997 resultados para 8S-84


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The monograph includes the study of chemical and mineral compositions of terrestrial and marine manganese ores, methods of their analysis, dependence of manganese crust geochemistry on tectonic position of their formation, problems of manganese genesis and sources of manganese in ocean ores in connection with geohistorical aspects of ocean formation and development. A hypothesis is offered that formation of giant manganese mineral basins on continental margins resulted from a large asteroid fall to the ocean.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We examined differences in response latencies obtained during a validated video-based hazard perception driving test between three healthy, community-dwelling groups: 22 mid-aged (35-55 years), 34 young-old (65-74 years), and 23 old-old (75-84 years) current drivers, matched for gender, education level, and vocabulary. We found no significant difference in performance between mid-aged and young-old groups, but the old-old group was significantly slower than the other two groups. The differences between the old-old group and the other groups combined were independently mediated by useful field of view (UFOV), contrast sensitivity, and simple reaction time measures. Given that hazard perception latency has been linked with increased crash risk, these results are consistent with the idea that increased crash risk in older adults could be a function of poorer hazard perception, though this decline does not appear to manifest until age 75+ in healthy drivers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mineral delvauxite CaFe3+4(PO4,SO4)2(OH)8•4-6H2O has been characterised by Raman spectroscopy and infrared spectroscopy. The mineral is associated with the minerals diadochite and destinezite. Delvauxite appears to vary in crystallinity from amorphous to semi-crystalline. The mineral is often X-ray non-diffracting. The minerals are found in soils and may be described as ‘colloidal’ minerals. Vibrational spectroscopy enables determination of the molecular structure of delvauxite. Bands are assigned to phosphate and sulphate stretching and bending modes. Two symmetric stretching modes for both the phosphate and sulphate symmetric stretching modes support the concept of non-equivalent phosphate and sulphate units in the mineral structure. Multiple water bending and stretching modes imply that non-equivalent water molecules in the structure exist with different hydrogen bond strengths.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The two minerals borickyite and delvauxite CaFe3+4(PO4,SO4)2(OH)8•4-6H2O have the same formula. Are the minerals identical or different? The minerals borickyite and delvauxite have been characterised by Raman spectroscopy. The minerals are related to the minerals diadochite and destinezite. Both minerals are amorphous. Delvauxite appears to vary in crystallinity from amorphous to semi-crystalline. The minerals are often X-ray non-diffracting. The minerals are found in soils and may be described as ‘colloidal’ minerals. Vibrational spectroscopy enables an assessment of the molecular structure of borickyite and delvauxite. Bands are assigned to phosphate and sulphate stretching and bending modes. Multiple water bending and stretching modes imply that non-equivalent water molecules in the structure exist with different hydrogen bond strengths. The two minerals show differing spectra and must be considered as different minerals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is debate as to whether percutaneous coronary intervention (PCI) with drug-eluting stents or coronary artery bypass surgery (CABG) is the best procedure for subjects with type 2 diabetes and coronary artery disease requiring revascularization. There is some evidence that following these procedures there is less further revascularization with CABG than PCI in subjects with diabetes. Two recent studies; the FREEDOM (Future Revascularization Evaluation in patients with Diabetes mellitus: Optimal Management of Multivessel Disease) trial, and a trial using a real world diabetic population from a Registry, have shown that the benefits of CABG over PCI in subjects with type 2 diabetes extends to lower rates of death and myocardial infarct, in addition to lower rates of revascularization. However, the rates of stroke may be higher with CABG than PCI with drug-eluting stents in this population. Thus, if CABG is going to be preferred to PCI in subjects with type 2 diabetes and multivessel coronary disease, consideration should be given to how to reduce the rates of stroke with CABG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The title compound, C(14)H(17)FO(2), was obtained from anti-4a, 9a:8a,10a-diepoxy-1,4,4a,5,8,8a, 9,9a, 10,10a-decahydroanthracene via tandem hydrogen-fluoride-mediated epoxide ring-opening and transannular oxacyclization. With the two cyclohexene rings folded towards the oxygen bridge, the title tetracyclic fluoroalcohol molecule displays a conformation reminiscent of a pagoda. The crystal packing is effected via intermolecular O-H center dot center dot center dot O hydrogen bonds, which link the molecules into a zigzag chain along the b axis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An all-digital on-chip clock skew measurement system via subsampling is presented. The clock nodes are sub-sampled with a near-frequency asynchronous sampling clock to result in beat signals which are themselves skewed in the same proportion but on a larger time scale. The beat signals are then suitably masked to extract only the skews of the rising edges of the clock signals. We propose a histogram of the arithmetic difference of the beat signals which decouples the relationship of clock jitter to the minimum measurable skew, and allows skews arbitrarily close to zero to be measured with a precision limited largely by measurement time, unlike the conventional XOR based histogram approach. We also analytically show that the proposed approach leads to an unbiased estimate of skew. The measured results from a 65 nm delay measurement front-end indicate that for an input skew range of +/- 1 fan-out-of-4 (FO4) delay, +/- 3 sigma resolution of 0.84 ps can be obtained with an integral error of 0.65 ps. We also experimentally demonstrate that a frequency modulation on a sampling clock maintains precision, indicating the robustness of the technique to jitter. We also show how FM modulation helps in restoring precision in case of rationally related clocks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Here, we have discovered CXI-benzo-84 as a potential anticancer agent from a library of benzimidazole derivatives using cell based screening strategy. CXI-benzo-84 inhibited cell cycle progression in metaphase stage of mitosis and accumulated spindle assembly checkpoint proteins Mad2 and BubR1 on kinetochores, which subsequently activated apoptotic cell death in cancer cells. CXI-benzo-84 depolymerized both interphase and mitotic microtubules, perturbed EB1 binding to microtubules and inhibited the assembly and GTPase activity of tubulin in vitro. CXI-benzo-84 bound to tubulin at a single binding site with a dissociation constant of 1.2 +/- 0.2 mu M. Competition experiments and molecular docking suggested that CXI-benzo-84 binds to tubulin at the colchicine-site. Further, computational analysis provided a significant insight on the binding site of CXI-benzo-84 on tubulin. In addition to its potential use in cancer chemotherapy, CXI-benzo-84 may also be useful to screen colchicine-site agents and to understand the colchicine binding site on tubulin. (C) 2013 Elsevier Inc. All rights reserved.