951 resultados para ACID DIGESTION METHOD


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study was conducted to evaluated the site and extent of dry matter (DM), crude protein (CP), methionine (Met), lysine (Lys), and threonine (Thr) digestion of corn and byproducts obtained from corn germ mixed with different amounts of extruded or non-extruded ether extract (EE) in dairy cattle. Treatments consisted in eight types of feed and two processing in a 4 x 2 factorial design. There were four feeds: corn grain cracked (Corn), corn germ meal with 1% EE (CG1), corn germ meal with 7% EE (CG7), and corn germ meal with 10% EE (CG10). The feeds were processed in one of two ways: extruded (Ex) and not extruded. In situ techniques were used to determine DM, CP, Met, Lys, and Thr partial and total tract digestion. A basic diet was compounded of corn germ meal, soybean meal and coastcross hay in a 70: 30 roughage to concentrate ratio. There was no interaction (P>0.05) between feeds and processing method. Extrusion improved (P<0.05) total tract digestibility of corn DM but not CP. Intestinal digestibility was similar (P>0.05) for corn and corn germ meal mixed with 7 and 10% EE, regardless of EE processing method. The CP total tract digestibility of corn germ meal with 1% non-extruded EE was 16.62% higher (P<0.05) than that of the extruded form. The best total CP digestibility was obtained for corn germ meal with 7% EE, independently of the processing method. The effects of EE processing method on partial and total digestibility differed between amino acid. Corn and corn byproduct extrusion may improve dry matter digestibility, but do not necessarily influence crude protein digestion. Ruminal and intestinal digestibility of Met, Lys, and Thr depends on both feed type and processing method. Therefore, amino acid availability should be considered individually.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this work was to evaluate the accuracy of digestion techniques using nitric and perchloric acid at the ratios of 2:1, 3:1, and 4:1 v v-1, in one- or two-step digestion, to estimate chromium contents in cattle feces, using sodium molybdate as a catalyst. Fecal standards containing known chromium contents (0, 2, 4, 6, 8, and 10 g kg-1) were produced from feces of five animals. The chromium content in cattle feces is accurately estimated using digestion techniques based on nitric and perchloric acids, at a 3:1 v v-1 ratio, in one-step digestion, with sodium molybdate as a catalyst.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Native enzymes play a significant role in proteolysis of milk during storage. This is significant for heat resistant native enzymes. Plasmin is one of the most heat resistant enzymes found in milk. It has been reported to survive several heat treatments, causing spoilage during storage. The aim of this study was to assess susceptibility of high temperature heated milk to proteolysis by native enzymes. The trinitrobenzene sulphonic acid (TNBS) method was used for this purpose. Raw milk was heated at 110, 120, 130,142°C for 2 s and 85°C for 15 s and milk processed at low temperature (85°C /15s) was selected to mimic pasteurisation. TNBS method confirmed that raw milk and milk processed at 85°C /15s were the most proteolysed, whereas treatment of milk at high temperatures (110, 120, 130 and 142°C for 2 s) inactivated the native enzymes. It may thus be concluded that high temperature processing positively affects proteolysis by lowering its susceptibility to spoilage during storage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Work performed at the International Minerals and Chemical Corporation under Contract AT(49-1)-545 with the U.S. Atomic Energy Commission.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"Contract No. AT(49-1)-538."

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The accelerated growth of urban regions have produced relevant effects on water resources. Urban regions need an adequate institutional structure that can be able to face environmental demands and the adverse effects of land use on water resources. This study aims at analysing land use effects on heavy metals concentration in sediments and water, as well as making a comparative analysis involving water physical-chemical parameters. Applied methodology included both in loco water parameters measurement and water and bed sediment sampling at 8 sections along the fluvial system. Sample analysis was performed in laboratory in order to measure heavy metal concentrations. It was measured metal concentrations of Al, Cu, Pb, Cd, Fe, Ni and Zn. Once the samples were subjected to acid digestion (method 3050B), concentration values were measured by using atomic absorption spectrometry by flame (ICP-FLAA). The analysis results were compared with normative reference, these standards is intended to assess the risks of toxic substances in sediment and water management programs. The normative reference used in this work were: a) Ontario Ministry of the Environment and Energy (OMEE, 1993) b) Normative Netherlands (VROM, 2000); c) Normative Canadian (CCME, 1999); d) United States Environmental Protection Agency (USEPA, 1977), e) CONAMA Resolution No. 344/2004; f) CONAMA Resolution No. 357/2005. The high concentrations of iron (38,750 mg.g-1), Lead (1100 mg.g-1), Nickel (100 μg.g-1) and zinc (180 μg.g-1) detected sediments confirm the state of degradation of the aquatic system. Iron concentrations (1.08 mg.L-1), Aluminum (0.6 mg.L-1) and phosphorus (0.05 mg.L-1) present in the water are outside the established standards for human consumption

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Determination of chlorine using the molecular absorption of aluminum mono-chloride (AlCl) at the 261.418 nm wavelength was accomplished by high-resolution continuum source molecular absorption spectrometry using a transversely heated graphite tube furnace with an integrated platform. For the analysis. 10 mu L of the sample followed by 10 mu L of a solution containing Al-Ag-Sr modifier, (1 g L-1 each), were directly injected onto the platform. A spectral interference due to the use of Al-Ag-Sr as mixed modifier was easily corrected by the least-squares algorithm present in the spectrometer software. The pyrolysis and vaporization temperatures were 500 degrees C and 2200 degrees C, respectively. To evaluate the feasibility of a simple procedure for the determination of chlorine in food samples present in our daily lives, two different digestion methods were applied, namely (A) an acid digestion method using HNO3 only at room temperature, and (B) a digestion method with Ag, HNO3 and H2O2, where chlorine is precipitated as a low-solubility salt (AgCl), which is then dissolved with ammonia solution. The experimental results obtained with method B were in good agreement with the certified values and demonstrated that the proposed method is more accurate than method A. This is because the formation of silver chloride prevented analyte losses by volatilization. The limit of detection (LOD, 3 sigma/s) for Cl in methods A and B was 18 mu g g(-1) and 9 mu g g(-1), respectively, 1.7 and 3.3 times lower compared to published work using inductively coupled plasma optical emission spectrometry, and absolute LODs were 2.4 and 1.2 ng, respectively. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present investigation is the first part of an initiative to prepare a regional map of the natural abundance of selenium in various areas of Brazil, based on the analysis of bean and soil samples. Continuous-flow hydride generation electrothermal atomic absorption spectrometry (HG-ET AAS) with in situ trapping on an iridium-coated graphite tube has been chosen because of the high sensitivity and relative simplicity. The microwave-assisted acid digestion for bean and soil samples was tested for complete recovery of inorganic and organic selenium compounds (selenomethionine). The reduction of Se(VI) to Se(IV) was optimized in order to guarantee that there is no back-oxidation, which is of importance when digested samples are not analyzed immediately after the reduction step. The limits of detection and quantification of the method were 30 ng L(-1) Se and 101 ng L(-1) Se, respectively, corresponding to about 3 ng g(-1) and 10 ng g(-1), respectively, in the solid samples, considering a typical dilution factor of 100 for the digestion process. The results obtained for two certified food reference materials (CRM), soybean and rice, and for a soil and sediment CRM confirmed the validity of the investigated method. The selenium content found in a number of selected bean samples varied between 5.5 +/- 0.4 ng g(-1) and 1726 +/- 55 ng g(-1), and that in soil samples varied between 113 +/- 6.5 ng g(-1) and 1692 +/- 21 ng g(-1). (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There are currently many devices and techniques to quantify trace elements (TEs) in various matrices, but their efficacy is dependent on the digestion methods (DMs) employed in the opening of such matrices which, although "organic", present inorganic components which are difficult to solubilize. This study was carried out to evaluate the recovery of Fe, Zn, Cr, Ni, Cd and Pb contents in samples of composts and cattle, horse, chicken, quail, and swine manures, as well as in sewage sludges and peat. The DMs employed were acid digestion in microwaves with HNO3 (EPA 3051A); nitric-perchloric digestion with HNO3 + HClO4 in a digestion block (NP); dry ashing in a muffle furnace and solubilization of residual ash in nitric acid (MDA); digestion by using aqua regia solution (HCl:HNO3) in the digestion block (AR); and acid digestion with HCl and HNO3 + H2O2 (EPA 3050). The dry ashing method led to the greatest recovery of Cd in organic residues, but the EPA 3050 protocol can be an alternative method for the same purpose. The dry ashing should not be employed to determine the concentration of Cr, Fe, Ni, Pb and Zn in the residues. Higher Cr and Fe contents are recovered when NP and EPA 3050 are employed in the opening of organic matrices. For most of the residues analyzed, AR is the most effective method for recovering Ni. Microwave-assisted digestion methods (EPA3051 and 3050) led to the highest recovery of Pb. The choice of the DM that provides maximum recovery of Zn depends on the organic residue and trace element analyzed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La cellulose et ses dérivés sont utilisés dans un vaste nombre d’applications incluant le domaine pharmaceutique pour la fabrication de médicaments en tant qu’excipient. Différents dérivés cellulosiques tels que le carboxyméthylcellulose (CMC) et l’hydroxyéthylcellulose (HEC) sont disponibles sur le commerce. Le degré de polymérisation et de modification diffèrent énormément d’un fournisseur à l’autre tout dépendamment de l’origine de la cellulose et de leur procédé de dérivation, leur conférant ainsi différentes propriétés physico-chimiques qui leurs sont propres, telles que la viscosité et la solubilité. Notre intérêt est de développer une méthode analytique permettant de distinguer la différence entre deux sources d’un produit CMC ou HEC. L’objectif spécifique de cette étude de maitrise était l’obtention d’un profil cartographique de ces biopolymères complexes et ce, par le développement d’une méthode de digestion enzymatique donnant les oligosaccharides de plus petites tailles et par la séparation de ces oligosaccharides par les méthodes chromatographiques simples. La digestion fut étudiée avec différents paramètres, tel que le milieu de l’hydrolyse, le pH, la température, le temps de digestion et le ratio substrat/enzyme. Une cellulase de Trichoderma reesei ATCC 26921 fut utilisée pour la digestion partielle de nos échantillons de cellulose. Les oligosaccharides ne possédant pas de groupements chromophores ou fluorophores, ils ne peuvent donc être détectés ni par absorbance UV-Vis, ni par fluorescence. Il a donc été question d’élaborer une méthode de marquage des oligosaccharides avec différents agents, tels que l’acide 8-aminopyrène-1,3,6-trisulfonique (APTS), le 3-acétylamino-6-aminoacridine (AA-Ac) et la phénylhydrazine (PHN). Enfin, l’utilisation de l’électrophorèse capillaire et la chromatographie liquide à haute performance a permis la séparation des produits de digestion enzymatique des dérivés de cellulose. Pour chacune de ces méthodes analytiques, plusieurs paramètres de séparation ont été étudiés.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the comparative efficiency of graphite furnace atomic absorption spectrometry (GFAAS) and hydride generation atomic absorption spectrometry (HGAAS) for trace analysis of arsenic (As) in natural herbal products (NHPs). Method: Arsenic analysis in natural herbal products and standard reference material was conducted using atomic absorption spectrometry (AAS), namely, hydride generation AAS (HGAAS) and graphite furnace (GFAAS). The samples were digested with HNO3–H2O2 in a ratio of 4:1 using microwaveassisted acid digestion. The methods were validated with the aid of the standard reference material 1515 Apple Leaves (SRM) from NIST Results: Mean recovery of three different samples of NHPs, using HGAAS and GFAAS, ranged from 89.3 - 91.4 %, and 91.7 - 93.0 %, respectively. The difference between the two methods was insignificant. A (P= 0.5), B (P=0.4) and C (P=0.88) Relative standard deviation (RSD) RSD, i.e., precision was 2.5 - 6.5 % and 2.3 - 6.7 % using HGAAS and GFAAS techniques, respectively. Recovery of arsenic in SRM was 98 and 102 % by GFAAS and HGAAS, respectively. Conclusion: GFAAS demonstrates acceptable levels of precision and accuracy. Both techniques possess comparable accuracy and repeatability. Thus, the two methods are recommended as an alternative approach for trace analysis of arsenic in natural herbal products.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The performance of laser-induced breakdown spectrometry (LIBS) for the determination of Ba, Cd, Cr and Pb in toys has been evaluated by using a Nd:YAG laser operating at 1064 nm and an Echelle spectrometer with intensified charge-coupled device detector. Samples were purchased in different cities of Sao Paulo State market and analyzed directly without sample preparation. Laser-induced breakdown spectrometry experimental conditions (number of pulses, delay time. integration time gate and pulse energy) were optimized by using a Doehlert design. Laser-induced breakdown spectrometry signals correlated reasonably well with inductively coupled plasma optical emission spectrometry (ICP OES) concentrations after microwave-assisted acid digestion of selected samples. Thermal analysis was used for polymer identification and scanning electron microscopy to Visualize differences in crater geometry of different polymers employed for toy fabrication. Results indicate that laser-induced breakdown spectrometry can be proposed as a rapid screening method for investigation of potentially toxic elements in toys. The unique application of laser-induced breakdown spectrometry for identification of contaminants in successive layers of ink and polymer is also demonstrated. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

O descarte ou reutilização da água produzida da indústria do petróleo é difícil por causa dos impactos ambientais causados devido à presença de alta salinidade e componentes tóxicos, ou pelo risco de obstrução nas colunas de produção devido à formação de incrustações que causam redução na produção de petróleo e enormes perdas no processo de extração. Assim, o conhecimento da composição química da água produzida é muito importante. O método proposto por este trabalho visa a determinação de elementos traço (Co, Cr, Fe, Mn, Ni, Se e V) em amostras de água produzida de petróleo por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES) utilizando a digestão ácida assistida por micro-ondas para o preparo das amostras (15 g de amostra e 2 mL de HNO3 concentrado). A curva analítica construída em HNO3 2% v v-1 foi adotada para o método após verificar que não é necessário o uso de salinidade para equiparação de matriz. Para o elemento Ni, não há necessidade do uso de padrão interno, para os elementos Co, Cr, Fe, Mn e V os melhores resultados foram obtidos usando Sc como padrão interno. Para o elemento Se é recomendado o uso de Y como padrão interno. Os limites de detecção obtidos foram Co 0,67, Cr 1,2, Fe 2,3, Mn 0,49, Ni 1,9, Se 3,7 e V 5,5 μg L-1; e os limites de quantificação foram Co 2,2, Cr 4,0, Fe 7,7, Mn 1,6, Ni 6,5, Se 12,4 e V 18,3 μg L-1. A exatidão do procedimento foi verificada através de testes de recuperação em dois níveis de concentração (40 e 80 μg L-1) e análise dos materiais certificados de referência de água estuarina SLEW-2 e de água do mar NASS-5. Bons valores de recuperação foram obtidos e não houve diferença significativa (95% de confiança) entre os resultados obtidos e os valores certificados dos materiais de referência.