891 resultados para Accelerated tests


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A major aspect in geosynthetics creep analysis is the load level applied to the specimen, usually referred as a percentage of the geosynthetic ultimate tensile strength (UTS). Since both tensile and creep standard tests are performed with in-isolation specimens, they may not reproduce the possibly significant effect of soil-geosynthetic interaction. A new creep testing machine was recently developed and successfully addressed this concern. However, further developments allowed tensile tests to be performed in the same conditions used in nonconventional creep ones. This paper presents the results of nonconventional tensile tests performed with a woven biaxial polyester geogrid. They were used to define its UTS in the same conditions employed in creep tests performed with the new equipment. Despite changes in tensile curves shapes were found, the UTS from confined, accelerated and confined-accelerated tensile tests were quite similar to those obtained with standard tensile test procedure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents results of stress cracking tests performed in high density polyethylene (HDPE) geomembranes (GM). Stress cracking tests were performed in accordance to ASTM D5397: Notched Constant Tensile Load Test (NCTL) and Single Point-Notched Constant Tensile Load Test (SP-NCTL). Tests were conducted to the fresh sample at 50ºC (standard test) and at 70ºC (accelerated condition) in order to compare the SC values. Results from accelerated tests (NCTL) showed, for instance, a total economy of 390 hours (comparing load stages of 25% yield stress) to perform the tests.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Freezing of water or salt solution in concrete pores is a main cause for severe damage and significant reduction of the service life. Most of the freeze-thaw (F-T) accelerated tests measure the scaling of concrete by weighting. This paper presents complementary procedures based on the use of strain gages and ultrasonic pulse velocity (UPV) for measuring the deterioration of concrete due to freezing and thawing. These non-destructive testing (NDT) procedures are applied to two types of concretes, one susceptible to F-T damage and the other does not. The results show a good correlation between scaling and the measurements obtained with NDT. Showing NDT the advantage to detect before the damage and to perform continuous measurement

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Cracking of reinforced concrete can occur in certain environments due to rebar corrosion. The oxide layer growing around the bars introduces a pressure which may be enough to lead to the fracture of concrete. To study such an effect, the results of accelerated corrosion tests and finite ele- ment simulations are combined in this work. In previous works, a numerical model for the expansive layer, called expansive joint element , was programmed by the authors to reproduce the effect of the oxide over the concrete. In that model, the expansion of the oxide layer in stress free conditions is simulated as an uniform expansion perpendicular to the steel surface. The cracking of concrete is simulated by means of finite elements with an embedded adaptable cohesive crack that follow the standard cohesive model. In the present work, further accelerated tests with imposed constant cur- rent have been carried out on the same type of specimens tested in previous works (with an embedded steel tube), while measuring, among other things, the main-crack mouth opening. Then, the tests have been numerically simulated using the expansive joint element and the tube as the corroding electrode (rather than a bar). As a result of the comparison of numerical and experimental results, both for the crack mouth opening and the crack pattern, new insight is gained into the behavior of the oxide layer. In particular, quantitative assessment of the oxide expansion relation is deduced from the ex- periments, and a narrower interval for the shear stiffness of the oxide layer is obtained, which could not be achieved using bars as the corroding element, because in that case the numerical results were insensitive to the shear stiffness of the oxide layer within many orders of magnitude

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In most real-life environments, mechanical or electronic components are subjected to vibrations. Some of these components may have to pass qualification tests to verify that they can withstand the fatigue damage they will encounter during their operational life. In order to conduct a reliable test, the environmental excitations can be taken as a reference to synthesize the test profile: this procedure is referred to as “test tailoring”. Due to cost and feasibility reasons, accelerated qualification tests are usually performed. In this case, the duration of the original excitation which acts on the component for its entire life-cycle, typically hundreds or thousands of hours, is reduced. In particular, the “Mission Synthesis” procedure lets to quantify the induced damage of the environmental vibration through two functions: the Fatigue Damage Spectrum (FDS) quantifies the fatigue damage, while the Maximum Response Spectrum (MRS) quantifies the maximum stress. Then, a new random Power Spectral Density (PSD) can be synthesized, with same amount of induced damage, but a specified duration in order to conduct accelerated tests. In this work, the Mission Synthesis procedure is applied in the case of so-called Sine-on-Random vibrations, i.e. excitations composed of random vibrations superimposed on deterministic contributions, in the form of sine tones typically due to some rotating parts of the system (e.g. helicopters, engine-mounted components, …). In fact, a proper test tailoring should not only preserve the accumulated fatigue damage, but also the “nature” of the excitation (in this case the sinusoidal components superimposed on the random process) in order to obtain reliable results. The classic time-domain approach is taken as a reference for the comparison of different methods for the FDS calculation in presence of Sine-on-Random vibrations. Then, a methodology to compute a Sine-on-Random specification based on a mission FDS is presented.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cost-effective organic sensitizers will play a pivotal role in the future large-scale production and application of dye-sensitized solar cells. Here we report two new organic D-pi-A dyes featuring electron-rich 3,4-ethylenedioxythiophene- and 2,2'-bis(3,4-ethylenedioxythiophene)-conjugated linkers, showing a remarkable red-shifting of photocurrent action spectra compared with their thiophene and bithiophene counterparts. On the basis of the 3-f{5'-[N,N-bis(9,9-dimethylfluorene-2-yl)phenyl]-2,2'-bis(3,4-ethylenedioxythiophene)-5-yl}2-cyanoacrylic acid dye, we have set a new efficiency record of 7.6% for solvent-free dye-sensitized solar cells based on metal-free organic sensitizers. Importantly, the cell exhibits an excellent stability, keeping over 92% of its initial efficiency after 1000 h accelerated tests under full sunlight soaking at 60 degrees C. This achievement will considerably encourage further design and exploration of metal-free organic dyes for higher performance dye-sensitized solar cells.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Anisotropic conductive film (ACF) which consists of an adhesive epoxy matrix and randomly distributed conductive particles are widely used as the connection material for electronic devices with high I/O counts. However, for the semiconductor industry the reliability of the ACF is still a major concern due to a lack of experimental reliability data. This paper reports the investigations into the moisture-induced failures in Flip-Chip-on-Flex interconnections with Anisotropic Conductive Films (ACFs). Both experimental and modeling methods were applied. In the experiments, the contact resistance was used as a quality indicator and was measured continuously during the accelerated tests (autoclave tests). The temperature, relative humidity and the pressure were set at 121°C, 100%RH, and 2atm respectively. The contact resistance of the ACF joints increased during the tests and nearly 25% of the joints were found to be open after 168 hours’ testing time. Visible conduction gaps between the adhesive and substrate pads were observed. Cracks at the adhesive/flex interface were also found. For a better understanding of the experimental results, 3-D Finite Element (FE) models were built and a macro-micro modeling method was used to determine the moisture diffusion and moisture-induced stresses inside the ACF joints. Modeling results are consistent with the findings in the experimental work.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper reports the investigations into the moisture induced failures in flip-chip-on-flex interconnections with anisotropic conductive films (ACF). Both experimental and modeling methods were applied. In the experiments, the contact resistance was used as a quality indicator and was measured continuously during the accelerated tests (autoclave tests). The temperature, relative humidity and the pressure were set at 121°C, 100%RH, 1atm respectively. The contact resistance of the ACF joints increased during the tests and nearly 25% of the joints were found to be open after 168 hours' testing time. Visible conduction gaps between the adhesive and substrate pads were observed. Cracks at the adhesive/flex interface were also found. It is believed that the swelling effect of the adhesive and the water penetration along the adhesive/flex interface are the main causes of this contact degradation. Another finding from the experimental work was that the ACF interconnections that had undergone the reflow treatment were more sensitive to the moisture and showed worse reliability during the tests. For a better understanding of the experimental results, 3D finite element (FE) models were built and a macro-micro modeling method was used to determine the moisture diffusion and moisture-induced stresses inside the ACF joints. Modeling results are consistent with the findings in the experimental work.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

It is analyzed through the concepts of tribology and mechanical contact and damage the suggestion of implementing a backup system for traction and passage of Pipeline Inspection Gauge (Pig) from the inside of pipelines. In order to verify the integrity of the pipelines, it is suggested the possibility of displacement of such equipment by pulling wires with steel wires. The physical and mechanical characteristics of this method were verified by accelerated tests in the laboratory in a tribological pair, wire versus a curve 90. It also considered the main mechanisms of wear of a sliding system with and without lubricant, in the absence and presence of contaminants. To try this, It was constructed a test bench able to reproduce a slip system, work on mode back-and-forth ("reciprocation"). It was used two kinds of wires, a galvanized steel and other stainless steel and the results achieved using the two kinds of steel cables were compared. For result comparative means, it was used steel cables with and without coating of Poly Vinyl Chloride (PVC). The wires and the curves of the products were characterized using metallographic analysis, microhardness Vickers tests, X-ray diffraction (XRD), X-Ray Refraction (XRF) and tensile tests. After the experiments were analyzed some parameters that have been measurable, it demonstrates to the impracticality of this proposed method, since the friction force and the concept of alternating request at the contact between the strands of wire and the inner curves that are part ducts caused severe wear. These types of wear are likely to cause possible failures in future products and cause fluid leaks

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Civil - FEIS

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The needs of customers to improve machinery in recent years have driven tractor manufacturers to reduce product life and development costs. The most significant efforts have concentrated on the attempt to decrease the costs of the experimental testing sector. The validation of the tractor prototypes are presently performed with a replication of a particularly unfavourable condition a defined number of times. These laboratory tests do not always faithfully reproduce the real use of the tractor. Therefore, field tests are also carried out to evaluate the prototype during real use, but it is difficult to perform such tests for a period of time long enough to reproduce tractor life usage. In this context, accelerated tests have been introduced in the automotive sector, producing a certain damage to the structure in a reduced amount of time. The goal of this paper is to define a methodology for the realization of accelerated structural tests on a tractor, through the reproduction of real customer tractor usage. A market analysis was performed on a 80 kW power tractor and a series of measures were then taken to simulate the real use of the tractor. Subsequently, the rainflow matrixes of the signals were extrapolated and used to estimate the tractor loadings for 10 years of tractor life. Finally these loadings were reproduced on testing grounds with special road pavements. The results obtained highlight the possibility of reproducing field loadings during road driving on proving grounds (PGs), but the use of two field operations is also necessary. The global acceleration factor obtained in this first step of the methodology is equal to three.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aluminum coatings were applied to 2024-T3 and 7075-T6 aluminum alloys via the Cold Spray process. The coatings were applied to substrateswith various surface preparation and Cold Spray carrier gas combinations. Some samples were coated with an additional sealant with and without a chromate conversion layer. An exhaustive corrosion analysis was then performed which utilized a number of long termand accelerated tests in order to characterize the corrosion protection of the coatings.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

SUMMARY Concentration Photovoltaic Systems (CPV) have been proposed as an alternative to conventional systems. During the last years, there has been a boom of the CPV industry caused by the technological progress in all the elements of the system. and mainly caused by the use of multijunction solar cells based on III-V semiconductors, with efficiencies exceeding to 43%. III-V solar cells have been used with high reliability results in a great number of space missions without concentration. However, there are no previous results regarding their reliability in concentration terrestrial applications, where the working conditions are completely different. This lack of experience, together with the important industrial interest, has generated the need to evaluate the reliability of the cells. For this reason, nowadays there are several research centers around the undertaking this task. The evaluation of the reliability of this type of devices by means of accelerated tests is especially problematic when they work at medium or high concentration, because it is practically impossible to emulate real working conditions of the cell inside climatic chambers. In fact, as far as we know, the results that appear in this Thesis are the first estimating the Activation Energy of the failure mechanism involved, as well as the warranty of the III-V concentrator solar cells tested here. To evaluate the reliability of III-V very high concentrator solar cells by means of accelerated tests, a variety of activities, described in this Thesis have been carried out. The First Part of the memory presents the theoretical part of the Doctoral Thesis. After the Introduction, chapter 2 presents the state of the art in degradation and reliability of CPV systems and solar cells. Chapter 3 introduces some reliability definitions and the application of specific statistical functions to the evaluation of the reliability and parameters. From these functions, important parameters will be calculated to be used later in the experimental results of Thesis. The Second Part of the memory contains the experimental. Chapter 4 shows the types of accelerated tests and the main goals pursuit with them when carried out over CPV systems and solar cells. In order to evaluate quantitatively the reliability of the III-V concentrator solar cells used in these tests, some modifications have been introduced which discussion will be tackled here. Based on this analysis the working plan of the tests carried out in this Doctoral Thesis is presented. Chapter 5 presents a new methodology as well as the necessary instrumentation to carry out the tests described here. This new methodology takes into account the adaptation, improvement and novel techniques needed to test concentrator solar cells. The core of this memory is chapter 6, which presents the results of the characterization of the cells during the accelerated life tests and the analysis of the aforementioned results with the purpose of getting quantitative values of reliability in real working conditions. The acceleration factor of the accelerated life tests, under nominal working conditions has been calculated. Accordingly, the validity of the methodology as well as the calculations based on the reliability assessment, have also been demonstrated. Finally, quantitative values of degradation, reliability and warranty of the solar cells under field nominal working conditions have been calculated. With the development of this Doctoral Thesis the reliability of very high concentrator GaAs solar cells of small area has been evaluated. It is very interesting to generalize the procedures described up to this point to III-V multijunction solar cells of greater area. Therefore, chapter 7 develops this generalization and introduces also a useful thermal modeling by means of finite elements of the test cells’ circuits. In the last chapter, the summary of the results and the main contributions of this Thesis are outlined and future research activities are identified. RESUMEN Los Sistemas Fotovoltaicos de Concentración (SFC) han sido propuestos como una alternativa a los sistemas convencionales de generación de energía. Durante los últimos años ha habido un auge de los SFC debido a las mejoras tecnológicas en todos los elementos del sistema, y principalmente por el uso de células multiunión III-V que superan el 43% de rendimiento. Las células solares III-V han sido utilizadas con elevada fiabilidad en aplicaciones espaciales sin concentración, pero no existe experiencia de su fiabilidad en ambiente terrestre a altos niveles de concentración solar. Esta falta de experiencia junto al gran interés industrial ha generado la necesidad de evaluar la fiabilidad de las células, y actualmente hay un significativo número de centros de investigación trabajando en esta área. La evaluación de la fiabilidad de este tipo de dispositivos mediante ensayos acelerados es especialmente problemática cuando trabajan a media o alta concentración por la casi imposibilidad de emular las condiciones de trabajo reales de la célula dentro de cámaras climáticas. De hecho, que sepamos, en los resultados de esta Tesis se evalúa por primera vez la Energía de Activación del mecanismo de fallo de las células, así como la garantía en campo de las células de concentración III-V analizadas. Para evaluar la fiabilidad de células solares III-V de muy alta concentración mediante ensayos de vida acelerada se han realizado diversas actividades que han sido descritas en la memoria de la Tesis. En la Primera Parte de la memoria se presenta la parte teórica de la Tesis Doctoral. Tras la Introducción, en el capítulo 2 se muestra el estado del arte en degradación y fiabilidad de células y Sistemas Fotovoltaicos de Concentración. En el capítulo 3 se exponen de forma resumida las definiciones de fiabilidad y funciones estadísticas que se utilizan para la evaluación de la fiabilidad y sus parámetros, las cuales se emplearán posteriormente en los ensayos descritos en este Tesis. La Segunda Parte de la memoria es experimental. En el capítulo 4 se describen los tipos y objetivos de los ensayos acelerados actualmente aplicados a SFC y a las células, así como las modificaciones necesarias que permitan evaluar cuantitativamente la fiabilidad de las células solares de concentración III-V. En base a este análisis se presenta la planificación de los trabajos realizados en esta Tesis Doctoral. A partir de esta planificación y debido a la necesidad de adaptar, mejorar e innovar las técnicas de ensayos de vida acelerada para una adecuada aplicación a este tipo de dispositivos, en el capítulo 5 se muestra la metodología empleada y la instrumentación necesaria para realizar los ensayos de esta Tesis Doctoral. El núcleo de la memoria es el capítulo 6, en él se presentan los resultados de caracterización de las células durante los ensayos de vida acelerada y el análisis de dichos resultados con el objetivo de obtener valores cuantitativos de fiabilidad en condiciones reales de trabajo. Se calcula el Factor de Aceleración de los ensayos acelerados con respecto a las condiciones nominales de funcionamiento a partir de la Energía de Activación obtenida, y se demuestra la validez de la metodología y cálculos empleados, que son la base de la evaluación de la fiabilidad. Finalmente se calculan valores cuantitativos de degradación, fiabilidad y garantía de las células en condiciones nominales en campo durante toda la vida de la célula. Con el desarrollo de esta Tesis Doctoral se ha evaluado la fiabilidad de células III-V de área pequeña, pero es muy interesante generalizar los procedimientos aquí desarrollados para las células III-V comerciales de área grande. Por este motivo, en el capítulo 7 se analiza dicha generalización, incluyendo el modelado térmico mediante elementos finitos de los circuitos de ensayo de las células. En el último capítulo se realiza un resume del trabajo y las aportaciones realizadas, y se identifican las líneas de trabajo a emprender en el futuro.