943 resultados para Absolute quantification


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The mass spectrometry technique of multiple reaction monitoring (MRM) was used to quantify and compare the expression level of lactoferrin in tear films among control, prostate cancer (CaP), and benign prostate hyperplasia (BPH) groups. Tear samples from 14 men with CaP, 15 men with BPH, and 14 controls were analyzed in the study. Collected tears (2 μl) of each sample were digested with trypsin overnight at 37 °C without any pretreatment, and tear lactoferrin was quantified using a lactoferrin-specific peptide, VPSHAVVAR, both using natural/light and isotopic-labeled/heavy peptides with MRM. The average tear lactoferrin concentration was 1.01 ± 0.07 μg/μl in control samples, 0.96 ± 0.07 μg/μl in the BPH group, and 0.98 ± 0.07 μg/μl in the CaP group. Our study is the first to quantify tear proteins using a total of 43 individual (non-pooled) tear samples and showed that direct digestion of tear samples is suitable for MRM studies. The calculated average lactoferrin concentration in the control group matched that in the published range of human tear lactoferrin concentration measured by enzyme-linked immunosorbent assay (ELISA). Moreover, the lactoferrin was stably expressed across all of the samples, with no significant differences being observed among the control, BPH, and CaP groups.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The further development of Taqman quantitative real-time PCR (qPCR) assays for the absolute quantitation of Marek's disease virus serotype 1 (MDV1) and Herpesvirus of turkeys (HVT) viruses is described and the sensitivity and reproducibility of each assay reported. Using plasmid DNA copies, the lower limit of detection was determined to be 5 copies for the MDV1 assay and 75 copies for the HVT assay. Both assays were found to be highly reproducible for Ct values and calculated copy numbers with mean intra- and inter-assay coefficients of variation being less than 5% for Ct and 20% for calculated copy number. The genome copy number of MDV1 and HVT viruses was quantified in PBL and feather tips from experimentally infected chickens, and field poultry dust samples. Parallelism was demonstrated between the plasmid-based standard curves, and standard curves derived from infected spleen material containing both viral and host DNA, allowing the latter to be used for absolute quantification. These methods should prove useful for the reliable differentiation and absolute quantitation of MDV1 and HVT viruses in a wide range of samples.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

L’étude du cerveau humain est un domaine en plein essor et les techniques non-invasives de l’étudier sont très prometteuses. Afin de l’étudier de manière non-invasive, notre laboratoire utilise principalement l’imagerie par résonance magnétique fonctionnelle (IRMf) et l’imagerie optique diffuse (IOD) continue pour mesurer et localiser l’activité cérébrale induite par une tâche visuelle, cognitive ou motrice. Le signal de ces deux techniques repose, entre autres, sur les concentrations d’hémoglobine cérébrale à cause du couplage qui existe entre l’activité neuronale et le flux sanguin local dans le cerveau. Pour être en mesure de comparer les deux signaux (et éventuellement calibrer le signal d’IRMf par l’IOD), où chaque signal est relatif à son propre niveau de base physiologique inconnu, une nouvelle technique ayant la capacité de mesurer le niveau de base physiologique est nécessaire. Cette nouvelle technique est l’IOD résolue temporellement qui permet d’estimer les concentrations d’hémoglobine cérébrale. Ce nouveau système permet donc de quantifier le niveau de base physiologique en termes de concentrations d’hémoglobine cérébrale absolue. L’objectif général de ma maîtrise était de développer un tel système afin de l’utiliser dans une large étude portant sur la condition cardiovasculaire, le vieillissement, la neuroimagerie ainsi que les performances cognitives. Il a fallu tout d’abord construire le système, le caractériser puis valider les résultats avant de pouvoir l’utiliser sur les sujets de recherche. La validation s’est premièrement réalisée sur des fantômes homogènes ainsi qu’hétérogènes (deux couches) qui ont été développés. La validation des concentrations d’hémoglobine cérébrale a été réalisée via une tâche cognitive et appuyée par les tests sanguins des sujets de recherche. Finalement, on présente les résultats obtenus dans une large étude employant le système d’IOD résolue temporellement en se concentrant sur les différences reliées au vieillissement.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Plusieurs tests médicaux, comme celui du dépistage du cancer du sein, se basent sur l’observation de section tissulaire sous un microscope. Ces tests se basent sur l’interprétation d’un spécialiste et les résultats peuvent varier d’un expert à un autre dû la subjectivité des observations. L’utilisation d’une technique analytique offrant une quantification et une identification de cibles moléculaires dans une section tissulaire permettrait aux experts de produire des diagnostics plus objectifs et diminuerait possiblement le nombre de faux diagnostics. Les travaux présentés dans ce mémoire portent sur le développement d’une technique SPRi-MALDI-IMS permettant l’imagerie en deux dimensions de protéines contenues dans une section tissulaire. La MALDI-IMS est la technique de choix pour l’imagerie de biomolécules dans les sections tissulaires. Par contre, elle ne parvient pas à elle seule à quantifier de façon absolue le matériel adsorbé à la surface. Donc, le couplage de la MALDI-IMS avec la SPRi permet la quantification absolue de protéines en deux dimensions et crée une technique répondant aux besoins des experts médicaux. Pour ce faire, nous avons étudié, l’effet de la chimie de surface sur la nature et la quantité de matériel adsorbé à la surface du capteur. De plus, la cinétique de transfert des protéines du tissu vers le capteur a dû être optimisée afin de produire des empreintes correspondant au tissu d’origine, afin d’atteindre la gamme dynamique des instruments SPRi et MALDI-IMS. La technique résultante de ces optimisations permet d’obtenir les premières images quantitatives et qualitatives de protéines en deux dimensions d’une seule section tissulaire.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This thesis focused on the polymer’s influence on the interaction of polymeric NPs with epithelial cells. Furthermore, the measurement of single submicron nanoparticles in a commercially available flow cytometer was established, to provide a new method in the toolbox for nanoparticle-cell studies. This gave way to develop a routine for the absolute quantification of intracellular NPs via flow cytometry. rnThe cellular uptake of poly(methyl methacrylate) (PMMA), polystyrene (PS) and poly(L-lactide) (PLLA) nanoparticles was investigated via flow cytometry. PLLA-NPs were internalized the most efficiently. But upon co-incubation of PS and PLLA particles with cells, the two particles mutually influenced their uptake, slightly shifting the relative uptake efficiencies. This phenomenon should be based on specific properties of the different polymer materials. The findings indicated a competition (which is strongly influenced by properties of the respective polymeric material) for the uptake into the cells, allegedly due to competition for specific coatings with serum components that enhances the NPs’ cellular uptake. The fluorescence of single 150 nm particles was determined with a benchtop cytometer, breaching the machine’s detection limit but yielding precise NP fluorescence standardization factors. Up to now, these standardization factors are mostly determined by spectroscopic analysis of the particles’ dye content. Finally a flow cytometric routine for absolute particle counting in cells was devised. This quantitation revealed a low uptake efficiency for un-functionalized PMMA NPs of less than 150 NPs (approx. 0,001 % of added) per cell.rn

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The secondary metabolites in the roots, leaves and flowers of the common dandelion (Taraxacum officinale agg.) have been studied in detail. However, little is known about the specific constituents of the plant’s highly specialized laticifer cells. Using a combination of liquid and gas chromatography, mass spectrometry and nuclear magnetic resonance spectrometry, we identified and quantified the major secondary metabolites in the latex of different organs across different growth stages in three genotypes, and tested the activity of the metabolites against the generalist root herbivore Diabrotica balteata. We found that common dandelion latex is dominated by three classes of secondary metabolites: phenolic inositol esters (PIEs), triterpene acetates (TritAc) and the sesquiterpene lactone taraxinic acid β-d-glucopyranosyl ester (TA-G). Purification and absolute quantification revealed concentrations in the upper mg g−1 range for all compound classes with up to 6% PIEs, 5% TritAc and 7% TA-G per gram latex fresh weight. Contrary to typical secondary metabolite patterns, concentrations of all three classes increased with plant age. The highest concentrations were measured in the main root. PIE profiles differed both quantitatively and qualitatively between plant genotypes, whereas TritAc and TA-G differed only quantitatively. Metabolite concentrations were positively correlated within and between the different compound classes, indicating tight biosynthetic co-regulation. Latex metabolite extracts strongly repelled D. balteata larvae, suggesting that the latex constituents are biologically active.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Adenosine is an important cardioprotective agent that works via several adenosine receptor (ADOR) subtypes to regulate cardiovascular activity. It is well established that functional responses to adenosine decline with age. What is unclear, though, is whether these changes occur at the receptor, second messenger or translational level. In this study we determined the effect of age on cardiac adenosine receptor expression using the housekeeping gene 18S rRNA versus the adenosine A2B receptor gene as internal controls. Absolute quantification showed that no age-related changes occurred in the expression of 18S rRNA or adenosine A2B receptor internal control genes. Subsequently, relative analysis of the adenosine receptor subtypes using 18S rRNA found a significant age-related reduction in the expression of the adenosine A1 receptor (5.5-fold), with no changes in the expression of the adenosine A2A, A2B and A3 receptors. When using the expression of the adenosine A2B receptor as the internal control gene, a significant down regulation of both the adenosine A1 (5.4-fold) and A2A (2.2-fold) receptors with no change in the expression of adenosine A3 receptor was found. Therefore, the high level of expression of the 18S rRNA housekeeping gene was found to mask a significant change in expression of the adenosine A2A receptor with age. Ultimately, these findings show an age-related reduction in adenosine A1 and A2A receptor expression in rat heart.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

There is an increasing need in biology and clinical medicine to robustly and reliably measure tens-to-hundreds of peptides and proteins in clinical and biological samples with high sensitivity, specificity, reproducibility and repeatability. Previously, we demonstrated that LC-MRM-MS with isotope dilution has suitable performance for quantitative measurements of small numbers of relatively abundant proteins in human plasma, and that the resulting assays can be transferred across laboratories while maintaining high reproducibility and quantitative precision. Here we significantly extend that earlier work, demonstrating that 11 laboratories using 14 LC-MS systems can develop, determine analytical figures of merit, and apply highly multiplexed MRM-MS assays targeting 125 peptides derived from 27 cancer-relevant proteins and 7 control proteins to precisely and reproducibly measure the analytes in human plasma. To ensure consistent generation of high quality data we incorporated a system suitability protocol (SSP) into our experimental design. The SSP enabled real-time monitoring of LC-MRM-MS performance during assay development and implementation, facilitating early detection and correction of chromatographic and instrumental problems. Low to sub-nanogram/mL sensitivity for proteins in plasma was achieved by one-step immunoaffinity depletion of 14 abundant plasma proteins prior to analysis. Median intra- and inter-laboratory reproducibility was <20%, sufficient for most biological studies and candidate protein biomarker verification. Digestion recovery of peptides was assessed and quantitative accuracy improved using heavy isotope labeled versions of the proteins as internal standards. Using the highly multiplexed assay, participating laboratories were able to precisely and reproducibly determine the levels of a series of analytes in blinded samples used to simulate an inter-laboratory clinical study of patient samples. Our study further establishes that LC-MRM-MS using stable isotope dilution, with appropriate attention to analytical validation and appropriate quality c`ontrol measures, enables sensitive, specific, reproducible and quantitative measurements of proteins and peptides in complex biological matrices such as plasma.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Motivated by needs in molecular diagnostics and advances in microfabrication, researchers started to seek help from microfluidic technology, as it provides approaches to achieve high throughput, high sensitivity, and high resolution. One strategy applied in microfluidics to fulfill such requirements is to convert continuous analog signal into digitalized signal. One most commonly used example for this conversion is digital PCR, where by counting the number of reacted compartments (triggered by the presence of the target entity) out of the total number of compartments, one could use Poisson statistics to calculate the amount of input target.

However, there are still problems to be solved and assumptions to be validated before the technology is widely employed. In this dissertation, the digital quantification strategy has been examined from two angles: efficiency and robustness. The former is a critical factor for ensuring the accuracy of absolute quantification methods, and the latter is the premise for such technology to be practically implemented in diagnosis beyond the laboratory. The two angles are further framed into a “fate” and “rate” determination scheme, where the influence of different parameters is attributed to fate determination step or rate determination step. In this discussion, microfluidic platforms have been used to understand reaction mechanism at single molecule level. Although the discussion raises more challenges for digital assay development, it brings the problem to the attention of the scientific community for the first time.

This dissertation also contributes towards developing POC test in limited resource settings. On one hand, it adds ease of access to the tests by incorporating massively producible, low cost plastic material and by integrating new features that allow instant result acquisition and result feedback. On the other hand, it explores new isothermal chemistry and new strategies to address important global health concerns such as cyctatin C quantification, HIV/HCV detection and treatment monitoring as well as HCV genotyping.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Os vírus linfotrópicos de células T humanas, quando integrados ao genoma da célula hospedeira, provírus, têm como marcador de replicação seu DNA proviral. A carga proviral parece ser um importante fator no desenvolvimento de patologias associadas a estes retrovírus. Neste estudo foi desenvolvida uma metodologia para quantificação absoluta da carga proviral dos HTLV-1 e HTLV-2 através da PCR em tempo real. Cinqüenta e três amostras de doadores de sangue com teste de ELISA reagente foram submetidas à metodologia, que utilizou o sistema TaqMan® para três seqüências alvo: HTLV-1, HTLV-2 e albumina. A quantificação proviral absoluta foi determinada através da proporção relativa entre o genoma do HTLV e o genoma da célula hospedeira, levando em consideração o número de leucócitos. O método apresentado é sensível (215 cópias/mL), prático e simples para quantificação proviral, além de eficiente e adequado para confirmação e discriminação da infecção pelos tipos virais.