916 resultados para Acoustic streaming -- Computer simulation
Resumo:
Time correlation functions of current fluctuations were calculated by molecular dynamics (MD) simulations in order to investigate sound waves of high wavevectors in the glass-forming liquid Ca(NO3)(2)center dot 4H(2)O. Dispersion curves, omega(k), were obtained for longitudinal (LA) and transverse acoustic (TA) modes, and also for longitudinal optic (LO) modes. Spectra of LA modes calculated by MD simulations were modeled by a viscoelastic model within the memory function framework. The viscoelastic model is used to rationalize the change of slope taking place at k similar to 0.3 angstrom(-1) in the omega(k) curve of acoustic modes. For still larger wavevectors, mixing of acoustic and optic modes is observed. Partial time correlation functions of longitudinal mass currents were calculated separately for the ions and the water molecules. The wavevector dependence of excitation energies of the corresponding partial LA modes indicates the coexistence of a relatively stiff subsystem made of cations and anions, and a softer subsystem made of water molecules. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4751548]
Resumo:
The aim of this thesis is the subjective and objective evaluation of angledependent absorption coefficients. As the assumption of a constant absorption coefficient over the angle of incidence is not always held, a new model acknowledging an angle-dependent reflection must be considered, to get a more accurate prediction in the sound field. The study provides information about the behavior of different materials in several rooms, depending on the reflection modeling of incident sound waves. An objective evaluation was run for an implementation of angle-dependent reflection factors in the image source and ray tracing simulation models. Results obtained were analysed after comparison to diffuse-field averaged data. However, changes in acoustic characteristics of a room do not always mean a variation in the listener’s perception. Thus, additional subjective evaluation allowed a comparison between the different results obtained with the computer simulation and the response from the individuals who participated in the listening test. The listening test was designed following a three-alternative forced-choice (3AFC) paradigm. In each interaction asked to the subjects a sequence of either three pink noise bursts or three natural signals was alternated. These results were supposed to show the influence and perception of the two different ways to implement surface reflection –either with diffuse or angle-dependent absorption properties. Results show slightly audible effects when material properties were exaggerated. El objetivo de este trabajo es la evaluación objetiva y subjetiva del coeficiente de absorción en función del ángulo de incidencia de la onda de sonido. La suposición de un coeficiente de absorción constante con respecto al ángulo de incidencia no siempre se sostiene. Por ello, un nuevo modelo considerando la reflexión dependiente del ángulo se debe tener en cuenta para obtener predicciones más certeras en el campo del sonido. El estudio proporciona información sobre el comportamiento de diferentes materiales en distintos recintos, dependientes del modelo de reflexión de las ondas de sonido incidentes. Debido a las dificultades a la hora de realizar las medidas y, por lo tanto, a la falta de datos, los coeficientes de absorción dependientes del ángulo a menudo no se tienen en cuenta a la hora de realizar las simulaciones. Hoy en día, aún no hay una tendencia de aplicar el coeficiente de absorción dependiente del ángulo para mejorar los modelos de reflexión. Por otra parte, para una medición satisfactoria de la absorción dependiente del ángulo, sólo hay unos pocos métodos. Las técnicas de medición actuales llevan mucho tiempo y hay algunos materiales, condiciones y ángulos que no pueden ser reproducidos y, por lo tanto, no es posible su medición. Sin embargo, en el presente estudio, los ángulos de incidencia de las ondas de sonido son conocidos y almacenados en una de base de datos para cada uno de los materiales, de modo que los coeficientes de absorción para el ángulo dado pueden ser devueltos siempre que sean requeridos por el usuario. Para realizar el estudio se llevó a cabo una evaluación objetiva, por medio de la implementación del factor de reflexión dependiente del ángulo en los modelos de fuentes imagen y trazado de rayos. Los resultados fueron analizados después de ser comparados con el promedio de los datos obtenidos en medidas en el campo difuso. La simulación se hizo una vez se configuraron un número de materiales creados por el autor, a partir de los datos existentes en la literatura y los catálogos de fabricantes. Los modelos de Komatsu y Mechel sirvieron como referencia para los materiales porosos, configurando la resistividad al aire o el grosor, y para los paneles perforados, introduciendo el radio de los orificios y la distancia entre centros, respectivamente. Estos materiales se situaban en la pared opuesta a la que se consideraba que debía alojar a la fuente sonora. El resto de superficies se modelaban con el mismo material, variando su coeficiente de absorción y/o de dispersión. Al mismo tiempo, una serie de recintos fueron modelados para poder reproducir distintos escenarios de los que obtener los resultados. Sin embargo, los cambios en las características acústicas de un recinto no significan variaciones en la percepción por parte del oyente. Por ello, una evaluación subjetiva adicional permitió una comparación entre los diferentes resultados obtenidos mediante la simulación informática y la respuesta de los individuos que participaron en la prueba de escucha. Ésta fue diseñada bajo las pautas del modelo de test three-alternative forced-choice (3AFC), con treinta y dos preguntas diferentes. En cada iteración los sujetos fueron preguntados por una secuencia alterna entre tres señales, siendo dos de ellas iguales. Éstas podían ser tanto ráfagas de ruido rosa como señales naturales, en este test se utilizó un fragmento de una obra clásica interpretada por un piano. Antes de contestar al cuestionario, los bloques de preguntas eran ordenados al azar. Para cada ensayo, la mezcla era diferente, así los sujetos no repetían la misma prueba, evitando un sesgo por efectos de aprendizaje. Los bloques se barajaban recordando siempre el orden inicial, para después almacenar los resultados reordenados. La prueba de escucha fue realizada por veintitrés personas, toda ellas con conocimientos dentro del campo de la acústica. Antes de llevar a cabo la prueba de escucha en un entorno adecuado, una hoja con las instrucciones fue facilitada a cada persona. Los resultados muestran la influencia y percepción de las dos maneras distintas de implementar las reflexiones de una superficie –ya sea con respecto a la propiedad de difusión o de absorción dependiente del ángulo de los materiales. Los resultados objetivos, después de ejecutar las simulaciones, muestran los datos medios obtenidos para comprender el comportamiento de distintos materiales de acuerdo con el modelo de reflexión utilizado en el caso de estudio. En las tablas proporcionadas en la memoria se muestran los valores del tiempo de reverberación, la claridad y el tiempo de caída temprana. Los datos de las características del recinto obtenidos en este análisis tienen una fuerte dependencia respecto al coeficiente de absorción de los diferentes materiales que recubren las superficies del cuarto. En los resultados subjetivos, la media de percepción, a la hora de distinguir las distintas señales, por parte de los sujetos, se situó significativamente por debajo del umbral marcado por el punto de inflexión de la función psicométrica. Sin embargo, es posible concluir que la mayoría de los individuos tienden a ser capaces de detectar alguna diferencia entre los estímulos presentados en el 3AFC test. En conclusión, la hipótesis de que los valores del coeficiente de absorción dependiente del ángulo difieren es contrastada. Pero la respuesta subjetiva de los individuos muestra que únicamente hay ligeras variaciones en la percepción si el coeficiente varía en intervalos pequeños entre los valores manejados en la simulación. Además, si los parámetros de los materiales acústicos no son exagerados, los sujetos no perciben ninguna variación. Los primeros resultados obtenidos, proporcionando información respecto a la dependencia del ángulo, llevan a una nueva consideración en el campo de la acústica, y en la realización de nuevos proyectos en el futuro. Para futuras líneas de investigación, las simulaciones se deberían realizar con distintos tipos de recintos, buscando escenarios con geometrías irregulares. También, la implementación de distintos materiales para obtener resultados más certeros. Otra de las fases de los futuros proyectos puede realizarse teniendo en cuenta el coeficiente de dispersión dependiente del ángulo de incidencia de la onda de sonido. En la parte de la evaluación subjetiva, realizar una serie de pruebas de escucha con distintos individuos, incluyendo personas sin una formación relacionada con la ingeniería acústica.
Resumo:
Scoliosis is a spinal deformity, involving a side-to-side curvature of the spine in the coronal plane as well as a rotation of the spinal column in the transverse plane. The coronal curvature is measured using a Cobb angle. If the deformity is severe, treatment for scoliosis may require surgical intervention whereby a rod is attached to the spinal column to correct the abnormal curvature. In order to provide surgeons with an improved ability to predict the likely outcomes following surgery, techniques to create patient-specific finite element models (FEM) of scoliosis patients treated at the Mater Children’s Hospital (MCH) in Brisbane are being developed and validated. This paper presents a comparison of the simulated and clinical data for a scoliosis patient treated at MCH.
Resumo:
Scoliosis is a three-dimensional spinal deformity which requires surgical correction in progressive cases. In order to optimize correction and avoid complications following scoliosis surgery, patient-specific finite element models (FEM) are being developed and validated by our group. In this paper, the modeling methodology is described and two clinically relevant load cases are simulated for a single patient. Firstly, a pre-operative patient flexibility assessment, the fulcrum bending radiograph, is simulated to assess the model's ability to represent spine flexibility. Secondly, intra-operative forces during single rod anterior correction are simulated. Clinically, the patient had an initial Cobb angle of 44 degrees, which reduced to 26 degrees during fulcrum bending. Surgically, the coronal deformity corrected to 14 degrees. The simulated initial Cobb angle was 40 degrees, which reduced to 23 degrees following the fulcrum bending load case. The simulated surgical procedure corrected the coronal deformity to 14 degrees. The computed results for the patient-specific FEM are within the accepted clinical Cobb measuring error of 5 degrees, suggested that this modeling methodology is capable of capturing the biomechanical behaviour of a scoliotic human spine during anterior corrective surgery.
Resumo:
Endoscopic approaches for anterior correction of idiopathic scoliosis are a relatively new surgical technique. This paper describes the development of patient-specific finite element modelling techniques to investigate the biomechanics of single rod anterior scoliosis correction. Spinal geometry is obtained from pre-operative CT scans and material properties for osteo-ligamentous spinal tissues are based on existing literature. The techniques being developed will allow pre-surgical prediction of stresses, forces and deformations in spinal tissues, rods and screws under post-operative physiological loads.
Resumo:
An electrified railway system includes complex interconnections and interactions of several subsystems. Computer simulation is the only viable means for system evaluation and analysis. This paper discusses the difficulties and requirements of effective simulation models for this specialized industrial application; and the development of a general-purpose multi-train simulator.
Resumo:
A breaker restrike is an abnormal arcing phenomenon, leading to a possible breaker failure. Eventually, this failure leads to interruption of the transmission and distribution of the electricity supply system until the breaker is replaced. Before 2008, there was little evidence in the literature of monitoring techniques based on restrike measurement and interpretation produced during switching of capacitor banks and shunt reactor banks in power systems. In 2008 a non-intrusive radiometric restrike measurement method and a restrike hardware detection algorithm were developed by M.S. Ramli and B. Kasztenny. However, the limitations of the radiometric measurement method are a band limited frequency response as well as limitations in amplitude determination. Current restrike detection methods and algorithms require the use of wide bandwidth current transformers and high voltage dividers. A restrike switch model using Alternative Transient Program (ATP) and Wavelet Transforms which support diagnostics are proposed. Restrike phenomena become a new diagnostic process using measurements, ATP and Wavelet Transforms for online interrupter monitoring. This research project investigates the restrike switch model Parameter „A. dielectric voltage gradient related to a normal and slowed case of the contact opening velocity and the escalation voltages, which can be used as a diagnostic tool for a vacuum circuit-breaker (CB) at service voltages between 11 kV and 63 kV. During current interruption of an inductive load at current quenching or chopping, a transient voltage is developed across the contact gap. The dielectric strength of the gap should rise to a point to withstand this transient voltage. If it does not, the gap will flash over, resulting in a restrike. A straight line is fitted through the voltage points at flashover of the contact gap. This is the point at which the gap voltage has reached a value that exceeds the dielectric strength of the gap. This research shows that a change in opening contact velocity of the vacuum CB produces a corresponding change in the slope of the gap escalation voltage envelope. To investigate the diagnostic process, an ATP restrike switch model was modified with contact opening velocity computation for restrike waveform signature analyses along with experimental investigations. This also enhanced a mathematical CB model with the empirical dielectric model for SF6 (sulphur hexa-fluoride) CBs at service voltages above 63 kV and a generalised dielectric curve model for 12 kV CBs. A CB restrike can be predicted if there is a similar type of restrike waveform signatures for measured and simulated waveforms. The restrike switch model applications are used for: computer simulations as virtual experiments, including predicting breaker restrikes; estimating the interrupter remaining life of SF6 puffer CBs; checking system stresses; assessing point-on-wave (POW) operations; and for a restrike detection algorithm development using Wavelet Transforms. A simulated high frequency nozzle current magnitude was applied to an Equation (derived from the literature) which can calculate the life extension of the interrupter of a SF6 high voltage CB. The restrike waveform signatures for a medium and high voltage CB identify its possible failure mechanism such as delayed opening, degraded dielectric strength and improper contact travel. The simulated and measured restrike waveform signatures are analysed using Matlab software for automatic detection. Experimental investigation of a 12 kV vacuum CB diagnostic was carried out for the parameter determination and a passive antenna calibration was also successfully developed with applications for field implementation. The degradation features were also evaluated with a predictive interpretation technique from the experiments, and the subsequent simulation indicates that the drop in voltage related to the slow opening velocity mechanism measurement to give a degree of contact degradation. A predictive interpretation technique is a computer modeling for assessing switching device performance, which allows one to vary a single parameter at a time; this is often difficult to do experimentally because of the variable contact opening velocity. The significance of this thesis outcome is that it is a non-intrusive method developed using measurements, ATP and Wavelet Transforms to predict and interpret a breaker restrike risk. The measurements on high voltage circuit-breakers can identify degradation that can interrupt the distribution and transmission of an electricity supply system. It is hoped that the techniques for the monitoring of restrike phenomena developed by this research will form part of a diagnostic process that will be valuable for detecting breaker stresses relating to the interrupter lifetime. Suggestions for future research, including a field implementation proposal to validate the restrike switch model for ATP system studies and the hot dielectric strength curve model for SF6 CBs, are given in Appendix A.
Resumo:
Purpose: The measurement of broadband ultrasonic attenuation (BUA) in cancellous bone for the assessment of osteoporosis follows a parabolic-type dependence with bone volume fraction; having minima values corresponding to both entire bone and entire marrow. Langton has recently proposed that the primary BUA mechanism may be significant phase interference due to variations in propagation transit time through the test sample as detected over the phase-sensitive surface of the receive ultrasound transducer. This fundamentally simple concept assumes that the propagation of ultrasound through a complex solid : liquid composite sample such as cancellous bone may be considered by an array of parallel ‘sonic rays’. The transit time of each ray is defined by the proportion of bone and marrow propagated, being a minimum (tmin) solely through bone and a maximum (tmax) solely through marrow. A Transit Time Spectrum (TTS), ranging from tmin to tmax, may be defined describing the proportion of sonic rays having a particular transit time, effectively describing lateral inhomogeneity of transit time over the surface of the receive ultrasound transducer. Phase interference may result from interaction of ‘sonic rays’ of differing transit times. The aim of this study was to test the hypothesis that there is a dependence of phase interference upon the lateral inhomogenity of transit time by comparing experimental measurements and computer simulation predictions of ultrasound propagation through a range of relatively simplistic solid:liquid models exhibiting a range of lateral inhomogeneities. Methods: A range of test models was manufactured using acrylic and water as surrogates for bone and marrow respectively. The models varied in thickness in one dimension normal to the direction of propagation, hence exhibiting a range of transit time lateral inhomogeneities, ranging from minimal (single transit time) to maximal (wedge; ultimately the limiting case where each sonic ray has a unique transit time). For the experimental component of the study, two unfocused 1 MHz ¾” broadband diameter transducers were utilized in transmission mode; ultrasound signals were recorded for each of the models. The computer simulation was performed with Matlab, where the transit time and relative amplitude of each sonic ray was calculated. The transit time for each sonic ray was defined as the sum of transit times through acrylic and water components. The relative amplitude considered the reception area for each sonic ray along with absorption in the acrylic. To replicate phase-sensitive detection, all sonic rays were summed and the output signal plotted in comparison with the experimentally derived output signal. Results: From qualtitative and quantitative comparison of the experimental and computer simulation results, there is an extremely high degree of agreement of 94.2% to 99.0% between the two approaches, supporting the concept that propagation of an ultrasound wave, for the models considered, may be approximated by a parallel sonic ray model where the transit time of each ray is defined by the proportion of ‘bone’ and ‘marrow’. Conclusions: This combined experimental and computer simulation study has successfully demonstrated that lateral inhomogeneity of transit time has significant potential for phase interference to occur if a phase-sensitive ultrasound receive transducer is implemented as in most commercial ultrasound bone analysis devices.
Resumo:
This paper treats the blast response of a pile foundation in saturated sand using explicit nonlinear finite element analysis, considering complex material behavior of soil and soil–pile interaction. Blast wave propagation in the soil is studied and the horizontal deformation of pile and effective stresses in the pile are presented. Results indicate that the upper part of the pile to be vulnerable and the pile response decays with distance from the explosive. The findings of this research provide valuable information on the effects of underground explosions on pile foundation and will guide future development, validation and application of computer models.