995 resultados para AC current
Resumo:
Grid connected PWM-VSIs are being increasingly used for applications such as Distributed Generation (DG), power quality, UPS etc. Appropriate control strategies for grid synchronisation and line current regulation are required to establish such a grid interconnection and power transfer. Control of three phase VSIs is widely reported in iterature. Conventionally, dq control in Synchronous Reference Frame(SRF) is employed for both PLL and line current control where PI-controllers are used to track the DC references. Single phase systems do not have defined direct (d) and quadrature (q) axis components that are required for SRF transformation. Thus, references are AC in nature and hence usage of PI controllers cannot yield zero steady state errors. Resonant controllers have the ability to track AC references accurately. In this work, a resonant controller based single phase PLL and current control technique are being employed for tracking grid frequency and the AC current reference respectively. A single phase full bridge converter is being operated as a STATCOM for performance evaluation of the control scheme.
Resumo:
This paper reports on a low frequency piezoelectric energy harvester that scavenges energy from a wire carrying an AC current. The harvester is described, fabricated and characterized. The device consists of a silicon cantilever with integrated piezoelectric capacitor and proof-mass that incorporates a permanent magnet. When brought close to an AC current carrying wire, the magnet couples to the AC magnetic field from a wire, causing the cantilever to vibrate and generate power. The measured average power dissipated across an optimal resistive load was 1.5 μW. This was obtained by exciting the device into mechanical resonance using the electro-magnetic field from the 2 A source current. The measurements also reveal that the device has a nonlinear response that is due to a spring hardening mechanism.
Resumo:
The multi-level current reinjection concept described in literature is well-known to produce high quality AC current waveforms in high power and high voltage self-commutating current source converters. This paper proposes a novel reinjection circuitry which is capable of producing a 7-level reinjection current. It is shown that this reinjection current effectively increases the pulse number of the converter to 72. The use of PSCAD/EMTDC simulation validates the functionality of the proposed concept illustrating its effectiveness on both AC and DC sides of the converter.
Resumo:
In order to design a High Temperature Superconducting (HTS) machine that is able to operate safely and reliably, studies on the characterization of Second Generation (2G) HTS tapes are of paramount importance. This paper presents an experimental setup to measure critical current of 2G HTS tapes in high DC magnetic fields (up to 5 Tesla) with an AC current ripple superimposed, as well as various temperatures ranging from 25 K to 77 K. The 2G tape measured is the SGS12050 coated conductor made by SuperPower. The critical current is measured by a flux vector with reference to the widest sample face from 0 to 90 degrees in 10 degree steps. Smaller steps are required close to 0 . A Variable Temperature Insert (VTI) is utilized to control temperature change. © 2010 IEEE.
Resumo:
AC loss can be a significant problem for any applications that utilize or produce an AC current or magnetic field, such as an electric machine. The authors are currently investigating the electromagnetic properties of high temperature superconductors with a particular focus on the AC loss in coils made from YBCO superconductors. In this paper, a 2D finite element model based on the H formulation is introduced. The model is then used to calculate the transport AC loss using both a bulk approximation and modeling the individual turns in a racetrack-shaped coil. The coil model is based on the superconducting stator coils used in the University of Cambridge EPEC Superconductivity Group's superconducting permanent magnet synchronous motor design. The transport AC loss of a stator coil is measured using an electrical method based on inductive compensation using a variable mutual inductance. The simulated results are compared with the experimental results, verifying the validity of the model, and ways to improve the accuracy of the model are discussed. © 2010 IEEE.
Resumo:
A single-phase superconducting fault current limiter (SFCL) using a 0.9 m length of YBCO coated conductor (CC) tape was tested in 220 V-60 Hz line for fault current up to 1 kA, operating in 77 K. In this work are presented the IN experimental curves measured under DC and AC currents for the electrical characterization of the CC tape in order to design a low voltage current limiter. The experimental setup is described and the test results are presented for a unit conducting a steady nominal AC current of 50 A and also during the fault time (I to 5 cycles.) the performance of the CC-based SFCL providing the limiting resistance developed in the whole tape length after few milliseconds of the beginning of the fault was analyzed.
Resumo:
A MEMS, silicon based device with a cantilever oscillationsand an integrated magnet is presented for magnetic to electrical transduction. The cantilever structure can be configured either as an energy harvester to harvest power from an AC power line or as an AC current sensor. The positioning of the transducer with respect to the AC conductor is critical in both scenarios. For the energy scavenger, correct positioning is required to optimize the harvested power. For the current sensor, it is necessary to optimise the sensitivity of the sensor. This paper considers the effect of the relative position of the transducer with respect to the wire on the resulting electromagnetic forces and torques driving the device. It is shown here that the magnetic torque acting on a cantilever beam with an integrated magnet and in the vicinity of an alternating electromagnetic field is a very significant driver of the cantilever oscillations.
Resumo:
Bioelectrical impedance analysis, (BIA), is a method of body composition analysis first investigated in 1962 which has recently received much attention by a number of research groups. The reasons for this recent interest are its advantages, (viz: inexpensive, non-invasive and portable) and also the increasing interest in the diagnostic value of body composition analysis. The concept utilised by BIA to predict body water volumes is the proportional relationship for a simple cylindrical conductor, (volume oc length2/resistance), which allows the volume to be predicted from the measured resistance and length. Most of the research to date has measured the body's resistance to the passage of a 50· kHz AC current to predict total body water, (TBW). Several research groups have investigated the application of AC currents at lower frequencies, (eg 5 kHz), to predict extracellular water, (ECW). However all research to date using BIA to predict body water volumes has used the impedance measured at a discrete frequency or frequencies. This thesis investigates the variation of impedance and phase of biological systems over a range of frequencies and describes the development of a swept frequency bioimpedance meter which measures impedance and phase at 496 frequencies ranging from 4 kHz to 1 MHz. The impedance of any biological system varies with the frequency of the applied current. The graph of reactance vs resistance yields a circular arc with the resistance decreasing with increasing frequency and reactance increasing from zero to a maximum then decreasing to zero. Computer programs were written to analyse the measured impedance spectrum and determine the impedance, Zc, at the characteristic frequency, (the frequency at which the reactance is a maximum). The fitted locus of the measured data was extrapolated to determine the resistance, Ro, at zero frequency; a value that cannot be measured directly using surface electrodes. The explanation of the theoretical basis for selecting these impedance values (Zc and Ro), to predict TBW and ECW is presented. Studies were conducted on a group of normal healthy animals, (n=42), in which TBW and ECW were determined by the gold standard of isotope dilution. The prediction quotients L2/Zc and L2/Ro, (L=length), yielded standard errors of 4.2% and 3.2% respectively, and were found to be significantly better than previously reported, empirically determined prediction quotients derived from measurements at a single frequency. The prediction equations established in this group of normal healthy animals were applied to a group of animals with abnormally low fluid levels, (n=20), and also to a group with an abnormal balance of extra-cellular to intracellular fluids, (n=20). In both cases the equations using L2/Zc and L2/Ro accurately and precisely predicted TBW and ECW. This demonstrated that the technique developed using multiple frequency bioelectrical impedance analysis, (MFBIA), can accurately predict both TBW and ECW in both normal and abnormal animals, (with standard errors of the estimate of 6% and 3% for TBW and ECW respectively). Isotope dilution techniques were used to determine TBW and ECW in a group of 60 healthy human subjects, (male. and female, aged between 18 and 45). Whole body impedance measurements were recorded on each subject using the MFBIA technique and the correlations between body water volumes, (TBW and ECW), and heighe/impedance, (for all measured frequencies), were compared. The prediction quotients H2/Zc and H2/Ro, (H=height), again yielded the highest correlation with TBW and ECW respectively with corresponding standard errors of 5.2% and 10%. The values of the correlation coefficients obtained in this study were very similar to those recently reported by others. It was also observed that in healthy human subjects the impedance measured at virtually any frequency yielded correlations not significantly different from those obtained from the MFBIA quotients. This phenomenon has been reported by other research groups and emphasises the need to validate the technique by investigating its application in one or more groups with abnormalities in fluid levels. The clinical application of MFBIA was trialled and its capability of detecting lymphoedema, (an excess of extracellular fluid), was investigated. The MFBIA technique was demonstrated to be significantly more sensitive, (P<.05), in detecting lymphoedema than the current technique of circumferential measurements. MFBIA was also shown to provide valuable information describing the changes in the quantity of muscle mass of the patient during the course of the treatment. The determination of body composition, (viz TBW and ECW), by MFBIA has been shown to be a significant improvement on previous bioelectrical impedance techniques. The merit of the MFBIA technique is evidenced in its accurate, precise and valid application in animal groups with a wide variation in body fluid volumes and balances. The multiple frequency bioelectrical impedance analysis technique developed in this study provides accurate and precise estimates of body composition, (viz TBW and ECW), regardless of the individual's state of health.
Resumo:
A power filter is necessary to connect the output of a power converter to the grid so as to reduce the harmonic distortion introduced in the line current and voltage by the power converter. Many a times, a transformer is also present before the point of common coupling. Magnetic components often constitute a significant part of the overall weight, size and cost of the grid interface scheme. So, a compact inexpensive design is desirable. A higher-order LCL-filter and a transformer are increasingly being considered for grid interconnection of the power converter. This study proposes a design method based on a three-winding transformer, that generates an integrated structure that behaves as an LCL-filter, with both the filter inductances and the transformer that are merged into a single electromagnetic component. The parameters of the transformer are derived analytically. It is shown that along with a filter capacitor, the transformer parameters provide the filtering action of an LCL-filter. A single-phase full-bridge power converter is operated as a static compensator for performance evaluation of the integrated filter transformer. A resonant integrator-based single-phase phase locked loop and stationary frame AC current controller are employed for grid frequency synchronisation and line current control, respectively.
Resumo:
Micro- and nano-mechanical resonators have been proposed for a variety of applications ranging from mass sensing to signal processing. Often their actuation and/or detection involve external subsystems that are much larger than the resonator itself. We have designed a simple microcantilever resonator with integrated sensor and actuator, facilitating the integration of large arrays of resonators. This unique design can be manufactured with a low-cost fabrication process, involving just a single step of lithography. The bilayer cantilever of gold and silicon dioxide is used as piezoresistive sensor as well as thermal bimorph actuator. The ac current used for actuation and the dc current used for piezoresistive detection are separated in the frequency-domain using a bias-tee circuit configuration. The resonant response is measured by detecting the second harmonic of the actuation current using a lock-in amplifier.
Resumo:
O principal objetivo da tese está relacionado ao tratamento de águas oleosas através da eletrofloculação utilizando corrente alternada de frequência variável, o qual procurou explorar as potencialidades desta técnica. Com a crescente demanda por petróleo e seus derivados, é cada vez maior a produção dessas águas residuárias que, antes de serem descartadas, precisam ser submetidas a tratamento que satisfaçam aos requisitos legais. O trabalho apresentado descreve o levantamento bibliográfico e os resultados dos ensaios realizados, empregando o tratamento de eletrofloculação com a finalidade de remover as substâncias consideradas poluentes presentes nestes efluentes. O processo de eletrofloculação foi testado tanto para o tratamento em corrente continua quanto em corrente alternada de frequência variável em efluentes sintéticos e reais de alta salinidade, contendo teores elevados de óleos e graxas, turbidez e cor. Eficiências de redução de 99% para óleos e graxas, cor e turbidez foram obtidos utilizando eletrodos de alumínio. O processo de eletrofloculação demonstrou-se bastante vantajoso em função da alta condutividade que permite o tratamento com menor consumo energético. A tecnologia de eletrofloculação com corrente alternada quando comparada com a tecnologia de corrente contínua se mostrou muito eficiente em relação a economia no desgaste de massa de eletrodos, o que, dependendo do tempo de aplicação da corrente elétrica nas mesmas condições de estudo, houve redução de mais da metade do consumo.
Resumo:
Dissertação de Mestrado para obtenção do grau de Mestre em Engenharia Eletrotécnica Ramo Automação e Eletrónica Industrial
Resumo:
Dissertação para a obtenção do grau de Mestre em Engenharia Eletrotécnica Ramo de Automação e Eletrónica Industrial
Resumo:
La posible asociación entre el desarrollo de fibrilación auricular (FA) con la presencia de cardiopatía chagásica en una población portadora de dispositivos cardiacos de estimulación no está descrita. Se presenta un estudio de tipo cohorte retrospectivo realizado en la FCI que recopila las principales características clínicas de una población de pacientes con cardiopatía de variada etiología y portadores de dispositivos cardiacos buscando evaluar la incidencia de FA en presencia de cardiomiopatía de origen chagásico y no chagásico. A la fecha no se cuenta con una base de datos institucional ni regional que contenga las variables analizadas. Durante los 5 meses que duró la construcción de la base de datos se incluyeron 99 sujetos de investigación. Se implantaron 42 marcapasos bicamerales, 39 cardiodesfibriladores bicamerales, 6 dispositivos correspondientes cardiodesfibrilador con función de resincronización cardiaca, 2 resincronizadores cardiacos sin función de cardiodesfibrilador y 7 cardiodesfibriladores unicamerales. De los 99 sujetos recolectados se presentaron 8 desenlaces (FA de novo) y de esos solamente 1 pertenece al grupo de pacientes con cardiomiopatía chagásica. Este número reducido de desenlaces no permitió desarrollar un modelo de regresión de Cox y ni otros tipos de análisis estadísticos planteados en el protocolo inicial debido al bajo número de casos y pobre poder estadístico. Esta dificultad es inherente a la naturaleza del problema a estudiar y al corto tiempo de seguimiento. Por lo anterior no se puede establecer si existe una relación entre la presencia de serología positiva para infección por T. Cruzi y la presencia de FA de novo.