Resumo:
Aim: To evaluate the influence of construction bite in the dentoskeletal changes induced by Klammt Appliance. Methods: The sample consisted of 17 children, with Class II malocclusion and initial mean age of 8.5 years. The construction bite was obtained using an Exactobite on edge-toedge anteroposterior relationship with 3 mm interincisal clearance. The height of the acrylic was determined by initial overbite associated to interincisal clearance and measured with digital caliper. The amount of advancement was obtained and measured by initial overjet in the lateral radiography. Pearson's correlation, linear regression and ANOVA were used to determine the relationship between dentoskeletal and construction bite variables. Results: The increase in the height of the acrylic promotes a greater inhibition of the forward displacement of the nasal spine and reduction in the facial growth index. The increase in the mandibular advancement induces more downward displacement of nasal spine and pogonion; a counter-clockwise rotation of palatine plane; an increase in mandibular length, maxillary alveolar height and interincisal angle; a decrease in mandibular alveolar height, the intermaxillary discrepancy and overjet; and palatal tipping of upper incisors. Conclusions: The different dimensions of the construction bite influence the dentoskeletal changes induced by the appliance in Class II treatment.
Resumo:
Objective: The purpose of this study was to evaluate the facial profile changes induced by Balters' bionator appliance in Class II division 1 patients, at mixed dentition stage. Methods: The sample consisted of 28 prepubertal individuals at stages 1 and 2 of skeletal maturation (CVM), which were divided in two groups. The experimental group consisted of 14 individuals (7 boys and 7 girls, initial mean age of 8y12m) which were treated with Balters' bionator appliance for 14.7 months. The effects of treatment were compared to a control group of 14 subjects (7 boys and 7 girls, initial mean age of 8y5m) with Class II malocclusion, division 1, not orthodontically treated, which were followed up for 15.4 months. The statistical analysis was performed using Student's t test, at a significance level of 5%. Results: The results showed that the Balters' bionator appliance promoted a significant increase on the mentolabial angle, in addition to demonstrating a tendency to reduce the facial skeletal convexity, to restrict the maxillary growth and to increase the nasolabial angle and the lower anterior facial height. Conclusion: It can be concluded that the Balters' bionator appliance improved the facial profile of children treated at mixed dentition stage. © 2013 Dental Press Journal of Orthodontics.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
INTRODUCTION: This study evaluated posteroanterior cephalograms before and after treatment and long term follow-up of Class II division 1 patients treated with bionator. OBJECTIVE: The objective was to demonstrate the transverse growth of maxilla and mandible during and after bionator therapy. METHODS: Measurement of transverse dimensions between posterior maxillary and mandibular implants, as well as the distances between the buccal, gonial and antegonial points were recorded. Measurements were analyzed at three periods: T1 = before bionator therapy, T2 = after bionator therapy and T3 = 5.74 years after T2. RESULTS: There was statistically significant transverse increase due to growth and/or treatment for all variables, except for the distance between the anterior maxillary implants. CONCLUSIONS: During the study period only the anterior maxillary area did not show transverse growth.
Resumo:
Aim: To demonstrate the magnitude and direction of skeletal changes in the maxilla and mandible during and after the use of bionator, as well as their rotations. Methods: Partial superimposition on the maxilla and mandible on the metallic implants and total superimposition on the cranial base were performed at three periods, T1 before bionator therapy, T2 after bionator therapy, and T3 5.68 years after T2. Results: There was total clockwise maxillary rotation and counterclockwise mandibular rotation, in the North American technique, throughout the study period, as well as extensive remodeling on the condylar region, especially in vertical direction and on the gonial region in horizontal direction. Conclusions: The total maxillary rotation seemed to be significantly affected by therapy than the mandible. There was a clear change in the direction of condylar remodeling compared to the period of bionator therapy and posterior bionator therapy. Considering the entire study period, it was observed that intra-matrix rotation of the maxilla and mandible masked their total rotation, causing minimum changes in the matrix rotation.
Resumo:
The study aimed to assess the degree of dental crowding correction on the lower anterior region of patients treated with T4k functional appliance using Little’s irregularity index. Twenty caucasian patients of both gender (10 female and 10 male) were selected. They featured malocclusion Class I and II in mixed dentition, with chronological age between 5.7 and 11 years. The treatment lasted from 1 year and 11 months up to 3 years and 11 months. Lower anterior crowding was measured using Little’s irregularity index. Measurements were obtained on study models achieved before and after functional orthopedic therapy, using a digital caliper in millimeters and placed parallel to the occlusal plane. Overjet and overbite measurements were also performed using a caliper. Results demonstrated that the therapy provided significant decrease in overjet (average = 1.55 mm) and also in the irregularity index (average = 1.23 mm). There was a nonsignificant raise in overbite. There was no relation between the studied variables and the treatment period or even with the patient’s age in the beginning of the therapy. The treatment with T4k resulted on reduction and improvement of dental crowding.
Resumo:
The aim of this study was to evaluate the vertical and horizontal dentoskeletal changes induced by the Klammt Open Elastic Activator in the treatment of the Class II Division 1 malocclusion. The sample of 34 children was divided into two groups of 17 subjects each (ten girls, seven boys), matched by age and gender and with an initial mean age of 8.5 years. The data was analyzed using a Student's t-test for intragroup and intergroup comparison. The results showed that the appliance promoted dentoalveolar restriction of the maxilar growth within normal anteroposterior and vertical growth of the maxillary apical base; increment in the vertical displacement the mandibular symphysis associated with normal horizontal growth of the mandible; palatal tipping of the upper incisors; restriction of the anterior migration of the upper molars; greater eruption pattern and normal anterior displacement of the lower incisors and molars. It was concluded that Klammt appliance induce changes that are predominantly horizontal dentoalveolar in upper arch and vertical dentoalveolar in lower arch and vertical skeletal changes in the mandible.
Resumo:
O objetivo deste estudo retrospectivo foi comparar a eficiência oclusal do tratamento ortopédico com os aparelhos funcionais Regulador de Função Fränkel-2 e Bionator de Balters em um estágio de desenvolvimento dental diferente e comparar com um grupo controle. A amostra constituiu-se de 45 registros de documentações, pertencentes ao arquivo do programa de pós-graduação em Odontologia, área de concentração Ortodontia, da Universidade Metodista de São Paulo, com má oclusão inicial de Classe II bilateral, divisão 1, sendo 15 pacientes provenientes do grupo tratados com Bionator (grupo 1) com média de idade incial de 8,56 anos e com 80% dos casos em um estágio de desenvolvimento dental-2 (DS 2), 15 pacientes tratados com RF-2 (grupo 2) com média de idade inicial de 10,71 anos e com 80% dos casos em um estágio de desenvolvimento dental-3 (DS 3), e 15 pacientes controle (grupo 3) com media de idade incial de 10,03 anos e com estágio de desenvolvimento dental compatível com os grupos 1 e 2. Os grupos foram divididos em duas fases, de acordo com o período de avaliação: T1:início de tratamento e T2: final de tratamento, totalizando 90 pares de modelos. As avaliações oclusais foram realizadas em modelos de gesso, utilizando o Índice PAR com auxílio da régua PAR e de um paquímetro digital devidamente calibrado. Para comparação entre os três grupos foi utilizado Análise de Variância a um critério e em seguida o Teste de Tukey. A severidade da má oclusão (PAR Inicial) foi semelhante em ambos os grupos, porém, o PAR final apresentou uma diferença estatisticamente significante onde o percentual de redução do índice PAR para o grupo 1 foi de 20,72%, para o grupo 2 foi de 60,06% e no grupo 3 não houve alteração significante do valor do Índice PAR. O presente estudo conclui que o tratamento da má oclusão de Classe II, 1a divisão é mais eficiente quando iniciado no estágio de desenvolvimento dental 3 (DS 3) do que no estágio de desenvolvimento dental 2 (DS2). Além disso, ressalta-se a importância do uso mais prolongado do aparelho ortopédico, já que os pacientes do grupo 2 apresentaram melhores resultados oclusais.(AU)
Resumo:
Introduction: The aim of this study was to compare the dentoskeletal changes of patients with Class II Division 1 malocclusion treated with either the Jasper jumper appliance or the activator-headgear combination, both associated with fixed appliances. Methods: The sample comprised 72 subjects with Class II Division 1 malocclusion divided into 3 groups: group 1 included 25 subjects treated with fixed appliances and the force modules of the Jasper jumper at an initial mean age of 12.72 years, group 2 included 25 subjects treated with the activator-headgear combination followed by fixed appliances at an initial mean age of 11.07 years, and group 3 included 22 untreated subjects at an initial mean age of 12.67 years. Initial cephalometric characteristics and dentoskeletal changes were compared with analysis of variance. Results: Both experimental groups had similar dentoskeletal changes: restrictive effect on the maxilla, clockwise mandibular rotation and a slight increase in anterior face height, retrusion of the maxillary incisors, distalization of the maxillary molars, protrusion of the mandibular incisors, extrusion of the mandibular molars, and significant improvements of the maxillomandibular relationship, overjet, overbite, and the molar relationship. Conclusions: The effects of the Jasper jumper and the activator-headgear combination followed by fixed orthodontic appliances were similar in Class II malocclusion treatment.
Resumo:
The purpose of this study is to investigate the orthodontic and orthopaedic real effects of the Klammt's Elastic Open Activator (EOA) in 25 Class II Division 1 patients in growing period. We wanted to determine statistically the cephalometrics changes produced in the patients, comparing the lateral cranium teleradiographies we took for the diagnosis with the ones we took at the end of treatment. At the end of this study we confirm that by using the EOA we obtained the desired effects, especially reducing the molar relation 2.53 mm and the overjet 2.56 mm. The EOA corrected the inclination and protrusion of incisors, although we cannot avoid the use of fixed appliances to round off. The reduction of 2.48 mm of facial convexity stands out as the most important skeletal effect; the facial depth angle increases 0.8 degree, and the maxillary depth decreases 1.16 degrees. The length of the mandibular corpus also increases 6.7 mm, although this change is mainly due to the growth of the patient. The changes in the aesthetic profile do not stand out
Resumo:
Objective: To analyze the long-term skeletal and dentoalveolar effects and to evaluate treatment timing of Class II treatment with functional appliances followed by fixed appliances.Materials and Methods: A group of 40 patients (22 females and 18 males) with Class II malocclusion consecutively treated either with a Bionator or an Activator followed by fixed appliances was compared with a control group of 20 subjects (9 females and 11 males) with untreated Class II malocclusion. Lateral cephalograms were available at the start of treatment (mean age 10 years), end of treatment with functional appliances (mean age 12 years), and long-term observation (mean age 18.6 years). The treated sample also was divided into two groups according to skeletal maturity. The early-treatment group was composed of 20 subjects (12 females and 8 males) treated before puberty, while the late-treatment group included 20 subjects (10 females and 10 males) treated at puberty. Statistical comparisons were performed with analysis of variance followed by Tukey's post hoc tests.Results: Significant long-term mandibular changes (Co-Gn) in the treated group (3.6 mm over the controls) were associated with improvements in the skeletal sagittal intermaxillary relationship, overjet, and molar relationship (similar to 3.0-3.5 mm). Treatment during the pubertal peak was able to produce significantly greater increases in total mandibular length (4.3 mm) and mandibular ramus height (3.1 mm) associated with a significant advancement of the bony chin (3.9 mm) when compared with treatment before puberty.Conclusion: Treatment of Class II malocclusion with functional appliances appears to be more effective at puberty. (Angle Orthod. 2013;83:334-340.)
Resumo:
Congenital diaphragmatic hernia (CDH) is associated with pulmonary hypertension which is often difficult to manage, and a significant cause of morbidity and mortality. In this study, we have used a rabbit model of CDH to evaluate the effects of BAY 60-2770 on the in vitro reactivity of left pulmonary artery. CDH was performed in New Zealand rabbit fetuses (n = 10 per group) and compared to controls. Measurements of body, total and left lung weights (BW, TLW, LLW) were done. Pulmonary artery rings were pre-contracted with phenylephrine (10 μM), after which cumulative concentration-response curves to glyceryl trinitrate (GTN; NO donor), tadalafil (PDE5 inhibitor) and BAY 60-2770 (sGC activator) were obtained as well as the levels of NO (NO3/NO2). LLW, TLW and LBR were decreased in CDH (p < 0.05). In left pulmonary artery, the potency (pEC50) for GTN was markedly lower in CDH (8.25 ± 0.02 versus 9.27 ± 0.03; p < 0.01). In contrast, the potency for BAY 60-2770 was markedly greater in CDH (11.7 ± 0.03 versus 10.5 ± 0.06; p < 0.01). The NO2/NO3 levels were 62 % higher in CDH (p < 0.05). BAY 60-2770 exhibits a greater potency to relax the pulmonary artery in CDH, indicating a potential use for pulmonary hypertension in this disease.
Resumo:
To characterize the relaxation induced by the soluble guanylate cyclase (sGC) activator, BAY 60-2770 in rabbit corpus cavernosum. Penis from male New Zealand rabbits were removed and fours strips of corpus cavernosum (CC) were obtained. Concentration-response curves to BAY 60-2770 were carried out in the absence and presence of inhibitors of nitric oxide synthase, L-NAME (100 μM), sGC, ODQ (10 μM) and phosphodiestarase type 5, tadalafil (0.1 μM). The potency (pEC50) and maximal response (Emax) values were determined. Second, electrical-field stimulation (EFS)-induced contraction or relaxation was realized in the absence and presence of BAY 60-2770 (0.1 or 1 μM) alone or in combination of ODQ (10 μM). In the case of EFS-induced relaxation two protocols were realized: 1) ODQ (10 μM) was first incubated for 20 min and then BAY 60-2770 (1 μM) was added for another 20 min (ODQ + BAY 60-2770). In different CC strips, BAY 60-2770 was incubated for 20 min followed by another 20 min with ODQ (BAY 60-2770 + ODQ). The intracellular levels of cyclic guanosine monophosphate (cGMP) were also determined. BAY 60-2770 potently relaxed rabbit CC with pEC50 and Emax values of 7.58 ± 0.19 and 81 ± 4%, respectively. The inhibitors ODQ (n=7) or tadalafil (n=7) produced 4.2- and 6.3-leftward shifts, respectively in BAY 60-2770-induced relaxation without interfering on the Emax values. The intracellular levels of cGMP were augmented after stimulation with BAY 60-2770 (1 μM) alone, whereas its co-incubation with ODQ produced even higher levels of cGMP. The EFS-induced contraction was reduced in the presence of BAY 60-2770 (1 μM) and this inhibition was even greater when BAY 60-2770 was co-incubated with ODQ. The nitrergic stimulation induced CC relaxation, which was abolished in the presence of ODQ. BAY 60-2770 alone increased the amplitude of relaxation. Co-incubation of ODQ and BAY 60-2770 did not alter the relaxation in comparison with ODQ alone. Interestingly, when BAY 60-2770 was incubated prior to ODQ, EFS-induced relaxation was partly restored in comparison with ODQ alone or ODQ + BAY 60-2770. Considering that the relaxation induced by the sGC activator, BAY 60-2770 was increased after sGC oxidation and unaltered in the absence of nitric oxide, these class of substances are advantageous over sGC stimulators or PDE5 inhibitors for the treatment in those patients with erectile dysfunction and high endothelial damage. This article is protected by copyright. All rights reserved.
Resumo:
Purpose: The apoptosis of retinal neurons plays a critical role in the pathogenesis of diabetic retinopathy (DR), but the molecular mechanisms underlying this phenomenon remain unclear. The purpose of this study was to investigate the cellular localization and the expression of microRNA-29b (miR-29b) and its potential target PKR associated protein X (RAX), an activator of the pro-apoptotic RNA-dependent protein kinase (PKR) signaling pathway, in the retina of normal and diabetic rats. Methods: Retinas were obtained from normal and diabetic rats within 35 days after streptozotocin (STZ) injection. In silico analysis indicated that RAX is a potential target of miR-29b. The cellular localization of miR-29b and RAX was assessed by in situ hybridization and immunofluorescence, respectively. The expression levels of miR-29b and RAX mRNA were evaluated by quantitative reverse transcription PCR (qRT-PCR), and the expression of RAX protein was evaluated by western blot. A luciferase reporter assay and inhibition of endogenous RAX were performed to confirm whether RAX is a direct target of miR-29b as predicted by the in silico analysis. Results: We found that miR-29b and RAX are localized in the retinal ganglion cells (RGCs) and the cells of the inner nuclear layer (INL) of the retinas from normal and diabetic rats. Thus, the expression of miR-29b and RAX, as assessed in the retina by quantitative RT-PCR, reflects their expression in the RGCs and the cells of the INL. We also revealed that RAX protein is upregulated (more than twofold) at 3, 6, 16, and 22 days and downregulated (70%) at 35 days, whereas miR-29b is upregulated (more than threefold) at 28 and 35 days after STZ injection. We did not confirm the computational prediction that RAX is a direct target of miR-29b. Conclusions: Our results suggest that RAX expression may be indirectly regulated by miR-29b, and the upregulation of this miRNA at the early stage of STZ-induced diabetes may have a protective effect against the apoptosis of RGCs and cells of the INL by the pro-apoptotic RNA-dependent protein kinase (PKR) signaling pathway.