995 resultados para Acoustic Immittance Measures


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In recent years, acoustic perturbation measurement has gained clinical and research popularity due to the ease of availability of commercial acoustic analysing software packages in the market. However, because the measurement itself depends critically on the accuracy of frequency tracking from the voice signal, researchers argue that perturbation measures are not suitable for analysing dysphonic voice samples, which are aperiodic in nature. This study compares the fundamental frequency, relative amplitude perturbation, shimmer percent and noise-to-harmonic ratio between a group of dysphonic and non-dysphonic subjects. One hundred and twelve dysphonic subjects ( 93 females and 19 males) and 41 non-dysphonic subjects ( 35 females and 6 males) participated in the study. All the 153 voice samples were categorized into type I ( periodic or nearly periodic), type II ( signals with subharmonic frequencies that approach the fundamental frequency) and type III ( aperiodic) signals. Only the type I ( periodic and nearly periodic) voice signals were acoustically analysed for perturbation measures. Results revealed that the dysphonic female group presented significantly lower fundamental frequency, significantly higher relative amplitude perturbation and shimmer percent values than the non-dysphonic female group. However, none of these three perturbation measures were able to differentiate between male dysphonic and male non-dysphonic subjects. The noise-to-harmonic ratio failed to differentiate between the dysphonic and non-dysphonic voices for both gender groups. These results question the sensitivity of acoustic perturbation measures in detecting dysphonia and suggest that contemporary acoustic perturbation measures are not suitable for analysing dysphonic voice signals, which are even nearly periodic. Copyright (C) 2005 S. Karger AG, Basel.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: avaliar o desempenho em habilidades auditivas e as condições de orelha média de crianças de 4 a 6 anos de idade. MÉTODO: foram aplicados os testes de detecção sonora (audiômetro pediátrico em 20dBNA), a Avaliação Simplificada do Processamento Auditivo (ASPA) e as medidas de imitância acústica (handtymp com tom de 226Hz) em 61 crianças com média de idade de 5,65 anos. Para comparar os resultados das provas de habilidades auditivas e das medidas da imitância acústica foi aplicado o teste exato de Fisher com nível de significância de p< 0,05. RESULTADOS: houve alteração em pelo menos uma das habilidades auditivas investigadas em 24,6% das crianças. Houve alteração timpanométrica em 34,4% das crianças e 64% foram classificadas no critério "falha" para a pesquisa do reflexo acústico ispilateral. As crianças mais jovens apresentaram maior ocorrência de alterações de orelha média, mas não houve diferença estatisticamente significante entre as diferentes idades para as provas realizadas. CONCLUSÃO: as crianças mais jovens apresentaram maior ocorrência de alterações nas provas de habilidades auditivas e nas medidas de imitância acústica. Programas de investigação e acompanhamento das condições de orelha média e das habilidades auditivas em idade pré-escolar e escolar podem eliminar ou minimizar intercorrências que alterariam o desenvolvimento sócio-linguístico.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Current tympanometric norms have acknowledged the relevance of age as,in influencing factor. However, little attention has been afforded to other potentialities such its the non-pathological effects of gender, ear asymmetry, and racial heritage. This study aimed to examine normative tympanometric findings in a large sample of Chinese schoolchildren. Using a Madsen 901 Middle Ear Analyzer, data was collected from 269 children (538 ears), ranging in age from 6.2-12.7 years (mean = 9.4 years, SD = 1.7), in Jiangsu province. Descriptive statistics were calculated for the parameters of equivalent car canal volume (chi = 1.03, SD = 0.25, 90% = 0.68-1.46), peak compensated static acoustic admittance (chi = 0.58, SD = 0.34, 90% = 0.26-1.13), tympanometric width (chi = 112, SD=36, 90% = 62-156), and peak pressure (chi = -25, SD = 30, 90% = -85-+10). Statistically significant car asymmetry and grade/age effects were estabished, although differences found were minor. In comparison with past studies in Caucasian paediatric populations, the Chinese normative data displayed minimal disparities.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: The aim of this study was to investigate the effects of sub-clinical alterations on the amplitudes and slopes of the DPOAE input-output responses from subjects with previous history of middle ear dysfunction. Material/Methods: The study included 15 subjects with and 15 subjects without a history of otitis media in the last 10 years. All participants were assessed with acoustic immittance, pure-tone audiometry, and DPOAEs. For the later, I/O functions and I/O slopes were estimated at 1501, 2002, 3174, 4004 and 6384Hz. Results: No statistically significant differences were found between the 2 groups in terms of behavioral thresholds. The group with a previous history of middle ear dysfunction presented significantly lower mean DPOAE amplitudes at 2002, 3174 and 4004 Hz. In terms of DPOAE slopes, no statistically significant differences were observed at the tested frequencies, except at 3174 Hz. Conclusions: Middle ear pathologies can produce subclinical alterations that are undetectable with traditional pure-tone audiometry. The data from the present study show that reduced amplitude DPOAEs are associated with a previous history of middle ear complications. The corresponding DPOAE slopes were affected at only 1 tested frequency, suggesting that the cochlear non-linearity is preserved. Considering these results, it remains to be elucidated to what degree the DPOAE amplitude attenuation interferes with higher-order auditory tasks.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In recent years, the multiparametric approach for evaluating perceptual rating of voice quality has been advocated. This study evaluates the accuracy of predicting perceived overall severity of voice quality with a minimal set of aerodynamic, voice range profile (phonetogram), and acoustic perturbation measures. One hundred and twelve dysphonic persons (93 women and 19 men) with laryngeal pathologies and 41 normal controls (35 women and six men) with normal voices participated in this study. Perceptual severity judgement was carried out by four listeners rating the G (overall grade) parameter of the GRBAS scale.(1) The minimal set of instrumental measures was selected based on the ability of the measure to discriminate between dysphonic and normal voices, and to attain at least a moderate correlation with perceived overall severity. Results indicated that perceived overall severity was best described by maximum phonation time of sustained /a/, peak intraoral pressure of the consonant-vowel /pi/ strings production, voice range profile area, and acoustic jitter. Direct-entry discriminant function analysis revealed that these four voice measures in combination correctly predicted 67.3% of perceived overall severity levels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Axial acoustic wave propagation has been widely used in evaluating the mechanical properties of human bone in vivo. However, application of this technique to monitor soft tissues, such as tendon, has received comparatively little scientific attention. Laboratory-based research has established that axial acoustic wave transmission is not only related to the physical properties of equine tendon but is also proportional to tensile load to which it is exposed (Miles et al., 1996; Pourcelot et al., 2005). The reproducibility of the technique for in vivo measurements in human tendon, however, has not been established. The aim of this study was to evaluate the limits of agreement for repeated measures of the speed of sound (SoS) in human Achilles tendon in vivo. Methods: A custom built ultrasound device, consisting of an A-mode 1MHz emitter and two regularly spaced receivers, was used to measure the SoS in the mid-portion of the Achilles tendon in ten healthy males and ten females (mean age: 33.8 years, range 23-56 yrs; height: 1.73±0.08 m; weight: 68.4±15.3 kg). The emitter and receivers were held at fixed positions by a polyethylene frame and maintained in close contact with the skin overlying the tendon by means of elasticated straps. Repeated SoS measurements were taken with the subject prone (non-weightbearing and relaxed Achilles tendon) and during quiet bipedal and unipedal stance. In each instance, the device was detached and repositioned prior to measurement. Results: Limits of agreement for repeated SoS measures during non-weightbearing and bipedal and unipedal stance were ±53, ±28 and ±21 m/s, respectively. The average SoS in the non-weightbearing Achilles tendon was 1804±198 m/s. There was a significant increase in the average SoS during bilateral (2122±135 m/s) (P < 0.05) and unilateral (2221±79 m/s) stance (P < 0.05). Conclusions: Repeated SoS measures in human Achilles tendon were more reliable during stance than under non-weightbearing conditions. These findings are consistent with previous research in equine tendon in which lower variability in SoS was observed with increasing tensile load (Crevier-Denoix et al, 2009). Since the limits of agreement for Achilles tendon SoS are nearly 5% of the changes previously observed during walking and therapeutic heel raise exercises, acoustic wave transmission provides a promising new non-invasive method for determining tendon properties during sports and rehabilitation related activities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. In isotropic materials, the speed of acoustic wave propagation is governed by the bulk modulus and density. For tendon, which is a structural composite of fluid and collagen, however, there is some anisotropy requiring an adjustment for Poisson's ratio. This paper explores these relationships using data collected, in vivo, on human Achilles tendon and then compares estimates of elastic modulus and hysteresis against published values from in vitro mechanical tests. Methods. Measurements using conventional B-model ultrasound imaging, inverse dynamics and acoustic transmission techniques were used to determine dimensions, loading conditions and longitudinal speed of sound in the Achilles tendon during a series of isometric plantar flexion exercises against body weight. Upper and lower bounds for speed of sound versus tensile stress in the tendon were then modelled and estimates of the elastic modulus and hysteresis of the Achilles tendon derived. Results. Axial speed of sound varied between 1850 and 2090 ms-1 with a non-linear, asymptotic dependency on the level of tensile stress (5-35 MPa) in the tendon. Estimates derived for the elastic modulus of the Achilles tendon ranged between 1-2 GPa. Hysteresis derived from models of the stress-strain relationship, ranged from 3-11%. Discussion. Estimates of elastic modulus agree closely with those previously reported from direct measurements obtained via mechanical tensile tests on major weight bearing tendons in vitro [1,2]. Hysteresis derived from models of the stress-strain relationship is consistent with direct measures from various mamalian tendon (7-10%) but is lower than previous estimates in human tendon (17-26%) [3]. This non-invasive method would appear suitable for monitoring changes in tendon properties during dynamic sporting activities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Monitoring gas purity is an important aspect of gas recovery stations where air is usually one of the major impurities. Purity monitors of Katherometric type ate commercially available for this purpose. Alternatively, we discuss here a helium gas purity monitor based on acoustic resonance of a cavity at audio frequencies. It measures the purity by monitoring the resonant frequency of a cylindrical cavity filled with the gas under test and excited by conventional telephone transducers fixed at the ends. The use of the latter simplifies the design considerably. The paper discusses the details of the resonant cavity and the electronic circuit along with temperature compensation. The unit has been calibrated with helium gas of known purities. The unit has a response time of the order of 10 minutes and measures the gas purity to an accuracy of 0.02%. The unit has been installed in our helium recovery system and is found to perform satisfactorily.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In species-rich assemblages, differential utilization of vertical space can be driven by resource availability. For animals that communicate acoustically over long distances under habitat-induced constraints, access to an effective transmission channel is a valuable resource. The acoustic adaptation hypothesis suggests that habitat acoustics imposes a selective pressure that drives the evolution of both signal structure and choice of calling sites by signalers. This predicts that species-specific signals transmit best in native habitats. In this study, we have tested the hypothesis that vertical stratification of calling heights of acoustically communicating species is driven by acoustic adaptation. This was tested in an assemblage of 12 coexisting species of crickets and katydids in a tropical wet evergreen forest. We carried out transmission experiments using natural calls at different heights from the forest floor to the canopy. We measured signal degradation using 3 different measures: total attenuation, signal-to-noise ratio (SNR), and envelope distortion. Different sets of species supported the hypothesis depending on which attribute of signal degradation was examined. The hypothesis was upheld by 5 species for attenuation and by 3 species each for SNR and envelope distortion. Only 1 species of 12 provided support for the hypothesis by all 3 measures of signal degradation. The results thus provided no overall support for acoustic adaptation as a driver of vertical stratification of coexisting cricket and katydid species.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes an automatic acoustic-phonetic method for estimating voice-onset time of stops. This method requires neither transcription of the utterance nor training of a classifier. It makes use of the plosion index for the automatic detection of burst onsets of stops. Having detected the burst onset, the onset of the voicing following the burst is detected using the epochal information and a temporal measure named the maximum weighted inner product. For validation, several experiments are carried out on the entire TIMIT database and two of the CMU Arctic corpora. The performance of the proposed method compares well with three state-of-the-art techniques. (C) 2014 Acoustical Society of America

Relevância:

30.00% 30.00%

Publicador:

Resumo:

1.Understanding which environmental factors drive foraging preferences is critical for the development of effective management measures, but resource use patterns may emerge from processes that occur at different spatial and temporal scales. Direct observations of foraging are also especially challenging in marine predators, but passive acoustic techniques provide opportunities to study the behaviour of echolocating species over a range of scales. 2.We used an extensive passive acoustic data set to investigate the distribution and temporal dynamics of foraging in bottlenose dolphins using the Moray Firth (Scotland, UK). Echolocation buzzes were identified with a mixture model of detected echolocation inter-click intervals and used as a proxy of foraging activity. A robust modelling approach accounting for autocorrelation in the data was then used to evaluate which environmental factors were associated with the observed dynamics at two different spatial and temporal scales. 3.At a broad scale, foraging varied seasonally and was also affected by seabed slope and shelf-sea fronts. At a finer scale, we identified variation in seasonal use and local interactions with tidal processes. Foraging was best predicted at a daily scale, accounting for site specificity in the shape of the estimated relationships. 4.This study demonstrates how passive acoustic data can be used to understand foraging ecology in echolocating species and provides a robust analytical procedure for describing spatio-temporal patterns. Associations between foraging and environmental characteristics varied according to spatial and temporal scale, highlighting the need for a multi-scale approach. Our results indicate that dolphins respond to coarser scale temporal dynamics, but have a detailed understanding of finer-scale spatial distribution of resources.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To assess the agreement and repeatability of horizontal white-to-white (WTW) and horizontal sulcus-to-sulcus (STS) diameter measurements and use these data in combination with available literature to correct for interdevice bias in preoperative implantable collamer lens (ICL) size selection. DESIGN: Interinstrument reliability and bias assessment study. METHODS: A total of 107 eyes from 56 patients assessed for ICL implantation at our institution were included in the study. This was a consecutive series of all patients with suitable available data. The agreement and bias between WTW (measured with the Pentacam and BioGraph devices) and STS (measured with the HiScan device) were estimated. RESULTS: The mean spherical equivalent was -8.93 ± 5.69 diopters. The BioGraph measures of WTW were wider than those taken with the Pentacam (bias = 0.26 mm, P < .01), and both horizontal WTW measures were wider than the horizontal STS measures (bias >0.91 mm, P < .01). The repeatability (Sr) of STS measured with the HiScan was 0.39 mm, which was significantly reduced (Sr = 0.15 mm) when the average of 2 measures was used. Agreement between the horizontal WTW measures and horizontal STS estimates when bias was accounted for was г = 0.54 with the Pentacam and г = 0.64 with the BioGraph. CONCLUSIONS: Large interdevice bias was observed for WTW and STS measures. STS measures demonstrated poor repeatability, but the average of repeated measures significantly improved repeatability. In order to conform to the US Food and Drug Administration's accepted guidelines for ICL sizing, clinicians should be aware of and account for the inconsistencies between devices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper examines objective measures of speech production, specifically vowels. The relationship between the listener's perception of sections of the vowels with their perception of the entire vocalic utterance was examined.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper evaluates the directional effects of two hearing devices – an antique London Dome horn style device and a constructed Cupped Hand. The comparisons were made using the Quick SIN (Speech in Noise) adaptive test which measures signal-to-noise ratio loss.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper discusses a study that examined acoustic measures and the relationship to speech intelligibility of children with cochlear implants.