956 resultados para 2s albumin


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interaction of quercetin, which is a bioflavonoid, with bovine serum albumin (BSA) was investigated under pseudo-physiological conditions by the application of UV–vis spectrometry, spectrofluorimetry and cyclic voltammetry (CV). These studies indicated a cooperative interaction between the quercetin–BSA complex and warfarin, which produced a ternary complex, quercetin–BSA–warfarin. It was found that both quercetin and warfarin were located in site I. However, the spectra of these three components overlapped and the chemometrics method – multivariate curve resolution-alternating least squares (MCR-ALS) was applied to resolve the spectra. The resolved spectra of quercetin–BSA and warfarin agreed well with their measured spectra, and importantly, the spectrum of the quercetin–BSA–warfarin complex was extracted. These results allowed the rationalization of the behaviour of the overlapping spectra. At lower concentrations ([warfarin] < 1 × 10−5 mol L−1), most of the site marker reacted with the quercetin–BSA, but free warfarin was present at higher concentrations. Interestingly, the ratio between quercetin–BSA and warfarin was found to be 1:2, suggesting a quercetin–BSA–(warfarin)2 complex, and the estimated equilibrium constant was 1.4 × 1011 M−2. The results suggest that at low concentrations, warfarin binds at the high-affinity sites (HAS), while low-affinity binding sites (LAS) are occupied at higher concentrations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The binding interaction of the pesticide Isoprocarb and its degradation product, sodium 2-isopropylphenate, with bovine serum albumin (BSA) was studied by spectrofluorimetry under simulated physiological conditions. Both Isoprocarb and sodium 2-isopropylphenate quenched the intrinsic fluorescence of BSA. This quenching proceeded via a static mechanism. The thermodynamic parameters (ΔH°, ΔS° and ΔG°) obtained from the fluorescence data measured at two different temperatures showed that the binding of Isoprocarb to BSA involved hydrogen bonds and that of sodium 2-isopropylphenate to BSA involved hydrophobic and electrostatic interactions. Synchronous fluorescence spectroscopy of the interaction of BSA with either Isoprocarb or sodium 2-isopropylphenate showed that the molecular structure of the BSA was changed significantly, which is consistent with the known toxicity of the pesticide, i.e., the protein is denatured. The sodium 2-isopropylphenate, was estimated to be about 4–5 times more toxic than its parent, Isoprocarb. Synchronous fluorescence spectroscopy and the resolution of the three-way excitation–emission fluorescence spectra by the PARAFAC method extracted the relative concentration profiles of BSA, Isoprocab and sodium 2-isopropylphenate as a function of the added sodium 2-isopropylphenate. These profiles showed that the degradation product, sodium 2-isopropylphenate, displaced the pesticide in a competitive reaction with the BSA protein.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The structure of the 1:1 brucinium salt of cis-cyclohexane-1,2-dicarboxylic acid, 2,3-dimethoxy-10-oxostrychnidinium (1R,2S)-2-carboxycyclohexane-1-carboxylate dihydrate, has revealed the resolved (1R,2S) enantiomer of the acid. Crystals of the compound are orthorhombic, space group P212121, with unit cell dimensions a = 8.1955(3), b = 12.4034(3), c = 29.9073(9)Å, and Z = 4. The asymmetric unit comprises the brucinium cation, the hydrogen cis-cyclohexane-1,2-dicarboxylate cation, in which the carboxylate group is disordered over two sites (58, 42%), and two water molecules of solvation, one of which is occupies two 50% occupancy sites. The classic undulating brucinium cation substructures are present with the anion and the water molecules occupying the interstitial cavities and are hydrogen-bonded to them in a two-dimensional network structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The expedited 10g protein counter (EP-10) is a quick and valid clinical tool for dietary protein quantification. This study aims to assess the clinical effectiveness of the EP-10 in improving serum albumin and transferrin in chronic hemodialysis patients. Methods: Forty-five patients with low serum albumin (< 38 g /L) were enrolled in this study. Parameters measured included dry weight, height, dietary intake, and levels of serum albumin, transferrin, potassium, phosphate and kinetic modeling (Kt/v). The nutritional intervention incorporated the EP-10 in two ways (1)lto quantify protein intake of patients and (2)ito educate patients to meet their protein requirements. Mean values of the nutritional parameters before and after intervention were compared using paired t-test. Results: Three months after nutritional intervention, mean albumin levels increased significantly from 32.2+4.8g/L to 37.0+3.2g/L (p<0.001). Thirty-eight (84%) patients showed an increase in albumin levels while two (4%) maintained their levels. Of the thirty-six (80%) patients with low transferrin levels (<200 mg/dL), 28 (78%) had an increase and two maintained their levels post-intervention. Mean transferrin levels increased significantly from 169.4+39.9mg/dL to 180.9+38.1mg/dL (p< 0.05). Conclusion: Nutritional intervention incorporating the EP-10 method is able to make significant improvements to albumin and transferrin levels of chronic hemodialysis patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction QC and EQA are integral to good pathology laboratory practice. Medical Laboratory Science students undertake a project exploring internal QC and EQA procedures used in chemical pathology laboratories. Each student represents an individual lab and the class group represents the peer group of labs performing the same assay using the same method. Methods Using a manual BCG assay for serum albumin, normal and abnormal controls are run with a patient sample over 7 weeks. The QC results are assessed each week using calculated z-scores and both 2S & 3S control rules to determine whether a run is ‘in control’. At the end of the 7 weeks a completed LJ chart is assessed using the Westgard Multirules. Students investigate causes of error and the implications for both lab practice and patient care if runs are not ‘in control’. Twice in the 7 weeks two EQA samples (with target values unknown) are assayed alongside the weekly QC and patient samples. Results from each student are collated and form the basis of an EQA program. ALP are provided and students complete a Youden Plot, which is used to analyse the performance of each ‘lab’ and the method to identify bias. Students explore the concept of possible clinical implications of a biased method and address the actions that should be taken if a lab is not in consensus with the peer group. Conclusion This project is a model of ‘real world’ practice in which student demonstrate an understanding of the importance of QC procedures in a pathology laboratory, apply and interpret statistics and QC rules and charts, apply critical thinking and analytical skills to quality performance data to make recommendations for further practice and improve their technical competence and confidence.