943 resultados para Additional somatosensory information
Resumo:
The somatosensory system plays an important role in balance control and age-related changes to this system have been implicated in falls. Parkinson’s disease (PD) is a chronic and progressive disease of the brain, characterized by postural instability and gait disturbance. Previous research has shown that deficiencies in somatosensory feedback may contribute to the poorer postural control demonstrated by PD individuals. However, few studies have comprehensively explored differences in somatosensory function and postural control between PD participants and healthy older individuals. The soles of the feet contain many cutaneous mechanoreceptors that provide important somatosensory information sources for postural control. Different types of insole devices have been developed to enhance this somatosensory information and improve postural stability, but these devices are often too complex and expensive to integrate into daily life. Textured insoles provide a more passive intervention that may be an inexpensive and accessible means to enhance the somatosensory input from the plantar surface of the feet. However, to date, there has been little work conducted to test the efficacy of enhanced somatosensory input induced by textured insoles in both healthy and PD populations during standing and walking. Therefore, the aims of this thesis were to determine: 1) whether textured insole surfaces can improve postural stability by enhancing somatosensory information in younger and older adults, 2) the differences between healthy older participants and PD participants for measures of physiological function and postural stability during standing and walking, 3) how changes in somatosensory information affect postural stability in both groups during standing and walking; and 4), whether textured insoles can improve postural stability in both groups during standing and walking. To address these aims, Study 1 recruited seven older individuals and ten healthy young controls to investigate the effects of two textured insole surfaces on postural stability while performing standing balance tests on a force plate. Participants were tested under three insole surface conditions: 1) barefoot; 2) standing on a hard textured insole surface; and 3), standing on a soft textured insole surface. Measurements derived from the centre of pressure displacement included the range of anterior-posterior and medial-lateral displacement, path length and the 90% confidence elliptical area (C90 area). Results of study 1 revealed a significant Group*Surface*Insole interaction for the four measures. Both textured insole surfaces reduced postural sway for the older group, especially in the eyes closed condition on the foam surface. However, participants reported that the soft textured insole surface was more comfortable and, hence, the soft textured insoles were adopted for Studies 2 and 3. For Study 2, 20 healthy older adults (controls) and 20 participants with Parkinson’s disease were recruited. Participants were evaluated using a series of physiological assessments that included touch sensitivity, vibratory perception, and pain and temperature threshold detection. Furthermore, nerve function and somatosensory evoked potentials tests were utilized to provide detailed information regarding peripheral nerve function for these participants. Standing balance and walking were assessed on different surfaces using a force plate and the 3D Vicon motion analysis system, respectively. Data derived from the force plate included the range of anterior-posterior and medial-lateral sway, while measures of stride length, stride period, cadence, double support time, stance phase, velocity and stride timing variability were reported for the walking assessment. The results of this study demonstrated that the PD group had decrements in somatosensory function compared to the healthy older control group. For electrodiagnosis, PD participants had poorer nerve function than controls, as evidenced by slower nerve conduction velocities and longer latencies in sural nerve and prolonged latency in the P37 somatosensory evoked potential. Furthermore, the PD group displayed more postural sway in both the anterior-posterior and medial-lateral directions relative to controls and these differences were increased when standing on a foam surface. With respect to the gait assessment, the PD group took shorter strides and had a reduced stride period compared with the control group. Furthermore, the PD group spent more time in the stance phase and had increased cadence and stride timing variability than the controls. Compared with walking on the firm surface, the two groups demonstrated different gait adaptations while walking on the uneven surface. Controls increased their stride length and stride period and decreased their cadence, which resulted in a consistent walking velocity on both surfaces. Conversely, while the PD patients also increased their stride period and decreased their cadence and stance period on the uneven surface, they did not increase their stride length and, hence walked slower on the uneven surface. In the PD group, there was a strong positive association between decreased somatosensory function and decreased clinical balance, as assessed by the Tinetti test. Poorer somatosensory function was also strongly positively correlated with the temporospatial gait parameters, especially shorter stride length. Study 3 evaluated the effects of manipulating the somatosensory information from the plantar surface of the feet using textured insoles in the same populations assessed in Study 2. For this study, participants performed the standing and walking balance tests under three footwear conditions: 1) barefoot; 2) with smooth insoles; and 3), with textured insoles. Standing balance and walking were evaluated using a force plate and a Vicon motion analysis system and the data were analysed in the same way outlined for Study 2. The findings showed that the smooth and textured insoles caused different effects on postural control during both the standing and walking trials. Both insoles decreased medial-lateral sway to the same level on the firm surface. The greatest benefits were observed in the PD group while wearing the textured insole. When standing under a more challenging condition on the foam surface with eyes closed, only the textured insole decreased medial-lateral sway in the PD group. With respect to the gait trials, both insoles increased walking velocity, stride length and stride time and decreased cadence, but these changes were more pronounced for the textured insoles. The effects of the textured insoles were evident under challenging conditions in the PD group and increased walking velocity and stride length, while decreasing cadence. Textured insoles were also effective in reducing the time spent in the double support and stance phases of the gait cycle and did not increase stride timing variability, as was the case for the smooth insoles for the PD group. The results of this study suggest that textured insoles, such as those evaluated in this research, may provide a low-cost means of improving postural stability in high-risk groups, such as people with PD, which may act as an important intervention to prevent falls.
Resumo:
Recent studies examining adaptation to unexpected changes in the mechanical environment highlight the use of position error in the adaptation process. However, force information is also available. In this chapter, we examine adaptation processes in three separate studies where the mechanical environment was changed intermittently. We compare the expected consequences of using position error and force information in the changes to motor commands following a change in the mechanical environment. In general, our results support the use of position error over force information and are consistent with current computational models of motor learning. However, in situations where the change in the mechanical environment eliminates position error the central nervous system does not necessarily respond as would be predicted by these models. We suggest that it is necessary to take into account the statistics of prior experience to account for our observations. Another deficiency in these models is the absence of a mechanism for modulating limb mechanical impedance during adaptation. We propose a relatively simple computational model based on reflex responses to perturbations which is capable of accounting for iterative changes in temporal patterns of muscle co-activation.
Resumo:
PURPOSE: To evaluate the permanent prostate brachytherapy (PPB) learning curve using postimplant multisector dosimetric analysis and to assess the correlation between sector -specific dosimetry and patient-reported outcome measures (PROMs).
METHODS AND METHODS: First 200 patients treated with (125)I PPB monotherapy (145 Gy) at a single institution were assessed. Postimplant dosimetry (PID) using CT was evaluated for whole prostate (global) and 12 sectors, assessing minimum dose to 90% of prostate (D90) and dose to 0.1 cm(3) of rectum (D0.1cc). Global and sector PID results were evaluated to investigate changes in D90 with case number. Urinary and bowel PROMs were assessed using the International Prostate Symptom Score and the Expanded Prostate Cancer Index Composite questionnaire. The correlation between global and individual sector PID and urinary/bowel PROMs was also evaluated.
RESULTS: Linear regression confirmed a significant improvement in global D90 with case number (r(2) = 0.20; p = 0.001) at a rate of 0.11 Gy/case. Postimplant D90 of base sectors increased at a rate of 0.11-0.15 Gy/case (p = 0.0001) and matched global improvement. The regression lines of midgland and apex sectors were significantly different from global D90 (p = 0.01). Posterior midgland sectors showed a significant reduction in D90 with case number at a rate of 0.13-0.19 Gy/case (p = 0.01). Dose to posterior midgland sectors correlated with rectal D0.1cc dose but not bowel PROMs. Dose to posterior midgland sectors correlated with urinary International Prostate Symptom Score change, which was not apparent when global D90 alone was considered.
CONCLUSIONS: Sector analysis provided increased spatial information regarding the PPB learning curve. Furthermore, sector analysis correlated with urinary PROMs and rectal dose.
Resumo:
This study investigated developmental changes in the use of a contact surface during the acquisition of upright posture. Standing infants were longitudinally examined at four developmental epochs: pulling to stand (PS); standing alone (SA); walking onset (WO); and 1.5 months post-walking (PW). The results revealed that as standing experience increased the force applied to the contact surface by the hand and the body sway decreased. Applied force and body sway were consistently related in the anterior-posterior direction (r approximate to 0.65). Temporally, body sway led applied force (approximate to 45 ms) at the PS, SA, and WO developmental periods. However, at PW, the temporal relationship reversed and applied force led body sway (approximate to 140 ms). These results indicate that initially infants use surface contact for mechanical purposes but later for orientation information that affords prospective control of posture.
Resumo:
The purpose of this investigation was to determine whether the coupling between dynamic somatosensory information and body sway is similar in children and adults. Thirty children (4-, 6-, and 8-year-olds) and 10 adults stood upright, with feet parallel, and lightly contacting the fingertip to a rigid metal plate that moved rhythmically at 0.2, 0.5, and 0.8 Hz. Light touch to the moving contact surface induced postural sway in all participants. The somatosensory stimulus produced a broadband frequency response in children, while the adult response was primarily at the driving frequency. Gain, as a function of frequency, was qualitatively the same in children and adults. Phase decreased less in 4-year-olds than other age groups, suggesting a weaker coupling to position information in the sensory stimulus. Postural sway variability was larger in children than adults. These findings suggest that, even as young as age 6, children show well-developed coupling to the sensory stimulus. However, unlike adults, this coupling is not well focused at the frequency specified by the somatosensory signal. Children may be unable to uncouple from sensory information that is less relevant to the task, resulting in a broadband response in their frequency spectrum. Moreover, higher sway variability may not result from the sensory feedback process, but rather from the children's underdeveloped ability to estimate an internal model of body orientation.
Resumo:
Pós-graduação em Genética e Melhoramento Animal - FCAV
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
The purpose of this study was to examine the effects of visual and somatosensory information on body sway in individuals with Down syndrome (DS). Nine adults with DS (19-29 years old) and nine control subjects (CS) (19-29 years old) stood in the upright stance in four experimental conditions: no vision and no touch; vision and no touch; no vision and touch; and vision and touch. In the vision condition, participants looked at a target placed in front of them; in the no vision condition, participants wore a black cotton mask. In the touch condition, participants touched a stationary surface with their right index finger; in the no touch condition, participants kept their arms hanging alongside their bodies. A force plate was used to estimate center of pressure excursion for both anterior-posterior and medial-lateral directions. MANOVA revealed that both the individuals with DS and the control subjects used vision and touch to reduce overall body sway, although individuals with DS still oscillated more than did the CS. These results indicate that adults with DS are able to use sensory information to reduce body sway, and they demonstrate that there is no difference in sensory integration between the individuals with DS and the CS.
Resumo:
BACKGROUND: Virtual reality testing of everyday activities is a novel type of computerized assessment that measures cognitive, executive, and motor performance as a screening tool for early dementia. This study used a virtual reality day-out task (VR-DOT) environment to evaluate its predictive value in patients with mild cognitive impairment (MCI). METHODS: One hundred thirty-four patients with MCI were selected and compared with 75 healthy control subjects. Participants received an initial assessment that included VR-DOT, a neuropsychological evaluation, magnetic resonance imaging (MRI) scan, and event-related potentials (ERPs). After 12 months, participants were assessed again with MRI, ERP, VR-DOT, and neuropsychological tests. RESULTS: At the end of the study, we differentiated two subgroups of patients with MCI according to their clinical evolution from baseline to follow-up: 56 MCI progressors and 78 MCI nonprogressors. VR-DOT performance profiles correlated strongly with existing predictive biomarkers, especially the ERP and MRI biomarkers of cortical thickness. CONCLUSIONS: Compared with ERP, MRI, or neuropsychological tests alone, the VR-DOT could provide additional predictive information in a low-cost, computerized, and noninvasive way.
Resumo:
In the present work, effects of stimulus repetition and change in a continuous stimulus stream on the processing of somatosensory information in the human brain were studied. Human scalp-recorded somatosensory event-related potentials (ERPs) and magnetoencephalographic (MEG) responses rapidly diminished with stimulus repetition when mechanical or electric stimuli were applied to fingers. On the contrary, when the ERPs and multi-unit a ctivity (MUA) were directly recorded from the primary (SI) and secondary (SII) somatosensory cortices in a monkey, there was no marked decrement in the somatosensory responses as a function of stimulus repetition. These results suggest that this rate effect is not due to the response diminution in the SI and SII cortices. Obviously the responses to the first stimulus after a long "silent" period are nhanced due to unspecific initial orientation, originating in more broadly distributed and/or deeper neural structures, perhaps in the prefrontal cortices. With fast repetition rates not only the late unspecific but also some early specific somatosensory ERPs were diminished in amplitude. The fast decrease of the ERPs as a function of stimulus repetition is mainly due to the disappearance of the orientation effect and with faster repetition rates additively due to stimulus specific refractoriness. A sudden infrequent change in the continuous stimulus stream also enhanced somatosensory MEG responses to electric stimuli applied to different fingers. These responses were quite similar to those elicited by the deviant stimuli alone when the frequent standard stimuli were omitted. This enhancement was obviously due to the release from refractoriness because the neural structures generating the responses to the infrequent deviants had more time to recover from the refractoriness than the respective structures for the standards. Infrequent deviant mechanical stimuli among frequent standard stimuli also enhanced somatosensory ERPs and, in addition, they elicited a new negative wave which did not occur in the deviants-alone condition. This extra negativity could be recorded to deviations in the stimulation site and in the frequency of the vibratory stimuli. This response is probably a somatosensory analogue of the auditory mismatch negativity (MMN) which has been suggested to reflect a neural mismatch process between the sensory input and the sensory memory trace.
Resumo:
In older adults, cognitive resources play a key role in maintaining postural stability. In the present study, we evaluated whether increasing postural instability using sway referencing induces changes in resource allocation in dual-task performance leading older adults to prioritize the more age-salient posture task over a cognitive task. Young and older adults participated in the study which comprised two sessions. In the first session, three posture tasks (stable, sway reference visual, sway reference somatosensory) and a working memory task (n-back) were examined. In the second session, single- and dual-task performance of posture and memory were assessed. Postural stability improved with session. Participants were more unstable in the sway reference conditions, and pronounced age differences were observed in the somatosensory sway reference condition. In dual-task performance on the stable surface, older adults showed an almost 40% increase in instability compared to single-task. However, in the sway reference somatosensory condition, stability was the same in single- and dual-task performance, whereas pronounced (15%) costs emerged for cognition. These results show that during dual-tasking while standing on a stable surface, older adults have the flexibility to allow an increase in instability to accommodate cognitive task performance. However, when instability increases by means of compromising somatosensory information, levels of postural control are kept similar in single- and dual-task, by utilizing resources otherwise allocated to the cognitive task. This evidence emphasizes the flexible nature of resource allocation, developed over the life-span to compensate for age-related decline in sensorimotor and cognitive processing.