974 resultados para 3D surfaces


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper addresses the estimation of object boundaries from a set of 3D points. An extension of the constrained clustering algorithm developed by Abrantes and Marques in the context of edge linking is presented. The object surface is approximated using rectangular meshes and simplex nets. Centroid-based forces are used for attracting the model nodes towards the data, using competitive learning methods. It is shown that competitive learning improves the model performance in the presence of concavities and allows to discriminate close surfaces. The proposed model is evaluated using synthetic data and medical images (MRI and ultrasound images).

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The design of pre-contoured fracture fixation implants (plates and nails) that correctly fit the anatomy of a patient utilises 3D models of long bones with accurate geometric representation. 3D data is usually available from computed tomography (CT) scans of human cadavers that generally represent the above 60 year old age group. Thus, despite the fact that half of the seriously injured population comes from the 30 year age group and below, virtually no data exists from these younger age groups to inform the design of implants that optimally fit patients from these groups. Hence, relevant bone data from these age groups is required. The current gold standard for acquiring such data–CT–involves ionising radiation and cannot be used to scan healthy human volunteers. Magnetic resonance imaging (MRI) has been shown to be a potential alternative in the previous studies conducted using small bones (tarsal bones) and parts of the long bones. However, in order to use MRI effectively for 3D reconstruction of human long bones, further validations using long bones and appropriate reference standards are required. Accurate reconstruction of 3D models from CT or MRI data sets requires an accurate image segmentation method. Currently available sophisticated segmentation methods involve complex programming and mathematics that researchers are not trained to perform. Therefore, an accurate but relatively simple segmentation method is required for segmentation of CT and MRI data. Furthermore, some of the limitations of 1.5T MRI such as very long scanning times and poor contrast in articular regions can potentially be reduced by using higher field 3T MRI imaging. However, a quantification of the signal to noise ratio (SNR) gain at the bone - soft tissue interface should be performed; this is not reported in the literature. As MRI scanning of long bones has very long scanning times, the acquired images are more prone to motion artefacts due to random movements of the subject‟s limbs. One of the artefacts observed is the step artefact that is believed to occur from the random movements of the volunteer during a scan. This needs to be corrected before the models can be used for implant design. As the first aim, this study investigated two segmentation methods: intensity thresholding and Canny edge detection as accurate but simple segmentation methods for segmentation of MRI and CT data. The second aim was to investigate the usability of MRI as a radiation free imaging alternative to CT for reconstruction of 3D models of long bones. The third aim was to use 3T MRI to improve the poor contrast in articular regions and long scanning times of current MRI. The fourth and final aim was to minimise the step artefact using 3D modelling techniques. The segmentation methods were investigated using CT scans of five ovine femora. The single level thresholding was performed using a visually selected threshold level to segment the complete femur. For multilevel thresholding, multiple threshold levels calculated from the threshold selection method were used for the proximal, diaphyseal and distal regions of the femur. Canny edge detection was used by delineating the outer and inner contour of 2D images and then combining them to generate the 3D model. Models generated from these methods were compared to the reference standard generated using the mechanical contact scans of the denuded bone. The second aim was achieved using CT and MRI scans of five ovine femora and segmenting them using the multilevel threshold method. A surface geometric comparison was conducted between CT based, MRI based and reference models. To quantitatively compare the 1.5T images to the 3T MRI images, the right lower limbs of five healthy volunteers were scanned using scanners from the same manufacturer. The images obtained using the identical protocols were compared by means of SNR and contrast to noise ratio (CNR) of muscle, bone marrow and bone. In order to correct the step artefact in the final 3D models, the step was simulated in five ovine femora scanned with a 3T MRI scanner. The step was corrected using the iterative closest point (ICP) algorithm based aligning method. The present study demonstrated that the multi-threshold approach in combination with the threshold selection method can generate 3D models from long bones with an average deviation of 0.18 mm. The same was 0.24 mm of the single threshold method. There was a significant statistical difference between the accuracy of models generated by the two methods. In comparison, the Canny edge detection method generated average deviation of 0.20 mm. MRI based models exhibited 0.23 mm average deviation in comparison to the 0.18 mm average deviation of CT based models. The differences were not statistically significant. 3T MRI improved the contrast in the bone–muscle interfaces of most anatomical regions of femora and tibiae, potentially improving the inaccuracies conferred by poor contrast of the articular regions. Using the robust ICP algorithm to align the 3D surfaces, the step artefact that occurred by the volunteer moving the leg was corrected, generating errors of 0.32 ± 0.02 mm when compared with the reference standard. The study concludes that magnetic resonance imaging, together with simple multilevel thresholding segmentation, is able to produce 3D models of long bones with accurate geometric representations. The method is, therefore, a potential alternative to the current gold standard CT imaging.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Feature track matrix factorization based methods have been attractive solutions to the Structure-front-motion (Sfnl) problem. Group motion of the feature points is analyzed to get the 3D information. It is well known that the factorization formulations give rise to rank deficient system of equations. Even when enough constraints exist, the extracted models are sparse due the unavailability of pixel level tracks. Pixel level tracking of 3D surfaces is a difficult problem, particularly when the surface has very little texture as in a human face. Only sparsely located feature points can be tracked and tracking error arc inevitable along rotating lose texture surfaces. However, the 3D models of an object class lie in a subspace of the set of all possible 3D models. We propose a novel solution to the Structure-from-motion problem which utilizes the high-resolution 3D obtained from range scanner to compute a basis for this desired subspace. Adding subspace constraints during factorization also facilitates removal of tracking noise which causes distortions outside the subspace. We demonstrate the effectiveness of our formulation by extracting dense 3D structure of a human face and comparing it with a well known Structure-front-motion algorithm due to Brand.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Ao longo dos últimos anos, os scanners 3D têm tido uma utilização crescente nas mais variadas áreas. Desde a Medicina à Arqueologia, passando pelos vários tipos de indústria, ´e possível identificar aplicações destes sistemas. Essa crescente utilização deve-se, entre vários factores, ao aumento dos recursos computacionais, à simplicidade e `a diversidade das técnicas existentes, e `as vantagens dos scanners 3D comparativamente com outros sistemas. Estas vantagens são evidentes em áreas como a Medicina Forense, onde a fotografia, tradicionalmente utilizada para documentar objectos e provas, reduz a informação adquirida a duas dimensões. Apesar das vantagens associadas aos scanners 3D, um factor negativo é o preço elevado. No âmbito deste trabalho pretendeu-se desenvolver um scanner 3D de luz estruturada económico e eficaz, e um conjunto de algoritmos para o controlo do scanner, para a reconstrução de superfícies de estruturas analisadas, e para a validação dos resultados obtidos. O scanner 3D implementado ´e constituído por uma câmara e por um projector de vídeo ”off-the-shelf”, e por uma plataforma rotativa desenvolvida neste trabalho. A função da plataforma rotativa consiste em automatizar o scanner de modo a diminuir a interação dos utilizadores. Os algoritmos foram desenvolvidos recorrendo a pacotes de software open-source e a ferramentas gratuitas. O scanner 3D foi utilizado para adquirir informação 3D de um crânio, e o algoritmo para reconstrução de superfícies permitiu obter superfícies virtuais do crânio. Através do algoritmo de validação, as superfícies obtidas foram comparadas com uma superfície do mesmo crânio, obtida por tomografia computorizada (TC). O algoritmo de validação forneceu um mapa de distâncias entre regiões correspondentes nas duas superfícies, que permitiu quantificar a qualidade das superfícies obtidas. Com base no trabalho desenvolvido e nos resultados obtidos, é possível afirmar que foi criada uma base funcional para o varrimento de superfícies 3D de estruturas, apta para desenvolvimento futuro, mostrando que é possível obter alternativas aos métodos comerciais usando poucos recursos financeiros.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper addresses the problem of obtaining 3d detailed reconstructions of human faces in real-time and with inexpensive hardware. We present an algorithm based on a monocular multi-spectral photometric-stereo setup. This system is known to capture high-detailed deforming 3d surfaces at high frame rates and without having to use any expensive hardware or synchronized light stage. However, the main challenge of such a setup is the calibration stage, which depends on the lights setup and how they interact with the specific material being captured, in this case, human faces. For this purpose we develop a self-calibration technique where the person being captured is asked to perform a rigid motion in front of the camera, maintaining a neutral expression. Rigidity constrains are then used to compute the head's motion with a structure-from-motion algorithm. Once the motion is obtained, a multi-view stereo algorithm reconstructs a coarse 3d model of the face. This coarse model is then used to estimate the lighting parameters with a stratified approach: In the first step we use a RANSAC search to identify purely diffuse points on the face and to simultaneously estimate this diffuse reflectance model. In the second step we apply non-linear optimization to fit a non-Lambertian reflectance model to the outliers of the previous step. The calibration procedure is validated with synthetic and real data.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Photometric Stereo is a powerful image based 3D reconstruction technique that has recently been used to obtain very high quality reconstructions. However, in its classic form, Photometric Stereo suffers from two main limitations: Firstly, one needs to obtain images of the 3D scene under multiple different illuminations. As a result the 3D scene needs to remain static during illumination changes, which prohibits the reconstruction of deforming objects. Secondly, the images obtained must be from a single viewpoint. This leads to depth-map based 2.5 reconstructions, instead of full 3D surfaces. The aim of this Chapter is to show how these limitations can be alleviated, leading to the derivation of two practical 3D acquisition systems: The first one, based on the powerful Coloured Light Photometric Stereo method can be used to reconstruct moving objects such as cloth or human faces. The second, permits the complete 3D reconstruction of challenging objects such as porcelain vases. In addition to algorithmic details, the Chapter pays attention to practical issues such as setup calibration, detection and correction of self and cast shadows. We provide several evaluation experiments as well as reconstruction results. © 2010 Springer-Verlag Berlin Heidelberg.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Los protocolos de medición antropométrica se caracterizan por la profusión de medidas discretas o localizadas, en un intento para caracterizar completamente la forma corporal del sujeto -- Dichos protocolos se utilizan intensivamente en campos como medicina deportiva, forense y/o reconstructiva, diseño de prótesis, ergonomía, en la confección de prendas, accesorios, etc -- Con el avance de algoritmos de recuperación de formas a partir de muestreos (digitalizaciones) la caracterización antropométrica se ha alterado significativamente -- El articulo presente muestra el proceso de caracterización digital de forma corpórea, incluyendo los protocolos de medición sobre el sujeto, el ambiente computacional - DigitLAB- (desarrollado en el CII-CAD-CAM-CG de la Universidad EAFIT) para recuperación de superficies, hasta los modelos geométricos finales -- Se presentan comparaciones de los resultados obtenidos con DigitLAB y con paquetes comerciales de recuperación de forma 3D -- Los resultados de DigitLAB resultan superiores, debido principalmente al hecho de que este toma ventaja de los patrones de las digitalizaciones (planares de contacto, por rejilla de pixels - range images -, etc.) y provee módulos de tratamiento geométrico - estadístico de los datos para poder aplicar efectivamente los algoritmos de recuperación de forma -- Se presenta un caso de estudio dirigido a la industria de la confección, y otros efectuados sobre conjuntos de prueba comunes en el ámbito científico para la homologación de algoritmos

Relevância:

60.00% 60.00%

Publicador:

Resumo:

When we look at a scene, how do we consciously see surfaces infused with lightness and color at the correct depths? Random Dot Stereograms (RDS) probe how binocular disparity between the two eyes can generate such conscious surface percepts. Dense RDS do so despite the fact that they include multiple false binocular matches. Sparse stereograms do so even across large contrast-free regions with no binocular matches. Stereograms that define occluding and occluded surfaces lead to surface percepts wherein partially occluded textured surfaces are completed behind occluding textured surfaces at a spatial scale much larger than that of the texture elements themselves. Earlier models suggest how the brain detects binocular disparity, but not how RDS generate conscious percepts of 3D surfaces. A neural model predicts how the layered circuits of visual cortex generate these 3D surface percepts using interactions between visual boundary and surface representations that obey complementary computational rules.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La thérapie de resynchronisation cardiaque (CRT) est un traitement qui diminue la mortalité et améliore la qualité de vie des patients atteints d’insuffisance cardiaque et présentant un dyssynchronisme de la contraction ventriculaire gauche. Malgré le succès de cette thérapie, plus de 30% des patients ne présentent pas l’amélioration désirée. Plusieurs études portant sur le synchronisme électrique ou mécanique de la contraction ont été effectuées mais peu d’entres elles se sont attardées sur le couplage électromécanique à l'échelle macroscopique. Ce projet a comme objectif d’observer le comportement électromécanique des ventricules canins en présence d’un resynchronisateur cardiaque. Un logiciel a été développé pour permettre l’analyse des informations provenant de la cartographie endocardique sans contact et de la ventriculographie isotopique tomographique chez 12 sujets canins insuffisants. Pour observer la réponse mécanique suite à l’activation électrique, nous avons premièrement recalé les surfaces issues des 2 modalités. Ensuite, nous avons défini les limites du cycle cardiaque, analysé les signaux électriques et les courbes de déplacement de la paroi endocardique. Le début de la contraction est défini par un déplacement radial de 10% vers le centre du ventricule. Les résultats démontrent que la durée d’activation du ventricule gauche et la largeur du QRS augmentent en présence d’une stimulation externe et que les délais électromécaniques sont indépendants dans les modes de stimulation étudiés (sinusal, LVbasal, RVapex ou BIV) avec une moyenne de 84,56±7,19 ms. Finalement, nous avons noté que la stimulation basolatérale procure une fonction cardiaque optimale malgré une durée prolongée du QRS.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The registration of full 3-D models is an important task in computer vision. Range finders only reconstruct a partial view of the object. Many authors have proposed several techniques to register 3D surfaces from multiple views in which there are basically two aspects to consider. First, poor registration in which some sort of correspondences are established. Second, accurate registration in order to obtain a better solution. A survey of the most common techniques is presented and includes experimental results of some of them

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work is presented a new method for sensor deployment on 3D surfaces. The method was structured on different steps. The first one aimed discretizes the relief of interest with Delaunay algorithm. The tetrahedra and relative values (spatial coordinates of each vertex and faces) were input to construction of 3D Voronoi diagram. Each circumcenter was calculated as a candidate position for a sensor node: the corresponding circular coverage area was calculated based on a radius r. The r value can be adjusted to simulate different kinds of sensors. The Dijkstra algorithm and a selection method were applied to eliminate candidate positions with overlapped coverage areas or beyond of surface of interest. Performance evaluations measures were defined using coverage area and communication as criteria. The results were relevant, once the mean coverage rate achieved on three different surfaces were among 91% and 100%.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The validation of Computed Tomography (CT) based 3D models takes an integral part in studies involving 3D models of bones. This is of particular importance when such models are used for Finite Element studies. The validation of 3D models typically involves the generation of a reference model representing the bones outer surface. Several different devices have been utilised for digitising a bone’s outer surface such as mechanical 3D digitising arms, mechanical 3D contact scanners, electro-magnetic tracking devices and 3D laser scanners. However, none of these devices is capable of digitising a bone’s internal surfaces, such as the medullary canal of a long bone. Therefore, this study investigated the use of a 3D contact scanner, in conjunction with a microCT scanner, for generating a reference standard for validating the internal and external surfaces of a CT based 3D model of an ovine femur. One fresh ovine limb was scanned using a clinical CT scanner (Phillips, Brilliance 64) with a pixel size of 0.4 mm2 and slice spacing of 0.5 mm. Then the limb was dissected to obtain the soft tissue free bone while care was taken to protect the bone’s surface. A desktop mechanical 3D contact scanner (Roland DG Corporation, MDX 20, Japan) was used to digitise the surface of the denuded bone. The scanner was used with the resolution of 0.3 × 0.3 × 0.025 mm. The digitised surfaces were reconstructed into a 3D model using reverse engineering techniques in Rapidform (Inus Technology, Korea). After digitisation, the distal and proximal parts of the bone were removed such that the shaft could be scanned with a microCT (µCT40, Scanco Medical, Switzerland) scanner. The shaft, with the bone marrow removed, was immersed in water and scanned with a voxel size of 0.03 mm3. The bone contours were extracted from the image data utilising the Canny edge filter in Matlab (The Mathswork).. The extracted bone contours were reconstructed into 3D models using Amira 5.1 (Visage Imaging, Germany). The 3D models of the bone’s outer surface reconstructed from CT and microCT data were compared against the 3D model generated using the contact scanner. The 3D model of the inner canal reconstructed from the microCT data was compared against the 3D models reconstructed from the clinical CT scanner data. The disparity between the surface geometries of two models was calculated in Rapidform and recorded as average distance with standard deviation. The comparison of the 3D model of the whole bone generated from the clinical CT data with the reference model generated a mean error of 0.19±0.16 mm while the shaft was more accurate(0.08±0.06 mm) than the proximal (0.26±0.18 mm) and distal (0.22±0.16 mm) parts. The comparison between the outer 3D model generated from the microCT data and the contact scanner model generated a mean error of 0.10±0.03 mm indicating that the microCT generated models are sufficiently accurate for validation of 3D models generated from other methods. The comparison of the inner models generated from microCT data with that of clinical CT data generated an error of 0.09±0.07 mm Utilising a mechanical contact scanner in conjunction with a microCT scanner enabled to validate the outer surface of a CT based 3D model of an ovine femur as well as the surface of the model’s medullary canal.