996 resultados para 3D printer


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The process of making replicas of heritage has traditionally been developed by public agencies, corporations and museums and is not commonly used in schools. Currently there are technologies that allow creating cheap replicas. The new 3D reconstruction software, based on photographs and low cost 3D printers allow to make replicas at a cost much lower than traditional. This article describes the process of creating replicas of the sculpture Goslar Warrior of artist Henry Moore, located in Santa Cruz de Tenerife. To make this process, first, a digital model have been created using Autodesk Recap 360, Autodesk 123D Catch and Autodesk Meshmixer MarkerBot MakerWare applications. Physical replication, has been reproduced in polylactic acid (PLA) by MakerBot Replicator 2 3D printer. In addition, a cost analysis using, in one hand, the printer mentioned, and in the other hand, 3D printing services both online and local, is included. Finally, there has been a specific action with 141 students and 12 high school teachers, who filled a questionnary about the use of sculptural replicas in education.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

[EU]Hiru dimentsioko inprimaketa etorkizun handiko teknologia bezala azaltzen zaigu gaur egun. Esate baterako, biomedikuntza arloan aukera berritzaileak ekar ditzake, baina baita hezkuntza, heziketa eta ikerketa munduetan ere. Teknologia berri honen abantailarik nagusiena prototipatze azkarrean datza, eta honi esker, mikro- eta makro- egitura definituak dituzten objektuak diseinatu eta fabrikatu daitezke modu lehiakorrean. Lan honen helburua 3D inprimagailu baten bitartez inprimaturiko polimero biobateragarri eta biodegradagarrietan oinarrituriko ereduen garapen eta fabrikazioan datza. Hala ere, lehenik eta behin, lehengaiak bai fisikoki eta bai termikoki karakterizatu behar dira, ondoren, 3D inprimagailuaren parametroen arteko erlazioa ezarri, eta azkenik, produktu finalaren egitura propietateak eta kalitatea aztertu. Aipaturiko lana aurrera eramateko erabili den materiala polilaktida (PLA) izan da, zeinen erabilera oso zabaldua dagoen medikuntza arloan inplante (torloju, iltze, plaka eta abar) moduan eta ehun ingeniaritzaren munduan.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Humans can perceive three dimension, our world is three dimensional and it is becoming increasingly digital too. We have the need to capture and preserve our existence in digital means perhaps due to our own mortality. We have also the need to reproduce objects or create small identical objects to prototype, test or study them. Some objects have been lost through time and are only accessible through old photographs. With robust model generation from photographs we can use one of the biggest human data sets and reproduce real world objects digitally and physically with printers. What is the current state of development in three dimensional reconstruction through photographs both in the commercial world and in the open source world? And what tools are available for a developer to build his own reconstruction software? To answer these questions several pieces of software were tested, from full commercial software packages to open source small projects, including libraries aimed at computer vision. To bring to the real world the 3D models a 3D printer was built, tested and analyzed, its problems and weaknesses evaluated. Lastly using a computer vision library a small software with limited capabilities was developed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Pós-graduação em Educação para a Ciência - FC

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Until few years ago, 3D modelling was a topic confined into a professional environment. Nowadays technological innovations, the 3D printer among all, have attracted novice users to this application field. This sudden breakthrough was not supported by adequate software solutions. The 3D editing tools currently available do not assist the non-expert user during the various stages of generation, interaction and manipulation of 3D virtual models. This is mainly due to the current paradigm that is largely supported by two-dimensional input/output devices and strongly affected by obvious geometrical constraints. We have identified three main phases that characterize the creation and management of 3D virtual models. We investigated these directions evaluating and simplifying the classic editing techniques in order to propose more natural and intuitive tools in a pure 3D modelling environment. In particular, we focused on freehand sketch-based modelling to create 3D virtual models, interaction and navigation in a 3D modelling environment and advanced editing tools for free-form deformation and objects composition. To pursuing these goals we wondered how new gesture-based interaction technologies can be successfully employed in a 3D modelling environments, how we could improve the depth perception and the interaction in 3D environments and which operations could be developed to simplify the classical virtual models editing paradigm. Our main aims were to propose a set of solutions with which a common user can realize an idea in a 3D virtual model, drawing in the air just as he would on paper. Moreover, we tried to use gestures and mid-air movements to explore and interact in 3D virtual environment, and we studied simple and effective 3D form transformations. The work was carried out adopting the discrete representation of the models, thanks to its intuitiveness, but especially because it is full of open challenges.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This thesis work has been carried out at Clarkson University in Potsdam NY, USA and involved the design of a low elongation wing, consisting of parts made by polylactide (PLA) using the fused deposition model (FDM) technology of Rapid Prototyping, then assembled together in a thin aluminum spar. The aim of the research is to evaluate the feasibility of collecting electrical energy by converting mechanical energy from the vibration of the wing flutter. With this aim piezoelectric stripes were glued in the inner part of the wing, as well as on the aluminum spar, as monomorphic configuration. During the phases of the project, particular attention was given to the geometry and the materials used, in order to trigger the flutter for low flow velocity. The CAD software SolidWorks® was used for the design of the wing and then the drawings were sent to the Clarkson machine shop in order to to produce the parts required by the wing assembly. FEM simulations were performed, using software MSC NASTRAN/PATRAN®, to evaluate the stiffness of the whole wing as well as the natural vibration modes of the structure. These data, in a first approximation, were used to predict the flutter speed. Finally, experimental tests in the Clarkson wind tunnel facility were carried out in order to validate the results obtained from FEM analysis. The power collected by the piezoelectrics under flutter condition was addressed by tuning the resistors downstream the electronic circuit of the piezoelectrics.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

With the increasing use of medical imaging in forensics, as well as the technological advances in rapid prototyping, we suggest combining these techniques to generate displays of forensic findings. We used computed tomography (CT), CT angiography, magnetic resonance imaging (MRI) and surface scanning with photogrammetry in conjunction with segmentation techniques to generate 3D polygon meshes. Based on these data sets, a 3D printer created colored models of the anatomical structures. Using this technique, we could create models of bone fractures, vessels, cardiac infarctions, ruptured organs as well as bitemark wounds. The final models are anatomically accurate, fully colored representations of bones, vessels and soft tissue, and they demonstrate radiologically visible pathologies. The models are more easily understood by laypersons than volume rendering or 2D reconstructions. Therefore, they are suitable for presentations in courtrooms and for educational purposes.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

El objetivo principal del presente Proyecto Fin de Carrera es la construcción , montaje y calibración de una impresora 3D auto replicable modelo Prusa Mendel capaz de trabajar en coordenadas polares, lo cual abre las puertas a la investigación de calidades, tolerancias, resistencias estructurales… de estas piezas en comparación con las fabricadas por impresoras cartesianas. Encontraras una guía de montaje paso a paso, además de un listado de todos los componentes, imprimibles y no imprimibles, que componen la impresora 3D. También se analizan y comparan las opciones a la hora de introducir la electrónica necesaria, extrusor y de los posibles errores y soluciones que se pueden encontrar durante la fabricación de una de estas máquinas. Finalmente dispondrás de una guía de calibración de skeinforce 41,para poder conseguir una impresión de gran calidad. Abstract The main objective of this Thesis is the construction, installation and calibration of a self-replicating 3D printer model Prusa Mendel able to work in polar coordinates, which opens the door to research quality, tolerances, these structural resistance ... parts compared to those manufactured by Cartesian printers. In this project you will find a guide step by step assembly, and a list of all components, and 3D printer components printable and unprintable. We also analyze and compare the options when entering the necessary electronics, extruder and possible errors and solutions that may occur during manufacturing of these machines finally have an installation guide calibration skeinforge 41 to get a high quality print

Relevância:

70.00% 70.00%

Publicador:

Resumo:

La tesi segue il progetto della Delta WASP 3MT, stampante 3D di grandi dimensioni. Il lavoro parte da una analisi del contesto che incontra i temi dell'artigianato digitale e dell'autoproduzione. Successivamente viene fatta una analisi dei requisiti e delle soluzioni tecniche implementabili sulla macchina per soddisfarli. A questa segue una illustrazione degli interventi sulle varie parti della macchina. Infine si espongono brevemente i punti chiave elaborati per la comunicazione della macchina, dal naming alla strategia nei punti vendita.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Este trabalho consistiu no projeto e construção de um veleiro autónomo de pequena escala. No início do trabalho, é feito um estudo acerca dos diferentes tipos de veículos autónomos, dando mais enfase aos veleiros. Em seguida, é iniciado o projeto do casco do veleiro, aplicando conceitos básicos de Arquitetura Naval. A forma do casco é desenhada com recurso ao programa DELFT Ship Free, onde são realizados estudos hidrodinâmicos do mesmo. Posteriormente é retratado a construção do casco projetado, com recurso a materiais compósitos e impressão 3D de componentes do veleiro. São ainda descritos os sensores, controladores, atuadores e programação desenvolvida para o veleiro. É também realizado um estudo sumário da estimativa de consumos e autonomia do sistema. No final, encontram-se os resultados obtidos das provas de mar efetuadas ao veleiro.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

[EU]3D inprimaketa gaur egun, biomedikuntzaren garapenerako aukera ezberdinak ematen dituen teknologia iraultzaile gisa aurkezten da; bai medikuntza arloan formazio eta ikerkuntzarako erreminta gisa, baita dispositibo berrien diseinu eta fabrikaziorako. Bere abantailarik aipagarriena prototipaketa azkarra da. Gainera, teknologia honek barne egitura eta forma ezberdineko objektuak fabrikatzea ahalbidetzen du koste lehiakor batean. Lan honen helburua 3D inprimagailuen bidezko prototipoen fabrikazioan zentratzen da, horretarako lehengai bezala polimero biodegradagarri eta biobateragarria erabiliz. Horrez gain, metodo tradizionalarekin konparatuz teknologia honek izan ditzakeen abantailak ere aztertu nahi dira, ez bakarrik alde ekonomikoari edo denborari begira, baita fabrikatutako objektuen propietateei begira ere. Dena dela, horrekin hasi aurretik ezaugarritze fisiko eta termikoa burutu beharko zaie lehengaiei, 3D inprimagailuaren parametroen aukeraketa egokia egiteko eta parametro horien eta amaierako produktuaren kalitate, egitura eta propietateen artean erlazio egokia ezartzeko. Lan hau aurrera eramateko poli(L-laktida)-rekin (PLLA) egingo da lan, bai ehun ingeniaritzan baita hezurren apurketen finkapenerako dispositiboetan oso erabilia izan den polimeroa.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A prototype Concept Fire Truck was designed using Autodesk Inventor 3D Design Software. Various pictures of old-time and toy fire trucks were utilized for this project. The prototype was printed using a 3D printer to verify that all parts of the truck would fit and work as intended.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dado que es difícil imaginar en el futuro una sociedad moderna donde la energía no juegue un papel fundamental y puesto que numerosos estudios han demostrado que el ritmo actual de consumo de combustibles es insostenible y perjudicial para la vida del planeta, es fundamental concienciar a la humanidad de que un cambio de tendencia no solo es necesario sino que es imperativo. No se trata de erradicar por completo el uso de fuentes de carácter fósil, pues en muchos países es su principal o incluso su única forma de obtener energía, sino de avanzar hacia un equilibrio en la generación, para lo que será vital permitir el desarrollo de energías limpias, aumentar la eficiencia de la tecnología y reducir el consumo. En este contexto se ha decidido construir un rotor eólico de pequeñas dimensiones que servirá como herramienta de estudio para alumnos de ingeniería. Para diseñar la turbina se ha desarrollado un modelo de programación informática que, basado en conceptos aerodinámicos, permite calcular la geometría de las palas en función de unas condiciones iniciales, estimar la potencia del rotor y obtener sus curvas de funcionamiento. Uno de los principales problemas de la tecnología eólica es su alta variabilidad, por ello se ha implementado un sistema de regulación de velocidad; se trata de un mecanismo que actúa sobre la orientación de las palas y permite regular la potencia de un generador eléctrico acoplado al rotor. Los aerogeneradores actuales recurren a este tipo de sistemas para tratar de suavizar los desequilibrios de potencia que puedan producir las ráfagas de viento. Se ha recurrido a un software de diseño asistido por ordenador para dibujar tanto el rotor como el sistema de regulación de velocidad. La mayoría de las piezas del rotor se han fabricado con ayuda de una impresora 3D, otras, las metálicas, se han tallado en aluminio mediante un torno. Aunque el programa informático que realiza los cálculos aerodinámicos devuelve datos teóricos a cerca del comportamiento del rotor, se ha creído necesario probar el molino mediante ensayos de laboratorio a fin de obtener un resultado más realista.Abstract Given that it’s difficult to imagine any modern society in the future where energy does not play a crucial role, and as many studies have shown that the actual rate of fuel consumption is unsustainable and harmful to life on the planet, it is essential to raise mankind’s awareness that a change in the current trend is not only necessary, but is also imperative. It is not a question of completely eradicating the use of fossil fuels, as in many countries they are the main or even the only way of generating energy, but rather working towards a balance in generation. To do so it is vital to encourage the development of clean energies, increase technological efficiency and reduce consumption. In view of this we have decided to build a small scale wind turbine rotor which can be used as a study tool for engineering students. To design the turbine a software programme was developed based on aerodynamic concepts, which allows us to calculate the geometry of the blades depending on certain initial conditions, estimate the power of the turbine, and obtain performance curves. One of the main issues with wind technology is its high variability, and therefore we implemented a speed regulation system consisting of a mechanism that varies the orientation of the blades and thus allows us to regulate the power of an electric generator attached to the turbine. Current wind powered generators use this type of system to try to smooth out spikes in power that may be caused by gusts of wind. We have used CAD software to design both the turbine itself and the speed regulation system. Most of the turbine parts have been manufactured with the aid of a 3D printer, while the other metallic parts have been turned on made a lathe in aluminum. Although the software programme which calculates the aerodynamics provide us theoretical data about the operation of the rotor. We consider it necessary to test the wind turbine in a lab to obtain more accurate results.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper describes a study and analysis of surface normal-base descriptors for 3D object recognition. Specifically, we evaluate the behaviour of descriptors in the recognition process using virtual models of objects created from CAD software. Later, we test them in real scenes using synthetic objects created with a 3D printer from the virtual models. In both cases, the same virtual models are used on the matching process to find similarity. The difference between both experiments is in the type of views used in the tests. Our analysis evaluates three subjects: the effectiveness of 3D descriptors depending on the viewpoint of camera, the geometry complexity of the model and the runtime used to do the recognition process and the success rate to recognize a view of object among the models saved in the database.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

X-ray computed tomography (CT) imaging constitutes one of the most widely used diagnostic tools in radiology today with nearly 85 million CT examinations performed in the U.S in 2011. CT imparts a relatively high amount of radiation dose to the patient compared to other x-ray imaging modalities and as a result of this fact, coupled with its popularity, CT is currently the single largest source of medical radiation exposure to the U.S. population. For this reason, there is a critical need to optimize CT examinations such that the dose is minimized while the quality of the CT images is not degraded. This optimization can be difficult to achieve due to the relationship between dose and image quality. All things being held equal, reducing the dose degrades image quality and can impact the diagnostic value of the CT examination.

A recent push from the medical and scientific community towards using lower doses has spawned new dose reduction technologies such as automatic exposure control (i.e., tube current modulation) and iterative reconstruction algorithms. In theory, these technologies could allow for scanning at reduced doses while maintaining the image quality of the exam at an acceptable level. Therefore, there is a scientific need to establish the dose reduction potential of these new technologies in an objective and rigorous manner. Establishing these dose reduction potentials requires precise and clinically relevant metrics of CT image quality, as well as practical and efficient methodologies to measure such metrics on real CT systems. The currently established methodologies for assessing CT image quality are not appropriate to assess modern CT scanners that have implemented those aforementioned dose reduction technologies.

Thus the purpose of this doctoral project was to develop, assess, and implement new phantoms, image quality metrics, analysis techniques, and modeling tools that are appropriate for image quality assessment of modern clinical CT systems. The project developed image quality assessment methods in the context of three distinct paradigms, (a) uniform phantoms, (b) textured phantoms, and (c) clinical images.

The work in this dissertation used the “task-based” definition of image quality. That is, image quality was broadly defined as the effectiveness by which an image can be used for its intended task. Under this definition, any assessment of image quality requires three components: (1) A well defined imaging task (e.g., detection of subtle lesions), (2) an “observer” to perform the task (e.g., a radiologists or a detection algorithm), and (3) a way to measure the observer’s performance in completing the task at hand (e.g., detection sensitivity/specificity).

First, this task-based image quality paradigm was implemented using a novel multi-sized phantom platform (with uniform background) developed specifically to assess modern CT systems (Mercury Phantom, v3.0, Duke University). A comprehensive evaluation was performed on a state-of-the-art CT system (SOMATOM Definition Force, Siemens Healthcare) in terms of noise, resolution, and detectability as a function of patient size, dose, tube energy (i.e., kVp), automatic exposure control, and reconstruction algorithm (i.e., Filtered Back-Projection– FPB vs Advanced Modeled Iterative Reconstruction– ADMIRE). A mathematical observer model (i.e., computer detection algorithm) was implemented and used as the basis of image quality comparisons. It was found that image quality increased with increasing dose and decreasing phantom size. The CT system exhibited nonlinear noise and resolution properties, especially at very low-doses, large phantom sizes, and for low-contrast objects. Objective image quality metrics generally increased with increasing dose and ADMIRE strength, and with decreasing phantom size. The ADMIRE algorithm could offer comparable image quality at reduced doses or improved image quality at the same dose (increase in detectability index by up to 163% depending on iterative strength). The use of automatic exposure control resulted in more consistent image quality with changing phantom size.

Based on those results, the dose reduction potential of ADMIRE was further assessed specifically for the task of detecting small (<=6 mm) low-contrast (<=20 HU) lesions. A new low-contrast detectability phantom (with uniform background) was designed and fabricated using a multi-material 3D printer. The phantom was imaged at multiple dose levels and images were reconstructed with FBP and ADMIRE. Human perception experiments were performed to measure the detection accuracy from FBP and ADMIRE images. It was found that ADMIRE had equivalent performance to FBP at 56% less dose.

Using the same image data as the previous study, a number of different mathematical observer models were implemented to assess which models would result in image quality metrics that best correlated with human detection performance. The models included naïve simple metrics of image quality such as contrast-to-noise ratio (CNR) and more sophisticated observer models such as the non-prewhitening matched filter observer model family and the channelized Hotelling observer model family. It was found that non-prewhitening matched filter observers and the channelized Hotelling observers both correlated strongly with human performance. Conversely, CNR was found to not correlate strongly with human performance, especially when comparing different reconstruction algorithms.

The uniform background phantoms used in the previous studies provided a good first-order approximation of image quality. However, due to their simplicity and due to the complexity of iterative reconstruction algorithms, it is possible that such phantoms are not fully adequate to assess the clinical impact of iterative algorithms because patient images obviously do not have smooth uniform backgrounds. To test this hypothesis, two textured phantoms (classified as gross texture and fine texture) and a uniform phantom of similar size were built and imaged on a SOMATOM Flash scanner (Siemens Healthcare). Images were reconstructed using FBP and a Sinogram Affirmed Iterative Reconstruction (SAFIRE). Using an image subtraction technique, quantum noise was measured in all images of each phantom. It was found that in FBP, the noise was independent of the background (textured vs uniform). However, for SAFIRE, noise increased by up to 44% in the textured phantoms compared to the uniform phantom. As a result, the noise reduction from SAFIRE was found to be up to 66% in the uniform phantom but as low as 29% in the textured phantoms. Based on this result, it clear that further investigation was needed into to understand the impact that background texture has on image quality when iterative reconstruction algorithms are used.

To further investigate this phenomenon with more realistic textures, two anthropomorphic textured phantoms were designed to mimic lung vasculature and fatty soft tissue texture. The phantoms (along with a corresponding uniform phantom) were fabricated with a multi-material 3D printer and imaged on the SOMATOM Flash scanner. Scans were repeated a total of 50 times in order to get ensemble statistics of the noise. A novel method of estimating the noise power spectrum (NPS) from irregularly shaped ROIs was developed. It was found that SAFIRE images had highly locally non-stationary noise patterns with pixels near edges having higher noise than pixels in more uniform regions. Compared to FBP, SAFIRE images had 60% less noise on average in uniform regions for edge pixels, noise was between 20% higher and 40% lower. The noise texture (i.e., NPS) was also highly dependent on the background texture for SAFIRE. Therefore, it was concluded that quantum noise properties in the uniform phantoms are not representative of those in patients for iterative reconstruction algorithms and texture should be considered when assessing image quality of iterative algorithms.

The move beyond just assessing noise properties in textured phantoms towards assessing detectability, a series of new phantoms were designed specifically to measure low-contrast detectability in the presence of background texture. The textures used were optimized to match the texture in the liver regions actual patient CT images using a genetic algorithm. The so called “Clustured Lumpy Background” texture synthesis framework was used to generate the modeled texture. Three textured phantoms and a corresponding uniform phantom were fabricated with a multi-material 3D printer and imaged on the SOMATOM Flash scanner. Images were reconstructed with FBP and SAFIRE and analyzed using a multi-slice channelized Hotelling observer to measure detectability and the dose reduction potential of SAFIRE based on the uniform and textured phantoms. It was found that at the same dose, the improvement in detectability from SAFIRE (compared to FBP) was higher when measured in a uniform phantom compared to textured phantoms.

The final trajectory of this project aimed at developing methods to mathematically model lesions, as a means to help assess image quality directly from patient images. The mathematical modeling framework is first presented. The models describe a lesion’s morphology in terms of size, shape, contrast, and edge profile as an analytical equation. The models can be voxelized and inserted into patient images to create so-called “hybrid” images. These hybrid images can then be used to assess detectability or estimability with the advantage that the ground truth of the lesion morphology and location is known exactly. Based on this framework, a series of liver lesions, lung nodules, and kidney stones were modeled based on images of real lesions. The lesion models were virtually inserted into patient images to create a database of hybrid images to go along with the original database of real lesion images. ROI images from each database were assessed by radiologists in a blinded fashion to determine the realism of the hybrid images. It was found that the radiologists could not readily distinguish between real and virtual lesion images (area under the ROC curve was 0.55). This study provided evidence that the proposed mathematical lesion modeling framework could produce reasonably realistic lesion images.

Based on that result, two studies were conducted which demonstrated the utility of the lesion models. The first study used the modeling framework as a measurement tool to determine how dose and reconstruction algorithm affected the quantitative analysis of liver lesions, lung nodules, and renal stones in terms of their size, shape, attenuation, edge profile, and texture features. The same database of real lesion images used in the previous study was used for this study. That database contained images of the same patient at 2 dose levels (50% and 100%) along with 3 reconstruction algorithms from a GE 750HD CT system (GE Healthcare). The algorithms in question were FBP, Adaptive Statistical Iterative Reconstruction (ASiR), and Model-Based Iterative Reconstruction (MBIR). A total of 23 quantitative features were extracted from the lesions under each condition. It was found that both dose and reconstruction algorithm had a statistically significant effect on the feature measurements. In particular, radiation dose affected five, three, and four of the 23 features (related to lesion size, conspicuity, and pixel-value distribution) for liver lesions, lung nodules, and renal stones, respectively. MBIR significantly affected 9, 11, and 15 of the 23 features (including size, attenuation, and texture features) for liver lesions, lung nodules, and renal stones, respectively. Lesion texture was not significantly affected by radiation dose.

The second study demonstrating the utility of the lesion modeling framework focused on assessing detectability of very low-contrast liver lesions in abdominal imaging. Specifically, detectability was assessed as a function of dose and reconstruction algorithm. As part of a parallel clinical trial, images from 21 patients were collected at 6 dose levels per patient on a SOMATOM Flash scanner. Subtle liver lesion models (contrast = -15 HU) were inserted into the raw projection data from the patient scans. The projections were then reconstructed with FBP and SAFIRE (strength 5). Also, lesion-less images were reconstructed. Noise, contrast, CNR, and detectability index of an observer model (non-prewhitening matched filter) were assessed. It was found that SAFIRE reduced noise by 52%, reduced contrast by 12%, increased CNR by 87%. and increased detectability index by 65% compared to FBP. Further, a 2AFC human perception experiment was performed to assess the dose reduction potential of SAFIRE, which was found to be 22% compared to the standard of care dose.

In conclusion, this dissertation provides to the scientific community a series of new methodologies, phantoms, analysis techniques, and modeling tools that can be used to rigorously assess image quality from modern CT systems. Specifically, methods to properly evaluate iterative reconstruction have been developed and are expected to aid in the safe clinical implementation of dose reduction technologies.