973 resultados para 670400 Human Pharmaceutical Products
Resumo:
In a previous paper, Hoornaert et al. (Powder Technol. 96 (1998); 116-128) presented data from granulation experiments performed in a 50 L Lodige high shear mixer. In this study that same data was simulated with a population balance model. Based on an analysis of the experimental data, the granulation process was divided into three separate stages: nucleation, induction, and coalescence growth. These three stages were then simulated separately, with promising results. it is possible to derive a kernel that fit both the induction and the coalescence growth stage. Modeling the nucleation stage proved to be more challenging due to the complex mechanism of nucleus formation. From this work some recommendations are made for the improvement of this type of model.
Resumo:
The mechanical properties of a range of agglomerates and particulate coatings have been measured using a nanoindenter. The effect of formulation properties such as powder and binder properties on coating hardness is described. An attempt is also made to measure the fracture hardness with the nanoindenter. The use of indentation technology to measure fundamental agglomerate properties is critically analysed. Based on the indentation measurements and standard attrition test results, the coating hardness is found closely related to the attrition rate under standard conditions and can be used to screen different powder/binder formulations. (C) 2002 Elsevier Science B.V All rights reserved.
Resumo:
Granular gamma-Al2O3 support and 8 wt % CuO/gamma-Al2O3 catalyst were synthesized by a sol-gel granulation method. The pore structure, crush strength, hardness, and elasticity of these sol-gel-derived catalysts were studied and compared with similar commercial catalysts prepared by non-sol-gel methods. Alumina and CuO-coated alumina granular particles prepared by different methods have different macro- and microstructure. The sol-gel-derived granular gamma-alumina and CuO-coated gamma-alumina granular particles have a structure defined by compact packing of uniform, nanosized gamma-alumina crystallites. They are characterized by a more uniform pore size distribution and larger surface area as compared to similar commercial samples with a structure defined by packing of aggregates consisting of nonuniform gamma-alumina crystallites. Because of the differences in the macro- and microstructure, the sol-gel-derived granular samples offer higher crush strength and greater hardness than the commercial samples.
Resumo:
Nucleation is the first step in granulation where the powder and liquid first contact. Two types of nucleation in wet granulation processes are proposed. Drop controlled nucleation, where one drop forms one nucleus, occurs when drops hitting the powder surface do not overlap (low spray flux Psi(a)) and the drop must wet quickly into the bed (short drop penetration time t(p)). If either criterion is not met, powder mixing characteristics will dominate (mechanical dispersion regime). Granulation experiments were performed with lactose powder, water, PEG200, and 7% HPC solution in a 6 L and a 25 L mixer granulator. Size distributions were measured as the drop penetration time and spray flux were varied. At short penetration times, decreasing Psi(a) caused the nuclei distribution to become narrower. When drop penetration time was high, the nuclei size distribution was broad independent of changes in dimensionless spray flux. Nucleation regime maps were plotted for each set of experiments in each mixer as a function of the dimensionless distribution width delta. The nucleation regime map demonstrates the interaction between drop penetration time and spray flux in nucleation. The narrowest distribution consistently occurred at low spray flux and low penetration time, proving the existence of the drop controlled regime. The nucleation regime map provides a rational basis for design and scale-up of nucleation and wetting in wet granulation.
Resumo:
Particle flow patterns were investigated for wet granulation and dry powder mixing in ploughshare mixers using Positron Emission Particle Tracking (PEPT). In a 4-1 mixer, calcium carbonate with mean size 45 mum was granulated using a 50 wt.% solution of glycerol and water as binding fluid, and particle movement was followed using a 600-mum calcium hydroxy-phosphate tracer particle. In a 20-1 mixer, dry powder flow was studied using a 600-mum resin bead tracer particle to simulate the bulk polypropylene powder with mean size 600 mum. Important differences were seen between particle flow patterns for wet and dry systems. Particle speed relative to blade speed was lower in the wet system than in the dry system, with the ratios of average particle speed to blade tip speed for all experiments in the range 0.01-015. In the axial plane, the same particle motion was observed around each blade; this provides a significant advance for modelling flow in ploughshare mixers. For the future, a detailed understanding of the local velocity, acceleration and density variations around a plough blade will reveal the effects of flow patterns in granulating systems on the resultant distribution of granular product attributes such as size, density and strength. (C) 2002 Elsevier Science B.V All rights reserved.
Resumo:
The generic pharmaceutical value chain model has been employed to describe both the global pharmaceutical and biotechnology industries till now. This research investigates the organisational value chain in Australian biotechnology companies in order to assess the appropriateness of the pharmaceutical value chain to small-and medium-sized biotechnology companies. The main theme of the research is: Can a generic model of the organisational value chain be defined for the biotechnology industry? Emanating from the literature, two research propositions were developed. RP1: there are eight major definable elements/activities of the organisational value chain for the biotechnology industry. RP2: Coverage of the elements in the biotechnology value chain ranges from focused to broad. A multiple case study methodology was used to explore these propositions. To develop a number of case studies, data was collected from senior managers of small and medium Australian biotechnology companies using an interview instrument, as well as from publicly available documentation and through observation. The results were analysed using cross-case comparisons. The results showed that an aggregation of the value chains of each organisation can be reduced to these eight definable elements that constitute the biotechnology value chain: basic research, applied research, development, verification and validation, prototype development, clinical trials, manufacturing and marketing. However, the findings also indicate that these major elements of the value chain need to be further reduced into sub-activities or sub-tasks to cater for the unique differences between biotechnology companies. Generally, the findings were consistent with the literature. However, a wider sampling, including international biotechnology organisations should be studied. The major contribution of this research is in the development of a value chain model, including general sub-tasks, for the Australian biotechnology industry.
Resumo:
The potencies of mammalian cell-derived recombinant human erythropoietin pharmaceutical preparations, from a total of five manufacturers, were assessed by in vivo bioassay using standardized protocols. Eight-week-old normocythemic mice received a single subcutaneous injection followed by blood sampling 96 h later or multiple daily injections with blood sampling 24 h after the last injection. Reticulocyte counting by microscopic examination was employed as the end-point using the brilliant cresyl blue or selective hemolysis methods, together with automated flow cytometry. Different injection schedules were investigated and dose-response curves for the European Pharmacopoeia Biological Reference Preparation of erythropoietin were compared. Manual and automated methods of reticulocyte counting were correlated with respect to assay validity and precision. Using 8 mice per treatment group, intra-assay precision determined for all of the assays in the study showed coefficients of variation of 12.1-28.4% for the brilliant cresyl blue method, 14.1-30.8% for the selective hemolysis method and 8.5-19.7% for the flow cytometry method. Applying the single injection protocol, a combination of at least two independent assays was required to achieve the precision potency and confidence limits indicated by the manufacturers, while the multiple daily injection protocol yielded the same acceptable results within a single assay. Although the latter protocol using flow cytometry for reticulocyte counting gave more precise and reproducible results (intra-assay coefficients of variation: 5.9-14.2%), the well-characterized manual methods provide equally valid alternatives for the quality control of recombinant human erythropoietin therapeutic products.
Resumo:
Losartan is an antihypertensive agent that lost its patent protection in 2010, and, consequently, it has been available in generic form. The latter motivated the search for a rapid and precise alternative method. Here, a simple conductometric titration in aqueous medium is described for the losartan analysis in pharmaceutical formulations. The first step of the titration occurs with the protonation of losartan producing a white precipitate and resulting in a slow increase in conductivity. When the protonation stage is complete, a sharp increase in conductivity occurs which was determined to be due to the presence of excess of acid. The titrimetric method was applied to the determination of losartan in pharmaceutical products and the results are comparable with values obtained using a chromatographic method recommended by the United States Pharmacopoeia. The relative standard deviation for successive measurements of a 125 mg L-1 (2.71x10(-4) mol L-1) losartan solution was approximately 2%. Recovery study in tablet samples ranged between 99 and 102.4%. The procedure is fast, simple, and represents an attractive alternative for losartan quantification in routine analysis. In addition, it avoids organic solvents, minimizes the risk of exposure to the operator, and the waste treatment is easier compared to classical chromatographic methods.
Resumo:
The electrochemical behavior of citalopram was studied by square-wave and square-wave adsorptive-stripping voltammetry (SWAdSV). Citalopram can be reduced and accumulated at a mercury drop electrode, with a maximum peak current intensity being obtained at a potential of approximately -1.25V vs. AgCl/Ag, in an aqueous electrolyte solution of pH 12. A SWAdSV method has been developed for the determination of citalopram in pharmaceutical preparations. The method shows a linear range between 1.0x10-7 and 2.0x10-6 mol L-1 with a limit of detection of 5x10-8 mol L-1 for an accumulation time of 30 s. The precision of the method was evaluated by assessing the repeatability and intermediate precision, achieving good relative standard deviations in all cases (≤2.3%). The proposed method was applied to the determination of citalopram in five pharmaceutical products and the results obtained are in good agreement with the labeled values.
Resumo:
Aiming the establishment of simple and accurate readings of citric acid (CA) in complex samples, citrate (CIT) selective electrodes with tubular configuration and polymeric membranes plus a quaternary ammonium ion exchanger were constructed. Several selective membranes were prepared for this purpose, having distinct mediator solvents (with quite different polarities) and, in some cases, p-tert-octylphenol (TOP) as additive. The latter was used regarding a possible increase in selectivity. The general working characteristics of all prepared electrodes were evaluated in a low dispersion flow injection analysis (FIA) manifold by injecting 500µl of citrate standard solutions into an ionic strength (IS) adjuster carrier (10−2 mol l−1) flowing at 3ml min−1. Good potentiometric response, with an average slope and a repeatability of 61.9mV per decade and ±0.8%, respectively, resulted from selective membranes comprising additive and bis(2-ethylhexyl)sebacate (bEHS) as mediator solvent. The same membranes conducted as well to the best selectivity characteristics, assessed by the separated solutions method and for several chemical species, such as chloride, nitrate, ascorbate, glucose, fructose and sucrose. Pharmaceutical preparations, soft drinks and beers were analyzed under conditions that enabled simultaneous pH and ionic strength adjustment (pH = 3.2; ionic strength = 10−2 mol l−1), and the attained results agreed well with the used reference method (relative error < 4%). The above experimental conditions promoted a significant increase in sensitivity of the potentiometric response, with a supra-Nernstian slope of 80.2mV per decade, and allowed the analysis of about 90 samples per hour, with a relative standard deviation <1.0%.
Resumo:
Dissertação para obtenção do Grau de Mestre em Genética Molecular e Biomedicina