997 resultados para 48-hour Pad Test


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Stress urinary incontinence (SUI) is defined as "involuntary loss of urine" due to several processes that alter the ability of the bladder to hold urine properly, regarded as a social and hygienic problem that adversely affects quality of life. In postmenopausal women, IU is associated with atrophy and weakness of the pelvic floor muscles. The objective this study was investigate, using the onehour pad test, stress urinary leakage (SUI), evaluate and compare their results in postmenopausal and premenopausal women. The survey was characterized as a cross-sectional study. The study consisted of 60 postmenopausal women were divided into GIU - consisting of 34 volunteers complaining of involuntary loss of urine during stress - and GSIU - consisting of 26 volunteers without complaints of loss of urine during stress, and 15 women, during the premenopausal (GPM), and ovulatory with normal menstrual cycle. All volunteers were evaluated clinically, subjected to one-hour pad test, after the biochemical evaluation of blood and sex hormones. Statistical analysis was performed by descriptive analysis, ANOVA, Turkey´s post-test and Pearson correlation. The results showed that 100% of postmenopausal patients had involuntary loss of urine during one hour pad test (GIU: 4.0 g; GSIU: 4.5 g). GPM remained continent after an hour pad test (GPM: 0.4 g). In addition, Pearson showed a strong correlation between urine loss with time since menopause (r = 0.8, p <0.01) and body mass index - BMI (r = 0.7; p = 0.01). These data suggest that the one-hour pad test is a useful test to assess and quantify urinary leakage, including those volunteers who had no previous complaint of SUI

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although there is a high prevalence of leaking urine among Australian women, there are currently no standardized procedures for screening patients for incontinence in the primary care setting (known in Australia as general practice). In response to this, an incontinence screening questionnaire (ISQ) was developed and evaluated for use in general practice. Eighty-nine women completed an original compilation of 33 items that asked about situations associated with leaking urine, avoidance of leakage, and concern about leakage. Each item was assessed according to its acceptability for the population of female general practice patients, discriminative value, and test-retest reliability. These patients also underwent an objective test of incontinence, the 48-hour pad test, so that the screening items could be validated against an objective classification of incontinence. The study included women who had bladder control problems and those who did not. Eight items on the ISQ were shown to be acceptable to patients, discriminative, reliable, and valid indicators of objective incontinence. Five items were capable of predicting almost 70% of patients who showed objective leakage of urine and misclassified fewer than 15% of these patients. Those five items were selected for inclusion in the (refined) ISQ. (C) 2000 Wiley-Liss, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: correlacionar as queixas de incontinência urinária de esforço e os resultados da aplicação do pad test de uma hora em mulheres na pré e pós-menopausa. MÉTODOS: estudo transversal, composto por 60 voluntárias na pós-menopausa, divididas em dois grupos: um com 34 mulheres com queixa de perda involuntária de urina aos esforços, outro com 26 mulheres sem queixas de perda de urina aos esforços. Há também a presença de um Grupo Controle composto por 15 mulheres na pré-menopausa, com ciclo menstrual normal e sem queixas urinárias. Todas as mulheres foram avaliadas quanto à clínica e laboratorialmente, e submetidas ao pad test por uma hora. A paciente foi considerada incontinente quando o peso do absorvente após o teste foi maior do que 1 g. Os resultados obtidos foram submetidos à estatística descritiva, ao teste paramétrico ANOVA, ao pós-teste de Turkey e à correlação de Pearson. RESULTADOS: todas as mulheres na pós-menopausa apresentaram incontinência urinária de esforço durante o pad test, tanto as que referiram perda urinária (4 g), como as sem perda urinária prévia (3,5 g). Nessas mulheres, observou-se uma forte correlação das perdas de urina com o tempo de menopausa (r=0,8; p<0,01) e com o índice de massa corpórea (IMC) (r=0,7; p= 0,01). As mulheres na pré-menopausa mantiveram-se continentes durante o pad test (0,4 g). CONCLUSÕES: os resultados obtidos com a aplicação do pad test de uma hora mostraram que todas as mulheres na pós-menopausa apresentavam incontinência urinária de esforço, inclusive aquelas que não apresentavam queixa de perda de urina aos esforços. Essa perda de urina correlaciona-se com o tempo de menopausa e com o IMC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Although galactose is an important component in human lactose, there are few reports of its role in the newborn metabolism. Objective: To determine the relationship of blood galactose and glucose levels in mothers, cord blood, and breast-fed full-term newborn infants. Methods: Maternal and cord vein blood samples were obtained from 27 pregnant women at delivery, and from their breastfed, full-term newborns 48 h later. Galactose and glucose were determined by HPLC. Statistical analysis used ANOVA and Pearson correlation with p < 0.05. Results: Maternal galactose concentrations (0.08 +/- 0.03 mmol/l) were similar to cord blood galactose (0.07 +/- 0.03 mmol/l; p = 0.129). However, newborn blood galactose (0.05 +/- 0.02 mmol/l) was significantly lower than both cord (p = 0.042) and maternal blood (p = 0.002). Maternal blood glucose levels (4.72 +/- 0.86 mmol/l) were higher than cord blood (3.98 +/- 0.57 mmol/l; p < 0.001), and cord blood concentrations were higher than newborn blood levels (3.00 +/- 0.56 mmol/l; p < 0.001); all values expressed as mean +/- SD. Significant correlation was only seen between maternal and cord blood galactose levels (r = 0.67; p < 0.001) and glucose levels (r = 0.38; p = 0.047). Conclusion: the association and similarity between maternal and cord blood galactose levels suggest that the fetus is dependent on maternal galactose. In contrast, the lower galactose levels in newborn infants and a lack of association between both suggest self-regulation and a dependence on galactose ingestion. Copyright (c) 2007 S. Karger AG, Basel.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The biological and physical processes contributing to planktonic thin layer dynamics were examined in a multidisciplinary study conducted in East Sound, Washington, USA between June 10 and June 25, 1998. The temporal and spatial scales characteristic of thin layers were determined using a nested sampling strategy utilizing 4 major types of platforms: (1) an array of 3 moored acoustical instrument packages and 2 moored optical instrument packages that recorded distributions and intensities of thin layers; (2) additional stationary instrumentation deployed outside the array comprised of meteorological stations, wave-tide gauges, and thermistor chains; (3) a research vessel anchored 150 m outside the western edge of the array; (4) 2 mobile vessels performing basin-wide surveys to define the spatial extent of thin layers and the physical hydrography of the Sound. We observed numerous occurrences of thin layers that contained locally enhanced concentrations of material; many of the layers persisted for intervals of several hours to a few days. More than one persistent thin layer may be present at any one time, and these spatially distinct thin layers often contain distinct plankton assemblages. The results suggest that the species or populations comprising each distinct thin layer have responded to different sets of biological and/or physical processes. The existence and persistence of planktonic thin layers generates extensive biological heterogeneity in the water column and may be important in maintaining species diversity and overall community structure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The impact of pelvic floor muscle training on the recovery of urinary continence after radical prostatectomy is still controversial. We tested the effectiveness of biofeedback-pelvic floor muscle training in improving urinary incontinence in the 12 months following radical prostatectomy. Materials and Methods: A total of 73 patients who underwent radical prostatectomy were randomized to a treatment group (36) receiving biofeedback-pelvic floor muscle training once a week for 3 months as well as home exercises or a control group (37). Patients were evaluated 1, 3, 6 and 12 months postoperatively. Continence was defined as the use of 1 pad or less daily and incontinence severity was measured by the 24-hour pad test. Incontinence symptoms and quality of life were assessed with the International Continence Society male Short Form questionnaire and the Incontinence Impact Questionnaire. Pelvic floor muscle strength was evaluated with the Oxford score. Results: A total of 54 patients (26 pelvic floor muscle training and 28 controls) completed the trial. Duration of incontinence was shorter in the treatment group. At postoperative month 12, 25 (96.15%) patients in the treatment group and 21 (75.0%) in the control group were continent (p = 0.028). The absolute risk reduction was 21.2% (95% CI 3.45-38.81) and the relative risk of recovering continence was 1.28 (95% CI 1.02-1.69). The number needed to treat was 5 (95% CI 2.6-28.6). Overall there were significant changes in both groups in terms of incontinence symptoms, lower urinary tract symptoms, quality of life and pelvic floor muscle strength (p <0.0001). Conclusions: Early biofeedback-pelvic floor muscle training not only hastens the recovery of urinary continence after radical prostatectomy but allows for significant improvements in the severity of incontinence, voiding symptoms and pelvic floor muscle strength 12 months postoperatively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To assess the application of aponeurotic sling by a modified technique with direct visualization of needles in patients with stress urinary incontinence. Methods: we applied the Kings Health Questionnaire (KHQ) for quality of life, gynecological examination, urinalysis I and urine culture approximately seven days prior to the urodynamic study (UDS) and the one-hour PAD test in patients undergoing making aponeurotic sling with its passing through the retropubic route with direct visualization of the needle, PAD test and King's Helth Questionnaire before and after surgery. Results: The mean age was 50.6 years, BMI of 28 and Leak Pressure (LP) 58,5cm H2O; 89% were Caucasian. Forty-six of them were monitored for three and six months, 43 for 12 months. The objective cure rate at 12 months postoperatively was approximately 93.5%. In evaluating quality of life, we observed a significant improvement in 12 months postoperatively compared with the preoperative period. There was no no urethral/bladder injury. As adverse results, we had one persistent urinary retention (2.3%), who was submitted to urethrolysis, currently without incontinence. Conclusion: The proposed procedure is safe as for the risk of bladder or urethral injuries, promoting significant improvement in quality of life and objective cure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It is well accepted that the hippocampus (HIP) is important for spatial and contextual memories, however, it is not clear if the entorhinal cortex (EC), the main input/output structure for the hippocampus, is also necessary for memory storage. Damage to the EC in humans results in memory deficits. However, animal studies report conflicting results on whether the EC is necessary for spatial and contextual memory. Memory consolidation requires gene expression and protein synthesis, mediated by signaling cascades and transcription factors. Extracellular-signal regulated kinase (ERK) cascade activity is necessary for long-term memory in several tasks, including those that test spatial and contextual memory. In this work, we explore the role of ERK-mediated plasticity in the EC on spatial and contextual memory. ^ To evaluate this role, post-training infusions of reversible pharmacological inhibitors specific for the ERK cascade that do not affect normal neuronal activity were targeted directly to the EC of awake, behaving animals. This technique provides spatial and temporal control over the inhibition of the ERK cascade without affecting performance during training or testing. Using the Morris water maze to study spatial memory, we found that ERK inhibition in the EC resulted in long-term memory deficits consistent with a loss of spatial strategy information. When animals were allowed to learn and consolidate a spatial strategy for solving the task prior to training and ERK inhibition, the deficit was alleviated. To study contextual memory, we trained animals in a cued fear-conditioning task and saw an increase in the activation of ERK in the EC 90 minutes following training. ERK inhibition in the EC over this time point, but not at an earlier time point, resulted in increased freezing to the context, but not to the tone, during a 48-hour retention test. In addition, animals froze maximally at the time the shock was given during training; similar to naïve animals receiving additional training, suggesting that ERK-mediated plasticity in the EC normally suppresses the temporal nature of the freezing response. These findings demonstrate that plasticity in the EC is necessary for both spatial and contextual memory, specifically in the retention of behavioral strategies. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Four groups of horses of Brasileiro de Hipismo bred were submitted to fasting for 24 and 48 hours in order to study the absorption capacity of the small intestine. Two groups were fed with coast cross grass (Cynodon dactylon) and the other two groups with coast cross pasture and grains. At the end of the fasting periods, the groups received 1g of glucose/kg of body weight in a 20% solution through a nasogastric tube. Blood samples were collected immediately before and 70, 60, 120, 180, 240, 300, and 360 minutes after glucose administration. Glycemia was determined by the orthotoluidine method and insulin by radioimmunoassay. The animals which received grains showed larger increase in glycemia and insulinemia than those maintained on pasture regimen alone. The 48-hour fasting period induced higher glycemia and insulinemia levels than those observed after 24-hour fasting.