453 resultados para APPLIANCE
Resumo:
Bonded maxillary expansion appliances have been suggested to control increases in the vertical dimension of the face after rapid maxillary expansion (RME). However, there is still no consensus in the literature about its real skeletal effects. The purpose of this prospective study was to evaluate, longitudinally, the vertical and sagittal cephalometric alterations after RME performed with bonded maxillary expansion appliance. The sample consisted of 26 children, with a mean age of 8.7 years (range: 6.9-10.9 years), with posterior skeletal crossbite and indication for RME. After maxillary expansion, the bonded appliance was used as a fixed retention for 3.4 months, being replaced by a removable retention subsequently. The cephalometric study was performed onto lateral radiographs, taken before treatment was started, and again 6.3 months after removing the bonded appliance. Intra-group comparison was made using paired t test. The results showed that there were no significant sagittal skeletal changes at the end of treatment. There was a small vertical skeletal increase in five of the eleven evaluated cephalometric measures. The maxilla displaced downward, but it did not modify the facial growth patterns or the direction of the mandible growth. Under the specific conditions of this research, it may be concluded that RME with acrylic bonded maxillary expansion appliance did promote signifciant vertical or sagittal cephalometric alterations. The vertical changes found with the use of the bonded appliance were small and probably transitory, similar to those occurred with the use of banded expansion appliances.
Resumo:
Objective. The objective of this study was to evaluate, using computed tomography, correlations between Hyrax appliance opening and post-SARPE skeletal changes. Study design. Fifteen patients underwent SARPE according to a specific protocol and were followed. Linear and angular measurements of the anterior, intermediate, and posterior portions of the maxilla were evaluated. The correlation between maxillary expansion and appliance opening was investigated. Results. Significant overall expansion was observed. In the anterior and intermediate portions of the maxilla, the increase in maxillary width was greater than that observed in the posterior portion. The degree of appliance opening was significantly greater than that of the skeletal expansion. Also, no linear correlation between appliance opening and regional maxillary expansion was established. Conclusion. The transverse expansion of the maxilla was less than uniform. The lack of linear correlation between appliance opening and skeletal expansion is attributable to multiple factors, including those related to the device, the surgical technique, and the craniofacial deformity itself. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008; 106: 812-819)
Resumo:
Functional orthopedic therapy corrects growth discrepancies between the maxilla and mandible, possibly through postural changes in the musculature and modulation of the mandibular condylar cartilage growth. Using Wistar rats, we tested the hypothesis that chondrocytes respond to forces generated by a mandibular propulsor appliance by changes in gene expression, and that integrins are important mediators in this response. Immunohistochemical analyses demonstrated that the use of the appliance for different periods of time modulated the expression of fibronectin, alpha 5 and alpha v integrin subunits, as well as cell proliferation in the cartilage. In vitro, cyclic distension of condylar cartilage-derived cells increased fibronectin mRNA, as well as Insulinlike Growth Factor-I and II mRNA and cell proliferation. A peptide containing the Arginine-Glycine-Asparagine sequence (RGD), the main cell-binding sequence in fibronectin, blocked almost all these effects, confirming that force itself modulates the growth of the rat condylar cartilage, and that RGD-binding integrins participate in mechanotransduction.
Resumo:
Introduction: In this retrospective study, we compared the cephalometric effects, the dental-arch changes, and the efficiency of Class II treatment with the pendulum appliance, cervical headgear, or extraction of 2 maxillary premolars, all associated with fixed appliance therapy. Methods: The sample of 82 patients with Class II malocclusion was divided into 3 groups: group 1 patients (n = 22; treatment time, 3.8 years) were treated with the pendulum appliance and fixed orthodontic appliances. Group 2 patients (n = 30; treatment time, 3.2 years) were treated with cervical headgear followed by fixed appliances; group 3 patients (n = 30; treatment time, 2.1 years) were treated with 2 maxillary premolar extractions and fixed appliances. The average starting ages of the groups ranged from 13.2 to 13.8 years. Data were obtained from serial cephalometric measurements and dental casts. The dental casts were analyzed with the treatment priority index. The treatment efficiency index was also used. Results: The 3 treatment protocols produced similar cephalometric effects, especially skeletally. Comparisons among the 2 distalizing appliances (pendulum and cervical headgear) and extraction of 2 maxillary premolars for Class II treatment showed changes primarily in the maxillary dentoalveolar component and dental relationships. The facial profile was similar after treatment, except for slightly more retrusion of the upper lip in the extraction patients. The treatment priority index demonstrated that occlusal outcomes also were similar among the groups. The treatment efficiency index had higher values for the extraction group. Conclusions: The effects of treatment with the pendulum appliance or cervical headgear and extraction of 2 maxillary premolars associated with fixed appliances were similar from both occlusal and cephalometric standpoints. Class II treatment with extraction of maxillary teeth was more efficient because of the shorter treatment time. Differences in maxillary incisor retraction should be noted, but these differences might have been due to greater maxillary dentoalveolar protrusion in the extraction group before treatment. (Am J Orthod Dentofacial Orthop 2009;136:833-42)
Resumo:
The objective of this study was to compare, on study models and initial cephalograms, the efficiency of Class II malocclusion treatment with the pendulum appliance, and with two maxillary premolar extraction protocol. The sample consisted of 48 treated Class II malocclusion patients: group 1 comprised 22 patients (7 males, 15 females) treated with the pendulum appliance, with an initial mean age of 14.44 years and group 2, 26 patients (14 males, 12 females) treated with two maxillary premolar extractions at an initial mean age of 13.66 years. To compare the efficiency of each treatment protocol, the occlusal outcomes were evaluated on dental casts using the Peer Assessment Rating (PAR) Index and the treatment time (TT) of each group was calculated on clinical charts. The degree of treatment efficiency was calculated as the ratio between the percentage of occlusal improvement, evaluated through the PAR index, and TT. Statistical analysis was undertaken by means of t-tests. The findings demonstrated that the two maxillary premolar extraction protocol provided the occlusal outcomes in a shorter time (group 1: 45.7 months, group 2: 23.01 months) and, therefore, demonstrated greater treatment efficiency than the pendulum appliance.
Resumo:
Proyecto realizado para la empresa de reparación de aparatos eléctricos Domestic Appliance con el que se se pretende facilitar y mejorar el proceso de gestión de todas las reparaciones que se realizan mediante una aplicación web. A nivel de Pyme, se trata de un sistema básico de CRM (Customer Relationship Management) y de un gestor de incidencias con el que los empleados de la empresa Domestic Appliance podrán mantener un mejor seguimiento de todos los casos abiertos, ver estadísticas y obtener información de todos los clientes. El sistema se completa con la gestión de un correo interno dónde los usuarios se podrán enviar información confidencial entre ellos, actuando como un correo interno.
Resumo:
El proyecto consiste en el desarrollo de una distribución Live, que contiene el software colaborativo Teambox. Esta distribución puede ser instalada en un equipo físico y ser puesta en produccion.
Resumo:
The aim of this investigation was to analyze the dental occlusion in the deciduous dentition, and the effects of orthodontic treatment carried out in the early mixed dentition with the eruption guidance appliance. The deciduous occlusion and craniofacial morphology of 486 children (244 girls and 242 boys) were investigated at the onset of the mixed dentition period (mean age 5.1 years, range 4.0-7.8 years). Treatment in the treatment group and follow-up in the control group were started when the first deciduous incisor was exfoliated (T1) and ended when all permanent incisors and first molars were fully erupted (T2). The mean age of the children was 5.1 years (SD 0.5) at T1 and 8.4 years (SD 0.5) at T2. Treatment was carried out with the eruption guidance appliance. Occlusal changes that took place in 167 children were compared with those of 104 untreated control children. Pre- and post-treatment cephalometric radiographs were taken, and the craniofacial morphology of 115 consecutively treated children was compared with that of 104 control children. The prevalence of malocclusion in the deciduous dentition was 68% or 93% depending on how the cut-off value between the acceptable and non-acceptable occlusal characteristic was defined. The early dentofacial features of children with distal occlusion, large overjet and deepbite differed from those with normal occlusion. However, the skeletal pattern of these three malocclusions showed considerable similarity each being characterized by a retrusive mandible, small maxillo-mandibular difference, convex profile, retrusive lower incisors, and large interincisal angle. In the treatment group, overjet and overbite decreased significantly from T1 to T2. Following treatment, a tooth-to-tooth contact was found in 99% of the treated children but only in 24% of the controls. A Class I molar relationship was observed in 90% of the children in the treatment group, and in 48% in the control group. Good alignment of the incisors was observed in 98% of the treated children, whereas upper crowding was found in 32% and lower crowding in 47% of the controls. A significant difference between the groups was found in the mandibular length, midfacial length and maxillo-mandibular differential. The occlusal correction, brought about by the eruption guidance appliance, was achieved mainly through changes in the dentoalveolar region of the mandible. In addition, the appliance seemed to enhance the growth of the mandible. Treatment in the early mixed dentition using the eruption guidance appliance is an effective method to normalize occlusion and reduce further need of orthodontic treatment. Only few spontaneous corrective changes can be expected without active intervention.
Resumo:
The aim of this thesis was to evaluate the short- and long-term effectiveness of a prefabricated occlusal appliance (R) on patients with myofascial pain and headache by comparing it with the treatment of the stabilization appliance (S). Another aim was to evaluate the effect of appliance treatment on stress-related salivary parameters like cortisol and IgA, as well as on flow rate values in these patients. Sixty-five patients diagnosed with myofascial temporomandibular disorder (TMD) pain, of whom 94% suffered concomitantly from headache, at two centres for Stomatognathic Physiology, one in Sweden and one in Finland, were included in this randomized controlled trial using Research Diagnostic Criteria for TMD (RDC/TMD), with history questionnaires and clinical examinations performed at baseline and at 6- and 10-weeks, and 6- and 12-month follow-ups. Patients were randomly assigned either to the R or the S group. Treatment outcome was measured according to IMMPACT (Initiative on Methods, Measurements, and Pain Assessment in Clinical Trials), i.e. four chronic pain outcome domains: pain intensity, overall improvement, physical and emotional functioning. Changes in frequency and intensity of headache were recorded. Thirty-nine patients participated in the saliva study. Salivary analyses were performed at 6 and 10 weeks. The results revealed no differences between groups at baseline. At all follow-ups, all four outcome measures, as well as frequency and intensity of headache, showed statistically significant within-group improvement compared to baseline, without significant differences between groups. No treatment-induced changes in saliva parameters could be registered. In conclusion, the effectiveness of the prefabricated appliance seemed to be similar to that of the stabilization appliance in alleviating myofascial pain, and frequency and intensity of headache, in the short as well as the long term. However, no changes in salivary parameters were observed during treatment.
Resumo:
In this bachelor’s thesis are examined the benefits of current distortion detection device application in customer premises low voltage networks. The purpose of this study was to find out if there are benefits for measuring current distortion in low-voltage residential networks. Concluding into who can benefit from measuring the power quality. The research focuses on benefits based on the standardization in Europe and United States of America. In this research, were also given examples of appliances in which current distortion detection device could be used. Along with possible illustration of user interface for the device. The research was conducted as an analysis of the benefits of current distortion detection device in residential low voltage networks. The research was based on literature review. The study was divided to three sections. The first explain the reasons for benefitting from usage of the device and the second portrays the low-cost device, which could detect one-phase current distortion, in theory. The last section discuss of the benefits of usage of current distortion detection device while focusing on the beneficiaries. Based on the result of this research, there are benefits from usage to the current distortion detection device. The main benefitting party of the current distortion detection device was found to be manufactures, as they are held responsible of limiting the current distortion on behalf of consumers. Manufactures could adjust equipment to respond better to the distortion by having access to on-going current distortion in network. The other benefitting party are system operators, who would better locate distortion issues in low-voltage residential network to start prevention of long-term problems caused by current distortion early on.
Resumo:
The development of an Artificial Neural Network model of UK domestic appliance energy consumption is presented. The model uses diary-style appliance use data and a survey questionnaire collected from 51 households during the summer of 2010. It also incorporates measured energy data and is sensitive to socioeconomic, physical dwelling and temperature variables. A prototype model is constructed in MATLAB using a two layer feed forward network with backpropagation training and has a12:10:24architecture.Model outputs include appliance load profiles which can be applied to the fields of energy planning (micro renewables and smart grids), building simulation tools and energy policy.
Resumo:
The development of a combined engineering and statistical Artificial Neural Network model of UK domestic appliance load profiles is presented. The model uses diary-style appliance use data and a survey questionnaire collected from 51 suburban households and 46 rural households during the summer of 2010 and2011 respectively. It also incorporates measured energy data and is sensitive to socioeconomic, physical dwelling and temperature variables. A prototype model is constructed in MATLAB using a two layer feed forward network with back propagation training which has a 12:10:24 architecture. Model outputs include appliance load profiles which can be applied to the fields of energy planning (microrenewables and smart grids), building simulation tools and energy policy.
Resumo:
One in four people will experience a mental health problem in any given year. Of those, the vast majority will not receive any psychological or pharmacological help. Even when psychological help is received, it frequently lacks a strong scientific basis. This article describes the extent of the problem in the dissemination and implementation of evidence-based psychological therapies and examines some of the solutions proposed.
Resumo:
Introduction: Orthodontic tooth movement uses mechanical forces that result in inflammation in the first days. Myeloperoxidase (MPO) is an enzyme found in polymorphonuclear neutrophil (PMN) granules, and it is used to estimate the number of PMN granules in tissues. So far, MPO has not been used to study the inflammatory alterations after the application of orthodontic tooth movement forces. The aim of this study was to determine MPO activity in the gingival crevicular fluid (GCF) and saliva (whole stimulated saliva) of orthodontic patients at different time points after fixed appliance activation. Methods: MPO was determined in the GCF and collected by means of periopaper from the saliva of 14 patients with orthodontic fixed appliances. GCF and saliva samples were collected at baseline, 2 hours, and 7 and 14 days after application of the orthodontic force. Results: Mean MPO activity was increased in both the GCF and saliva of orthodontic patients at 2 hours after appliance activation (P<0.02 for all comparisons). At 2 hours, PMN infiltration into the periodontal ligament from the orthodontic force probably results in the increased MPO level observed at this time point. Conclusions: MPO might be a good marker to assess inflammation in orthodontic movement; it deserves further studies in orthodontic therapy. (Am J Orthod Dentofacial Orthop 2010;138:613-6)
Resumo:
Ingestion of a foreign object, including a dental object, can lead to a trip to the emergency room. This article describes the accidental swallowing of a key that was used to activate a rapid maxillary expander. An orthodontic patient swallowed the key while trying to activate the appliance at home. The object's trajectory was followed on radiographs until it was eliminated. Possible clinical complications, legal implications of this situation, and practices for prevention are described. (Am J Orthod Dentofacial Orthop 2011;140:266-8)