76 resultados para Absorptivity.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

An improved procedure is proposed for determination of the pesticide carbaryl in natural waters based on double cloud point extraction. The clean up step was carried out only with Triton X-114 in alkaline medium in order to avoid the use of toxic organic solvents as well as to minimise waste generation. Cloud point preconcentration of the product of the reaction of the analyte with p-aminophenol and cetyltrimethylammonium bromide was explored to increase sensitivity and improve the detection limit. Linear response was achieved within 10 and 500 mu g L-1 and the apparent molar absorptivity was estimated as 4.6 x 105 L mol-1 cm-1. The detection limit was estimated as 7 mu g L-1 at the 99.7% confidence level and the coefficient of variation was 3.4% (n = 8). Recoveries within 91 and 99% were estimated for carbaryl spiked water samples. The results obtained for natural water samples were in agreement with those achieved by the batch of spectrophotometric procedure at the 95% confidence level. The proposed procedure is then a simple, fast, inexpensive and greener alternative for carbaryl determination.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The CO2-laser-MAG hybrid welding process has been shown to be a productive choice for the welding industry, being used in e.g. the shipbuilding, pipe and beam manufacturing, and automotive industries. It provides an opportunity to increase the productivity of welding of joints containing air gaps compared with autogenous laser beam welding, with associated reductions in distortion and marked increases in welding speeds and penetration in comparison with both arc and autogenous laser welding. The literature study indicated that the phenomena of laser hybrid welding are mostly being studied using bead-on-plate welding or zero air gap configurations. This study shows it very clearly that the CO2 laser-MAG hybrid welding process is completely different, when there is a groove with an air gap. As in case of industrial use it is excepted that welding is performed for non-zero grooves, this study is of great importance for industrial applications. The results of this study indicate that by using a 6 kW CO2 laser-MAG hybrid welding process, the welding speed may also be increased if an air gap is present in the joint. Experimental trials indicated that the welding speed may be increased by 30-82% when compared with bead-on-plate welding, or welding of a joint with no air gap i.e. a joint prepared as optimum for autogenous laser welding. This study demonstrates very clearly, that the separation of the different processes, as well as the relative configurations of the processes (arc leading or trailing) affect welding performance significantly. These matters influence the droplet size and therefore the metal transfer mode, which in turn determined the resulting weld quality and the ability to bridge air gaps. Welding in bead-onplate mode, or of an I butt joint containing no air gap joint is facilitated by using a leading torch. This is due to the preheating effect of the arc, which increases the absorptivity of the work piece to the laser beam, enabling greater penetration and the use of higher welding speeds. With an air gap present, air gap bridging is more effectively achieved by using a trailing torch because of the lower arc power needed, the wider arc, and the movement of droplets predominantly towards the joint edges. The experiments showed, that the mode of metal transfer has a marked effect on gap bridgeability. Transfer of a single droplet per arc pulse may not be desirable if an air gap is present, because most of the droplets are directed towards the middle of the joint where no base material is present. In such cases, undercut is observed. Pulsed globular and rotational metal transfer modes enable molten metal to also be transferred to the joint edges, and are therefore superior metal transfer modes when bridging air gaps. It was also found very obvious, that process separation is an important factor in gap bridgeability. If process separation is too large, the resulting weld often exhibits sagging, or no weld may be formed at all as a result of the reduced interaction between the component processes. In contrast, if the processes are too close to one another, the processing region contains excess molten metal that may create difficulties for the keyhole to remain open. When the distance is optimised - i.e. a separation of 0-4 mm in this study, depending on the welding speed and beam-arc configuration - the processes act together, creating beneficial synergistic effects. The optimum process separation when using a trailing torch was found to be shorter (0-2 mm) than when a leading torch is used (2-4 mm); a result of the facilitation of weld pool motion when the latter configuration is adopted. This study demonstrates, that the MAG process used has a strong effect on the CO2-laser-MAG hybrid welding process. The laser beam welding component is relatively stable and easy to manage, with only two principal processing parameters (power and welding speed) needing to be adjusted. In contrast, the MAG process has a large number of processing parameters to optimise, all of which play an important role in the interaction between the laser beam and the arc. The parameters used for traditional MAG welding are often not optimal in achieving the most appropriate mode of metal transfer, and weld quality in laser hybrid welding, and must be optimised if the full range of benefits provided by hybrid welding are to be realised.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple and low cost flow cell is proposed for measurements by solid-phase spectrophotometry employing a conventional spectrophotometer. The flow cell geometry allows the employment of a large amount of the solid support without causing both excessive attenuation of the radiation beam and increasing of the back-pressure. The adaptation of the flow cell in the optical path of the spectrophotometer in order to increase the precision is discussed. The flow cell characteristics were demonstrated by measurements of Co(II), employing 1-(2-tiazolylazo)-2-naphthol (TAN) immobilized on C18 bonded silica as solid support. The apparent molar absorptivity and coefficient of variation were estimated as 1.86 x 10(5) L mol-1 cm-1 and 1.4 % (n=15). A sample throughput of 40 determinations per hour and a detection limit of 15 mug L-1 (99.7 % confidence level) were achieved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study reports details of the stoichiometric characterization of the mixed complex system, V(H2O2)PAR, formed when vanadium adequately reacts with hydrogen peroxide and with 4-(2-Pyridilazo)Resorcinol. Also the presence of polynuclear species was investigated in order to elucidate about unambiguous assignment of the molar absorptivity, stability constant and composition of the complex. Two mathematical treatments methods of the experimental results were employed. From the results it can be concluded that this system corresponds to a mononuclear complex with 1:1:1 stoichiometry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Biodiesel can contain unsaturated fatty acids, which are susceptible to oxidation, being able to change into polymerized compounds. In this work biodiesel was characterized according to physical-chemistry parameters and the antioxidant activity of butylated hydroxyanisole (BHA), butylated hydroxytoluene (BHT) and tert-butylhydroquinone (TBHQ) added to biofuel was analyzed. Biodiesel was submitted to accelerate oxidation in the Schaal oven test, and peroxide value was analyzed.The absorptivity values at 232 nm and 270 nm and oxidative stability in Rancimat®were determined. It was observed that TBHQ presented superior antioxidant activity than BHT and BHA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple, fast and sensitive spectrophotometric method for the determination of cefaclor in pharmaceutical raw and dosage forms based on reaction with ninhydrin is developed, optimized and validated. The purple color (Ruhemenn's purple) that resulted from the reaction was stabilized and measured at 560 nm. Beer's law is obeyed in the concentration range of 4-80 µg mL-1 with molar absorptivity of 1.42 × 10(5) L mole-1 cm-1. All variables including the reagent concentration, heating time, reaction temperature, color stability period, and cefaclor/ninhydrin ratio were studied in order to optimize the reaction conditions. No interference was observed from common pharmaceutical adjuvant. The developed method is easy to use, accurate and highly cost-effective for routine studies relative to HPLC and other techniques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work proposes a new simple and fast spectrophotometric method for cephalexin determination in pharmaceutical formulations. The method is based on the charge transfer reaction between cephalexin and quinalizarin in dimethylsulfoxide medium. Several analytical parameters related to the system were optimized and the reaction was characterized in terms of stoichiometry. Also, association constant and apparent molar absorptivity of the product were determined. The method presented a limit of detection of 0.46 mg L-1 and a quantification limit of 1.5 mg L-1. It was successfully applied in the determination of cephalexin in two samples of commercial pharmaceutical formulations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cefdinir has broad spectrum of activity and high prescription rates, hence its counterfeiting seems imminent. We have proposed a simple, fast, selective and non-extractive spectrophotometric method for the content assay of cefdinir in formulations. The method is based on complexation of cefdinir and Fe under reducing condition in a buffered medium (pH 11) to form a magenta colored donor-acceptor complex (λ max = 550 nm; apparent molar absorptivity = 3720 L mol-1 cm-1). No other cephalosporins, penicillins and common excipients interfere under the test conditions. The Beer's law is followed in the concentration range 8-160 µg mL-1.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new simple and sensitive flotation-spectrophotometric method for the determination of cetylpyridinium chloride (CPC) is reported. The method is based on the formation of an ion- associate between CPC and Orange II (OR) which is floated in the interface of aqueous phase and n-hexane by vigorous shaking. The aqueous solution was discarded and the adsorbed ion associate on to the wall of a separating funnel was dissolved in a small volume of methanol solvent and its absorbance was measured at 480 nm. The apparent molar absorptivity (Ε) of the ion associate was determined to be 4.12 x 10(5) L mol-1 cm-1. The calibration graph was linear in the concentration range of 15-800 ng mL-1 of CPC with a correlation coefficient of 0.9988. The limit of detection (LOD) was 10.8 ng mL-1. The relative standard deviation (RSD) for determination of 100 and 800 ng mL-1 of CPC was 3.47 and 2.04% (n=7), respectively. The method was successfully applied to the determination of CPC in a commercial mouth washer product.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A spectrophotometric method based on the formation of ion-pair complex between haloperidol and eriochrome black T (EBT) at pH 1.85 has been described. The formed complex was extracted quantitatively into chloroform and measured at 510 nm. Infra red (IR) studies were performed to confirm the formation of ion-pair complex. Beer's law was obeyed in the concentration range of 2.0-9.0 µg mL-1 with molar absorptivity of 2.67 × 10(4) L mol-1 cm-1. The detection limit was found to be 0.18 µg mL-1. Statistical comparison of the results of the proposed method with those of the reference method shows excellent agreement and indicates no significant difference in accuracy and precision.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, an effective and low-cost method for the determination of sodium or potassium diclofenac is proposed in its pure form and in their pharmaceutical preparations. The method is based on the reaction between diclofenac and tetrachloro-p-benzoquinone (p-chloranil), in methanol medium. This reaction was accelerated by irradiating of reactional mixture with microwave energy (1100 W) during 27 seconds, producing a charge transfer complex with a maximum absorption at 535 nm. The optimal reaction conditions values such as reagent concentration, heating time and stability of the reaction product were determined. Beer's law is obeyed in a concentration range from of 1.25x10-4 to 2.00x10-3 mol l-1 with a correlation coefficient of 0.9993 and molar absorptivity of 0.49 x10³ l mol-1 cm-1. The limit of detection (LOD) was 1.35x10-5 mol l-1 and the limit of quantification (LOQ) was 4.49x10-5 mol l-1. In the presence of the common excipients, such as glucose, lactose, talc, starch, magnesium stearate, sodium sulphite, titanium dioxide, polyethyleneglycol, polyvinylpirrolidone, mannitol and benzilic alcohol no interferences were observed. The analytical results obtained by applying the proposed method compare very favorably with those given by the United States Pharmacopeia standard procedure. Recoveries of diclofenac from various pharmaceutical preparations were within 95.9% to 103.3%, with standard deviations ranging from 0.2% to 1.8%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The possibility of using thiocyanate to determine iron(II) and/or iron(III) in water-acetone mixture has been re-examined as part of a systematic and comparative study involving metallic complexes of pseudohalide ligands. Some parameters that affect the complete oxidation of the ferrous cations, their subsequent complexation and the system stability have been studied to optimize the experimental conditions. Our results show the viability and potentiality of this simply methodology as an alternative analytical procedure to determine iron cations with high sensitivity, precision and accuracy. Studies on the calibration, stability, precision, and effect of various different ions have been carried out by using absorbance values measured at 480 nm. The analytical curve for the total iron determination obeys Beer's law (r = 0.9993), showing a higher sensitivity (molar absorptivity of 2.10x10(4) L cm-1 mol-1) when compared with other traditional systems (ligands) or even with the "similar" azide ion [1.53x10(4) L cm-1 mol-1, for iron-III/azide complexes, in 70% (v/v) tetrahydrofuran/water, at 396 nm]. Under such optimized experimental conditions, it is possible to determine iron in the concentration range from 0.5 to 2 ppm (15-65% T for older equipments, quartz cells of 1.00 cm). Analytical applications have been tested for some different materials (iron ores), also including pharmaceutical products for anemia, and results were compared with atomic absorption determinations. Very good agreement was obtained with these two different techniques, showing the potential of the present experimental conditions for the total iron spectrophotometric determinations (errors < 5%). The possibility of iron speciation was made evident by using another specific and auxiliary method for iron(II) or (III).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Three sensitive spectrophotometric methods are presented for the determination of finasteride in bulk and in tablets. The methods rely on the use of bromate-bromide reagent and three dyes namely, methyl orange, indigocarmine and thymol blue as reagents. They involve the addition of a measured excess of bromate-bromide reagent to finasteride in acid medium, and after the bromination reaction is judged to be complete, the unreacted bromine is determined by reacting with a fixed amount of either methylorange and measuring the absorbance at 520 nm (method A) or indigocarmine and measuring the absorbance at 610 nm (method B) or thymol blue and measuring the absorbance at 550 nm (method C). In all the methods, the amount of insitu generated bromine reacted corresponds to the amount of finasteride. The absorbance measured at the respective wavelength is found increase linearly with the concentration of finasteride. Beer's law is obeyed in the ranges 0.25- 2.0, 0.5-6.0 and 1-12 µg mL-1 for method A, method B and method C, respectively. The calculated molar absorptivity values are 5.7x10(4), 3.12x10(4) and 1.77x10(4) L mol-1 cm-1 respectively, for method A, method B and method C, and the corresponding Sandell sensitivity values are 0.0065, 0.012 and 0.021 µg cm-2. The limits of detection (LOD) and quantification (LOQ) are also reported for all the methods. Accuracy and, intra-day and inter-day precisions of the methods were established according to the current ICH guidelines. The methods were successfully applied to the determination of finasteride in commercially available tablets and the results were found to closely agree with the label claim. The results of the methods were statistically compared with those of a reference method by applying Student's t-test and F-test. The accuracy and reliability of the methods were further confirmed by performing recovery tests via standard addition procedure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two simple sensitive and cost-effective spectrophotometric methods are described for the determination of lansoprazole (LPZ) in bulk drug and in capsules using ceric ammonium sulphate (CAS), iron (II), orthophenanthroline and thiocyanate as reagents. In both methods, an acidic solution of lansoprazole is treated with a measured excess of CAS followed by the determination of unreacted oxidant by two procedures involving different reaction schemes. The first method involves the reduction of residual oxidant by a known amount of iron(II), and the unreacted iron(II) is complexed with orthophenanthroline at a raised pH, and the absorbance of the resulting complex measured at 510 nm (method A). In the second method, the unreacted CAS is reduced by excess of iron (II), and the resulting iron (III) is complexed with thiocyanate in the acid medium and the absorbance of the complex measured at 470 nm (method B). In both methods, the amount CAS reacted corresponds to the amount of LPZ. In method A, the absorbance is found to increase linearly with the concentration of LPZ where as in method B a linear decrease in absorbance occurs. The systems obey Beer's law for 2.5-30 and 2.5-25 µg mL-1 for method A and method B, respectively, and the corresponding molar absorptivity values are 8.1×10³ and 1.5×10(4) L mol-1cm-1 . The methods were successfully applied to the determination of LPZ in capsules and the results tallied well with the label claim. No interference was observed from the concomitant substances normally added to capsules.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A sensitive and alternative method for the spectrophotometric determination of chromium(III) based on the formation of chromium(III)/azide complexes was established by investigating a new band in the ultraviolet region. The best experimental conditions for the analytical determination of this metallic ion were: ligand and perchloric acid analytical concentration = 493 and 12.0 mmol L-1, respectively; aqueous medium; T = 25.0 ºC; contact time = 1 hour. The maximum molar absorptivity coefficient occurred at 287 nm (average 1.481 ± 0.008 ´ 10(4) L mol-1 cm-1), leading to the determination of metal ion concentrations one hundred times lower than the ones formerly determined in the visible region. The system obeys Beer's Law and is suitable for chromium determination in the 0.702-2.81 mg L-1 concentration range (15-65% T, 1.00 cm-width quartz cells). Analytical applications of the current method were tested with a nutritional supplement containing chromium. Results were compared with those obtained with atomic absorption spectrometry.