991 resultados para 532


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 1986, the Iowa DOT installed 700 feet of International Barrier Corporation (IBC) barrier between the 1-235 eastbound off ramp and the adjacent eastbound loop on ramp at 8th Street in West Des Moines. It is a 3 foot 6 inch high sand-filled galvanized sheet metal barrier. The bid price on this project was $130 per lineal foot. It was evaluated annually for four years. During this time, there have been no severe accidents where vehicles hit the barrier. There are scrapes and dents indicating minor accidents. The barrier has performed very well and required no maintenance. Due to its initial cost, the IBC barrier is not as cost-effective as portland cement concrete barrier rails.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the intraocular pressure (IOP)-lowering effect of modified goniopuncture with the 532-nm Nd : YAG selective laser trabeculoplasty (SLT) laser on eyes after deep sclerectomy with collagen implant (DSCI). This was an interventional cased series. The effects of modified goniopuncture on eyes with insufficient IOP-lowering after DSCI were observed. Goniopuncture was performed using a Q-switched, frequency-doubled 532-nm Nd : YAG laser (SLT-goniopuncture, SLT-G). Outcome measures were amount of IOP-lowering and rapidity of decrease after laser intervention. In all, 10 eyes of 10 patients with a mean age of 71.0±7.7 (SD) years were treated with SLT-G. The mean time of SLT-G after DSCI procedure was 7.1±10.9 months. SLT-G decreased IOP from an average of 16.1±3.4 mm Hg to 14.2±2.8 mm Hg (after 15 min), 13.6±3.9 mm Hg (at 1 day), 12.5±4.1 mm Hg (at 1 month), and 12.6±2.5 (at 6 months) (P<0.0125). There were no complications related to the intervention. Patients in this series achieved an average 22.5% of IOP reduction after SLT-G. The use of the SLT laser appears to be an effective and safe alternative to the traditional Nd : YAG laser for goniopuncture in eyes after DSCI, with potential advantages related to non-perforation of trabeculo-descemet's membrane (TDM).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The members of the Iowa Concrete Paving Association, the National Concrete Pavement Technology Center Research Committee, and the Iowa Highway Research Board commissioned a study to examine alternative ways of developing transverse joints in portland cement concrete pavements. The present study investigated six separate variations of vertical metal strips placed above and below the dowels in conventional baskets. In addition, the study investigated existing patented assemblies and a new assembly developed in Spain and used in Australia. The metal assemblies were placed in a new pavement and allowed to stay in place for 30 days before the Iowa Department of Transportation staff terminated the test by directing the contractor to saw and seal the joints. This report describes the design, construction, testing, and conclusions of the project.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated the tolerability and angiotensin II antagonist activity of oral DuP 532 in healthy male subjects. DuP 532 (1 to 200 mg) was well tolerated, with no effect on blood pressure or heart rate. Compared with losartan (100 mg), DuP 532 (200 mg) was a weak antagonist of pressor responses to intravenous angiotensin II. Maximum inhibition of diastolic pressor response was 86% (95% confidence interval [CI], 84%, 88%) approximately 4.6 hours after losartan and 48% (95% CI, 38%, 56%) 8.7 hours after DuP 532. Twenty-four hours after dosing, inhibition by losartan and DuP 532 was similar (40% to 45%). DUP 532 is extensively bound in human plasma, with an in vitro free fraction of 0.06. Although DuP 532 and EXP3174 (losartan's active metabolite) have similar AT1-receptor potency, and plasma concentrations of DuP 532 were much greater than losartan/EXP3174, the level of antagonism was much less for DuP 532. These results indicate that multiple factors determine the in vivo potency of angiotensin II antagonists, including affinity for and distribution to the receptor as modulated by plasma binding.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the early 1970's, Canadians have expressed many concerns about the growth of government and its impact on their daily lives. The public has requested increased access to government documents and improved protection of the personal information which is held in government files and data banks. At the same time, both academics and practitioners in the field of public administration have become more interested in the values that public servants bring to their decisions and recommendations. Certain administrative values, such as accountability and integrity, have taken on greater relative importance. The purpose of this thesis is to examine the implementation of Ontario's access and privacy law. It centres on the question of whether or not the Freedom of Information and Protection of Privacy Act, 1987, (FIPPA) has answered the demand for open access to government while at the same time protecting the personal privacy of individual citizens. It also assesses the extent to which this relatively new piece of legislation has made a difference to the people of Ontario. The thesis presents an overview of the issues of freedom of information and protection of privacy in Ontario. It begins with the evolution of the legislation and a description of the law itself. It focuses on the structures and processes which have been established to meet the procedural and administrative demands of the Act. These structures and processes are evaluated in two ways. First, the thesis evaluates how open the Ontario government has become and, second, it determines how Ill carefully the privacy rights of individuals are safeguarded. An analytical framework of administrative values is used to evaluate the overall performance of the government in these two areas. The conclusion is drawn that, overall, the Ontario government has effectively implemented the Freedom of Information and Protection of Privacy Act, particularly by providing access to most government-held documents. The protection of individual privacy has proved to be not only more difficult to achieve, but more difficult to evaluate. However, the administrative culture of the Ontario bureaucracy is shown to be committed to ensuring that the access and privacy rights of citizens are respected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polymethyl methacrylate (PMMA) optical fibres are fabricated by a preform drawing process. The Raman spectra of PMMA fibres are recorded using a diode pumped solid state laser emitting at 532 nm and a CCD-spectrograph in the 400–3800 cm−1 range. The variation of the Raman intensity with the length of the optical fibre is studied. Investigations are carried out on the variation of FWHM of the Raman peak at 2957 cm−1 with the length of the optical fibre and pump power. The differential scattering cross section and gain coefficient of the Raman peak at 2957 cm−1 in PMMA are calculated in relation to that of toluene.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polymethyl methacrylate (PMMA) optical fibres are fabricated by a preform drawing process. The Raman spectra of PMMA fibres are recorded using a diode pumped solid state laser emitting at 532 nm and a CCD-spectrograph in the 400–3800 cm−1 range. The variation of the Raman intensity with the length of the optical fibre is studied. Investigations are carried out on the variation of FWHM of the Raman peak at 2957 cm−1 with the length of the optical fibre and pump power. The differential scattering cross section and gain coefficient of the Raman peak at 2957 cm−1 in PMMA are calculated in relation to that of toluene

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The nonlinear (NL) optical properties of glassy xBi2O 3-(1-x) GeO2 with x = 0.72 and 0.82 were investigated. The experiments were performed with lasers at 800 nm (pulses of 150 fs) and 532 nm (pulses of 80 ps and 250 ns). Using the Kerr gate technique, we observed that the NL response of the samples at 800 nm is faster than 150 fs. NL refraction indices, | n 2 | ≈ 5 × 10-16 cm2/W, and two-photon absorption coefficients, α 2, smaller than 0.03 cm/GW, were measured at 800 nm. At 532 nm, we measured the NL transmittance of the samples. From the results obtained, we determined α 2 ≈1 cm/GW and excited-state absorption cross-sections of ≈10-22 cm2 due to free-carriers. © 2013 AIP Publishing LLC.