150 resultados para AWÁS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Wandering represents a major problem in the management of patients with Alzheimer’s disease (AD). In this study we examined the utility of the Algase Wandering Scale (AWS), a newly developed psychometric instrument that asks caregivers to assess the likelihood of wandering behavior. Methods The AWS was administered to the caregivers of 40 AD patients and total and subscale scores were examined in relation to measures of mental and functional status, depressive symptoms and medication usage. Results AWS scores were comparable, though slightly lower, than those normative values previously published. Higher scores were associated with more severe dementia. The Negative Outcome subscale showed a significant increase in reported falls or injuries in association with anti-depressant use. Conclusions These data provide some construct validation for the AWS as a potentially useful scale to assess wandering behaviors in AD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Axillary web syndrome (AWS) can result in early post-operative and long-term difficulties following lymphadenectomy for cancer and should be recognised by clinicians. This systematic review was conducted to synthesise information on AWS clinical presentation and diagnosis, frequency, natural progression, grading, pathoaetiology, risk factors, symptoms, interventions and outcomes. Methods Electronic searches were conducted using Cochrane, Pubmed, MEDLINE, CINAHL, EMBASE, AMED, PEDro and Google Scholar until June 2013. The methodological quality of included studies was determined using the Downs and Black checklist. Narrative synthesis of results was undertaken. Results Thirty-seven studies with methodological quality scores ranging from 11 to 26 on a 28-point scale were included. AWS diagnosis relies on inspection and palpation; grading has not been validated. AWS frequency was reported in up to 85.4 % of patients. Biopsies identified venous and lymphatic pathoaetiology with five studies suggesting lymphatic involvement. Twenty-one studies reported AWS occurrence within eight post-operative weeks, but late occurrence of greater than 3 months is possible. Pain was commonly reported with shoulder abduction more restricted than flexion. AWS symptoms usually resolve within 3 months but may persist. Risk factors may include extensiveness of surgery, younger age, lower body mass index, ethnicity and healing complications. Low-quality studies suggest that conservative approaches including analgesics, non-steroidal anti-inflammatory drugs and/or physiotherapy may be safe and effective for early symptom reduction. Conclusions AWS appears common. Current evidence for the treatment of AWS is insufficient to provide clear guidance for clinical practice. Implications for Cancer Survivors Cancer survivors should be informed about AWS. Further investigation is needed into pathoaetiology, long-term outcomes and to determine effective treatment using standardised outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We use an automatic weather station and surface mass balance dataset spanning four melt seasons collected on Hurd Peninsula Glaciers, South Shetland Islands, to investigate the point surface energy balance, to determine the absolute and relative contribution of the various energy fluxes acting on the glacier surface and to estimate the sensitivity of melt to ambient temperature changes. Long-wave incoming radiation is the main energy source for melt, while short-wave radiation is the most important flux controlling the variation of both seasonal and daily mean surface energy balance. Short-wave and long-wave radiation fluxes do, in general, balance each other, resulting in a high correspondence between daily mean net radiation flux and available melt energy flux. We calibrate a distributed melt model driven by air temperature and an expression for the incoming short-wave radiation. The model is calibrated with the data from one of the melt seasons and validated with the data of the three remaining seasons. The model results deviate at most 140 mm w.e. from the corresponding observations using the glaciological method. The model is very sensitive to changes in ambient temperature: a 0.5 ◦ C increase results in 56 % higher melt rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

"January 1991."

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper suggests modifications in coating of electrodes providing an alternative for execution of welding with low hydrogen electrode AWS E7018 without having to dry it, reducing thus the cost and time of manufacturing of high resistance welds. The welds in this research were developed with basic coated electrodes (hygroscopic) – SMAW process – externally painted with aluminum spray paint for high temperatures or wrapped with thin plastic films (PVC) and aluminum foil films used commonly for food protection. The basic premise is that establishing a barrier between the atmosphere and the electrode coating could reduce the effects of high hygroscopicity presented by coatings of low hydrogen, minimizing this way the main source of supply of hydrogen to the fusion pool during welding. It is also expected that the addition of new materials from the electrode coating to the fusion pool would induce metallurgical changes in the deposited metal and, as a consequence, modifications in its mechanical properties. This research dealt with measuring the dissolved hydrogen in the deposited metal after welding with modified electrodes, evaluating the influence of these changes in the produced microstructures and in the mechanical properties of the resulting weld, and comparing the obtained results with the standard welding procedures and with the recently developed waterproof electrodes. The results obtained in most samples welded with modified electrodes showed increased mechanical resistance and increased tenacity due to the increased percentage of acicular ferrite in metal deposited without significant elevation of hardness, when compared with the traditional welding with AWS E7018 electrode and with ELBRÁS BRH4R waterproof electrode. The diffusing hydrogen measured in the modified electrodes was kept inside the parameters defined by international codes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper suggests modifications in coating of electrodes providing an alternative for execution of welding with low hydrogen electrode AWS E7018 without having to dry it, reducing thus the cost and time of manufacturing of high resistance welds. The welds in this research were developed with basic coated electrodes (hygroscopic) – SMAW process – externally painted with aluminum spray paint for high temperatures or wrapped with thin plastic films (PVC) and aluminum foil films used commonly for food protection. The basic premise is that establishing a barrier between the atmosphere and the electrode coating could reduce the effects of high hygroscopicity presented by coatings of low hydrogen, minimizing this way the main source of supply of hydrogen to the fusion pool during welding. It is also expected that the addition of new materials from the electrode coating to the fusion pool would induce metallurgical changes in the deposited metal and, as a consequence, modifications in its mechanical properties. This research dealt with measuring the dissolved hydrogen in the deposited metal after welding with modified electrodes, evaluating the influence of these changes in the produced microstructures and in the mechanical properties of the resulting weld, and comparing the obtained results with the standard welding procedures and with the recently developed waterproof electrodes. The results obtained in most samples welded with modified electrodes showed increased mechanical resistance and increased tenacity due to the increased percentage of acicular ferrite in metal deposited without significant elevation of hardness, when compared with the traditional welding with AWS E7018 electrode and with ELBRÁS BRH4R waterproof electrode. The diffusing hydrogen measured in the modified electrodes was kept inside the parameters defined by international codes.