952 resultados para Adulterated samples
Resumo:
The physicochemical composition of pure royal jelly as well as of some adulterated samples was analyzed by determining moisture, ash, lipids, nitrogen/proteins, carbohydrates, starch and 10- HDA (10-hydroxy-2-decenoic acid). The solubility in alkaline medium was used to detect the main frauds for adulterating royal jelly which comprise addition of yogurt, water, egg white, sweet condensed milk mixed with propolis, unripe banana and corn starch slurry.
Resumo:
Balsamic vinegar (BV) is a typical and valuable Italian product, worldwide appreciated thanks to its characteristic flavors and potential health benefits. Several studies have been conducted to assess physicochemical and microbial compositions of BV, as well as its beneficial properties. Due to highly-disseminated claims of antioxidant, antihypertensive and antiglycemic properties, BV is a known target for frauds and adulterations. For that matter, product authentication, certifying its origin (region or country) and thus the processing conditions, is becoming a growing concern. Striving for fraud reduction as well as quality and safety assurance, reliable analytical strategies to rapidly evaluate BV quality are very interesting, also from an economical point of view. This work employs silica plate laser desorption/ionization mass spectrometry (SP-LDI-MS) for fast chemical profiling of commercial BV samples with protected geographical indication (PGI) and identification of its adulterated samples with low-priced vinegars, namely apple, alcohol and red/white wines.
Resumo:
Ce projet de maitrise implique le développement et l’optimisation de deux méthodes utilisant la chromatographie liquide à haute performance couplée à la spectrométrie de masse en tandem (HPLC-MS/MS). L'objectif du premier projet était de séparer le plus rapidement possible, simultanément, 71 médicaments traitant la dysfonction érectile (ED) et 11 ingrédients naturels parfois retrouvés avec ces médicaments dans les échantillons suspectés d’être adultérés ou contrefaits. L'objectif du deuxième projet était de développer une méthode de dépistage permettant l'analyse rapide simultanée de 24 cannabinoïdes synthétiques et naturels pour une grande variété d'échantillons tels que les mélanges à base de plantes, des bâtons d'encens, de sérums et de cannabis. Dans les deux projets, la séparation a été réalisée en moins de 10 min et cela en utilisant une colonne C18 à noyau solide 100 x 2,1 mm avec des particules de 2,6 µm de diamètre couplée à un système MS avec trappe ionique orbitale fonctionnant en électronébulisation positive. En raison du nombre élevé de composés dans les deux méthodes et de l’émergence de nouveaux analogues sur le marché qui pourraient être présents dans les échantillons futurs, une méthode de dépistage LC-MS/MS ciblée/non-ciblée a été développée. Pour les deux projets, les limites de détection étaient sous les ng/mL et la variation de la précision et de l’exactitude étaient inférieures de 10,5%. Le taux de recouvrement à partir des échantillons réels variait entre 92 à 111%. L’innovation des méthodes LC-MS/MS développées au cours des projets est que le spectre de masse obtenu en mode balayage lors de l'acquisition, fournit une masse exacte pour tous les composés détectés et permet l'identification des composés initialement non-ciblés, comme des nouveaux analogues. Cette innovation amène une dimension supplémentaire aux méthodes traditionnellement utilisées, en permettant une analyse à haute résolution sur la masse de composés non-ciblés.
Resumo:
To detect the presence of male DNA in vaginal samples collected from survivors of sexual violence and stored on filter paper. A pilot study was conducted to evaluate 10 vaginal samples spotted on sterile filter paper: 6 collected at random in April 2009 and 4 in October 2010. Time between sexual assault and sample collection was 4-48hours. After drying at room temperature, the samples were placed in a sterile envelope and stored for 2-3years until processing. DNA extraction was confirmed by polymerase chain reaction for human β-globin, and the presence of prostate-specific antigen (PSA) was quantified. The presence of the Y chromosome was detected using primers for sequences in the TSPY (Y7/Y8 and DYS14) and SRY genes. β-Globin was detected in all 10 samples, while 2 samples were positive for PSA. Half of the samples amplified the Y7/Y8 and DYS14 sequences of the TSPY gene and 30% amplified the SRY gene sequence of the Y chromosome. Four male samples and 1 female sample served as controls. Filter-paper spots stored for periods of up to 3years proved adequate for preserving genetic material from vaginal samples collected following sexual violence.
Resumo:
Infections of the central nervous systems (CNS) present a diagnostic problem for which an accurate laboratory diagnosis is essential. Invasive practices, such as cerebral biopsy, have been replaced by obtaining a polymerase chain reaction (PCR) diagnosis using cerebral spinal fluid (CSF) as a reference method. Tests on DNA extracted from plasma are noninvasive, thus avoiding all of the collateral effects and patient risks associated with CSF collection. This study aimed to determine whether plasma can replace CSF in nested PCR analysis for the detection of CNS human herpesvirus (HHV) diseases by analysing the proportion of patients whose CSF nested PCR results were positive for CNS HHV who also had the same organism identified by plasma nested PCR. In this study, CSF DNA was used as the gold standard, and nested PCR was performed on both types of samples. Fifty-two patients with symptoms of nervous system infection were submitted to CSF and blood collection. For the eight HHV, one positive DNA result-in plasma and/or CSF nested PCR-was considered an active HHV infection, whereas the occurrence of two or more HHVs in the same sample was considered a coinfection. HHV infections were positively detected in 27/52 (51.9%) of the CSF and in 32/52 (61.5%) of the plasma, difference not significant, thus nested PCR can be performed on plasma instead of CSF. In conclusion, this findings suggest that plasma as a useful material for the diagnosis of cases where there is any difficulty to perform a CSF puncture.
Resumo:
The taxonomic position of a bacterium isolated from water samples from the Rio Negro, in Amazon, Brazil, was determined by using a polyphasic approach. The organism formed a distinct phyletic line in the Chromobacterium 16S rRNA gene tree and had chemotaxonomic and morphological properties consistent with its classification in this genus. It was found to be closely related to Chromobacterium vaccinii DSM 25150(T) (98.6 % 16S rRNA gene similarity) and shared 98.5 % 16S rRNA gene similarity with Chromobacterium piscinae LGM 3947(T). DNA-DNA relatedness studies showed that isolate CBMAI 310(T) belongs to distinct genomic species. The isolate was readily distinguished from the type strain of these species using a combination of phenotypic and chemotaxonomic properties. Thus, based on genotypic and phenotypic data, it is proposed that isolate CBMAI 310(T) (=DSM 26508(T)) be classified in the genus Chromobacterium as the type strain of a novel species, namely, Chromobacterium amazonense sp. nov.
Resumo:
Ammonium nitrate fuel oil (ANFO) is an explosive used in many civil applications. In Brazil, ANFO has unfortunately also been used in criminal attacks, mainly in automated teller machine (ATM) explosions. In this paper, we describe a detailed characterization of the ANFO composition and its two main constituents (diesel and a nitrate explosive) using high resolution and accuracy mass spectrometry performed on an FT-ICR-mass spectrometer with electrospray ionization (ESI(±)-FTMS) in both the positive and negative ion modes. Via ESI(-)-MS, an ion marker for ANFO was characterized. Using a direct and simple ambient desorption/ionization technique, i.e., easy ambient sonic-spray ionization mass spectrometry (EASI-MS), in a simpler, lower accuracy but robust single quadrupole mass spectrometer, the ANFO ion marker was directly detected from the surface of banknotes collected from ATM explosion theft.
Resumo:
Conventional reflectance spectroscopy (NIRS) and hyperspectral imaging (HI) in the near-infrared region (1000-2500 nm) are evaluated and compared, using, as the case study, the determination of relevant properties related to the quality of natural rubber. Mooney viscosity (MV) and plasticity indices (PI) (PI0 - original plasticity, PI30 - plasticity after accelerated aging, and PRI - the plasticity retention index after accelerated aging) of rubber were determined using multivariate regression models. Two hundred and eighty six samples of rubber were measured using conventional and hyperspectral near-infrared imaging reflectance instruments in the range of 1000-2500 nm. The sample set was split into regression (n = 191) and external validation (n = 95) sub-sets. Three instruments were employed for data acquisition: a line scanning hyperspectral camera and two conventional FT-NIR spectrometers. Sample heterogeneity was evaluated using hyperspectral images obtained with a resolution of 150 × 150 μm and principal component analysis. The probed sample area (5 cm(2); 24,000 pixels) to achieve representativeness was found to be equivalent to the average of 6 spectra for a 1 cm diameter probing circular window of one FT-NIR instrument. The other spectrophotometer can probe the whole sample in only one measurement. The results show that the rubber properties can be determined with very similar accuracy and precision by Partial Least Square (PLS) regression models regardless of whether HI-NIR or conventional FT-NIR produce the spectral datasets. The best Root Mean Square Errors of Prediction (RMSEPs) of external validation for MV, PI0, PI30, and PRI were 4.3, 1.8, 3.4, and 5.3%, respectively. Though the quantitative results provided by the three instruments can be considered equivalent, the hyperspectral imaging instrument presents a number of advantages, being about 6 times faster than conventional bulk spectrometers, producing robust spectral data by ensuring sample representativeness, and minimizing the effect of the presence of contaminants.
Resumo:
Several characteristics are important in a traceability system of animal products, such as age at slaughter, breed composition, besides information of the productive chain. In general, the certification agent records information about the animals and the system which it came from, although cannot guarantee that the slaughtering, meat processing and distribution are error proof. Besides, there is a differential price, at least at the international market, based on sex and breed composition of the animals. Genetic markers allow identification of characteristics controlled in the beef cattle traceability program, as sex and breed composition, in order to correctly identify and appraise the final product for the consumer. The hypothesis of this study was that the majority beef samples retailed in the local market originate from female with a great participation of zebu breeds. Therefore, the objective of this work was to characterize retail beef samples with DNA markers that identify cattle sex and breed composition. Within 10 beef shops localized in Pirassununga, SP, Brazil, 61 samples were collected, all were genotyped as harboring Bos taurus mitochondrial DNA and 18 were positive for the Y chromosome amplification (male). For the marker sat1711b-Msp I the frequency of the allele A was 0.278 and for the marker Lhr-Hha I the frequency of the allele T was 0.417. The results of sat1711b-Msp I and Lhr-Hha I allelic frequencies are suggestive that the proportion of indicus genome compared with the taurine genome in the market meat is smaller than the observed in the Nellore breed. The procedure described in this study identified sex and subspecies characteristics of beef meat samples, with potential application in meat products certification in special as an auxiliary tool in beef cattle traceability programs.
Resumo:
Technical evaluation of analytical data is of extreme relevance considering it can be used for comparisons with environmental quality standards and decision-making as related to the management of disposal of dredged sediments and the evaluation of salt and brackish water quality in accordance with CONAMA 357/05 Resolution. It is, therefore, essential that the project manager discusses the environmental agency's technical requirements with the laboratory contracted for the follow-up of the analysis underway and even with a view to possible re-analysis when anomalous data are identified. The main technical requirements are: (1) method quantitation limits (QLs) should fall below environmental standards; (2) analyses should be carried out in laboratories whose analytical scope is accredited by the National Institute of Metrology (INMETRO) or qualified or accepted by a licensing agency; (3) chain of custody should be provided in order to ensure sample traceability; (4) control charts should be provided to prove method performance; (5) certified reference material analysis or, if that is not available, matrix spike analysis, should be undertaken and (6) chromatograms should be included in the analytical report. Within this context and with a view to helping environmental managers in analytical report evaluation, this work has as objectives the discussion of the limitations of the application of SW 846 US EPA methods to marine samples, the consequences of having data based on method detection limits (MDL) and not sample quantitation limits (SQL), and present possible modifications of the principal method applied by laboratories in order to comply with environmental quality standards.
Resumo:
Few articles deal with lead and strontium isotopic analysis of water samples. The aim of this study was to define the chemical procedures for Pb and Sr isotopic analyses of groundwater samples from an urban sedimentary aquifer. Thirty lead and fourteen strontium isotopic analyses were performed to test different analytical procedures. Pb and Sr isotopic ratios as well as Sr concentration did not vary using different chemical procedures. However, the Pb concentrations were very dependent on the different procedures. Therefore, the choice of the best analytical procedure was based on the Pb results, which indicated a higher reproducibility from samples that had been filtered and acidified before the evaporation, had their residues totally dissolved, and were purified by ion chromatography using the Biorad® column. Our results showed no changes in Pb ratios with the storage time.
Resumo:
A potentiometric titration method for the determination of minoxidil based on its redox reaction with K2Cr2O7 is described. The best results were observed using 1.00 x 10-3 mol L-1 K2Cr2O7 and 1.00 x 10-2 mol L-1 minoxidil solutions, and the minoxidil as titrant in 2.00 mol L-1 H2SO4 medium. The method was applied to commercial samples and compared with the results from a chromatographic procedure. Recoveries from 97.4 to 98.7 % were observed depending on the sample. Comparison with the chromatographic procedure reveled agreement within 90% confidence level.
Resumo:
An amperometric lactate biosensor with lactate oxidase immobilized into a Prussian Blue (PB) modified electrode was fabricated. The advantage of using cetyltrimethylammonium bromide (CTAB) in the electrodeposition step of PB films onto glassy carbon surfaces was confirmed taking into account both the stability and sensitivity of the measurements. The biosensor was used in the development of a FIA amperometric method for the determination of lactate. Under optimal operating conditions (pH = 6.9, E = -0.1 V), the linear response of the method was extended up to 0.28 µmol L-1 lactate with a limit of detection of 0.84 mmol L-1. The repeatability of the method for injections of a 0.28 mmol L-1 lactate solution was 2.2 % (n = 18). The usefulness of the method was demonstrated by determining lactate in beer samples and the results were in good agreement with those obtained by using a reference spectrophotometric enzyme method.
Resumo:
Molecular characterization of Cryptosporidium spp.oocysts in clinical samples is useful for public health since it allows the study of sources of contamination as well as the transmission in different geographical regions. Although widely used in developed countries, in Brazil it is restricted to academic studies, mostly using commercial kits for the extraction of genomic DNA, or in collaboration with external reference centers, rendering the method expensive and limited. The study proposes the application of the modifications recently introduced in the method improving feasibility with lower cost. This method was efficient for clinical samples preserved at -20 °C for up to six years and the low number of oocysts may be overcomed by repetitions of extraction.
Resumo:
Total phenolic contents, antioxidant activity and chemical composition of propolis samples from three localities of Minas Gerais state (southeast Brazil) were determined. Total phenolic contents were determined by the Folin-Ciocalteau method, antioxidant activity was evaluated by DPPH, using BHT as reference, and chemical composition was analyzed by GC/MS. Propolis from Itapecerica and Paula Candido municipalities were found to have high phenolic contents and pronounced antioxidant activity. From these extracts, 40 substances were identified, among them were simple phenylpropanoids, prenylated phenylpropanoids, sesqui- and diterpenoids. Quantitatively, the main constituent of both samples was allyl-3-prenylcinnamic acid. A sample from Virginopolis municipality had no detectable phenolic substances and contained mainly triterpenoids, the main constituents being alpha-and beta-amyrins. Methanolic extracts from Itapecerica and Paula Candido exhibited pronounced scavenging activity towards DPPH, indistinguishable from BHT activity. However, extracts from Virginopolis sample exhibited no antioxidant activity. Total phenolic substances, GC/MS analyses and antioxidant activity of samples from Itapecerica collected monthly over a period of 1 year revealed considerable variation. No correlation was observed between antioxidant activity and either total phenolic contents or contents of artepillin C and other phenolic substances, as assayed by CG/MS analysis.