999 resultados para Abusive use of linearity


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este estudio analiza las relaciones implicativas entre las estrategias usadas por 136 estudiantes de primer curso de educación secundaria en la resolución de problemas lineales y no lineales. En primer lugar, se describen las estrategias ocupadas por los alumnos y después, empleando el software CHIC, se identifican sus relaciones implicativas. Los resultados muestran que es importante que los estudiantes comprendan la idea de razón para que sean capaces de identificar las situaciones lineales; de igual manera, aportan información sobre los posibles precursores del desarrollo del razonamiento proporcional en los estudiantes de educación secundaria.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The most common techniques for stress analysis/strength prediction of adhesive joints involve analytical or numerical methods such as the Finite Element Method (FEM). However, the Boundary Element Method (BEM) is an alternative numerical technique that has been successfully applied for the solution of a wide variety of engineering problems. This work evaluates the applicability of the boundary elem ent code BEASY as a design tool to analyze adhesive joints. The linearity of peak shear and peel stresses with the applied displacement is studied and compared between BEASY and the analytical model of Frostig et al., considering a bonded single-lap joint under tensile loading. The BEM results are also compared with FEM in terms of stress distributions. To evaluate the mesh convergence of BEASY, the influence of the mesh refinement on peak shear and peel stress distributions is assessed. Joint stress predictions are carried out numerically in BEASY and ABAQUS®, and analytically by the models of Volkersen, Goland, and Reissner and Frostig et al. The failure loads for each model are compared with experimental results. The preparation, processing, and mesh creation times are compared for all models. BEASY results presented a good agreement with the conventional methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Ethylglucuronide (EtG) is a direct and specific metabolite of ethanol. Its determination in hair is of increasing interest for detecting and monitoring alcohol abuse. The quantification of EtG in hair requires analytical methods showing highest sensitivity and specificity. We present a fully validated method based on gas chromatography-negative chemical ionization tandem mass spectrometry (GC-NCI-MS/MS). The method was validated using French Society of Pharmaceutical Sciences and Techniques (SFSTP) guidelines which are based on the determination of the total measurement error and accuracy profiles. Methods: Washed and powdered hair is extracted in water using an ultrasonic incubation. After purification by Oasis MAX solid phase extraction, the derivatized EtG is detected and quantified by GC-NCI-MS/MS method in the selected reaction monitoring mode. The transitions m/z 347 / 163 and m/z 347 / 119 were used for the quantification and identification of EtG. Four quality controls (QC) prepared with hair samples taken post mortem from 2 subjects with a known history of alcoholism were used. A proficiency test with 7 participating laboratories was first run to validate the EtG concentration of each QC sample. Considering the results of this test, these samples were then used as internal controls for validation of the method. Results: The mean EtG concentrations measured in the 4 QC were 259.4, 130.4, 40.8, and 8.4 pg/mg hair. Method validation has shown linearity between 8.4 and 259.4 pg/mg hair (r2 > 0.999). The lower limit of quantification was set up at 8.4 pg/mg. Repeatability and intermediate precision were found less than 13.2% for all concentrations tested. Conclusion: The method proved to be suitable for routine analysis of EtG in hair. GC-NCI-MS/MS method was then successfully applied to the analysis of EtG in hair samples collected from different alcohol consumers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: to assess alcohol intake in the bariatric surgery pre and postoperative periods. METHODS: Patients were interviewed atSurgery Clinic of the Hospital das Clínicas da Universidade Federal de Pernambuco - HC/UFPE (Brazil) from July 2011 to March 2012. We analyzed socioeconomic, anthropometric and clinical variables. We used the Alcohol Use Disorders Identification Test (AUDIT C). RESULTS: One hundred nineteen patients were enrolled (mean age: 41.23+11.30 years), with a predominance of the female gender (83.2%), non-Caucasian race (55%), married individuals or in a stable union (65.5%), with a high school education (40.3%)and active in the job market (37%). Weight and body mass index (BMI) were 128.77+25.28Kg and 49.09+9.26Kg/m2,respectively in the preoperative period (class II obesity) and 87.19+19.16Kg and 33.04+6.21Kg/m2, respectively in the postoperative period (class I obesity) (p<0.001). Hypertension was the most frequent disease in the pre (66.6%) and postoperative (36.5%) periods. The prevalence of alcohol use was 26.6% in the preoperative period, of which 2.2% of high risk, and 35.1% in the postoperative period, of which 1.4% of probable dependence; this difference did not achieve statistical significance (p=0.337). CONCLUSION: The prevalence of abusive alcohol intake and/or probable dependence was low in both the pre and postoperative periods, with little evidence of risky consumption among the patients submitted to bariatric surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The DNA extraction is a critical step in Genetically Modified Organisms analysis based on real-time PCR. In this study, the CTAB and DNeasy methods provided good quality and quantity of DNA from the texturized soy protein, infant formula, and soy milk samples. Concerning the Certified Reference Material consisting of 5% Roundup Ready® soybean, neither method yielded DNA of good quality. However, the dilution test applied in the CTAB extracts showed no interference of inhibitory substances. The PCR efficiencies of lectin target amplification were not statistically different, and the coefficients of correlation (R²) demonstrated high degree of correlation between the copy numbers and the threshold cycle (Ct) values. ANOVA showed suitable adjustment of the regression and absence of significant linear deviations. The efficiencies of the p35S amplification were not statistically different, and all R² values using DNeasy extracts were above 0.98 with no significant linear deviations. Two out of three R² values using CTAB extracts were lower than 0.98, corresponding to lower degree of correlation, and the lack-of-fit test showed significant linear deviation in one run. The comparative analysis of the Ct values for the p35S and lectin targets demonstrated no statistical significant differences between the analytical curves of each target.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A test that is rapid, simple, accurate, not expensive, gives rapid results, and is sensitive enough to detect low levels of microorganisms would be the most suitable for food industry routine laboratories, or even for a public health laboratories. A ready-to-use alternative, commercially available method is the PetrifilmTM EB method. The aim of this study was to evaluate whether there is a statistically significant difference between the conventional methods based on Violet Red Bile Glucose Agar and the alternative 3M TM Petrifilm (EB) method for the enumeration of Enterobacteriaceae in poultry carcasses. This study also assessed whether the alternative method showed ability to produce results that were directly proportional to the concentration of the target (approximately 270 colony-forming unit.mL-1). A total of 120 poultry carcasses samples showed a significant difference (p < 0.05) between the populations obtained by the two methods, and the conventional method showed low proportionality between the dilutions. On the other hand, the PetrifilmTM EB quantification system showed the capacity to produce results that are proportional to the concentration of the analyte in samples in the concentration range from 1 to 256 colony-forming unit.mL-1.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A large number of evidences correlate elevated levels of homocysteine (Hcys) with a higher cardiovascular diseases (CVDs) risk, especially, atherosclerosis. Similarly, abnormal low levels of the vitamins B6, B9 and B12 are associated to an instability in the methionine cycle with an over production of Hcys. Thus, biomedical sciences are looking forward for a cheaper, faster, precise and accurate analytical methodology to quantify these compounds in a suitable format for the clinical environment. Therefore the objective of this study was the development of a simple, inexpensive and appropriate methodology to use at the clinical level. To achieve this goal, a procedure integrating a digitally controlled (eVol®) microextraction by packed sorbent (MEPS) and an ultra performance liquid chromatography (UPLC) coupled to a photodiode array detector (PDA) was developed to identify and quantify Hcys vitamins B6, B9 and B12. Although different conditions were assayed, we were not able to combine Hcys with the vitamins in the same analytical procedure, and so we proceeded to the optimization of two methods differing only in the composition of the gradient of the mobile phase and the injected volume. It was found that MEPS did not bring any benefit to the quantification of the Hcys in the plasma. Therefore, we developed and validate an alternative method that uses the direct injection of treated plasma (reduced and precipitated). This same method was evaluated in terms of selectivity, linearity, limit of detection (LOD), limit of quantification (LOQ), matrix effect and precision (intra-and inter-day) and applied to the determination of Hcys in a group composed by patients presenting augmented CVD risk. Good results in terms of selectivity and linearity (R2> 0.9968) were obtained, being the values of LOD and LOQ 0.007 and 0.21 mol / L, respectively. The intra-day precision (1.23-3.32%), inter-day precision (5.43-6.99%) and the recovery rate (82.5 to 93.1%) of this method were satisfactory. The matrix effect (>120%) was, however, higher than we were waiting for. Using this methodology it was possible to determine the amount of Hcys in real plasma samples from individuals presenting augmented CVD risk. Regarding the methodology developed for vitamins, despite the optimization of the extraction technique and the chromatographic conditions, it was found that the levels usually present in plasma are far below the sensitivity we obtained. Therefore, further optimizations of the methodology developed are needed. As conclusion, part of the objectives of this study was achieved with the development of a quick, simple and cheaper method for the quantification of Hcys.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to provide information that may help researchers to understand the main cause(s) of differences in bull fertility frequently observed in field trials, this study aimed to investigate conception rates as well as several in vitro sperm characteristics of different sires of unknown fertility utilized in a Timed-AI (TAI) program. Suckled Nelore cows submitted to the same TAI protocol were allocated into eight breeding groups of approximately 120 animals each. Frozen semen doses from three Angus bulls and three different batches from each bull were utilized. Approximately 100 doses from each batch were used in TAI. Sires, batches and AI technicians were equally distributed across breeding groups. Cows were examined for pregnancy diagnosis 40 d after TAI. For in vitro sperm analyses, the same thawing procedure was repeated in the laboratory to mimic field conditions. The following in vitro sperm characteristics were assessed: computerized motility, thermal resistance, plasma and acrosomal membrane integrity, lipid peroxidation, morphology, morphometry and chromatin structure. No effect of breeding group, body condition score, AI technician and sire was observed. However, some significant differences among bulls were detected in laboratory analyses. Semen from sire presenting numerically lower (P > 0.05) pregnancy/AI also presented lower (P < 0.05) values in all sperm characteristics analyzed in thermal resistance test at 4 h (Total Motility, Progressive Motility, Average Path Velocity, Straight-Line Velocity, Curvilinear Velocity, Amplitude of Lateral Head Displacement, Beat Cross Frequency, Straightness, Linearity, and Percentage of Rapidly Moving Cells), higher (P < 0.05) Major and Total Defects in sperm morphological test, lower (P < 0.05) Length, Ellipticity and Fourier parameter (Fourier 0) in sperm morphometric analysis as well as higher (P < 0.05) chromatin heterogeneity. It was concluded that, although no bull effect was observed in the field experiment, the sire that presented numerically lower pregnancy/AI also presented lower semen quality according to the laboratory analyses performed. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A large number of evidences correlate elevated levels of homocysteine (Hcys) with a higher cardiovascular diseases (CVDs) risk, especially, atherosclerosis. Similarly, abnormal low levels of the vitamins B6, B9 and B12 are associated to an instability in the methionine cycle with an over production of Hcys. Thus, biomedical sciences are looking forward for a cheaper, faster, precise and accurate analytical methodology to quantify these compounds in a suitable format for the clinical environment. Therefore the objective of this study was the development of a simple, inexpensive and appropriate methodology to use at the clinical level. To achieve this goal, a procedure integrating a digitally controlled (eVol®) microextraction by packed sorbent (MEPS) and an ultra performance liquid chromatography (UPLC) coupled to a photodiode array detector (PDA) was developed to identify and quantify Hcys vitamins B6, B9 and B12. Although different conditions were assayed, we were not able to combine Hcys with the vitamins in the same analytical procedure, and so we proceeded to the optimization of two methods differing only in the composition of the gradient of the mobile phase and the injected volume. It was found that MEPS did not bring any benefit to the quantification of the Hcys in the plasma. Therefore, we developed and validate an alternative method that uses the direct injection of treated plasma (reduced and precipitated). This same method was evaluated in terms of selectivity, linearity, limit of detection (LOD), limit of quantification (LOQ), matrix effect and precision (intra-and inter-day) and applied to the determination of Hcys in a group composed by patients presenting augmented CVD risk. Good results in terms of selectivity and linearity (R2> 0.9968) were obtained, being the values of LOD and LOQ 0.007 and 0.21 mol / L, respectively. The intra-day precision (1.23-3.32%), inter-day precision (5.43-6.99%) and the recovery rate (82.5 to 93.1%) of this method were satisfactory. The matrix effect (>120%) was, however, higher than we were waiting for. Using this methodology it was possible to determine the amount of Hcys in real plasma samples from individuals presenting augmented CVD risk. Regarding the methodology developed for vitamins, despite the optimization of the extraction technique and the chromatographic conditions, it was found that the levels usually present in plasma are far below the sensitivity we obtained. Therefore, further optimizations of the methodology developed are needed. As conclusion, part of the objectives of this study was achieved with the development of a quick, simple and cheaper method for the quantification of Hcys.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Few studies have evaluated the profile of use of disease modifying drugs (DMD) in Brazilian patients with spondyloarthritis (SpA). A common research protocol was applied prospectively in 1505 patients classified as SpA by criteria of the European Spondyloarthropathies Study Group (ESSG), followed at 29 referral centers in Rheumatology in Brazil. Demographic and clinical variables were obtained and evaluated, by analyzing their correlation with the use of DMDs methotrexate (MTX) and sulfasalazine (SSZ). At least one DMD was used by 73.6% of patients: MTX by 29.2% and SSZ by 21.7%, while 22.7% used both drugs. The use of MTX was significantly associated with peripheral involvement, and SSZ was associated with axial involvement, and the two drugs were more administered, separately or in combination, in the mixed involvement (p < 0.001). The use of a DMD was significantly associated with Caucasian ethnicity (MTX , p = 0.014), inflammatory back pain (SSZ, p = 0.002) , buttock pain (SSZ, p = 0.030), neck pain (MTX, p = 0.042), arthritis of the lower limbs (MTX, p < 0.001), arthritis of the upper limbs (MTX, p < 0.001), enthesitis (p = 0.007), dactylitis (MTX, p < 0.001), inflammatory bowel disease (SSZ, p < 0.001) and nail involvement (MTX, p < 0.001). The use of at least one DMD was reported by more than 70% of patients in a large cohort of Brazilian patients with SpA, with MTX use more associated with peripheral involvement and the use of SSZ more associated with axial involvement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To verify whether fluorescence in situ hybridization (FISH) of cells from the buccal epithelium could be employed to detect cryptomosaicism with a 45,X lineage in 46,XY patients. Samples of nineteen 46,XY healthy young men and five patients with disorders of sex development (DSD), four 45,X/46,XY and one 46,XY were used. FISH analysis with X and Y specific probes on interphase nuclei from blood lymphocytes and buccal epithelium were analyzed to investigate the proportion of nuclei containing only the signal of the X chromosome. The frequency of nuclei containing only the X signal in the two tissues of healthy men did not differ (p = 0.69). In all patients with DSD this frequency was significantly higher, and there was no difference between the two tissues (p = 0.38), either. Investigation of mosaicism with a 45,X cell line in patients with 46,XY DSD or sterility can be done by FISH directly using cells from the buccal epithelium.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To evaluate the safety of electrocautery for coagulation during Caesarean sections. A randomized, controlled, clinical pilot study was performed at a university maternity hospital. After admission for delivery and decision to perform a C-section, volunteers were randomized to either the intervention group (use of electrocautery for coagulation) or nonintervention group. The women were examined at the time of postpartum discharge (day 3), at days 7 to 10, and again at days 30 to 40 for signs of infection, hematoma, seroma, or dehiscence. Data were analyzed using an intention-to-treat analysis, and risk ratios were calculated. No significant differences were found between the two groups. Only 2.8% of patients in the intervention group developed surgical wound complications during hospitalization. However, 7 to 10 days following discharge, these rates reached 23.0% and 15.4% in the intervention and nonintervention groups, respectively (RR = 1.50, 95% CI = 0.84-2.60). Further studies should confirm whether the use of electrocautery for coagulation does not increase the risk of surgical wound complications in patients undergoing Caesarean sections.