9 resultados para 46399


Relevância:

20.00% 20.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Algorithms for adaptive mesh refinement using a residual error estimator are proposed for fluid flow problems in a finite volume framework. The residual error estimator, referred to as the R-parameter is used to derive refinement and coarsening criteria for the adaptive algorithms. An adaptive strategy based on the R-parameter is proposed for continuous flows, while a hybrid adaptive algorithm employing a combination of error indicators and the R-parameter is developed for discontinuous flows. Numerical experiments for inviscid and viscous flows on different grid topologies demonstrate the effectiveness of the proposed algorithms on arbitrary polygonal grids.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

采用水平板淀粉胶电泳技术分析了云南马关保种无角山羊的血液蛋白多态性。对36个个体45个基因座位的分析得出:Esd、Pep-B、Lap、Akp、Ces-1、Ces-2共6个座位出现多态性,且Esd~(A)、Pep-B~(A)、Lap~(A)、Akp~(B)、Ces-1~(A)、Ces-2~(A)的基因频率较高。多态座位百分率P=0.133,平均杂合度H=0.04863。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Resumen de la autora

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Resumen tomado de la web del Departamento de Educación

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE Images from computed tomography (CT), combined with navigation systems, improve the outcomes of local thermal therapies that are dependent on accurate probe placement. Although the usage of CT is desired, its availability for time-consuming radiological interventions is limited. Alternatively, three-dimensional images from C-arm cone-beam CT (CBCT) can be used. The goal of this study was to evaluate the accuracy of navigated CBCT-guided needle punctures, controlled with CT scans. METHODS Five series of five navigated punctures were performed on a nonrigid phantom using a liver specific navigation system and CBCT volumetric dataset for planning and navigation. To mimic targets, five titanium screws were fixed to the phantom. Target positioning accuracy (TPECBCT) was computed from control CT scans and divided into lateral and longitudinal components. Additionally, CBCT-CT guidance accuracy was deducted by performing CBCT-to-CT image coregistration and measuring TPECBCT-CT from fused datasets. Image coregistration was evaluated using fiducial registration error (FRECBCT-CT) and target registration error (TRECBCT-CT). RESULTS Positioning accuracies in lateral directions pertaining to CBCT (TPECBCT = 2.1 ± 1.0 mm) were found to be better to those achieved from previous study using CT (TPECT = 2.3 ± 1.3 mm). Image coregistration error was 0.3 ± 0.1 mm, resulting in an average TRE of 2.1 ± 0.7 mm (N = 5 targets) and average Euclidean TPECBCT-CT of 3.1 ± 1.3 mm. CONCLUSIONS Stereotactic needle punctures might be planned and performed on volumetric CBCT images and controlled with multidetector CT with positioning accuracy higher or similar to those performed using CT scanners.

Relevância:

10.00% 10.00%

Publicador: