1000 resultados para 17-GAUGE CRYOPROBES
Resumo:
OBJECTIVE To investigate the relationship between multiple cryoprobes was investigated to determine whether they work in an additive or synergistic fashion in an in vivo animal model because 1.47 mm (17-gauge) cryoprobes have been introduced to the armamentarium for renal cryotherapy. METHODS Laparoscopic-guided percutaneous cryoablation was performed in both renal poles of 3 pigs using 3 IceRod cryoprobes. These 12 cryolesions were compared with 12 cryolesions using a single IceRod cryoprobe. Each cycle consisted of two 10-minute freeze cycles separated by a 5-minute thaw. The iceball volume was measured using intraoperative ultrasonography. The kidneys were harvested, and cryolesion surface area was calculated. The lesions were fixed and excised to obtain a volume measurement. Statistical analysis was used to compare the single probe results multiplied by 3 to the multiple probe group for iceball volume, cryolesion surface area, and cryolesion volume. RESULTS The iceball volume for the first freeze cycle for the single cryoprobe multiplied by 3 was 8.55 cm(3) compared with 9.79 cm(3) for the multiple cryoprobe group (P = .44) and 10.01 cm(3) versus 16.58 cm(3) for the second freeze (P = .03). The cryolesion volume for the single cryoprobe multiplied by 3 was 11.29 cm(3) versus 14.75 cm(3) for the multiple cyroprobe group (P = .06). The gross cryolesion surface area for the single cryoprobe multiplied by 3 was 13.14 cm(2) versus 13.89 cm(2) for the multiple probe group (P = .52). CONCLUSION The cryolesion created by 3 simultaneously activated 1.47-mm probes appears to be larger than that of an additive effect. The lesions were significantly larger as measured by ultrasonography and nearly so (P = .06) as measured by the gross cryolesion volume. UROLOGY 79: 484.e1-484.e6, 2012. (c) 2012 Elsevier Inc. All rights reserved.
Resumo:
The authors present the first clinical implementation of an endoscopic-assisted percutaneous anterolateral radiofrequency cordotomy. The aim of this article is to demonstrate the intradural endoscopic visualization of the cervical spinal cord via a percutaneous approach to refine the spinal target for anterolateral cordotomy, avoiding undesired trauma to the spinal tissue or injury to blood vessels. Initially, a lateral puncture of the spinal canal in the C1-2 interspace is performed, guided by fluoroscopy. As soon as CSF is reached by the guide cannula (17-gauge needle), the endoscope can be inserted for visualization of the spinal cord and its surrounding structures. The endoscopic visualization provided clear identification of the pial surface of the spinal cord, arachnoid membrane, dentate ligament, dorsal and ventral root entry zone, and blood vessels. The target for electrode insertion into the spinal cord was determined to be the midpoint from the dentate ligament and the ventral root entry zone. The endoscopic guidance shortened the fluoroscopy usage time and no intrathecal contrast administration was needed. Cordotomy was performed by a standard radiofrequency method after refining of the neurophysiological target. Satisfactory analgesia was provided by the procedure with no additional complications or CSF leak. The initial use of this technique suggests that a percutaneous endoscopic procedure may be useful for particular manipulation of the spinal cord, possibly adding a degree of safety to the procedure and improving its effectiveness. (DOI: 10.3171/2010.4.JNS091779)
Resumo:
This paper presents a search for Higgs bosons decaying to four leptons, either electrons or muons, via one or two light exotic gauge bosons Zd, H→ZZd→4ℓ or H→ZdZd→4ℓ. The search was performed using pp collision data corresponding to an integrated luminosity of about 20 fb−1 at the center-of-mass energy of s√=8TeV recorded with the ATLAS detector at the Large Hadron Collider. The observed data are well described by the Standard Model prediction. Upper bounds on the branching ratio of H→ZZd→4ℓ and on the kinetic mixing parameter between the Zd and the Standard Model hypercharge gauge boson are set in the range (1--9)×10−5 and (4--17)×10−2 respectively, at 95% confidence level assuming the Standard Model branching ratio of H→ZZ∗→4ℓ, for Zd masses between 15 and 55 GeV. Upper bounds on the effective mass mixing parameter between the Z and the Zd are also set using the branching ratio limits in the H→ZZd→4ℓ search, and are in the range (1.5--8.7)×10−4 for 15
Resumo:
Purpose:To report the functional, anatomic outcome and safety profile of 23-gauge pars plana vitrectomy (PPV) combined with peeling and intravitreal injection of triamcinolone acetonide (TA) in eyes with idiopathic epiretinal membranes (ERM). Methods:Retrospective, nonrandomized study of consecutive patients who underwent 23-gauge transconjunctival sutureless PPV with subsequent membrane peeling and intravitreal TA injection for an idiopathic ERM. All patients were operated between February 2007 and February 2008 at the Jules Gonin University Eye Hospital. The minimum follow-up was 6-months. Results:Thirty-nine eyes of 39 patients were included. The mean follow-up was 7 months (SD: 2.2, range: 6-15 months). Twenty-two (56%) eyes were pseudophakic and 17 (44%) were phakic at the time of surgery. Mean preoperative intraocular pressure (IOP) was 14 mmHg (SD: 3.5). At the final follow-up mean IOP was 14.5 (SD: 2.7) that did not differ significantly from the IOP at baseline (P: 0.14- 2-tailed t test). Five patients (13%) needed temporary topical anti-glaucoma treatment.Mean preoperative BCVA was 0.28 decimal equivalent (logMAR 0.54, SD: 0.2, range: 1.0 - 0.2). and improved significantly (P <0.0001, 2-tailed t test) to a mean of 0.6 decimal equivalent (logMAR 0.22, SD: 0.16, range: 0.6 - 0) at the final follow-up. The visual acuity improved by a mean of 3.2 lines (SD 2.1, range 0- 8). Twenty-nine patients (74%) demonstrated a gain of 3 or more lines.Mean central macular thickness (CMT) was 456 µm (SD: 77) at the baseline that reduced significantly (P <0.0001, 2-tailed t test) at the final follow-up to 327µm (SD: 79). Average CMT reduction was 131µm (SD: 77, range: 36- 380 µm). A subgroup analysis of 15 selected cases that had CMT measurement 1 week after surgery demonstrated that 84% of the total final reduction in CMT occurred during the first week. Conclusions:23-gauge sutureless transconjunctival vitrectomy with the concomitant administration of intravitreal TA is a safe and effective technique for the treatment of idiopathic ERM and may speed up anatomical recovery.
Resumo:
PURPOSE: To report both the functional and anatomic outcome and safety profile of 23-gauge pars plana vitrectomy combined with membrane peeling and intravitreal injection of triamcinolone acetonide in eyes with idiopathic macular epiretinal membranes. METHODS: Retrospective study of 39 consecutive patients who underwent 23-gauge transconjunctival sutureless vitrectomy, membrane peeling, and intravitreal triamcinolone acetonide injection for an idiopathic macular epiretinal membrane between February 2007 and February 2008. Minimum follow-up was 6 months. RESULTS: Thirty-nine eyes of 39 patients were included in the study. The mean follow-up was 7 +/- 2.2 months (range, 6-15 months). Twenty-two eyes (56%) were pseudophakic and 17 (44%) were phakic at the time of surgery. Five of the phakic eyes (29.4%) had worsening of cataracts during the follow-up period. Mean preoperative intraocular pressure was 14 +/- 3.5 mmHg. At the final follow-up, mean intraocular pressure was 14.5 +/- 2.7 mmHg, which did not differ significantly from the intraocular pressure at baseline (P = 0.14, two-tailed t-test). Five (13%) patients needed topical antiglaucoma treatment. Mean preoperative best-corrected visual acuity (BCVA) was 0.28 decimal equivalent (20/71 Snellen equivalent; logarithm of the minimum angle of resolution 0.54 +/- 0.2, range: 1.0-0.2) and improved significantly (P < 0.0001, two-tailed t-test) to a mean of 0.6 decimal equivalent (20/33 Snellen equivalent; logarithm of the minimum angle of resolution 0.22 +/- 0.16, range: 0.6-0) at the final follow-up. The BCVA improved by a mean of 3.2 +/- 2.1 lines (range: 0-8). Twenty-nine patients (74%) demonstrated a gain of > or =3 lines. Mean central macular thickness was 456 +/- 77 microm (mean +/- SD) at baseline, which was significantly reduced at the final follow-up to 327 +/- 79 microm (mean +/- SD; P < 0.0001, two-tailed t-test). Average central macular thickness reduction was 131 +/- 77 microm (mean +/- SD; range: 36-380 microm). A subgroup analysis of 15 selected cases, which had central macular thickness and BCVA measurements after the first postoperative week, demonstrated that 84% of the total final reduction in central macular thickness and 84% of the total final improvement in BCVA occurred already during the first postoperative week. CONCLUSION: Twenty-three-gauge sutureless transconjunctival vitrectomy is a safe and effective technique for the treatment of idiopathic macular epiretinal membranes. The concomitant administration of intravitreal triamcinolone acetonide after pars plana vitrectomy may speed up and improve the anatomic and functional outcome.
Resumo:
Purpose: The aim of this study was to investigate the level of microstrain that is exerted during polymerization of acrylic resins used for splinting during implant impressions. Material and Methods: Two acrylic resins (GC Pattern Resin, Duralay II) and square transfer coping splinting methods were evaluated by means of strain gauge analysis. Two implants were embedded in a polyurethane block, and the abutments were positioned. Sixty specimens were prepared using two square transfer Copings that were rigidly connected to each other using the acrylic resins. The specimens were randomly divided into three groups of 20 each for the splinting methods: Method 1 was a one-piece method; in method 2, the splint was separated and reconnected after 17 minutes; and in method 3, the splint was separated and reconnected after 24 hours. In each group, half the specimens were splinted with GC Pattern Resin and the other half were splinted with Duralay II. Three microstrain measurements were performed by four strain gauges placed on the upper surface of the polyurethane blocks at 5 hours after resin polymerization for all groups. The data were analyzed statistically. Results: Both resin type and splinting method significantly affected microstrain. interaction terms were also significant. Method 1 in combination with Duralay II produced significantly higher microstrain (1,962.1 mu epsilon) than the other methods with this material (method 2: 241.1 mu epsilon; method 3: 181.5 mu epsilon). No significant difference was found between splinting methods in combination with GC Pattern Resin (method 1: 173.8 mu epsilon; method 2: 112.6 mu epsilon; method 3: 105.4 mu epsilon). Conclusions: Because of the high microstrain generated, Duralay II should not be used for one-piece acrylic resin splinting, and separation and reconnection are suggested. For GC Pattern Resin, variations in splinting methods did not significantly affect the microstrain created. Int J Oral Maxillofac Implants 2012;27:341-345
Resumo:
We present measurements of the process p (P) over bar -> WZ + X -> l 'nu(l ')l (l) over bar at root s = 1:96 TeV,where l and l ' are electrons or muons. Using 1 fb(-1) of data from the D0 experiment, we observe 13 candidates with an expected background of 4.5 +/- 0.6 events and measure a cross section sigma(WZ) = 2.7(-1.3)(+1.7) pb. From the number of observed events and the Z boson transverse momentum distribution, we limit the trilinear WWZ gauge couplings to -0: 17 <= lambda(Z) <= 0.21 (Delta k(Z) <= 0.29(lambda(Z) = 0) at the 95% C.L. for a form factor scale Lambda = 2 TeV. Further, assuming that Delta g(1)(Z) = Delta k(Z), we find -0.12 <= Delta k(Z) <= 0.29(lambda(Z) = 0) at the 95% C. L. These are the most restrictive limits on the WWZ couplings available to date.
Resumo:
In the usual and current understanding of planar gauge choices for Abelian and non-Abelian gauge fields, the external defining vector n(mu), can either be space-like (n(2) < 0) or time-like (n(2) > 0) but not light-like (n(2) = 0). In this work we propose a light-like planar gauge that consists of defining a modified gauge-fixing term, L-GF, whose main characteristic is a two-degree violation of Lorentz covariance arising from the fact that four-dimensional space-time spanned entirely by null vectors as basis necessitates two light-like vectors, namely n(mu) and its dual m(mu), with n(2) = m(2) = 0, n . m not equal 0, say, e.g. normalized to n . m = 2.
Resumo:
In this note we show that the induced 2D-gravity SL(2, ℝ) currents can be defined in a gauge-independent way although they manifest themselves as generators of residual symmetries only in some special gauges. In the Coulomb gas representation we investigate two approaches, namely one resembling string field theory and another that emphasizes the SL(2, ℝ) structure in the phase space. In the conformal gauge we propose a solution of the Liouville theory in terms of the SL(2, ℝ) currents.
Resumo:
A scheme inspired in Lie algebra extensions is introduced that enlarges gauge models to allow some coupling between space-time and gauge space. Everything may be written in terms of a generalized covariant derivative including usual differential plus purely algebraic terms. A noncovariant vacuum appears, introducing a natural symmetry breaking, but currents satisfy conservation laws alike those found in gauge theories. © 1991 American Institute of Physics.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
We describe and test a nonperturbatively improved single-plaquette lattice action for 4-d SU(2) and SU(3) pure gauge theory, which suppresses large fluctuations of the plaquette, without requiring the naive continuum limit for smooth fields. We tune the action parameters based on torelon masses in moderate cubic physical volumes, and investigate the size of cut-off effects in other physical quantities, including torelon masses in asymmetric spatial volumes, the static quark potential, and gradient flow observables. In 2-d O(N) models similarly constructed nearest-neighbor actions have led to a drastic reduction of cut-off effects, down to the permille level, in a wide variety of physical quantities. In the gauge theories, we find significant reduction of lattice artifacts, and for some observables, the coarsest lattice result is very close to the continuum value. We estimate an improvement factor of 40 compared to using the Wilson gauge action to achieve the same statistical accuracy and suppression of cut-off effects.