measures and plans that may effectively tackle air quality exceedances, common in large urban areas across Europe, particularly for NO2. This also implies that emission inventories must satisfy a number of conditions such as consistency across the spatial scales involved in the analysis, consistency with the emission inventories used for regulatory purposes and versatility to match the requirements of different air quality and emission projection models. This study reports the modeling activities carried out in Madrid (Spain) highlighting the atmospheric emission inventory development and preparation as an illustrative example of the combination of models and data needed to develop a consistent air quality plan at urban level. These included a series of source apportionment studies to define contributions from the international, national, regional and local sources in order to understand to what extent local authorities can enforce meaningful abatement measures. Moreover, source apportionment studies were conducted in order to define contributions from different sectors and to understand the maximum feasible air quality improvement that can be achieved by reducing emissions from those sectors, thus targeting emission reduction policies to the most relevant activities. Finally, an emission scenario reflecting the effect of such policies was developed and the associated air quality was modeled.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As environmental standards become more stringent (e.g. European Directive 2008/50/EC), more reliable and sophisticated modeling tools are needed to simulate measures and plans that may effectively tackle air quality exceedances, common in large cities across Europe, particularly for NO2. Modeling air quality in urban areas is rather complex since observed concentration values are a consequence of the interaction of multiple sources and processes that involve a wide range of spatial and temporal scales. Besides a consistent and robust multi-scale modeling system, comprehensive and flexible emission inventories are needed. This paper discusses the application of the WRF-SMOKE-CMAQ system to the Madrid city (Spain) to assess the contribution of the main emitting sectors in the region. A detailed emission inventory was compiled for this purpose. This inventory relies on bottom-up methods for the most important sources. It is coupled with the regional traffic model and it makes use of an extensive database of industrial, commercial and residential combustion plants. Less relevant sources are downscaled from national or regional inventories. This paper reports the methodology and main results of the source apportionment study performed to understand the origin of pollution (main sectors and geographical areas) and define clear targets for the abatement strategy. Finally the structure of the air quality monitoring is analyzed and discussed to identify options to improve the monitoring strategy not only in the Madrid city but the whole metropolitan area.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.