973 resultados para 50 kHz
Resumo:
Fifty kHz rat vocalizations are theorized to reflect a positive affective state, and index the reward value of stimuli (Knutson, Burgdorf & Panksepp, 2002; Panksepp & Burgdorf, 2003; Brudzynski,2005). Previous studies have identified the neurochemical substrate of this behaviour to be dependent on dopaminergic activity at the nucleus accumbens shell (Burgdorf, Knutson, Panksepp & Ikemoto, 2001; Thompson, Leonard & Brudzynski, 2006). The utilization of d-amphetamine (a non-selective dopamine agonist) in these studies does not address the specific dopamine receptor types involved. The present study aims to identify the role of the D2- like family of receptors in the nucleus accumbens shell in the production of 50 kHz vocalizations in adult rats. Single injections of quinpirole in a saline vehicle were administered to the nucleus accumbens shell of 57 rats, and the number of 50 kHz vocalizations were recorded. An inverted V-shaped relationship was found between quinpirole dose (0.5 ~g, 3 ~g, 6 ~g, 1 0 ~g and 20 ~g, all in 0.2~1 saline) and the mean number of 50 kHz calls produced. Quinpirole successfully elicited significantly more 50 kHz calls than did a saline control at the 6 ~g dose, as did 7 ~g/0.2 ~l of d-amphetamine injections into the same brain site. To test whether a selective D2 antagonist could reverse elicited 50 kHz calling, double injections were given that used either saline or raclopride as a pretreatment before quinpirole injections. Saline followed by 6 ~g/0.2 ~l of quinpirole elicited significantly more 50 kHz vocalizations than did a double injection of saline, while pretreatment with an equimolar dose of raclopride reduced elicited calls to control levels. Raclopride was also used as a pretreatment of 7 ~g/0.2 ~l d-amphetamine, which elicited significantly fewer 50 kHz vocalizations than saline followed by amphetamine, replicating the finding of Thompson, Leonard & Brudzynski (2006).Subcutaneous injections of 0.5 mg/kg and 1.5 mg/kg of quinpirole produced a similar number of 50 kHz vocalizations as subcutaneous injection of saline. Wider dose ranges may be explored in fiiture research. Thus, direct activation of the Da-like receptors in the nucleus accumbens shell was sufficient to elicit 50 kHz vocalizations in adult rats, an effect which was reversed with selective local antagonism of Da-like receptors. The Da-like receptor family also appears necessary for pharmacological activation of 50 kHz calling, as d-amphetamine was no longer able to effectively elicit these vocalizations from the nucleus accumbens shell when the Da-receptor family was antagonized with raclopride. The acoustic parameters of elicited vocalizations remained typical of rat 50 kHz calls. Detailed analyses of the acoustic characteristics of elicited calls indicated significant increases in call duration and peak frequency across drug injection groups, particularly among quinpirole dose groups. The implications of these findings are not yet clear, but may represent an important direction for future research into the coding of semiotic content into affective signals in rats.
Resumo:
Rats emit two distinct types of ultrasonic vocalizations in adulthood: 22 kHz (aversive situation), and 50 kHz calls (appetitive situation). The present project is focussed on pharmacological studies of 50 kHz vocalizations. The 50 kHz calls are elicited from dopaminergic activation in the meso limbic pathway and are emitted in such appetitive situations as social contact(s), sexual encounters, food reward, etc. Eighty-five male rats were stereotaxically implanted with bilateral guide cannulae in the nucleus accumbens shell (A= 9.7, L= 1.2, V= 6.7). Quinpirole, a D2/D3 dopaminergic agonist, was injected in low doses to the nucleus accumbens shell in an attempt to elicit 50 kHz vocalizations. A dose response was obtained for the low dose range of quinpirole for six doses: 0.025 Jlg, 0.06 Jlg, 0.12 Jlg, 0.25 Jlg, 0.5 Jlg, and 1.0 Jlg. It was found that only application of the 0.25 Jlg dose of quinpirole and the 7 Jlg dose of amphetamine (positive control) significantly increased the total number of 50 kHz calls (p < 0.006 and p < 0.004 respectively); and particularly significantly increased the frequency modulated type of these calls (p < 0.01, and p < 0.006 respectively). In a double injection procedure, the dose of 0.25 Jlg quinpirole was antagonized with raclopride (D2 antagonist) or U99194A maleate (D3 antagonist) in an attempt to antagonize the response. The 0.25 Jlg dose of quinpirole was successfully antagonized by pre-treatment with an equimolar dose of U99194A maleate (p < 0.008) but not with raclopride. The 7Jlg amphetamine response was also antagonized with an equimolar dose of raclopride. Based on these results, it seems that low doses of quinpirole, particularly the 0.25 Jlg dose, are capable of increasing 50 kHz vocalizations in rats and do so by activation of the D3 dopamine receptor. This is not a biphasic response as seen with locomotor studies. Also noteworthy is the increase in frequency modulated 50 kHz calls elicited by the 0.25 Jlg dose of quinpirole indicating a possible increase in positive affect.
Resumo:
There is extensive evidence that the mesolimbic dopamine system underlies the production of 50 kHz ultrasonic vocalizations in rats. In particular, the shell of the nucleus accumbens is associated with generation of frequency modulated 50 kHz calls (a specific type of 50 kHz call which can be subdivided into various subtypes). There is also evidence that amphetamine administered systemically preferentially increases the proportion of trill and step calls compared to other frequency modulated 50 kHz subtypes. The purpose of this study was to investigate the effect of drug administration route and the role of the nucleus accumbens shell in amphetamine-induced 50 kHz call profile in the rat. Three experiments investigated this by using subcutaneous and intra-accumbens microinjections of amphetamine, as well as procaine (a local anesthetic) blockade of the nucleus accumbens. Ultrasonic vocalizations were recorded digitally from 24 rats and were analysed for sonographic structure based on general call parameters. The results of the three experiments were partially supportive of the hypotheses. Systemic amphetamine was found to induce greater bandwidth in 50 kHz calling compared to spontaneous calls in a vehicle condition. Systemic amphetamine was also found to preferentially increase the proportion of trill and step subtypes compared to vehicle. Moreover, there was no difference in the proportions of 50 kHz subtypes resulting from intracerebral or systemic application of amphetamine. There was, however, a significant difference for bandwidth, with systemic amphetamine inducing greater bandwidth over intraaccumbens application. Procaine blockade of the nucleus accumbens shell paired with subcutaneous amphetamine produced no difference in bandwidth of calls compared with those after a vehicle pre-treatment similarly paired. There was no reduction in the proportions of trill and step 50 kHz subtypes as well, with the procaine condition showing significantly greater proportion of step calls. The results of the study support a role for the iii nucleus accumbens shell in the amphetamine-induced changes on 50 kHz call profile. They also indicate there are more regions and pathways involved in generating 50 kHz calls than the projections from the ventral tegmental area to the nucleus accumbens. The implications of this work are that frequency modulated 50 kHz subtypes may be generated by distinct neurophysiological mechanisms and may represent a profitable avenue for investigating different circuits of 50 kHz call categories in the rat.
Resumo:
The production of 50 kHz ultrasonic vocalizations in rats has been associated with both positive social interactions and appetitive behavioural situations. Furthermore, there is significant evidence showing that these vocalizations are controlled by the meso-limbic dopamine system. The purpose of this study was to perform a pharmacological analysis of 50 kHz calls by using dopamine and two dopamine agonists amphetamine and apomorphine, to induce calls. The acoustic parameters of the different call types were compared across each agonist. All three agonists were able to significantly induce more 50 kHz vocalizations compared to the vehicle control. Furthermore, calls elicited by apomorphine had a significantly higher bandwidth compared to those elicited by dopamine and amphetamine. All three agonists also had significantly different pharmacokinetic properties. These observations suggest that the D2 receptor sub-type is involved in the length of call bandwidths.
Resumo:
The analysis of the feasibility and economics of amorphous core power transformers for induction heating applications in the field 10-50 kHz is developped. The results obtained on a 25 kHz-150 kVA concentric winding trial unit are presented. © 1990.
Resumo:
Bioelectrical impedance analysis, (BIA), is a method of body composition analysis first investigated in 1962 which has recently received much attention by a number of research groups. The reasons for this recent interest are its advantages, (viz: inexpensive, non-invasive and portable) and also the increasing interest in the diagnostic value of body composition analysis. The concept utilised by BIA to predict body water volumes is the proportional relationship for a simple cylindrical conductor, (volume oc length2/resistance), which allows the volume to be predicted from the measured resistance and length. Most of the research to date has measured the body's resistance to the passage of a 50· kHz AC current to predict total body water, (TBW). Several research groups have investigated the application of AC currents at lower frequencies, (eg 5 kHz), to predict extracellular water, (ECW). However all research to date using BIA to predict body water volumes has used the impedance measured at a discrete frequency or frequencies. This thesis investigates the variation of impedance and phase of biological systems over a range of frequencies and describes the development of a swept frequency bioimpedance meter which measures impedance and phase at 496 frequencies ranging from 4 kHz to 1 MHz. The impedance of any biological system varies with the frequency of the applied current. The graph of reactance vs resistance yields a circular arc with the resistance decreasing with increasing frequency and reactance increasing from zero to a maximum then decreasing to zero. Computer programs were written to analyse the measured impedance spectrum and determine the impedance, Zc, at the characteristic frequency, (the frequency at which the reactance is a maximum). The fitted locus of the measured data was extrapolated to determine the resistance, Ro, at zero frequency; a value that cannot be measured directly using surface electrodes. The explanation of the theoretical basis for selecting these impedance values (Zc and Ro), to predict TBW and ECW is presented. Studies were conducted on a group of normal healthy animals, (n=42), in which TBW and ECW were determined by the gold standard of isotope dilution. The prediction quotients L2/Zc and L2/Ro, (L=length), yielded standard errors of 4.2% and 3.2% respectively, and were found to be significantly better than previously reported, empirically determined prediction quotients derived from measurements at a single frequency. The prediction equations established in this group of normal healthy animals were applied to a group of animals with abnormally low fluid levels, (n=20), and also to a group with an abnormal balance of extra-cellular to intracellular fluids, (n=20). In both cases the equations using L2/Zc and L2/Ro accurately and precisely predicted TBW and ECW. This demonstrated that the technique developed using multiple frequency bioelectrical impedance analysis, (MFBIA), can accurately predict both TBW and ECW in both normal and abnormal animals, (with standard errors of the estimate of 6% and 3% for TBW and ECW respectively). Isotope dilution techniques were used to determine TBW and ECW in a group of 60 healthy human subjects, (male. and female, aged between 18 and 45). Whole body impedance measurements were recorded on each subject using the MFBIA technique and the correlations between body water volumes, (TBW and ECW), and heighe/impedance, (for all measured frequencies), were compared. The prediction quotients H2/Zc and H2/Ro, (H=height), again yielded the highest correlation with TBW and ECW respectively with corresponding standard errors of 5.2% and 10%. The values of the correlation coefficients obtained in this study were very similar to those recently reported by others. It was also observed that in healthy human subjects the impedance measured at virtually any frequency yielded correlations not significantly different from those obtained from the MFBIA quotients. This phenomenon has been reported by other research groups and emphasises the need to validate the technique by investigating its application in one or more groups with abnormalities in fluid levels. The clinical application of MFBIA was trialled and its capability of detecting lymphoedema, (an excess of extracellular fluid), was investigated. The MFBIA technique was demonstrated to be significantly more sensitive, (P<.05), in detecting lymphoedema than the current technique of circumferential measurements. MFBIA was also shown to provide valuable information describing the changes in the quantity of muscle mass of the patient during the course of the treatment. The determination of body composition, (viz TBW and ECW), by MFBIA has been shown to be a significant improvement on previous bioelectrical impedance techniques. The merit of the MFBIA technique is evidenced in its accurate, precise and valid application in animal groups with a wide variation in body fluid volumes and balances. The multiple frequency bioelectrical impedance analysis technique developed in this study provides accurate and precise estimates of body composition, (viz TBW and ECW), regardless of the individual's state of health.
Resumo:
Background: Bioimpedance techniques provide a reliable method of assessing unilateral lymphedema in a clinical setting. Bioimpedance devices are traditionally used to assess body composition at a current frequency of 50 kHz. However, these devices are not transferable to the assessment of lymphedema, as the sensitivity of measuring the impedance of extracellular fluid is frequency dependent. It has previously been shown that the best frequency to detect extracellular fluid is 0 kHz (or DC). However, measurement at this frequency is not possible in practice due to the high skin impedance at DC, and an estimate is usually determined from low frequency measurements. This study investigated the efficacy of various low frequency ranges for the detection of lymphedema. Methods and Results: Limb impedance was measured at 256 frequencies between 3 kHz and 1000 kHz for a sample control population, arm lymphedema population, and leg lymphedema population. Limb impedance was measured using the ImpediMed SFB7 and ImpediMed L-Dex® U400 with equipotential electrode placement on the wrists and ankles. The contralateral limb impedance ratio for arms and legs was used to calculate a lymphedema index (L-Dex) at each measurement frequency. The standard deviation of the limb impedance ratio in a healthy control population has been shown to increase with frequency for both the arm and leg. Box and whisker plots of the spread of the control and lymphedema populations show that there exists good differentiation between the arm and leg L-Dex measured for lymphedema subjects and the arm and leg L-Dex measured for control subjects up to a frequency of about 30 kHz. Conclusions: It can be concluded that impedance measurements above a frequency of 30 kHz decrease sensitivity to extracellular fluid and are not reliable for early detection of lymphedema.
Resumo:
The aim of the study was to examine differences in total body water (TBW) measured using single-frequency (SF) and multi-frequency (MF) modes of bioelectrical impedance spectroscopy (BIS) in children and adults measured in different postures using the deuterium (2H) dilution technique as the reference. Twenty-three boys and 26 adult males underwent assessment of TBW using the dilution technique and BIS measured in supine and standing positions using two frequencies of the SF mode (50 kHz and 100 kHz) and the MF mode. While TBW estimated from the MF mode was comparable, extra-cellular fluid (ECF) and intra-cellular fluid (ICF) values differed significantly (p < 0.01) between the different postures in both groups. In addition, while estimated TBW in adult males using the MF mode was significantly (p < 0.01) greater than the result from the dilution technique, TBW estimated using the SF mode and prediction equation was significantly (p < 0.01) lower in boys. Measurement posture may not affect estimation of TBW in boys and adult males, however, body fluid shifts may still occur. In addition, technical factors, including selection of prediction equation, may be important when TBW is estimated from measured impedance.
Resumo:
Raw data from SeaScan™ transects off Wide Bay (south Queensland) taken in August 2007 as part of a study of ecological factors influencing the distribution of spanner crabs (Ranina ranina). The dataset (comma-delimited ascii file) comprises the following fields: 1. record number 2. date-time (GMT) 3. date-time (AEST) 4. latitude (signed decimal degrees) 5. longitude (decimal degrees) 6. speed over ground (knots) 7. depth (m) 8. seabed roughness (v) 9. hardness (v) Indices of roughness and hardness (from the first and second echoes respectively) were obtained using a SeaScan™ 100 system (un-referenced) on board the Research Vessel Tom Marshall, with the ship’s Furuno FCV 1100 echo sounder and 1 kW, 50 kHz transducer. Generally vessel speed was kept below about 14 kt (typically ~12 kt), and the echo-sounder range set to 80 m. The data were filtered to remove errors due to data drop-out, straying beyond system depth limits (min. 10 m), or transducer interference.
Resumo:
A simple analog instrumentation for Electrical Impedance Tomography is developed and calibrated using the practical phantoms. A constant current injector consisting of a modified Howland voltage controlled current source fed by a voltage controlled oscillator is developed to inject a constant current to the phantom boundary. An instrumentation amplifier, 50 Hz notch filter and a narrow band pass filter are developed and used for signal conditioning. Practical biological phantoms are developed and the forward problem is studied to calibrate the EIT-instrumentation. An array of sixteen stainless steel electrodes is developed and placed inside the phantom tank filled with KCl solution. 1 mA, 50 kHz sinusoidal current is injected at the phantom boundary using adjacent current injection protocol. The differential potentials developed at the voltage electrodes are measured for sixteen current injections. Differential voltage signal is passed through an instrumentation amplifier and a filtering block and measured by a digital multimeter. A forward solver is developed using Finite Element Method in MATLAB7.0 for solving the EIT governing equation. Differential potentials are numerically calculated using the forward solver with a simulated current and bathing solution conductivity. Measured potential data is compared with the differential potentials calculated for calibrating the instrumentation to acquire the voltage data suitable for better image reconstruction.
Resumo:
This paper presents a study on the uncertainty in material parameters of wave propagation responses in metallic beam structures. Special effort is made to quantify the effect of uncertainty in the wave propagation responses at high frequencies. Both the modulus of elasticity and the density are considered uncertain. The analysis is performed using a Monte Carlo simulation (MCS) under the spectral finite element method (SEM). The randomness in the material properties is characterized by three different distributions, the normal, Weibull and extreme value distributions. Their effect on wave propagation in beams is investigated. The numerical study shows that the CPU time taken for MCS under SEM is about 48 times less than for MCS under a conventional one-dimensional finite element environment for 50 kHz loading. The numerical results presented investigate effects of material uncertainties on high frequency modes. A study is performed on the usage of different beam theories and their uncertain responses due to dynamic impulse load. These studies show that even for a small coefficient of variation, significant changes in the above parameters are noticed. A number of interesting results are presented, showing the true effects of uncertainty response due to dynamic impulse load.
Resumo:
A Radio Frequency (RF) based digital data transmission scheme with 8 channel encoder/decoder ICs is proposed for surface electrode switching of a 16-electrode wireless Electrical Impedance Tomography (EIT) system. A RF based wireless digital data transmission module (WDDTM) is developed and the electrode switching of a EIT system is studied by analyzing the boundary data collected and the resistivity images of practical phantoms. An analog multiplexers based electrode switching module (ESM) is developed with analog multiplexers and switched with parallel digital data transmitted by a wireless transmitter/receiver (T-x/R-x) module working with radio frequency technology. Parallel digital bits are generated using NI USB 6251 card working in LabVIEW platform and sent to transmission module to transmit the digital data to the receiver end. The transmitter/receiver module developed is properly interfaced with the personal computer (PC) and practical phantoms through the ESM and USB based DAQ system respectively. It is observed that the digital bits required for multiplexer operation are sequentially generated by the digital output (D/O) ports of the DAQ card. Parallel to serial and serial to parallel conversion of digital data are suitably done by encoder and decoder ICs. Wireless digital data transmission module successfully transmitted and received the parallel data required for switching the current and voltage electrodes wirelessly. 1 mA, 50 kHz sinusoidal constant current is injected at the phantom boundary using common ground current injection protocol and the boundary potentials developed at the voltage electrodes are measured. Resistivity images of the practical phantoms are reconstructed from boundary data using EIDORS. Boundary data and the resistivity images reconstructed from the surface potentials are studied to assess the wireless digital data transmission system. Boundary data profiles of the practical phantom with different configurations show that the multiplexers are operating in the required sequence for common ground current injection protocol. The voltage peaks obtained at the proper positions in the boundary data profiles proved the sequential operation of multiplexers and successful wireless transmission of digital bits. Reconstructed images and their image parameters proved that the boundary data are successfully acquired by the DAQ system which in turn again indicates a sequential and proper operation of multiplexers as well as the successful wireless transmission of digital bits. Hence the developed RF based wireless digital data transmission module (WDDTM) is found suitable for transmitting digital bits required for electrode switching in wireless EIT data acquisition system. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Surface electrode switching of 16-electrode wireless EIT is studied using a Radio Frequency (RF) based digital data transmission technique operating with 8 channel encoder/decoder ICs. An electrode switching module is developed the analog multiplexers and switched with 8-bit parallel digital data transferred by transmitter/receiver module developed with radio frequency technology. 8-bit parallel digital data collected from the receiver module are converted to 16-bit digital data by using binary adder circuits and then used for switching the electrodes in opposite current injection protocol. 8-bit parallel digital data are generated using NI USB 6251 DAQ card in LabVIEW software and sent to the transmission module which transmits the digital data bits to the receiver end. Receiver module supplies the parallel digital bits to the binary adder circuits and adder circuit outputs are fed to the multiplexers of the electrode switching module for surface electrode switching. 1 mA, 50 kHz sinusoidal constant current is injected at the phantom boundary using opposite current injection protocol. The boundary potentials developed at the voltage electrodes are measured and studied to assess the wireless data transmission.
Resumo:
实验报道采用我国自行设计的大模场掺镱双包层光纤,利用简单声光调Q装置,成功实现调Q运转;在1-50kHz调制频率下获得了百纳秒的调Q脉冲,其输出光束质量因子大约为2。当重复频率为1kHz时,获得了脉冲宽度为132ns,能量0.93mJ。同时实验中观察到的调Q脉冲常出现一点锁模现象,针对这一现象进行了讨论。
Resumo:
A novel acousto-optic switch operation by a simple laser-diode pumped acousto-optic, Q-switched, ytterbium-doped, double-clad fiber laser is reported. Stable compressed Q-switched sub-40 ns pulses with a beam quality factor (M-2 = 2) are achieved at the repetition rate of 1-50 kHz. Q-switched pulses of similar to 20 mu J pulse energy and 35 as pulse width are obtained at the repetition rate of 50 kHz. Finally, a reasonable explanation of the novel Q-switched operation is presented. (c) 2007 Optical Society of America.