8 resultados para 52901
Resumo:
In Experiments 1, 2, and 3, we evaluated the effects of temporary weaning (TW), equine chorionic gonadotropin (eCG), and follicle-stimulating hormone (FSH) treatments on results of it fixed-time artificial insemination (TAI) protocol in postpartum Bos indicus cows. In Experiment 1, treatment with 400 IU eCG or with TW for 48 h consistently improved pregnancy rates (PRs) at TAI, but, in Experiment 2, FSH treatment was less effective than eCG or TW. In Experiment 3, the inclusion of eCG treatment in cows subjected to TW did not improve PRs. We concluded that TW or 400 IU eCG should be included in the TAI protocol in postpartum Bos indicus cows to enhance fertility. In Experiment 4, we used records front heifers and cows treated with the proposed protocol during the 2006-2007 (n = 27,195) and 2007-2008 (n = 36,838) breeding seasons from multiple locations in Brazil to evaluate factors potentially affecting PRs. Overall PR at TAI was 49.6% (31,786 of 64,033). Pregnancy rate differed (P < 0.01) among farm within location (results ranging between 26.8% and 68.0%; P < 0.01), cow group within farm, by breed (Bos indicus, 48.3% [26,123 of 54,145]; Bos taurus, 61.7% [3652 of 5922]; and crossbred Bos indicus x Bos taurus, 50.7% [2011 of 3966]), category (nulliparous, 39.6% [2095 of 52901] suckled primiparous, 45.2% [3924 of 8677]; suckled multiparous, 51.8% [24,245 of 46,767]; and nonsuckled multiparous, 46.1% [1522 of 3299]), body condition score at TAI (<= 2.5 43.0% [3409 of 7923]; 3.0, 49.6% [18,958 of 38,229]; and >3.5, 52.7% [9419 of 17,881]). Days postpartum at beginning, of protocol did not affect PR (30 to 60 d, 47.6% [4228 of 8881]; 61 to 90 d, 51.7% 116,325 to 31,5721; and 91 to 150 d, 50.8% [7616 to 14,991]; P > 0.1). Pregnancy rate was also consistently affected (P < 0.01) by sire (results ranging from 7.2% to 77.3%) and artificial insemination technician (results ranging from 15.1% to 81.8%). (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
The clinical demand for a device to monitor Blood Pressure (BP) in ambulatory scenarios with minimal use of inflation cuffs is increasing. Based on the so-called Pulse Wave Velocity (PWV) principle, this paper introduces and evaluates a novel concept of BP monitor that can be fully integrated within a chest sensor. After a preliminary calibration, the sensor provides non-occlusive beat-by-beat estimations of Mean Arterial Pressure (MAP) by measuring the Pulse Transit Time (PTT) of arterial pressure pulses travelling from the ascending aorta towards the subcutaneous vasculature of the chest. In a cohort of 15 healthy male subjects, a total of 462 simultaneous readings consisting of reference MAP and chest PTT were acquired. Each subject was recorded at three different days: D, D+3 and D+14. Overall, the implemented protocol induced MAP values to range from 80 ± 6 mmHg in baseline, to 107 ± 9 mmHg during isometric handgrip maneuvers. Agreement between reference and chest-sensor MAP values was tested by using intraclass correlation coefficient (ICC = 0.78) and Bland-Altman analysis (mean error = 0.7 mmHg, standard deviation = 5.1 mmHg). The cumulative percentage of MAP values provided by the chest sensor falling within a range of ±5 mmHg compared to reference MAP readings was of 70%, within ±10 mmHg was of 91%, and within ±15mmHg was of 98%. These results point at the fact that the chest sensor complies with the British Hypertension Society (BHS) requirements of Grade A BP monitors, when applied to MAP readings. Grade A performance was maintained even two weeks after having performed the initial subject-dependent calibration. In conclusion, this paper introduces a sensor and a calibration strategy to perform MAP measurements at the chest. The encouraging performance of the presented technique paves the way towards an ambulatory-compliant, continuous and non-occlusive BP monitoring system.
Resumo:
One of the main features of the Greek currency are the big differences between emissions of the polis, which did not match either in their iconographic message types, not even in the met-rical pattern of their values. These differences were reflected in exchange systems ruled by the main sanctuaries that shrines stipu-lated thus giving official status to change.
Resumo:
A Temperatura da Superfície Terrestre (TST), além de ser uma componente importante no balanço de energia na superfície, modula a temperatura do ar nas camadas mais baixas da atmosfera. O objetivo do presente trabalho foi analisar a variação da temperatura de superfície em Diferentes Usos e Cobertura do Solo na Floresta Nacional do Tapajós e seu Entorno. Utilizou-se sensores ?Thermal Infrared Sensor? dos satélites Ladsat 5 e 8 através dos ?softwares? PCI Geomatica 2015 e o QGis 2.8. Fez-se campanha de campo para obtenção de imagens termogéficas no infravermelho (câmera ThermoVision, modelo A320). Os resultados apontaram maior variabilidade espacial de TST em função da heterogeneidade do uso da terra como a agricultura anual, pecuária extensiva, dentre outros. Os resultados evidenciaram uma amplitude térmica de 13ºC na FNT+ZA. Em área de Floretas, vegetação secundária, pasto, agricultura anual as maiores variações térmicas (TST) chegaram a valores de 25ºC, 26ºC, 35ºC e 33ºC, respectivamente. A amplitude térmica na FNT foi de 5ºC e na Zona de Amortecimento de 20º, indicando perdas na cobertura vegetal, principalmente na porção nordeste da ZA. Nas áreas de proteção legal a variação de TST foi entre 19ºC a 29ºC. Conclui-se que na FLONA Tapajós a manutenção da cobertura florestal reduz as amplitudes térmicas. Por outro lado, as extensas áreas com pastagens e cultivos anuais na porção nordeste da FLONA apresentam as maiores variações espaciais da TST na Zona de Amortecimento que podem comprometer o microclima na FNT+ZA